Flow Control<br />

Call 1-877-853-9755<br />

Miniature Systems for<br />

Continuous Solutions Delivery<br />

Modular Design<br />

Manual Units and Computerized Systems<br />

Compatible with Imaging & Data Acquisition systems<br />

No electrical noise during operation<br />

Bath Perfusion & Local Application<br />

Works with Temperature Controlled Systems<br />

Flow Control Unit, 8 µl/min to 7.3 ml/min<br />

This is a perfusion system for precise solution flow rate linear control over the range from 8 µl/min to 7.3<br />

ml/min. Precision design and miniature size minimize pulsations to provide smooth perfusion. Easy to wash<br />

and replace tubing. No contamination, no solution comes into contact with the device. Designed for stable<br />

solution perfusion/infusion or substance application during imaging, recording, calcium and other ions measurement,<br />

biochemical assays or small organs and animals perfusion. Can be used with perfusion chambers,<br />

lab-on-chips, imaging chambers, miniature incubators, and small organs and animals micro-perfusion setups.<br />

All metal body design eliminates electrical noise.<br />

Ten-turn dials (or analog inputs) allow to calibrate the unit to apply a single or multiple substances using<br />

manual or analog signal control through a data acquisition or imaging software. Note: the analog option will<br />

have a BNC connector in front, instead of the 10-turn dial. The analog units can be operated by our computerized<br />

flow controllers. The unit can operate as a 2-channel system, if a dual-tubing set is used. Can be used<br />

to apply multiple solutions, if linked to our automated perfusion systems. Includes a power supply. Can be<br />

also powered by 12V batteries through an optional battery connection cable. Power rating: 0.75W. The size<br />

of the unit is 1.40 x 2.0 x 3.2 in. Multiple units can be attached to each other to form a multi-channel system<br />

(mounting hardware is included). You can accurately mix different solutions or generate dose-response<br />

curves using only two solutions: control and concentrated test compound. You can even generate concentration<br />

gradients in time to simulate substance distribution in time, and concentration gradients throughout the<br />

space of small chambers to assess chemotaxis and cell migration (an optional mixing chamber is required to<br />

generate concentration gradients in space).<br />