Sulfur Analysis<br />
Rt®-XLSulfur Packed/Micropacked Columns<br />
• Optimized <strong>columns</strong> for low pbbv sulfur analyses.<br />
• Eliminate the need for Teflon® tubing.<br />
• Column and end-fittings are Sulfinert® treated for maximum inertness.<br />
GC COLUMNS | PACKED/MICROPACKED COLUMNS<br />
Specialty Packed/Micropacked Columns<br />
Sulfur analyses are traditionally performed using Teflon® tubing to improve column<br />
inertness. Unfortunately, Teflon® tubing is gas permeable, difficult to pack with high<br />
efficiency, prone to shrinkage, and has poor thermal stability. The Rt®-XLSulfur packed<br />
or micropacked column eliminates these problems. The packing material for<br />
Rt®-XLSulfur <strong>columns</strong> is extensively deactivated for analysis of low ppbv levels of<br />
hydrogen sulfide and methyl mercaptan. It is then treated to achieve effective separation<br />
of hydrocarbons from sulfur compounds. The interior wall and the end-fittings of the<br />
Rt®-XLSulfur column are Siltek® treated, making the column as inert as Teflon®. The<br />
extra care taken to manufacture this column ensures more accurate analyses of sulfur<br />
compounds.<br />
Rt®-XLSulfur Columns (packed)*<br />
OD ID 1-Meter 2-Meter<br />
1<br />
/8" 2.0mm 80484- 80485-<br />
3<br />
/16" 3.1mm 80482- 80483-<br />
Rt®-XLSulfur Columns (micropacked)**<br />
OD ID 1-Meter 2-Meter<br />
1<br />
/16" 1.0mm 19804 19805<br />
0.95mm 0.75mm 19806 19807<br />
*Please add column instrument configuration suffix number to cat.# when ordering. See chart on this page.<br />
**Does not include column nuts and ferrules. Optional installation kits can be ordered separately—<br />
see page 133.<br />
did you know<br />
Rt®-XLSulfur <strong>columns</strong> are optimized for low<br />
ppb-level sulfur analysis!<br />
also available<br />
For adapter kits for installing<br />
packed/micropacked <strong>columns</strong>, see page 133.<br />
Rt®-XLSulfur micropacked column separates hydrocarbons from sulfur<br />
compounds.<br />
Column Instrument Configurations<br />
A<br />
B 1<br />
D<br />
E<br />
F<br />
Easily detect 50ppb of<br />
each sulfur compound!<br />
sulfurs<br />
1. hydrogen sulfide<br />
2. carbonyl sulfide<br />
3. methyl mercaptan<br />
4. ethyl mercaptan<br />
5. dimethyl sulfide<br />
6. dimethyl disulfide<br />
General Configuration<br />
Suffix -800<br />
Agilent 5880, 5890, 5987,<br />
6890, 7890:<br />
Suffix -810*<br />
2<br />
C<br />
3<br />
4/5<br />
H<br />
G<br />
I<br />
6<br />
hydrocarbons<br />
A. methane<br />
B. ethane<br />
C. propylene<br />
D. propane<br />
E. isobutane<br />
F. butane<br />
G. isopentane<br />
H. pentane<br />
I. hexane<br />
8 3 /4"<br />
Varian 3700, Vista Series, FID:<br />
Suffix -820<br />
PE 900-3920, Sigma 1,2,3:<br />
Suffix -830<br />
min. 2 4 6 8 10<br />
GC_PC00436<br />
Column: Rt ® -XLSulfur micropacked column, 1m, 0.75mm ID<br />
(cat.# 19806)<br />
Conc.: 50ppb each<br />
Oven temp.: 60°C to 230°C @ 15°C/min.<br />
Carrier gas: helium<br />
Flow rate: 9mL/min.<br />
Det.:<br />
SCD/FID<br />
Sulfur standards courtesy of DCG Partnership 1 Ltd., Pearland, TX.<br />
6 1 /2"<br />
PE Auto System 8300, 8400, 8700<br />
Suffix -840<br />
See page 143 for additional configurations.<br />
Note: Initial 2" of column will be empty, to<br />
accommodate a needle. For a completely filled<br />
column (not on-column) add suffix -901.<br />
*-810 suffix also includes 1 1 /2" void on detector side.<br />