INSERTION FLOW SENSOR MyProc MFS 0242<br />

• Continuous flow measurement for use in neutral, slightly aggressive and solid free liquids<br />

• Paddle-wheel flow sensor<br />

• Simple installation into all pipes from PN 15 to 400<br />

• Frequency pulse signal, proportional to flow rate<br />

!<br />

MFT 0247<br />

General data:<br />

Compatibility<br />

with fittings MAF 242 (see corresp. data sheet)<br />

Materials<br />

Housing / Union nut<br />

PE / PC<br />

Cable plug<br />

PA<br />

Materials wetted parts Fitting<br />

Brass, stainless steel 1.4404/316L, PVC, PP, PVDF<br />

Finger, paddle-wheel<br />

PVDF<br />

Axis and bearing<br />

Ceramics<br />

Seal<br />

FKM (EPDM option)<br />

Electrical connections Cable plug EN 175301-803<br />

Connection cable<br />

Cross-section<br />

1.5 mm 2 max.<br />

Repeatibility ≤ 0.4 % of Reading 1)<br />

Recommended length<br />

max. 50 m, shielded<br />

Complete device data (fitting + sensor MFS 0242):<br />

Pipe diameter DN 15 to 400<br />

Measuring range<br />

0.3 to 10 m/s<br />

Fluid temperature with<br />

PVC fitting 0 up to 50 °C<br />

PP fitting 0 up to 80 °C<br />

St.st., brass, PVDF fitting -15 up to 80 °C<br />

Fluid pressure max.<br />

PN10<br />

Viscosity<br />

300 cSt. max.<br />

Accuracy<br />

Teach-In ≤ ± 0.5 % of F.S.* (at 10 m/s) 1)<br />

Standard K-factor ≤ ± (0.5 % of F.S.* + 2.5 % o. Reading) 1)<br />

Linearity ≤ ± 0.5 % of F.S.* (at 10 m/s) 1)<br />

Electrical data:<br />

Power supply<br />

Current consumption<br />

Pulse version<br />

Pulse “Low power” vers.<br />

Output: Frequency<br />

Pulse version<br />

Pulse “Low Power” vers.<br />

Reversed polarity of DC<br />

12–36 V DC<br />

with sensor<br />

≤ 50 mA<br />

≤ 0.8 mA<br />

Transistor NPN/PNP, open collector,<br />

max. 100 mA, frequency: 0...300 Hz;<br />

duty cycle 1/2<br />

Transistor NPN, open collector,<br />

max. 10 mA, frequency: 0...300 Hz;<br />

duty cycle 1/2<br />

Protected<br />

Flow transmitter<br />

MFC 0247<br />

Batch controller<br />

MAF 242<br />

Insertion fitting<br />

PLC<br />

Environment:<br />

Ambient temperature<br />

Relative humidity<br />

-15 up to +60 °C (operating and storage)<br />

≤ 80 %, non condensated<br />

Standards and approvals:<br />

Protection class<br />

IP65, with cable mounted and tigthened<br />

Standard<br />

EMC EN 61000-6-2, 61000-6-3<br />

Vibration EN 60068-2-6<br />

Shock EN 60068-2-27<br />

* FS. = Full scale (10 m/s)<br />

1) Under reference conditions i.e. measuring fluid = water, ambient and water temperature = 20 °C, applying the minimum inlet and outlet pipe straight, matched inside pipe dimensions.<br />

6<br />

Meyer <strong>Industrie</strong>-<strong>Electronic</strong> <strong>GmbH</strong> – MEYLE<br />

Carl-Bosch-Straße 8<br />

49525 Lengerich/Germany<br />

Tel.: +49 54 81-93 85-0<br />

Fax: +49 54 81-93 85-12<br />

Internet: www.meyle.de<br />

E-Mail: sales@meyle.de