Technical Data<br />

HMI41 Indicator<br />

Calculated variables <strong>dew</strong> <strong>po<strong>in</strong>t</strong> temperature, absolute <strong>humidity</strong>,<br />

wet bulb temperature, mix<strong>in</strong>g ratio<br />

Resolution<br />

0.1 %RH; 0.1 °C/°F<br />

Power supply 4 batteries, type AA (LR 6)<br />

Battery operation time<br />

(alkal<strong>in</strong>e batteries)<br />

72 h cont<strong>in</strong>uous use<br />

Auto-off function<br />

Operat<strong>in</strong>g temperature<br />

-20 ... +60 °C (-4 ... +140 °F)<br />

Storage temperature<br />

-40 ... +70 °C (-40 ... +158 °F)<br />

Display<br />

two l<strong>in</strong>e LCD<br />

Hous<strong>in</strong>g material<br />

ABS plastic<br />

Hous<strong>in</strong>g classification<br />

IP53 (with connectors blocked)<br />

Weight (<strong>in</strong>cl. batteries)<br />

300 g<br />

Maximum measurement error of <strong>in</strong>dicator at +20 °C<br />

<strong>humidity</strong><br />

±0.1 %RH<br />

temperature<br />

±0.1 °C (±0.18 °F)<br />

HMP42 Probe<br />

Humidity<br />

Measurement range<br />

0 ... 100 %RH<br />

Accuracy (<strong>in</strong>cl. non-l<strong>in</strong>earity, hysteresis and repeatability)<br />

at +20 °C (+68 °F)<br />

0 … 90 %RH ±2 %RH<br />

90 … 100 %RH ±3 %RH<br />

Factory calibration uncerta<strong>in</strong>ty (+20 °C / +68 °F)<br />

0 … 15 %RH ±1 %RH<br />

15 … 78 %RH ±1.5 %RH<br />

Temperature dependence of electronics<br />

±0.05 %RH/°C<br />

Typical long-term stability<br />

better than 1 %RH per year<br />

Response time (90%) at +20 °C <strong>in</strong> still air<br />

30 s<br />

Temperature<br />

Measurement range HMP42 -40 ... +100 °C (-40 ... +212 °F)<br />

Temperature accuracy over measurement range<br />

∆°C<br />

0.6<br />

0.4<br />

0.2<br />

0<br />

-0.2<br />

-0.4<br />

-0.6<br />

-40 -20 0 20 40 60 80 100<br />

T/°C<br />

Temperature sensor Pt100 RTD Class F0.3 IEC 60751<br />

HMP46 Probe<br />

Humidity<br />

Measurement range<br />

0 ... 100 %RH, non-condens<strong>in</strong>g<br />

Accuracy (<strong>in</strong>cl. non-l<strong>in</strong>earity, hysteresis and repeatibility)<br />

at +20 °C (+68 °F)<br />

0 … 90 %RH ±1 %RH<br />

90 … 100 %RH ±2 %RH<br />

Factory calibration uncerta<strong>in</strong>ty (+20 °C / +68 °F)<br />

0 … 15 % RH ±1 %RH<br />

15 … 78 %RH ±1.5 %RH<br />

Temperature Dependence<br />

error %RH<br />

2<br />

1.5<br />

1<br />

for temporary<br />

0.5<br />

0<br />

use only<br />

-0.5<br />

-1<br />

-1.5<br />

-2<br />

-40 -20 0 20 40 60 80 100 120 140 160 180<br />

T/°C<br />

Typical long-term stability<br />

better than 1 %RH per year<br />

Response time (90%)<br />

at +20 °C <strong>in</strong> still air w/s<strong>in</strong>tered filter<br />

15 s<br />

Temperature<br />

Cont<strong>in</strong>uous measurement<br />

-40 ... +100 °C (-40 ... +212 °F)<br />

Short-term measurement<br />

-40 ... +180 °C (-40 ... +356 °F)<br />

Temperature accuracy at +20 °C (+68 °F) ±0.2 °C (±0.36 °F)<br />

Temperature accuracy over the measurement range<br />

°C<br />

0.6<br />

0.4<br />

0.2<br />

0<br />

-0.2<br />

-0.4<br />

-0.6<br />

-40 -20 0 20 40 60 80 100 120 140 160 180<br />

T/°C<br />

Temperature sensor Pt100 RTD Class F0.1 IEC 60751<br />

Humidity<br />

57