19.01.2015 Views

Industrial Products Catalogue - Passerotti sp. z oo

Industrial Products Catalogue - Passerotti sp. z oo

Industrial Products Catalogue - Passerotti sp. z oo

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Metacone & HK<br />

Note: The natural frequencies and degrees of isolation are based on dynamic characteristics of the mountings.<br />

Load<br />

per mounting (kg)<br />

500<br />

400<br />

350<br />

17-0341-70<br />

Diagram 1<br />

Diagram 2<br />

300<br />

250<br />

200<br />

180<br />

160<br />

140<br />

120<br />

100<br />

80<br />

70<br />

60<br />

50<br />

40<br />

30<br />

25<br />

20<br />

17-0341-60<br />

17-0311-60<br />

HK 60-60<br />

17-0277-60<br />

17-0341-45<br />

HK 60-40<br />

17-0277-45<br />

17-0311-45<br />

HK 60-70<br />

17-0189-70<br />

17-0248-60<br />

17-1691-60<br />

17-0189-45<br />

17-0241-60<br />

HK 60-50<br />

17-0248-45<br />

17-0379-60<br />

17-1691-45<br />

17-0241-45<br />

17-0379-45<br />

17-0189-70<br />

17-0341-70<br />

HK 60-70<br />

17-0248-60 and 17-0341-60<br />

17-1691-60 17-0189-45 and HK 60-60<br />

17-0241-60<br />

17-0248-45 and 17-0341-45 HK 60-50<br />

17-0379-60 and 17-1691-45 HK 60-40<br />

17-0241-45<br />

17-0379-45<br />

17-0311-60<br />

17-0277-60<br />

17-0311-45<br />

17-0277-45<br />

15<br />

10<br />

6<br />

7 8 9 10<br />

Interfering<br />

6<br />

7<br />

frequency<br />

8<br />

10<br />

(Hz)Resonance<br />

12<br />

15<br />

20<br />

11<br />

12 13 14 15 16 17 18 20<br />

Natural frequency (Hz)<br />

Diagram 3<br />

Avoid this region<br />

1<br />

2 3 4 5<br />

Static deflection (mm)<br />

6 7 8<br />

To select correct mounting, following<br />

data are needed:<br />

1) Load per mounting (kg)<br />

2) Interfering frequency (Hz)<br />

(Hz = rpm / 60 )<br />

Select correct load line in diagram 1 and<br />

correct interference line in diagram 3.<br />

The load line intersects with required type<br />

of mounting.<br />

Connect this intersection point vertically<br />

down to the interference line in diagram 3.<br />

Here, on the sloping curve, the isolation<br />

degree is indicated.<br />

For static deflection, see diagram 2.<br />

25<br />

30<br />

40<br />

50<br />

60<br />

70<br />

80<br />

90<br />

100<br />

0<br />

50<br />

70<br />

80<br />

85<br />

90<br />

L<br />

I<br />

1 2<br />

3<br />

Degree of isolation (%)<br />

Trelleborg <strong>Industrial</strong> AVS operates a policy of continuous improvement and development. We reserve the right to change design and <strong>sp</strong>ecifi cation of our products without prior notifi cation or alteration of literature<br />