IP protection test<br />

DIN EN 60529<br />

IP6X: protection of the contact <strong>in</strong>serts<br />

<strong>in</strong>side the hous<strong>in</strong>g aga<strong>in</strong>st the <strong>in</strong>gress of<br />

dust <strong>in</strong> the presence of a slight vacuum.<br />

Parameters: vacuum: 20 mbar, test<br />

duration: 8 hours<br />

HEAVYCON EVO <strong>plug</strong>-<strong>in</strong> <strong>connectors</strong><br />

meet the requirements of IP65<br />

protection: no discernable, visible<br />

<strong>in</strong>gress of dust or water <strong>in</strong>side the<br />

hous<strong>in</strong>g.<br />

IPX5: protection aga<strong>in</strong>st the harmful<br />

effects of the <strong>in</strong>gress of jet water.<br />

Parameters: jet nozzle: 6.3 mm,<br />

volumetric water flow: 12.5 l/m<strong>in</strong>,<br />

m<strong>in</strong>imum test duration: 3 m<strong>in</strong>utes<br />

Jet water test and dust test<br />

Vibration test<br />

IEC 60068-2-6<br />

This test demonstrates the vibration<br />

resistance of an electrical connection.<br />

Harmonic, s<strong>in</strong>usoidal vibrations are<br />

applied to the test object to simulate<br />

rotat<strong>in</strong>g, pulsat<strong>in</strong>g or oscillat<strong>in</strong>g forces.<br />

Along all three axes (xyz), frequencies<br />

<strong>in</strong> the 10 - 2000 Hz range, for example,<br />

are successively applied at a rate of<br />

one octave per m<strong>in</strong>ute. The r.m.s.<br />

value of the acceleration is 50 m/s 2 , for<br />

example.<br />

There must be no damage to the test<br />

object that might impair further use or<br />

adversely affect the constant electrical<br />

values.<br />

HEAVYCON EVO <strong>plug</strong>-<strong>in</strong> <strong>connectors</strong><br />

meet these high requirements and are<br />

therefore suitable for applications on<br />

construction vehicles and mach<strong>in</strong>ery,<br />

for example.<br />

Vibration test accord<strong>in</strong>g to IEC 60068-2-6<br />

Temperature shock test<br />

IEC 60512-11-4, test 11d<br />

In <strong>in</strong>dustrial applications, significant<br />

temperature differences result<strong>in</strong>g<br />

from the process may occur. In order<br />

to simulate such ambient conditions,<br />

the test objects are moved with<strong>in</strong> the<br />

space of a few seconds between the<br />

lower and upper limit temperature<br />

(e.g., -50°C to +85°C) of the product<br />

and usually rema<strong>in</strong> there for 45 m<strong>in</strong>utes.<br />

This must not result <strong>in</strong> damage that<br />

might impair further use.<br />

Thanks to the use of high-quality<br />

materials, HEAVYCON EVO <strong>plug</strong>-<strong>in</strong><br />

<strong>connectors</strong> are suitable for applications<br />

at an ambient temperature of -40°C<br />

to +100°C with constant temperature<br />

response.<br />

HEAVYCON EVO <strong>plug</strong>-<strong>in</strong> connector <strong>in</strong> the<br />

climatic chamber at -50°C<br />