BA & Double U-Shear<br />

Note: The natural frequencies and degrees of isolation are based on dynamic characteristics of the mountings.<br />

Load<br />

per mounting (kg)<br />

300<br />

250<br />

200<br />

Diagram 1<br />

Diagram 2<br />

150<br />

17-1479-50<br />

BA 100 B<br />

120<br />

100<br />

90<br />

80<br />

70<br />

60<br />

50<br />

40<br />

30<br />

25<br />

20<br />

15<br />

12<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

17-1479-40<br />

17-1480-40<br />

17-1482-40<br />

17-1492-40<br />

17-1480-50<br />

BA 50 A<br />

17-1482-50<br />

17-1492-50<br />

BA 100 A<br />

BA 50 B<br />

BA 20 A<br />

BA 20/2 A<br />

BA 20 B<br />

BA 20/2 B<br />

BA 20 A<br />

17-1482-50<br />

BA 20/2 B<br />

17-1482-40<br />

BA 20 A<br />

BA 100 B<br />

17-1479-50<br />

BA 50 B<br />

17-1479-40<br />

17-1480-50<br />

BA 50 A<br />

17-1480-40<br />

17-1492-50<br />

17-1492-40<br />

BA 100 A<br />

BA 20/2 A<br />

4<br />

5<br />

Interfering frequency (Hz)<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

15<br />

20<br />

6<br />

7<br />

8<br />

Resonance<br />

9<br />

10<br />

11 12 13 14 16 18 20<br />

Natural frequency (Hz)<br />

Diagram 3<br />

Avoid this region<br />

1<br />

2 3 4 5 6<br />

Static deflection (mm)<br />

7 8 910<br />

To select correct mounting, following<br />

data are needed:<br />

1) Load per mounting (kg)<br />

2) Interfering frequency (Hz)<br />

(Hz = rpm / 60 )<br />

Select correct load line in diagram 1 and<br />

correct interference line in diagram 3.<br />

The load line intersects with required type<br />

of mounting.<br />

Connect this intersection point vertically<br />

down to the interference line in diagram 3.<br />

Here, on the sloping curve, the isolation<br />

degree is indicated.<br />

For static deflection, see diagram 2.<br />

25<br />

30<br />

40<br />

0<br />

50<br />

70<br />

L<br />

1<br />

2<br />

50<br />

60<br />

70<br />

80<br />

90<br />

100<br />

Degree of isolation (%)<br />

80<br />

85<br />

90<br />

I<br />

3<br />

Trelleborg <strong>Industrial</strong> AVS operates a policy of continuous improvement and development. We reserve the right to change design and <strong>sp</strong>ecifi cation of our products without prior notifi cation or alteration of literature<br />

39