Typical Applications<br />

for Carbon Dioxide<br />

Measurement<br />

<strong>Vaisala</strong> CARBOCAP <strong>in</strong>struments<br />

are well suited to a wide range of<br />

applications, from ppm (parts per<br />

million) to percentage-level CO 2<br />

measurements. S<strong>in</strong>ce CO 2<br />

is harmful<br />

<strong>in</strong> high concentrations, it is present at<br />

percentage levels only with<strong>in</strong> closed<br />

processes such as fermentation<br />

and controlled-atmosphere storage<br />

environments. Percentage-level<br />

measurements are also typical <strong>in</strong><br />

life-science applications such as CO 2<br />

<strong>in</strong>cubation.<br />

Normal atmospheric air <strong>in</strong>cludes CO 2<br />

at ppm levels. Typical CARBOCAP<br />

applications <strong>in</strong>clude ventilation<br />

control <strong>in</strong> build<strong>in</strong>gs occupied<br />

by people, animal shelters, and<br />

greenhouses. In areas where large<br />

volumes of CO 2<br />

are handled, reliable<br />

CO 2<br />

measurement with alarm control<br />

is an important safety precaution.<br />

The CARBOCAP sensor is also<br />

a popular choice <strong>in</strong> ecological<br />

measurement applications, where<br />

excellent long-term stability and<br />

tolerance to harsh conditions are<br />

important requirements.<br />

CARBOCAP CO 2<br />

Products<br />

<strong>Vaisala</strong> offers <strong>in</strong>struments for<br />

measur<strong>in</strong>g CO 2<br />

at ppm and<br />

percentage levels <strong>in</strong> both <strong>in</strong>door and<br />

outdoor environments. <strong>Vaisala</strong>'s wide<br />

variety of CO 2<br />

<strong>in</strong>struments ranges<br />

from hand-held meters, measurement<br />

modules, and <strong>in</strong>dustrial transmitters<br />

to high-volume, affordable<br />

transmitters for volume applications.<br />

View the complete range of CO 2<br />

products at www.vaisala.com/<br />

carbondioxide.<br />

Mirror surface<br />

CO 2<br />

IR absorption<br />

Structure of the CARBOCAP sensor.<br />

Protective w<strong>in</strong>dow<br />

IR source<br />

Fabry-Perot<br />

Interferometer Filter<br />

Detector<br />

Carbon Dioxide<br />

The CARBOCAP® Story<br />

The CARBOCAP story began<br />

<strong>in</strong> 1992, when micromechanical<br />

sensors were be<strong>in</strong>g <strong>in</strong>tensively<br />

researched at <strong>Vaisala</strong>. The<br />

groundbreak<strong>in</strong>g idea of<br />

m<strong>in</strong>iaturiz<strong>in</strong>g the Fabry-Perot<br />

Interferometer (FPI) was<br />

born, lead<strong>in</strong>g to collaborative<br />

development work with VTT<br />

Technical Research Center of<br />

F<strong>in</strong>land. Later, a patent application<br />

was submitted for a s<strong>in</strong>gle-channel<br />

gas concentration measurement<br />

method us<strong>in</strong>g the FPI.<br />

The driv<strong>in</strong>g force beh<strong>in</strong>d the<br />

<strong>in</strong>novation of the CARBOCAP<br />

sensor was <strong>Vaisala</strong>'s commitment<br />

to develop<strong>in</strong>g superior<br />

technologies for environmental<br />

measurements. And <strong>in</strong>deed,<br />

<strong>Vaisala</strong>’s pioneer<strong>in</strong>g work <strong>in</strong><br />

the field of silicon-based NDIR<br />

technology and electrically tunable<br />

filters resulted <strong>in</strong> the compact,<br />

simple and high-performance<br />

CARBOCAP sensor. To this day, the<br />

long-term stability and reliability of<br />

the measurement provided by the<br />

FPI is unrivaled.<br />

The first commercial CARBOCAP<br />

products for measur<strong>in</strong>g ppm-level<br />

CO 2<br />

<strong>in</strong> ventilation applications<br />

were launched <strong>in</strong> 1997, with<br />

<strong>in</strong>struments for percentage-level<br />

CO 2<br />

measurements follow<strong>in</strong>g soon<br />

after. CARBOCAP technology<br />

is proven <strong>in</strong> a wide range of<br />

applications, <strong>in</strong>clud<strong>in</strong>g ecological<br />

measurements, where it performs<br />

reliably <strong>in</strong> harsh environments such<br />

as s<strong>oil</strong> and snow, satisfy<strong>in</strong>g the<br />

thirst for knowledge that scientists<br />

have for understand<strong>in</strong>g nature’s<br />

processes.<br />

For more <strong>in</strong>formation, visit<br />

www.vaisala.com or contact<br />

us at sales@vaisala.com<br />

Ref. B210780EN-C ©<strong>Vaisala</strong> 2012<br />

This material is subject to copyright protection, with all copyrights<br />

reta<strong>in</strong>ed by <strong>Vaisala</strong> and its <strong>in</strong>dividual partners. All rights reserved.<br />

Any logos and/or product names are trademarks of <strong>Vaisala</strong> or<br />

its <strong>in</strong>dividual partners. The reproduction, transfer, distribution or<br />

storage of <strong>in</strong>formation conta<strong>in</strong>ed <strong>in</strong> this brochure <strong>in</strong> any form<br />

without the prior written consent of <strong>Vaisala</strong> is strictly prohibited.<br />

All specifications — technical <strong>in</strong>cluded — are subject to change<br />

without notice.<br />

119

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!