<strong>2.3</strong> HOUSING SA UNIVERSAL HOUSING DESIGN CRITERIA<br />
2<br />
1100mm - shower alcove<br />
1:60 1:60 1:100 - to floor trap<br />
outlet<br />
Section - Shower Alcove<br />
Figure 12a:<br />
Stepless shower alcove<br />
to larger bathrooms<br />
1100mm - shower alcove<br />
1:60 1:60 1:100<br />
Section - Shower Alcove<br />
outlet<br />
Note: refer to Minister’s Specification SA F1.7 (<strong>July</strong> 2004) -<br />
Waterproofing of wet areas in buildings -<br />
Additional requirements - <strong>for</strong> waterproofing details.<br />
Figure 12b:<br />
Stepless shower alcove<br />
to smaller bathrooms<br />
Water Closet (WC)<br />
A disabled person’s WC, with rim 460mm above floor level, is not<br />
required, but may be provided as a modification.<br />
The front of the pan should be a minimum of 600mm from the<br />
back wall and 450mm from the side wall.<br />
Additional trimmers are required <strong>for</strong> future grab rails as shown.<br />
1600mm clear <strong>for</strong> circulation<br />
450mm 1150mm<br />
Figure 13:<br />
Toilet set out<br />
800mm<br />
650mm<br />
300mm<br />
maximum<br />
maximise set out of<br />
toilet in accordance with<br />
suppliers specification<br />
450mm<br />
stepless shower area can share<br />
WC circulation space<br />
1100mm clear <strong>for</strong> circulation<br />
© Crown Copyright<br />
Government of South Australia<br />
16<br />
<strong>Housing</strong> <strong>Design</strong> Guidelines<br />