Technical Data<br />

Dew<strong>po<strong>in</strong>t</strong> Temperature<br />

Measurement range<br />

-40 ... +100 °C (-40 … +212 °F)<br />

Accuracy: f<strong>in</strong>d the <strong>in</strong>tersection of the <strong>dew</strong><strong>po<strong>in</strong>t</strong> temperature<br />

curve and the <strong>dew</strong><strong>po<strong>in</strong>t</strong> difference read<strong>in</strong>g (process temperature<br />

- <strong>dew</strong><strong>po<strong>in</strong>t</strong> temperature) on the x-axis and read the accuracy <strong>in</strong><br />

<strong>dew</strong><strong>po<strong>in</strong>t</strong> measurement at the y-axis<br />

Outputs<br />

Two standard outputs, third optional<br />

Typical accuracy of analog output<br />

at +20 °C (+68 °F)<br />

Typical temperature dependence<br />

of analog output<br />

Serial output available<br />

0...20 mA, 4...20 mA,<br />

0 ... 1 V, 0...5 V, 0 ... 10 V<br />

±0.05 % full scale<br />

±0.005 %/°C full scale<br />

RS232C (optional RS485)<br />

Humidity<br />

Dimensions<br />

Dimensions <strong>in</strong> mm (<strong>in</strong>ches)<br />

254 (10)<br />

203 (8)<br />

Ø 13 (0.51)<br />

91.5 (3.6)<br />

144.5 (5.69)<br />

101.6 (4)<br />

100 (3.94)<br />

Response time (90 %) at +20 °C (68 °F)<br />

<strong>in</strong> still air (PPS grid with steel nett<strong>in</strong>g)<br />

Sensor<br />

20 s<br />

HUMICAP ® 180C<br />

441.5 (17.38)<br />

100 (3.94)<br />

488 (19.21)<br />

General<br />

Connections screw term<strong>in</strong>als for 0.5 mm 2 wires (AWG 20),<br />

stranded wires recommended<br />

Operat<strong>in</strong>g voltage 24 VDC/VAC (20...28 V) or 115/230 VAC<br />

(Must be specified at time of order) 254 (10)<br />

Recommended external load for current outputs < 500 ohm<br />

0...1 V output > 2 kohm (to ground) 203 (8)<br />

0...5 & 0...10 V outputs > 10 kohm (to ground)<br />

Operat<strong>in</strong>g temperature range for<br />

electronics<br />

-40...+60 °C (-40 ... +140 °F)<br />

101.6 (4)<br />

Storage temperature<br />

-55...+80 °C (-67 ... +176 °F)<br />

Hous<strong>in</strong>g material G-AlSi10 (DIN 1725)<br />

Hous<strong>in</strong>g classification IP65 (NEMA 4)<br />

Bush<strong>in</strong>g<br />

8...11 mm diameter cables (0.31 ... 0.43 <strong>in</strong>ch)<br />

Humidity sensor protection (Ø 12 mm) PPS grid with steel nett<strong>in</strong>g 100 (3.94)<br />

Weight:<br />

HMT300TMK with HMT337<br />

8,7 kg<br />

HMT300TMK with HMT337,<br />

packed <strong>in</strong> a wooden shipp<strong>in</strong>g box<br />

13,3 kg<br />

Electromagnetic compatibility Complies with EMC standard<br />

EN61326-1, Industrial Environment<br />

441.5 (17.38)<br />

144.5 (5.69)<br />

Ø 13 (0.51)<br />

91.5 (3.6)<br />

100 (3.94)<br />

488 (19.21)<br />

165.3 (6.51)<br />

HUMICAP ® is a registered trademark of <strong>Vaisala</strong>.<br />

193 (7.6)<br />

354.9 (13.97)<br />

www.vaisala.com<br />

Please contact us at<br />

www.vaisala.com/request<strong>in</strong>fo<br />

Scan the code for<br />

more <strong>in</strong>formation<br />

Ref. B210680EN-C ©<strong>Vaisala</strong> 2011<br />

This material is subject to copyright protection, with all<br />

copyrights reta<strong>in</strong>ed by <strong>Vaisala</strong> and its <strong>in</strong>dividual partners. All<br />

rights reserved. Any logos and/or product names are trademarks<br />

of <strong>Vaisala</strong> or its <strong>in</strong>dividual partners. The reproduction, transfer,<br />

distribution or storage of <strong>in</strong>formation conta<strong>in</strong>ed <strong>in</strong> this brochure<br />

<strong>in</strong> any form without the prior written consent of <strong>Vaisala</strong> is strictly<br />

prohibited. All specifications — technical <strong>in</strong>cluded — are subject<br />

to change without notice.<br />

73

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!