Industrial Products Catalogue - Passerotti sp. z oo
Industrial Products Catalogue - Passerotti sp. z oo
Industrial Products Catalogue - Passerotti sp. z oo
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
M<br />
Note: The natural frequencies and degrees of isolation are based on dynamic characteristics of the mountings.<br />
Load per mounting (kg)<br />
M25 – M1500<br />
3000<br />
2500<br />
2000<br />
Diagram 1<br />
Diagram 2<br />
M 1500-60<br />
1500<br />
1000<br />
M 1500-60<br />
800<br />
700<br />
600<br />
500<br />
400<br />
300<br />
M 1500-40<br />
M 600-40<br />
M 600-60<br />
M 400-60<br />
M 600-60<br />
M 400-60<br />
M 1500-40<br />
200<br />
150<br />
100<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
15<br />
Load per mounting (kg)<br />
M7<br />
10<br />
98<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1.5<br />
M 400-40<br />
M 200-60<br />
M 100-60<br />
M 200-40<br />
M 100-40<br />
M 50-60<br />
M 25-60<br />
M 50-40<br />
M 7-60<br />
M 7-40<br />
M 200-60<br />
M 100-60<br />
M 50-60 M 200-40<br />
M 25-60<br />
M 100-40<br />
M 50-40<br />
M 25-40<br />
M 600-40<br />
M 400-40<br />
M 7-60<br />
M 7-40<br />
10<br />
2<br />
Interfering frequency (Hz)<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
10<br />
15<br />
1<br />
3<br />
4<br />
Resonance<br />
5<br />
6<br />
M 25-40<br />
7 8 9 10 12 14 16 18 20<br />
Natural frequency (Hz)<br />
Diagram 3<br />
Avoid this region<br />
2<br />
3<br />
4<br />
5 6 7 8 910<br />
12 14 16 20 25 30<br />
M7 A, M7 B 1 2 2.5 3<br />
Static deflection (mm)<br />
40<br />
4<br />
50<br />
5<br />
To select correct mounting, following<br />
data are needed:<br />
1) Load per mounting (kg)<br />
2) Interfering frequency (Hz)<br />
(Hz = rpm / 60 )<br />
Select correct load line in diagram 1 and<br />
correct interference line in diagram 3.<br />
The load line intersects with required type<br />
of mounting.<br />
Connect this intersection point vertically<br />
down to the interference line in diagram 3.<br />
Here, on the sloping curve, the isolation<br />
degree is indicated.<br />
For static deflection, see diagram 2.<br />
20<br />
25<br />
30<br />
40<br />
50<br />
60<br />
70<br />
80<br />
100<br />
0<br />
50<br />
70<br />
80<br />
85<br />
90<br />
Degree of isolation (%)<br />
L<br />
I<br />
1<br />
3<br />
2<br />
Trelleborg <strong>Industrial</strong> AVS operates a policy of continuous improvement and development. We reserve the right to change design and <strong>sp</strong>ecifi cation of our products without prior notifi cation or alteration of literature<br />
33