Air Inlet Construction<br />

Attic and loft spaces should always be ventilated<br />

effectively, to meet specific ventilation standards.<br />

Fakro <strong>roof</strong> <strong>windows</strong> are installed with special air<br />

inlets, which provide a free flow of fresh air to the<br />

room even when <strong>windows</strong> are closed. Stale air<br />

should be removed by means of existing ventilation,<br />

generally found in bathrooms, kitchens, or<br />

through ventilation shafts and ducting.<br />

Air inlet V-35<br />

Air inlet V-10<br />

Positioned on the top part<br />

of the window frame, the<br />

V-10 has a manually adjustable<br />

air flow regulator. When<br />

fully opened this inlet supplies<br />

fresh air at 10m³/h at a<br />

pressure difference of 10Pa.<br />

The inlet’s construction provides<br />

excellent filtering and<br />

acoustic insulation. Air inlet<br />

V-10 should be used solely<br />

in rooms where unassisted<br />

gravitational ventilation<br />

works well.<br />

Used in the following <strong>windows</strong>:<br />

— FTS-V<br />

— FTL/D, FTL/D-W<br />

— FLL<br />

Air Inlet V-35<br />

Positioned at the top part of<br />

the window frame, features<br />

a manual air flow regulator.<br />

When fully opened this<br />

inlet supplies fresh air at<br />

21 to 38m³/h at a pressure<br />

difference of 10Pa, depending<br />

upon the width of the<br />

window.<br />

As a result of this greater efficiency,<br />

air humidity inside the<br />

room is effectively reduced,<br />

thereby reducing condensation.<br />

The V-35 air inlet can<br />

in part discharge air, when<br />

normal gravitational ventilation<br />

isn’t working properly. Its<br />

excellent venting efficiency<br />

guarantees that a greater<br />

amount of stale and humid<br />

air is removed from the room.<br />

Hygroscopically<br />

Controlled Air Inlet<br />

Positioned in the top part of<br />

the window frame, this provides<br />

automatic regulation<br />

of airflow, depending upon<br />

the level of humidity inside<br />

the room. Supplies fresh air<br />

at 30m³/h at a pressure difference<br />

of 10Pa. A hygroscopic<br />

polyamide tape acts as a sensor,<br />

increasing or reducing in<br />

size according to humidity<br />

levels, thereby applying pressure<br />

to a piston within the<br />

unit. The inlet monitors room<br />

humidity continuously and<br />

automatically and even when<br />

left open, does not expose<br />

the room to unnecessary loss<br />

of warmth. The hygroscopically<br />

controlled air inlet is<br />

used with the V-35.<br />

Manometer Air Inlet<br />

Positioned in the top part of<br />

the window frame, the inlet<br />

is controlled by variations in<br />

air pressure. The inlet is fully<br />

automatic, so that even during<br />

extreme weather conditions,<br />

a suitable fresh airflow<br />

is maintained, at a rate of<br />

30m³/h. Airflow is regulated<br />

by a polythene tape inside<br />

the air inlet which changes its<br />

position with variations in air<br />

pressure. The manometer air<br />

inlet is used with the V-35.<br />

Used in the following <strong>windows</strong>:<br />

FTP-V/P, FTP-W/P<br />

Used in the following <strong>windows</strong>:<br />

— FTP-V, FTP-W<br />

— FPP<br />

Used in the following <strong>windows</strong>:<br />

— FTP-V/H, FTP-W/H<br />

18 www.fakro.com