5-1<br />

Product Selection Guide<br />

<strong>Temperature</strong> <strong>Controllers</strong>


<strong>Temperature</strong> <strong>Controllers</strong><br />

Selection Guide<br />

Contents<br />

<strong>Temperature</strong> <strong>Controllers</strong> Selection Guide...............2<br />

<strong>Temperature</strong> <strong>Controllers</strong> Selection Guide<br />

Throttling Thermostats............................................3<br />

Throttling Thermostats<br />

Provide a proportional pneumatic output for control of burner<br />

valves, mixing valves or air shutters.<br />

Snap Acting Thermostats ......................................4<br />

Snap Acting Thermostats<br />

Provide an on / off pneumatic output for control of burner valves,<br />

mixing valves or air shutters.<br />

Shut-Downs............................................................5<br />

Shut-Downs<br />

Provide an on / off pneumatic output for shutting down of burner<br />

valves or mixing valves.<br />

Burner Valves.........................................................6<br />

Burner Valves<br />

Modulate burner flame or shut-in burner systems.<br />

5-2<br />

Separable Sockets & Thermowells........................6<br />

Separable Sockets & Thermowells<br />

Protect Thermostats or Thermometers. Allows Thermostat or<br />

Thermometer removal without losing vessel pressure.<br />

PROVEN DESIGN<br />

With 57 years of building experience, many of our<br />

original designs are still current technology, tried<br />

and tested in literally thousands of installations.


<strong>Temperature</strong> <strong>Controllers</strong><br />

Throttling Thermostats<br />

Indirect Throttle T 12<br />

Features:<br />

Single adjustment<br />

High accuracy<br />

Intermittent-bleed construction<br />

Bi-metalic sensing element<br />

Supply Pressure: 5 to 30 psig<br />

Indirect control of burner valves, mixing valves, air shutters<br />

Indirect Throttle High Capacity<br />

T 12T<br />

Working Pressure (sensing element):<br />

500 psig without Separable Socket<br />

4000 psig with Separtable Socket<br />

7000 psig with Special Separable Socket<br />

Separable socket is an extra price item and is ordered<br />

separately.<br />

<strong>Temperature</strong> Range:<br />

T 12, T 18 -30 o to 400 o F<br />

-34 o to 204 o C<br />

HT 12, HT 18 -30 o to 750 o F<br />

-34 o to 399 o C<br />

Options:<br />

Elastomers: HSN, Viton ® , Aflas ®<br />

Metal Material: 316 Stainless Steel internal<br />

exposed parts<br />

Indirect control of burner valves, mixing valves, air shutters<br />

where quick response or high volume of pneumatic output is<br />

required.<br />

Indirect Throttle with Burner Valve 1TC 12<br />

Indirect Acting Thermostats:<br />

Output decreases with temperature rise.<br />

Direct Acting Thermostats:<br />

Output increases with temperature rise.<br />

<strong>Temperature</strong> controller includes T 12 Thermostat, Filter Pop<br />

Valve, and 1” Burner Valve.<br />

Direct Throttle<br />

Direct control of burner valves, mixing valves, air shutters<br />

T 12TDA<br />

NO “DEADBAND”<br />

The sensing element in the <strong>Kimray</strong><br />

Thermostat is a bi-metalic probe. The outer<br />

tube is 304 stainless steel, and the inner<br />

rod is low expansion nickel. The expansion<br />

rates due to heat in both the metals are very<br />

consistent which provides smooth, proportional<br />

output -- throttling action.<br />

When the thermostat is installed with its<br />

probe completely surrounded by the liquid<br />

or gas it is monitoring, there is virtually no<br />

deadband.<br />

Other types of thermostats providing such<br />

control cost considerably more, and lack the<br />

simplicity.<br />

In describing the <strong>Kimray</strong> Thermostat folks<br />

have said,<br />

“IT’S LIKE A CADILLAC THERMOSTAT<br />

AT A CHEVY PRICE!”<br />

5-3


<strong>Temperature</strong> <strong>Controllers</strong><br />

Snap Acting (On / Off) Thermostats<br />

Features:<br />

Single adjustment<br />

High accuracy<br />

Intermittent-bleed construction<br />

Bi-metalic sensing element<br />

Supply Pressure: 5 to 30 psig<br />

Direct Snap<br />

T 12DA<br />

Working Pressure (sensing element):<br />

500 psig without Separable Socket<br />

4000 psig with Separtable Socket<br />

7000 psig with Special Separable Socket<br />

Separable socket is an extra price item and is ordered<br />

separately.<br />

Direct on/off control of burner valves, mixing valves, air shutters<br />

<strong>Temperature</strong> Range:<br />

T 12, T 18 -30 o to 400 o F<br />

-34 o to 204 o C<br />

HT 12, HT 18 -30 o to 750 o F<br />

-34 o to 399 o C<br />

Options:<br />

Elastomers: HSN, Viton ® , Aflas ®<br />

Metal Material: 316 Stainless Steel internal<br />

exposed parts<br />

Indirect Acting Thermostats:<br />

Output decreases with temperature rise.<br />

Direct Acting Thermostats:<br />

Output increases with temperature rise.<br />

Direct Snap High Capacity<br />

T 12S<br />

5-4<br />

Direct on/of control of burner valves, mixing valves, air<br />

shutters where high volume of pneumatic output is required.<br />

Indirect Snap<br />

T12 DAS<br />

“WHAT’S A SEPERABLE SOCKET”<br />

Some call it a Thermowell. We call the well<br />

for a thermometer a Thermowell.<br />

The Separable Socket is a protective well<br />

designed for the <strong>Kimray</strong> Thermostat.<br />

It protects the Thermostat probe from corrosion<br />

or physical forces which could bend it. It also<br />

increases the maximum working pressure of<br />

the Thermostat.<br />

Indirect on/off control of burner valves, mixing valves, air shutters


<strong>Temperature</strong> <strong>Controllers</strong><br />

Shut - Downs<br />

Indirect High <strong>Temperature</strong> Shut-Down<br />

T 12M<br />

Features:<br />

Single adjustment<br />

High accuracy<br />

Intermittent-bleed construction<br />

Bi-metalic sensing element<br />

Supply Pressure: 5 to 30 psig<br />

Working Pressure (sensing element):<br />

500 psig without Separable Socket<br />

4000 psig with Separtable Socket<br />

7000 psig with Special Separable Socket<br />

Separable socket is an extra price item and is ordered<br />

separately.<br />

For temperature controlled system shutdown until manually<br />

reset. Shuts off when system temperature exceeds setpoint<br />

Direct Low <strong>Temperature</strong> Shut-Down<br />

T 12DAM<br />

<strong>Temperature</strong> Range:<br />

T 12, T 18 -30 o to 400 o F<br />

-34 o to 204 o C<br />

HT 12, HT 18 -30 o to 750 o F<br />

-34 o to 399 o C<br />

Options:<br />

Elastomers: HSN, Viton ® , Aflas ®<br />

Metal Material: 316 Stainless Steel internal<br />

exposed parts<br />

Indirect Acting Thermostats:<br />

Output decreases with temperature rise.<br />

Direct Acting Thermostats:<br />

Output increases with temperature rise.<br />

For temperature controlled system shutdown until manually<br />

reset. Shuts off when system temperature drops below setpoint<br />

5-5<br />

Pilot Guard<br />

HT12 PG<br />

“TURN IT OFF, QUICK!”<br />

Sometimes it’s too hot-<br />

Sometimes it’s too cool-<br />

Sometimes the fire just goes out.<br />

Whatever the reason, if the temperature gets out<br />

of control, you need to shut everything off right<br />

away! These shut-downs are just what you need,<br />

when you need to stop and start over.<br />

Indirect action for system shut-down when pilot flame goes<br />

out. Also used in direct mode for high stack temperture<br />

shutdown


<strong>Temperature</strong> <strong>Controllers</strong><br />

Burner Valves, Separable Sockets &Thermowells<br />

Features:<br />

Equal Percentage trim<br />

Single seat<br />

Soft seat for bubble tight shut-off<br />

Pressure Opening / Fail Closing<br />

Special stem seal requires no lubrication<br />

Spring Closing Pressure Opening<br />

SMT DAB<br />

Pressure opening Burner Valve<br />

where a reduced inner valve is<br />

desired and manifold pressures do<br />

not exceed 25 psig.<br />

5-6<br />

Construction Materials:<br />

Body Cast Iron Ductile Iron Steel<br />

Design<br />

Pressure<br />

Scrd. 175 psi<br />

Flgd. 175 psi<br />

Sizes available:<br />

DAB & MT-T:<br />

1” NPT<br />

2” NPT, Flanged<br />

3” NPT, Flanged<br />

4” Flanged<br />

6” Flanged<br />

ADA:<br />

1” NPT<br />

2” NPT, Flanged<br />

Scrd. 300 psi<br />

Flgd. 250 psi<br />

Normal Operating <strong>Temperature</strong>:<br />

-20 o to 200 o F<br />

Flgd. 285 psi<br />

Stem 303 Stainless 303 Stainless 303 Stainless<br />

Plug Ductile Iron Ductile Iron Steel<br />

Seat Nitrile Polyurethane Polyurethane<br />

Diaphragms Nitrile/Nylon Nitrile/Nylon Nitrile/Nylon<br />

Options:<br />

Elastomers: HSN, Viton ® , Aflas ®<br />

Trim Material: 316 Stainless Steel internal parts<br />

Orifice Size: LIne size or reduced<br />

Adjustable Pressure Opening<br />

Fail Closed Pressure Opening<br />

SMT ADA<br />

Pressure opening Burner Valve<br />

for throttling or snap action service<br />

and where manifold pressures do<br />

not exceed 40 psig.<br />

SMT-T<br />

Pressure opening Burner Valve<br />

for throttle action service, or shut<br />

in against pressures up to 300<br />

psig. Uses upstream pressure to<br />

close valve when no open signal<br />

is present.<br />

Features:<br />

Increases working pressure of Thermostat Sensing<br />

Element. Allows Thermostat removal without losing<br />

vessel pressure. Filled with high temperature grease.<br />

Separable Socket Materials: Steel & 316<br />

Stainless<br />

Working Pressure: 1000, 4000, & 7000 psig<br />

Connections:<br />

External Thread: 3/4” and 1” NPT<br />

Internal Thread: 1/2” NPT<br />

Allows thermometer removal for maintanence without<br />

losing vessel pressure.<br />

Thermowell Materials: 304 SS & 316 SS<br />

Working Pressure: 1000 to 4000 psig W.P.<br />

Connections:<br />

External Thread: 1/2” and 3/4” NPT<br />

Internal Thread: 1/4” and 1/2” NPT<br />

Separable Sockets<br />

Thermometer Wells