5<br />

Technical information manual <strong>UTA</strong>-ECHOS<br />

REF. <strong>UTA</strong>-ECHOS-/<strong>UTA</strong>_ECHOS_2011.DOC<br />

The accessory “air mix plenum (recirculation/external air)” exists only for <strong>UTA</strong>/ <strong>UTA</strong>H Echos 6-18 models, which allows the<br />

adjustment of the mix between the external air capacity (renew) and that of the internal air (recirculation).<br />

ELECTRIC HEATING COIL<br />

Is made with frame in galvanised sheet and armoured aluminium heating elements which allow a rapid and uniform heat<br />

transmission; is complete with protection fuses, safety thermostat and isolating switch. In the functioning coupled with the <strong>UTA</strong>H<br />

Echos units,its insertion is adjusted by a microprocessor, this condensing unit through the return air temperature; it is always<br />

activated during the defrosting cycle. You can change the set point of the resistance activation by adjusting the parameters A08-<br />

A09. Refer to the service before making any changes.<br />

HOT WATER COIL<br />

Is made with copper pipes coil and aluminium louvers. This accessory is necessary when it is not advisable to heat the room with<br />

“heat pump” unit (with low temperatures of the external air); upon request, it can be mounted with the hydraulic connections on the<br />

right side of the unit.<br />

SILENCED PLENUM<br />

Made with a septa silencer, reduces the noise inserted in the air duct.<br />

FLOW INLET PLUG<br />

The accessory “flow inlet plug” exist only for models <strong>UTA</strong>/<strong>UTA</strong>H Echos 6-18, which facilitates the connection for the distribution of<br />

air through the flexible ducts.<br />

GAS ATTACHMENTS ON THE OPPOSITE SIDE TO THE STANDARD ONE<br />

Upon request, the connections can be mounted on the right side of the unit.<br />

FANS USEFUL PREVALENCE from 100 Pa to 300 Pa<br />

In case it is necessary to duct the UTW and <strong>UTA</strong>/<strong>UTA</strong>H units with functionings which require static prevalence from 100 to 300 Pa,<br />

it is possible to select one of the following accessories:<br />

• fans useful prevalence equal to 100 Pa;<br />

• fans useful prevalence equal to 150 Pa;<br />

• fans useful prevalence equal to 200 Pa;<br />

• fans useful prevalence equal to 250 Pa;<br />

• fans useful prevalence equal to 300 Pa.<br />