Climate control
Climate control
Climate control
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Overview ................. 0<br />
<strong>Climate</strong> <strong>control</strong><br />
Cabinets.................. 1<br />
<strong>Climate</strong> Control....... 2<br />
Cases ...................... 3<br />
Subracks/<br />
19" chassis............. 4<br />
High air capacity<br />
Can be adapted on subracks<br />
Modules .................. 5<br />
Systems .................. 6<br />
Power supply<br />
units........................ 7<br />
Backplanes ............. 8<br />
For indoor and outdoor applications<br />
Microcomputer <strong>control</strong>led<br />
Accessories ............ 9<br />
Appendix............... 10<br />
2.0 UK 08/2003<br />
For further information ... www.schroff.biz
<strong>Climate</strong> <strong>control</strong><br />
Overview<br />
.............. 2.0<br />
Service ................. 2.2<br />
Degree of protection IP 54<br />
Easy to mount – clip in<br />
19"-fan units........ 2.4<br />
Air filtered fans .. 2.16<br />
Heat exchanger.. 2.24<br />
Accessories<br />
Heaters . . . . . . . . . . 2.26<br />
Fans . . . . . . . . . . . . 2.29<br />
Speed <strong>control</strong> . . . . . 2.31<br />
Thermostat . . . . . . . 2.32<br />
Hygrostat . . . . . . . . 2.34<br />
With or without fan<br />
Quick and easy to mount<br />
Cooling concept with Flowtherm simulation<br />
Calculation aid on the internet<br />
For further information ... www.schroff.biz<br />
UK 08/2003<br />
2.1
Overview ................. 0<br />
<strong>Climate</strong> Control – Service – Overview<br />
Cabinets.................. 1<br />
‘FLOTHERM’ Simulation<br />
Project support through<br />
simulation software<br />
<strong>Climate</strong> Control....... 2<br />
Cases ...................... 3<br />
Subracks/<br />
19" chassis............. 4<br />
With the simulation software ’FLOTHERM’ heat field and problem<br />
areas can be recognised during the concept phase. Cooling<br />
concepts for assemblies up to total cases and cabinet systems can<br />
be analysed. Our ’FLOTHERM’ specialists will assist you in<br />
simulating your design.<br />
Your advantage:<br />
You analyse and remove problems in advance during<br />
the prototype phase<br />
You therefore increase the performance and the reliability<br />
of your system<br />
You shorten your development times<br />
Modules .................. 5<br />
Systems .................. 6<br />
Power supply<br />
units........................ 7<br />
Backplanes ............. 8<br />
01103050<br />
RESULT:<br />
Cost savings<br />
Your input:<br />
Capacity loss of the various components<br />
(units, boards, ...)<br />
Environmental and working conditions (outside temperature,<br />
maximum inside temperature)<br />
System assembly (geometry)<br />
RESULT:<br />
Joint establishment of the thermal analysis<br />
Optimum arrangement of components<br />
Accessories ............ 9<br />
01103051<br />
Appendix............... 10<br />
Further important information can be found on the internet<br />
under www.schroff.biz<br />
2.2 UK 04/2003<br />
For further information ... www.schroff.biz
<strong>Climate</strong> Control – Service – Overview<br />
Overview .............. 2.2<br />
Cooling Concepts with Standard Products<br />
<strong>Climate</strong> <strong>control</strong> of Cabinets<br />
and Cases<br />
Specific heat removal<br />
from systems<br />
19" fan units<br />
19" blower units<br />
01102050 0092050 01102051<br />
Air filtered fans<br />
Heat exchanger/<br />
Air conditioners<br />
V ° (m 3 /h)<br />
V ° (m 3 /h)<br />
Configuration in the Internet (www.schroff.biz)<br />
On our home page on the internet you will find assistance when<br />
selecting standard components.<br />
Describe your basic requirements by stating the following:<br />
installed heat loss<br />
requested temperature inside the cabinet<br />
Configuration<br />
via the Internet<br />
P V (W)<br />
A41771<br />
maximum outside temperature at the installation site<br />
type of installation<br />
and we will direct you to possible alternatives from our standard<br />
program.<br />
For further information ... www.schroff.biz<br />
UK 04/2003<br />
2.3
Overview ................. 0<br />
<strong>Climate</strong> <strong>control</strong> – 19"-fan units<br />
Cabinets.................. 1<br />
<strong>Climate</strong> Control....... 2<br />
Cases ...................... 3<br />
Subracks/<br />
19" chassis............. 4<br />
Modules .................. 5<br />
01102012<br />
Systems .................. 6<br />
Power supply<br />
units........................ 7<br />
Mechanical safety device<br />
for power lead<br />
01197002<br />
Configure the 19" fan units<br />
individually<br />
01194004<br />
Backplanes ............. 8<br />
Accessories ............ 9<br />
Appendix............... 10<br />
Standards<br />
19" mounting to IEC 60297-3<br />
Mechanical protection according to EN 292<br />
Touch protection according to EN 294<br />
Electrical safety according to EN 60335 part 1<br />
Modifications<br />
Other air capacities<br />
DC voltages<br />
Filter mats<br />
Other dimensions<br />
Further important information can be found on the internet<br />
under www.schroff.biz<br />
Configurator 19“fan units<br />
2.4 UK 08/2003<br />
For further information ... www.schroff.biz
<strong>Climate</strong> <strong>control</strong> – 19"-fan units<br />
19"-fan units........ 2.4<br />
19" fan units<br />
Removal of heat by 19" fan units<br />
High running performance<br />
Mechanical touch protection<br />
Adaption to subrack possible<br />
With or without switch<br />
19" Blowers<br />
For Cooling of single components and assemblies<br />
Height 1 U<br />
19" fan units<br />
1 U with/without front<br />
switch ........................2.8<br />
1 U, speed-<strong>control</strong>led<br />
and monitored .........2.10<br />
Individual configurations can be assembled with the help of the<br />
configurator on our homepage (www.schroff.biz)<br />
01102052<br />
19"-Pressure fans<br />
For Cooling of single components and assemblies<br />
Height 2 U and 3 U<br />
19" blower unit<br />
2 U with<br />
tangential fan ..........2.11<br />
2 U (160, 220 mm<br />
deep)........................2.12<br />
Supplementary fan<br />
for 2 U fan unit.........2.13<br />
3 U............................2.14<br />
Ventilation panel<br />
for 3 U ......................2.15<br />
01102053<br />
V ° (m 3 /h)<br />
Selection Guide<br />
Selection guide<br />
Versions .....................2.6<br />
Dimensions ................2.7<br />
P V (W)<br />
A41771<br />
For further information ... www.schroff.biz<br />
UK 08/2003<br />
2.5
<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />
19" fan versions<br />
Fan for assembly in the 19" mounting space<br />
High air throughput<br />
Long service life<br />
Tested and approved<br />
The 19" fans are available in two versions:<br />
19" blower unit<br />
01192002<br />
19" fan unit<br />
19" blower unit<br />
19" subracks with 160 or 220 mm standard board format are given<br />
optimum cooling by means of blower units, even if several<br />
subracks (each with blower units) are mounted one above the<br />
other.<br />
01192006<br />
19" fan unit<br />
These fans extract the heat from plug-in units and are available<br />
with or without illuminated switches. A low-noise version works<br />
with temperature-dependent speed <strong>control</strong> and its function is<br />
monitored. 19" fan units can also be configured individually<br />
(www.schroff.biz).<br />
Service life<br />
The service life of the fans depends on the way they are used. At<br />
an ambient temperature of 40 °C, it is approx. 40000 – 60000<br />
hours.<br />
01102016<br />
Standards<br />
19" mounting complying with IEC 60 297-3-101. Plastics are selfextinguishing<br />
to comply with UL 94 V 1. PPO and fibreglass<br />
reinforced plastics are self-extinguishing to comply with<br />
UL 94 V-0. Mechanical protection in accordance with EN 292.<br />
Contact protection in accordance with EN 294. Electrical safety in<br />
accordance with EN 60335, Part 1.<br />
19" fan racks<br />
2.6<br />
UK 08/2003<br />
For further information ... www.schroff.biz
<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />
19" fan dimensions<br />
V (m 3 /h)<br />
19" blower unit<br />
19" fan unit<br />
For local heat dissipation, the airflow volume required to extract<br />
the (energy loss) heat is calculated.<br />
P v (W)<br />
A41771<br />
Note<br />
The cabinet ventilation is not taken into account here.<br />
The required airflow volume is calculated as follows:<br />
V= (f x P v ) / T<br />
The air constant f = 3.3 mm 3 K/Wh.<br />
T is the difference between the ambient temperature and the<br />
internal temperature.<br />
Example<br />
- Pv = 600 W<br />
- internal temperature = 25 °C<br />
- ambient temperature = 30 °C<br />
1. T = T i – T a = 30 °C – 25 °C = 5 K<br />
2. From P v = 600 W for curve for T =5 K<br />
3. From the point of intersection down to the airflow volume<br />
V = 400 m 3 /h<br />
19" fan racks<br />
For further information ... www.schroff.biz<br />
UK 08/2003<br />
2.7
geprüfte<br />
Sicherheit<br />
<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />
19" fan unit 1 U<br />
19" fan racks<br />
Mechanical strain relief for mains cable<br />
Adaptation to subracks possible<br />
Contact protection in accordance with EN 294.<br />
Delivery comprises (assembled and wired)<br />
01194002<br />
Item Qty Description<br />
1 1 Front panel 1 U, aluminium 3 mm, anodised<br />
2 1 Case with grille, 1 mm steel, AIZn<br />
3 3 / 6 Fan, see ordering information<br />
4 1 IEC 320 input socket<br />
5 1 Safety device, mechanical strain relief for mains input<br />
cable<br />
6 1 Connection lead for 24 V DC supplied (please order<br />
separately for AC fan)<br />
Order Information<br />
230 V AC 115 V AC 24 V DC<br />
Order No. Order No. Order No.<br />
10713-100 10713-102 10713-103<br />
KTA44857<br />
10713-104 10713-106 10713-107<br />
KTA44306<br />
KTA44858<br />
Adapter bracket Subrack, europac to fan tray, incl.<br />
assembly parts<br />
21101-104<br />
Adapter bracket Subrack, europacPRO to fan tray, incl.<br />
assembly parts<br />
21101-954<br />
Equipment cable for AC fan, UTE, 2.5 m 60103-131<br />
Equipment cable for AC fan, British standard, 2.5 m 60103-137<br />
Equipment cable for AC fan, IEC, 2.5 m 60103-141<br />
Technical data of the individual fans<br />
Voltage 230 V AC 115 V AC 24 V DC<br />
Frequency in Hz 50 60 50 60 -<br />
Air capacity (free blowing) in m 3 /h 162 192 162 192 184<br />
Noise level per fan in dB (A) 37 41 37 41 42<br />
Max. stat. pressure in PA 73 88 73 88 68<br />
Max. ambient temperature in °C 70 70 70 70 70<br />
Power consumption in W 15 14 15 14 8<br />
Replacement fans, see chapter '<strong>Climate</strong> <strong>control</strong> - accessories'<br />
2.8<br />
UK 08/2003<br />
For further information ... www.schroff.biz
geprüfte<br />
Sicherheit<br />
<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />
19" fan unit 1 U<br />
with front switch<br />
19" fan racks<br />
Front mains switch plus additional mains output socket<br />
Mechanical strain relief for mains input and mains output cable<br />
Adaptation to subracks possible<br />
Contact protection in accordance with EN 294.<br />
Delivery comprises (assembled and wired)<br />
01194003<br />
Item Qty Description<br />
1 1 Front panel 1 U, aluminium 3 mm, anodised<br />
2 1 Case with grille, 1 mm steel, AIZn<br />
3 3 / 6 Fan, see ordering information<br />
4 1 IEC 320 input socket<br />
5 1 IEC 320 output connector<br />
6 2 Safety device, mechanical strain relief for mains cable<br />
7 1 Illuminated switch, green, plain for 24 V DC<br />
8 1 Connection lead for 24 V DC supplied (please order<br />
separately for AC fan)<br />
Order Information<br />
230 V AC 115 V AC 24 V DC<br />
Order no. Order no. Order no.<br />
01197002<br />
10713-108 10713-110 10713-111<br />
KTA44857<br />
10713-112 10713-114 10713-115<br />
KTA44858<br />
Adapter bracket Subrack, europac to fan tray, incl.<br />
assembly parts<br />
21101-104<br />
Adapter bracket Subrack, europacPRO to fan tray, incl.<br />
assembly parts<br />
21101-954<br />
Equipment cable for AC fan, UTE, 2.5 m 60103-131<br />
Equipment cable for AC fan, British standard, 2.5 m 60103-137<br />
Equipment cable for AC fan, IEC, 2.5 m 60103-141<br />
Equipment cable for power output, 2.5 m 60197-053<br />
KTA45963<br />
Technical data of the individual fans<br />
Voltage 230 V AC 115 V AC 24 V DC<br />
Frequency in Hz 50 60 50 60 -<br />
Air capacity (free blowing) in m 3 /h 162 192 162 192 184<br />
Noise level per fan in dB (A) 37 41 37 41 42<br />
Max. stat. pressure in PA 73 88 73 88 68<br />
Max. ambient temperature in °C 70 70 70 70 70<br />
Power consumption in W 15 14 15 14 8<br />
Replacement fans, see chapter '<strong>Climate</strong> <strong>control</strong> - accessories'<br />
For further information ... www.schroff.biz<br />
UK 08/2003<br />
2.9
<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />
19" fan 1 U,<br />
speed-<strong>control</strong>led and monitored<br />
19" fan racks<br />
Noise optimisation through temperature-dependent speed<br />
<strong>control</strong><br />
Temperature range selectable 20 ... 40 °C and 30 ... 50 °C<br />
External sensor (with sensor break max. speed.)<br />
Function monitoring with LEDs and via potential-free contacts<br />
Contact protection in accordance with EN 292.<br />
01198001<br />
Delivery comprises (assembled and wired)<br />
Item Qty Description<br />
1 1 Front panel 1 U, aluminium 3 mm, anodised<br />
2 1 Case with grille, 1 mm steel, AIZn<br />
3 3 DC-fan<br />
4 1 Connection lead, cable length 2.5 m, open end<br />
5 1 Temperature sensor, NTC resistor, cable length 1.5 m<br />
Order Information<br />
Description<br />
Order no.<br />
19" fan 1 U, speed-<strong>control</strong>led and monitored 10713-099<br />
Filter mat for 19" fan unit, 3 pieces, please order<br />
separately<br />
60713-169<br />
Control range<br />
KTA43398<br />
Technical data of the individual fans<br />
Voltage<br />
24 V DC<br />
Air capacity in m 3 /h 80...170<br />
Noise level per fan in dB (A) max. 45<br />
Max. stat. pressure in PA max. 70<br />
Max. ambient temperature in °C 65<br />
Power consumption in W 5.3<br />
Monitoring signal<br />
KTA43399<br />
Technical data Control / monitoring<br />
Control range Change-over switch from 20...40 °C to 30...50 °C<br />
Sensor<br />
External, NTC resistor, cable length 1.5 m<br />
Sensor connection Rear plug-in contact, with sensor break max.<br />
speed<br />
Signal for<br />
Speed 60, 20% nominal speed;<br />
switch-on delay 60, 4 s, signal delay 60, 1 s<br />
(see 'Monitoring signal')<br />
Signalling<br />
Display via LEDs<br />
Potential-free contact (changeover contact),<br />
power 20 W, voltage max. 100 V<br />
Open collector available on request<br />
For further information www.schroff.biz/oneClick<br />
oneClick code = Order no.<br />
n = speed, S = signal, n A = speed threshold value "alarm"<br />
KTA43400<br />
2.10<br />
UK 08/2003<br />
For further information ... www.schroff.biz
<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />
Blower unit 2 U<br />
with tangential fan<br />
19" fan racks<br />
High air capacity<br />
Integrated filter mat<br />
2 versions:<br />
- LE1: 19" full width<br />
- LE2: 19" reduced width, for easy assembly<br />
01192009<br />
Delivery comprises (assembled)<br />
Item Qty Description<br />
1 1 Front grille 2 U, PPO, UL 94 V-0<br />
2 1 Filter mat, fibre, filter class EU 2<br />
3 1 Case with grille, PA 6.6, UL 94 V-0<br />
4 1 Fans<br />
5 1 Terminal connection strip<br />
Order Information<br />
230 V AC 115 V AC<br />
Description Order no. Order no.<br />
LE 1 60713-001 60713-003<br />
LE 2 60713-002 60713-004<br />
Spare filter mat 10 pieces 20705-008<br />
Technical data<br />
A3532<br />
Voltage in V 230 V AC 115 V AC<br />
Frequency in Hz 50 60 50 60<br />
Air capacity in m 3 /h 300 310 300 310<br />
Noise level per fan in dB (A) 53 54 53 54<br />
Max. stat. pressure in PA 65 70 65 70<br />
Max. ambient temperature in °C 65 65 65 65<br />
Power consumption in W 40 50 40 50<br />
For further information www.schroff.biz/oneClick<br />
oneClick code = Order no.<br />
01103056<br />
For further information ... www.schroff.biz<br />
UK 08/2003<br />
2.11
<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />
19" blower unit 2U<br />
(160, 220 mm deep)<br />
19" fan racks<br />
Integrated air baffle prevents heat accumulation on plug-in units<br />
underneath<br />
Optional rear supplementary fan 2 U<br />
Adaptation to subracks possible<br />
01194005<br />
Delivery comprises (assembled and wired)<br />
Item Qty Description<br />
1 1 Front grille 2 U, PPO, UL 94 V-0<br />
2 1 Filter mat, fibre, filter class EU 2<br />
3 1 Case, 1 mm steel, AIZn<br />
4 3 Fan, see ordering information<br />
5 1 IEC 320 input socket<br />
6 1 Safety device, mechanical strain relief for mains input<br />
cable<br />
7 1 Equipment cable for 24 V DC supplied (please order<br />
separately for AC fan)<br />
01103054<br />
A3527V<br />
Order Information<br />
Voltage<br />
airflow capacity at 50/60 Hz<br />
230 V AC 230 V AC 115 V AC 115 V AC 24 V DC<br />
108/120 m 3 /h 162/192 m 3 /h 108/120 m 3 /h 162/192 m 3 /h 184 m 3 /h<br />
Type Order No. Order No. Order No. Order No. Order No.<br />
for board depth 160 mm 10713-518 10713-534 10713-520 10713-536 10713-537<br />
for board depth 220 mm – 10713-526 – 10713-528 10713-529<br />
Equipment cable for AC fan, UTE, 2.5 m 60103-131<br />
Equipment cable for AC fan, British standard, 2.5 m 6010<br />
Equipment cable for AC fan, IEC, 2.5 m 60103-141<br />
Adapter bracket Subrack, europac to fan tray, incl. assembly parts 21101-104<br />
Adapter bracket Subrack, europacPRO to fan tray, incl. assembly parts 21101-954<br />
Spare filter mat 3 pieces 60713-501<br />
Technical data<br />
of the individual fans<br />
Voltage 230 V AC 115 V AC 24 V DC<br />
Frequency in Hz 50 60 50 60 50 60 50 60 -<br />
Air capacity in m 3 /h 108 120 162 192 108 120 162 192 184<br />
Noise level per fan in dB (A) 34 38 37 41 34 38 37 41 42<br />
Max. stat. pressure in PA 41 41 73 88 41 41 73 88 88<br />
Max. ambient temperature in °C 70 70 70 70 70 70 70 70 70<br />
Power consumption in W 14 11 15 14 14 11 15 14 8<br />
2.12<br />
UK 08/2003<br />
For further information ... www.schroff.biz
geprüfte<br />
Sicherheit<br />
<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />
Supplementary fan for 2 U<br />
fan unit<br />
19" fan racks<br />
2 U mounting space:<br />
the use of the supplementary fan means that plug-in units<br />
beneath the 19" blower unit can be cooled<br />
No additional power supply necessary: connection via 19"<br />
blower unit, 2 U<br />
Delivery comprises<br />
01194006<br />
Item Qty Description<br />
1 1 Case with grille, 1 mm steel, AIZn<br />
2 4 Fans<br />
3 1 Connector (electrical connection via connector on the<br />
19" blower unit)<br />
4 1 Safety device (mechanical strain relief for mains input<br />
cable)<br />
Order Information<br />
230 V AC 115 V AC<br />
Description Order no. Order no.<br />
Supplementary fan for 2 U fan unit 10713-530 10713-532<br />
Technical data of the individual fans<br />
KTA44447<br />
Voltage 230 V AC 115 V AC<br />
Frequency in Hz 50 60 50 60<br />
Air capacity in m 3 /h 45 54 45 54<br />
Noise level per fan in dB (A) 33 38 33 38<br />
Max. stat. pressure in PA 44 63 44 63<br />
Max. ambient temperature<br />
70 70 70 70<br />
in °C<br />
Power consumption in W 10 8 10 8<br />
Replacement fans, see chapter '<strong>Climate</strong> <strong>control</strong> - accessories'<br />
For further information www.schroff.biz/oneClick<br />
oneClick code = Order no.<br />
01103055<br />
For further information ... www.schroff.biz<br />
UK 08/2003<br />
2.13
<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />
19" blower unit 3 U<br />
19" fan racks<br />
This blower unit can be re-equipped for different cooling concepts<br />
using cover plates<br />
Specific air supply to subracks<br />
Air supply in the rear cabinet area<br />
Connection options for hoses for specific air supply<br />
01102017<br />
Delivery comprises (assembled and wired)<br />
Item Qty Description<br />
1 1 perforated hinged front panel, 2.5 mm aluminium<br />
2 1 Filter mat, fibre, filter class G 2 complying with EN 779<br />
3 1 Case, 1 mm steel, AIZn<br />
4 1 Radial fan<br />
5 1 IEC 320 inlet socket<br />
6 1 Safety device, mechanical strain relief for mains input<br />
cable<br />
Order Information<br />
230 V AC 115 V AC<br />
Description Order no. Order no.<br />
19" blower unit 3 U<br />
Equipment cable, UTE, 2.5 m<br />
Equipment cable, British standard, 2.5 m<br />
Equipment cable, IEC, 2.5 m<br />
10713-546 10713-547<br />
60103-131<br />
60103-137<br />
60103-141<br />
Adapter bracket Subrack, europac to fan tray, incl.<br />
assembly parts<br />
21101-958<br />
Adapter bracket Subrack, europacPRO to fan tray, incl.<br />
assembly parts<br />
Spare filter mat 3 pieces<br />
21101-954<br />
60713-868<br />
Technical data<br />
01103052<br />
Voltage 230 V AC 115 V AC<br />
Frequency in Hz 50 60 50 60<br />
Air capacity in m 3 /h 570 620 570 615<br />
Noise level per fan in dB (A) 62 64 64 67<br />
Max. stat. pressure in PA 320 405 320 420<br />
Max. ambient temperature in °C 50 55 60 60<br />
Power consumption in W 58 75 57 81<br />
Fan trays for other cooling concepts, see next page 2.15<br />
For further information www.schroff.biz/oneClick<br />
oneClick code = Order no.<br />
2.14<br />
UK 08/2003<br />
For further information ... www.schroff.biz
<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />
Ventilation panel for<br />
19" blower unit 3 U<br />
19" fan racks<br />
For 19" blower unit 3 U<br />
Order Information<br />
Item Description Qty Order no.<br />
7 Front fan panel, 1 mm steel, AlZn 1 20713-504<br />
8<br />
Ventilation to rear side: top panel<br />
without perforation ,1 mm steel, AlZn<br />
1 20713-505<br />
9<br />
Ventilation panel with ducting<br />
connection at the top, 1 mm steel, AlZn 1 20713-503<br />
Ventilation panel with ducting<br />
10 connection at the rear, 1 mm steel,<br />
AlZn<br />
1 20713-502<br />
For further information www.schroff.biz/oneClick<br />
oneClick code = Order no.<br />
01102053<br />
For further information ... www.schroff.biz<br />
UK 08/2003<br />
2.15
Overview ................. 0<br />
<strong>Climate</strong> Control – Air filtered fans<br />
Cabinets.................. 1<br />
<strong>Climate</strong> Control....... 2<br />
Cases ...................... 3<br />
Subracks/<br />
19" chassis............. 4<br />
Modules .................. 5<br />
Systems .................. 6<br />
01102005<br />
Power supply<br />
units........................ 7<br />
Backplanes ............. 8<br />
Accessories ............ 9<br />
Improved EMC protection<br />
with EMC filter fans<br />
01102010 01102009<br />
01102011<br />
Easy changeover of operation for<br />
incoming to outgoing air<br />
Assembly simply<br />
by clipping into place<br />
Appendix............... 10<br />
Standards<br />
Protection to IP 54 according to IEC 60529<br />
Earthing according to IEC 60335-2-16<br />
Mechanical protection according to EN 292<br />
Touch protection according to EN 294<br />
Modificatons<br />
Special colour RAL 7032<br />
Other air capacities<br />
Other voltages<br />
Further important Information can be found on the internet<br />
under www.schroff.biz<br />
2.16 UK 08/2003<br />
For further information ... www.schroff.biz
<strong>Climate</strong> Control – Air filtered fans<br />
Overview ............ 2.16<br />
Removal of heat with the help of filtered fans<br />
Protection to IP 54<br />
Assembly simply by clipping into place<br />
Easy changeover of operation for incoming to outgoing air<br />
Flat front grille does not protrude more than 6 mm or 7 mm<br />
Air filtered fans<br />
Air filtered fans<br />
FL 100 ......................2.18<br />
FL 200 ......................2.19<br />
FL 250 ......................2.20<br />
FL 300 ......................2.21<br />
FL 500 ......................2.22<br />
FL 600 ......................2.23<br />
01102050<br />
Selection Guide<br />
KTA45245<br />
For further information ... www.schroff.biz<br />
UK 08/2003<br />
2.17
<strong>Climate</strong> <strong>control</strong> – Air filtered fan<br />
FL 100<br />
Air filtered fan FL 100<br />
Air filtered fan<br />
Simple conversion from pressure to suction mode<br />
Type of protection IP54<br />
Delivery comprises (completely assembled)<br />
Item Qty Description<br />
1 1 Front grille and case, plastic PC, RAL 7035,<br />
self-extinguishing, similar to UL 94 V-0<br />
2 1 Filter mat, 150 g/m 3 quality class EU 2<br />
3 1 Fan<br />
4 1 Connection, 2 wires 310 mm long<br />
5 1 Capacitor<br />
Order Information<br />
FLA 100<br />
KTA45979<br />
230 V AC 115 V AC 24 V DC<br />
Description Order no. Order no. Order no.<br />
Air filtered fan FL 100 60715-059 60715-061 60715-063<br />
Outlet/Inlet filterFLA 100<br />
(Delivery comprises items1 + 2), 1 piece<br />
60715-087<br />
Replacement filter for FL 100 / FLA 100,<br />
(Delivery comprises item 2), 3 pieces<br />
60715-094<br />
Technical data of the fan<br />
Voltage in V 230 115 24<br />
Frequency in Hz 50 / 60 50 / 60 DC<br />
Air capacity with filter<br />
24 24 24<br />
(free blowing ) in m 3 /h<br />
Combination FL + FLA in m 3 /h 15 15 15<br />
Noise level per fan in dB (A) 39 39 39<br />
Max. stat. pressure in PA 29 29 29<br />
Max. ambient temperature in °C -10...+60 -10...+60 -20...+60<br />
Power consumption in W 11 11 2.4<br />
Filter efficiency in % 67 67 67<br />
KTA46383<br />
For further information www.schroff.biz/oneClick<br />
Click<br />
oneClick code = Order no.<br />
2.18<br />
UK 08/2003<br />
For further information ... www.schroff.biz
<strong>Climate</strong> <strong>control</strong> – Air filtered fan<br />
FL 200<br />
Air filtered fan FL 200<br />
Air filtered fan<br />
Simple conversion from pressure to suction mode<br />
EMC design<br />
Type of protection IP54<br />
Delivery comprises (completely assembled)<br />
Item Qty Description<br />
1 1 Front grille and case, Plastic ABS, RAL 7035,<br />
self-extinguishing, similar to UL 94 V-0<br />
2 1 Filter mat, 350 g/m 3 quality class EU 2<br />
3 1 Fan<br />
4 1 Connection AC (2-pin terminal block)<br />
connection DC (2 wires, 310 mm long)<br />
5 1 Capacitor<br />
FLA 200<br />
KTA45978<br />
Order Information<br />
230 V AC 115 V AC 24 V DC<br />
Description Order no. Order no. Order no.<br />
Standard air filtered fan FL 200 60715-065 60715-067 60715-069<br />
Air filtered fan FL 200 EMC<br />
60715-102 60715-104 60715-106<br />
Outlet/Inlet filter FLA 200 Standard<br />
(Delivery comprises items 1 + 2), 1 piece<br />
60715-089<br />
Outlet/Inlet filter FLA 200 EMC<br />
(Delivery comprises items 1 + 2), 1 piece<br />
60715-124<br />
Replacement filter for FL 200 / FLA 200,<br />
(Delivery comprises item 2), 3 pieces<br />
60715-095<br />
KTA46384<br />
Technical data of the fan<br />
Voltage in V 230 115 24<br />
Frequency in Hz 50 / 60 50 / 60 DC<br />
Air capacity with filter<br />
56 56 56<br />
(free blowing ) in m 3 /h<br />
Combination FL + FLA in m 3 /h 42 42 42<br />
Noise level per fan in dB (A) 49 49 49<br />
Max. stat. pressure in PA 69 69 69<br />
Max. ambient temperature in °C -10...+50 -10...+50 -20...+50<br />
Power consumption in W 18 20 4.5<br />
Filter efficiency in % 83 83 83<br />
Note<br />
EMC version, assembly cut-out 2 mm larger (height, width)<br />
For further information www.schroff.biz/oneClick<br />
oneClick code = Order no.<br />
For further information ... www.schroff.biz<br />
UK 08/2003<br />
2.19
<strong>Climate</strong> <strong>control</strong> – Air filtered fan<br />
FL 250<br />
Air filtered fan FL 250<br />
Air filtered fan<br />
Simple conversion from pressure to suction mode<br />
EMC design<br />
Type of protection IP54<br />
Delivery comprises (completely assembled)<br />
Item Qty Description<br />
1 1 Front grille and case, Plastic ABS, RAL 7035,<br />
self-extinguishing, similar to UL 94 V-0<br />
2 1 Filter mat, 350 g/m 3 quality class EU 2<br />
3 1 Fan<br />
4 1 Connection (terminal block)<br />
5 1 Capacitor<br />
FLA 250<br />
KTA45980<br />
Order Information<br />
230 V AC 115 V AC<br />
Description Order no. Order no.<br />
Standard air filtered fan FL 250 60715-071 60715-073<br />
Air filtered fan FL 250 EMC 60715-108 60715-110<br />
Outlet/Inlet filter FLA 250/300 Standard<br />
(Delivery comprises items 1 + 2), 1 piece<br />
60715-091<br />
Outlet/Inlet filter FLA 250/300 EMC<br />
(Delivery comprises items 1 + 2), 1 piece<br />
60715-126<br />
Replacement filter for FL 250 / 300 / FLA 250 / 300,<br />
(Delivery comprises item 2), 3 pieces<br />
60715-096<br />
KTA46385<br />
Technical data of the fan<br />
Voltage in V 230 115<br />
Frequency in Hz 50 / 60 50 / 60<br />
Air capacity with filter (free blowing ) in m 3 /h 131 131<br />
Combination FL + FLA in m 3 /h 95 95<br />
Noise level per fan in dB (A) 55 55<br />
Max. stat. pressure in PA 57 57<br />
Max. ambient temperature in °C -10...+50 -10...+50<br />
Power consumption in W 18 20<br />
Filter efficiency in % 83 83<br />
Note<br />
EMC version, assembly cut-out 2 mm larger (height, width)<br />
For further information www.schroff.biz/oneClick<br />
oneClick code = Order no.<br />
2.20<br />
UK 08/2003<br />
For further information ... www.schroff.biz
<strong>Climate</strong> <strong>control</strong> – Air filtered fan<br />
FL 300<br />
Air filtered fan FL 300<br />
Air filtered fan<br />
Simple conversion from pressure to suction mode<br />
EMC design<br />
Type of protection IP54<br />
Delivery comprises (completely assembled)<br />
Item Qty Description<br />
1 1 Front grille and case, Plastic ABS, RAL 7035,<br />
self-extinguishing, similar to UL 94 V-0<br />
2 1 Filter mat, 350 g/m 3 quality class EU 2<br />
3 1 Fan<br />
4 1 Connection (terminal block)<br />
5 1 Capacitor<br />
FLA 300<br />
KTA45980<br />
Order Information<br />
230 V AC 115 V AC<br />
Description Order no. Order no.<br />
Standard air filtered fan FL 300 60715-075 60715-077<br />
Air filtered fan FL 300 EMC 60715-112 60715-114<br />
Outlet/Inlet filter FLA 250/300 Standard<br />
(Delivery comprises items 1 + 2), 1 piece<br />
60715-091<br />
Outlet/Inlet filter FLA 250/300 EMC<br />
(Delivery comprises items 1 + 2), 1 piece<br />
60715-126<br />
Replacement filter for FL 250 / 300 / FLA 250 / 300,<br />
(Delivery comprises item 2), 3 pieces<br />
60715-096<br />
KTA46385<br />
Technical data of the fan<br />
Voltage in V 230 115<br />
Frequency in Hz 50 / 60 50 / 60<br />
Air capacity with filter (free blowing ) in m 3 /h 249 249<br />
Combination FL + FLA in m 3 /h 210 210<br />
Noise level per fan in dB (A) 55 55<br />
Max. stat. pressure in PA 89 89<br />
Max. ambient temperature in °C -10...+50 -10...+50<br />
Power consumption in W 18 20<br />
Filter efficiency in % 83 83<br />
Note<br />
EMC version, assembly cut-out 2 mm larger (height, width)<br />
For further information www.schroff.biz/oneClick<br />
oneClick code = Order no.<br />
For further information ... www.schroff.biz<br />
UK 08/2003<br />
2.21
<strong>Climate</strong> <strong>control</strong> – Air filtered fan<br />
FL 500<br />
Air filtered fan FL 500<br />
Air filtered fan<br />
EMC design<br />
Type of protection IP54<br />
Available on request, can be converted at the factory from<br />
pressure to suction mode<br />
FLA 500<br />
KTA45981<br />
Delivery comprises (completely assembled)<br />
Item Qty Description<br />
1 1 Front grille and case, Plastic ABS, RAL 7035,<br />
self-extinguishing, similar to UL 94 V-0<br />
2 1 Filter mat, 350 g/m 3 quality class EU 2<br />
3 1 Fan<br />
4 1 Connection (terminal block)<br />
5 1 Capacitor<br />
Order Information<br />
230 V AC 115 V AC<br />
Description Order no. Order no.<br />
Standard air filtered fan FL 500 60715-079 60715-081<br />
Air filtered fan FL 500 EMC 60715-116 60715-118<br />
Outlet/Inlet filter FLA 500/600 Standard<br />
(Delivery comprises items 1 + 2), 1 piece<br />
60715-093<br />
Outlet/Inlet filter FLA 500/600 EMC<br />
(Delivery comprises items 1 + 2), 1 piece<br />
60715-128<br />
Replacement filter for FL 500/600 FLA 500/600,<br />
(Delivery comprises item 2), 3 pieces<br />
60715-097<br />
KTA46386<br />
Technical data of the fan<br />
Voltage in V 230 115<br />
Frequency in Hz 50 / 60 50 / 60<br />
Air capacity with filter (free blowing ) in m 3 /h 461 461<br />
Combination FL + FLA in m 3 /h 350 350<br />
Noise level per fan in dB (A) 69 69<br />
Max. stat. pressure in PA 205 205<br />
Max. ambient temperature in °C -10...+50 -10...+50<br />
Power consumption in W 56 56<br />
Filter efficiency in % 83 83<br />
Note<br />
EMC version, assembly cut-out 2 mm larger (height, width)<br />
For further information www.schroff.biz/oneClick<br />
oneClick code = Order no.<br />
2.22<br />
UK 08/2003<br />
For further information ... www.schroff.biz
<strong>Climate</strong> <strong>control</strong> – Air filtered fan<br />
FL 600<br />
Air filtered fan FL 600<br />
Air filtered fan<br />
EMC design<br />
Type of protection IP54<br />
Available on request, can be converted at the factory from<br />
pressure to suction mode<br />
FLA 600<br />
KTA45981<br />
Delivery comprises (completely assembled)<br />
Item Qty Description<br />
1 1 Front grille and case, Plastic ABS, RAL 7035,<br />
self-extinguishing, similar to UL 94 V-0<br />
2 1 Filter mat, 350 g/m 3 quality class EU 2<br />
3 1 Fan<br />
4 1 Connection (terminal block)<br />
5 1 Capacitor<br />
Order Information<br />
230 V AC 115 V AC<br />
Description Order no. Order no.<br />
Standard air filtered fan FL 600 60715-083 60715-085<br />
Air filtered fan FL 600 EMC 60715-120 60715-122<br />
Outlet/Inlet filter FLA 500/600 Standard<br />
(Delivery comprises items 1 + 2), 1 piece<br />
60715-093<br />
Outlet/Inlet filter FLA 500/600 EMC<br />
(Delivery comprises items 1 + 2), 1 piece<br />
60715-128<br />
Replacement filter for FL 500/600 FLA 500/600,<br />
(Delivery comprises item 2), 3 pieces<br />
60715-097<br />
KTA46386<br />
Technical data of the fan<br />
Voltage in V 230 115<br />
Frequency in Hz 50 / 60 50 / 60<br />
Air capacity with filter (free blowing ) in m 3 /h 625 625<br />
Combination FL + FLA in m 3 /h 450 450<br />
Noise level per fan in dB (A) 71 71<br />
Max. stat. pressure in PA 225 225<br />
Max. ambient temperature in °C -10...+50 -10...+50<br />
Power consumption in W 155 155<br />
Filter efficiency in % 83 83<br />
Note<br />
EMC version, assembly cut-out 2 mm larger (height, width)<br />
For further information www.schroff.biz/oneClick<br />
oneClick code = Order no.<br />
For further information ... www.schroff.biz<br />
UK 08/2003<br />
2.23
Overview ................. 0<br />
<strong>Climate</strong> <strong>control</strong> – Heat exchanger<br />
Cabinets.................. 1<br />
<strong>Climate</strong> Control....... 2<br />
Cases ...................... 3<br />
Subracks/<br />
19" chassis............. 4<br />
Modules .................. 5<br />
00902001<br />
Systems .................. 6<br />
Power supply<br />
units........................ 7<br />
Backplanes ............. 8<br />
Accessories ............ 9<br />
Appendix............... 10<br />
On the Internet further important information can be found<br />
under www.schroff.biz<br />
Ordering data<br />
Specifications about power dissipation<br />
Individual configuration, Download of drawings<br />
Modifications, customized solutions<br />
2.24 UK 08/2003<br />
For further information ... www.schroff.biz
<strong>Climate</strong> <strong>control</strong> – Heat exchanger<br />
Overview ............ 2.24<br />
Efficient heat dissipation for indoor and outdoor enclosures<br />
Low weight<br />
Compact dimensions<br />
Cooling devices with integrated evaporation of condensation water<br />
Heat exchanger<br />
Heat exchanger<br />
Indoor application<br />
Standard heat exchanger 230 V and 115 V<br />
Outdoor application<br />
For further information see www.schroff.biz<br />
01102013<br />
Cooling Units<br />
Cooling Units<br />
Indoor application<br />
Standard cooling devices 400 W to 2600 W<br />
Outdoor application<br />
For further information see www.schroff.biz<br />
00902001<br />
Micro<strong>control</strong>ler<br />
Micro<strong>control</strong>ler<br />
For <strong>control</strong> and supervision<br />
Diagnostic messages<br />
Potential free alarm outputs<br />
For further information see www.schroff.biz<br />
00902002<br />
W<br />
Selection Guide<br />
Selection Guide<br />
˚C<br />
KT6741<br />
For further information ... www.schroff.biz<br />
UK 08/2003<br />
2.25
<strong>Climate</strong> <strong>control</strong> – Accessories<br />
Heaters 20W up to 150W<br />
Accessories<br />
Simple and fast assembly with clip-on attachment<br />
Press-on terminal connection saves time on assembly<br />
Temperature-limiting<br />
Delivery comprises (fully assembled)<br />
01102004<br />
Item Qty Description<br />
1 1 Heater element, (PTC resistance)<br />
self-regulating voltage range 110-250 V AC/DC<br />
2 Heating body, anodised aluminium extrusion<br />
Assembly: clip for 35 mm rail EN 50022<br />
3 Connections for type HKG = lead 300 mm long 2 core<br />
0.75 mm 2<br />
Connections for type HG = Terminal block for<br />
3 x 0.5 - 0.25 mm 2 wire<br />
Order Information<br />
HGK 20 W HGK 30 W HG 45 W HG 75 W HG 100 W HG 150 W<br />
Description Order no. Order no. Order no. Order no. Order no. Order no.<br />
Heaters 20 W up to 150 W 60715-019 60715-020 60715-021 60715-022 60715-023 60715-030<br />
Support rail for heaters, 1 piece 20715-001<br />
Technical data<br />
Type HGK HGK HG HG HG HG<br />
Heater output in W 20 30 45 75 100 150<br />
Surface temperature in °C approx. 90 approx. 100 approx. 105 approx. 120 approx. 130 approx.140<br />
Current at switch-on approx. in A 1 1.5 1 1.8 2.4 4<br />
Type of protection IP 54 IP 54 IP 20 IP 20 IP 20 IP 20<br />
Class of protection II II I I I I<br />
Dimensions H × B × T in mm 60 × 50 × 25 70 × 50 × 25 65 × 70 × 25 140 × 70 × 25 140 × 70 × 25 220 × 70 × 25<br />
Weight in kg 0.11 0.12 0.3 0.5 0.5 0.8<br />
Test symbols VDE, CE VDE, CE CE CE CE CE<br />
For further information www.schroff.biz/oneClick<br />
z/oneClick<br />
oneClick code = Order no.<br />
2.26<br />
UK 08/2003<br />
For further information ... www.schroff.biz
<strong>Climate</strong> <strong>control</strong> – Accessories<br />
Heater 400 W<br />
Accessories<br />
With temperature <strong>control</strong><br />
Simple and fast assembly with clip-on attachment<br />
Fan freely selectable<br />
Delivery comprises (fully assembled)<br />
01197004<br />
Item Qty Description<br />
1 1 Heater element, high-performance cartridge<br />
2 1 Heating body, anodised aluminium extrusion<br />
Assembly: Clip for 35 mm rail EN 50022<br />
3 1 Terminal connection<br />
4 1 Assembly kit for fan<br />
Order Information<br />
115 V AC 230 V AC<br />
Description Order no. Order no.<br />
Heater 400 W 60715-028 60715-029<br />
Support rail for heaters, 1 piece 20715-001<br />
Protective grille optionally for fan, 1 piece 60197-019<br />
Technical data<br />
Voltage range 115 V AC 230 V<br />
Heater output in W 400 400<br />
Current at switch-on approx. in A 3.5 1.8<br />
Surface temperature with fan in °C approx.140<br />
Type of protection IP 20<br />
Class of protection<br />
I, with GND/earthing<br />
Dimensions:<br />
22 × 120 × 160<br />
Width x Height x Depth in mm<br />
Weight in kg 0.4<br />
Assembly Clip for 35 mm DIN rail EN 50022<br />
Note<br />
Only operate heater in conjunction with fan, danger of<br />
overheating<br />
Single fan (119 mm × 119 mm), see page 2.29<br />
For further information www.schroff.biz/oneClick<br />
oneClick code = Order no.<br />
For further information ... www.schroff.biz<br />
UK 08/2003<br />
2.27
<strong>Climate</strong> <strong>control</strong> – Accessories<br />
Heater 350/500 W with thermostat and<br />
fan<br />
Accessories<br />
Simple and fast assembly with clip-on attachment<br />
3-pin connecting terminal, separated connection heater/fan<br />
Thermostat from 0 ... 60 °C<br />
Delivery comprises (fully assembled)<br />
Item Qty Description<br />
1 1 Plastic housing, polycarbonate<br />
(RAL 9002, grey-white), clip for 35 mm rail EN 50022<br />
2 1 Heater element, ( PTC resistance), self-regulating<br />
3 1 Fans<br />
Order Information<br />
01197005<br />
Type Weight 115 V AC 230 V AC<br />
kg Order no. Order no.<br />
Heater 350 W 0.9 60715-015 60715-017<br />
Heater 500 W 1.1 60715-016 60715-018<br />
Support rail for heaters, 1 piece 20715-001<br />
Technical data<br />
Voltage range 115 V AC 230 V<br />
Heater output in W 350 550 350 550<br />
Air capacity axial fan m 3 /h 35 45 35 45<br />
Air exit temperature 50 mm<br />
above protective grille in °C<br />
Current at switch-on approx.<br />
in A<br />
Heater element<br />
approx.<br />
150<br />
approx.<br />
160<br />
approx.<br />
150<br />
10.5 12 7 8.5<br />
Resistor (PTC) self-regulating<br />
Connection 3-pin connecting terminal, 2.5 mm 2 ,<br />
separated connection heating/fan<br />
Thermostat Adjustment range 0 ... 60 °C<br />
Control system (<strong>control</strong> Glow lamp<br />
lamp)<br />
Temperature <strong>control</strong> in the event of fan failure<br />
Type of protection IP 00<br />
Class of protection II<br />
Dimensions: height x width x 165 x 100 x 124<br />
depth mm<br />
approx.<br />
160<br />
For further information www.schroff.biz/oneClick<br />
oneClick code = Order no.<br />
2.28<br />
UK 08/2003<br />
For further information ... www.schroff.biz
<strong>Climate</strong> <strong>control</strong> – Accessories<br />
AC fans / replacement fans<br />
Accessories<br />
Delivery comprises (Individual part)<br />
Item Qty Description<br />
1 1 Fans (width 119 mm, depth 119 mm)<br />
Order Information<br />
Connecting lead<br />
KTA44844<br />
Height<br />
Air capacity<br />
50 Hz, DC<br />
Power consumption<br />
50 Hz<br />
115 V AC 230 V AC<br />
Order no. Order no.<br />
mm m³/h W<br />
25 84 8 20713-146 20713-142<br />
25 108 14 20713-147 20700-001<br />
38 162 15 20713-244 20713-243<br />
Connecting lead PVC (2 x 0.75 mm²), 1 m long with 2 faston<br />
connectors 2.8 x 0.8 mm, 1 piece<br />
21101-246<br />
Protective grille bolt-on fibreglass reinforced plastic (PA),<br />
black, complies with UL 94 V-0 requirements, 1 piece<br />
60225-053<br />
Protective grille clip-in fibreglass reinforced plastic (PA),<br />
black, complies with UL 94 V-0 requirements, 1 piece<br />
60225-052<br />
Bolt-on protective grille<br />
KTA43091<br />
Technical data AC fans<br />
Dimensions 25 × 119 × 119 25 × 119 × 119 38 × 119 × 119<br />
H×W×D<br />
in mm<br />
Frequency in Hz 50 60 50 60 50 60<br />
Air capacity in 84 90 108 120 162 192<br />
m 3 /h<br />
Noise level per 29 30 34 38 37 41<br />
fan in dB (A)<br />
Max. stat. 23 21 41 41 73 88<br />
pressure in PA<br />
Max. ambient 70 70 70 70 70 70<br />
temperature in<br />
°C<br />
Power<br />
8 7 14 11 15 14<br />
consumption in<br />
W<br />
KTA45223<br />
For further information www.schroff.biz/oneClick<br />
z/oneClick<br />
oneClick code = Order no.<br />
For further information ... www.schroff.biz<br />
UK 08/2003<br />
2.29
<strong>Climate</strong> <strong>control</strong> – Accessories<br />
DC fans<br />
Accessories<br />
Delivery comprises (Individual part)<br />
Item Qty Description<br />
1 1 Fans height 38 mm (width 119 mm, depth 119 mm)<br />
1a 1 Fans height 25 mm (width 119 mm, depth 119 mm)<br />
with cable for connection, length 55 mm, 2 fast-on<br />
connectors 2.8 x 0.8 mm<br />
Connecting lead<br />
KTA44844<br />
Order Information<br />
Height<br />
Air capacity<br />
50 Hz, DC<br />
Power consumption<br />
50 Hz<br />
Input<br />
voltage<br />
Order no.<br />
mm m³/h W V<br />
25 153 7 24 20713-172<br />
38 184 8 24 20713-240<br />
38 184 8 12 20713-241<br />
38 184 8 48 20713-242<br />
Connecting lead PVC (2 x 0.75 mm²), 1 m long with 2<br />
fast-on connectors 2.8 x 0.8 mm, 1 piece<br />
21101-246<br />
Protective grille bolt-on fibreglass reinforced plastic<br />
(PA), black, complies with UL 94 V-0 requirements, 1 piece<br />
60225-053<br />
Protective grille clip-in fibreglass reinforced plastic (PA),<br />
black, complies with UL 94 V-0 requirements, 1 piece<br />
60225-052<br />
Bolt-on protective grille<br />
KTA43091<br />
KTA45223<br />
Technical data DC fans<br />
Voltage in V DC 24 24 12 48<br />
Dimensions<br />
H × W × D<br />
in mm<br />
Air capacity in<br />
m 3 /h<br />
Noise level per<br />
fan in dB (A)<br />
Max. stat.<br />
pressure in PA<br />
Max. ambient<br />
temperature in<br />
°C<br />
Power<br />
consumption in<br />
W<br />
25 × 119 ×<br />
119<br />
38 × 119 ×<br />
119<br />
38 × 119 ×<br />
119<br />
195 184 184 184<br />
41.5 42 42 42<br />
50.5 68 68 68<br />
70 70 70 70<br />
7 8 8 8<br />
38 × 119 ×<br />
119<br />
Note<br />
Connector lead does not fits with fan 25 mm hight<br />
For further information www.schroff.biz/oneClick<br />
oneClick code = Order no.<br />
2.30<br />
UK 08/2003<br />
For further information ... www.schroff.biz
<strong>Climate</strong> <strong>control</strong> – Accessories<br />
Speed <strong>control</strong> for fans<br />
Accessories<br />
Speed <strong>control</strong> for 19" fan, 19" blower unit or top cover fan tray<br />
The airflow volume is set depending on:<br />
the ambient temperature<br />
the current energy loss<br />
the actual air resistances<br />
the desired cabinet inner temperature<br />
This has the following advantages:<br />
Functional reliability due to constant cabinet inner temperature<br />
Low noise<br />
01195001<br />
Delivery comprises (assembled)<br />
Item Qty Description<br />
1 1 Speed <strong>control</strong>, see technical data<br />
2 1 Temperature sensor NTC resistor, cable length 1.5 m<br />
3 1 Fan cable, cable length 1.5 m with fast-on connectors<br />
6.3 × 0.8 mm<br />
4 1 Mains cable, cable length 3 m, end isolation stripped<br />
with end sleeves<br />
5 1 Mounting plate for assembly on cabinet upright<br />
6 1 Spring for mounting on the support rail<br />
Order Information<br />
KTA43494<br />
115 V AC 230 V AC<br />
Type Application Order no. Order no.<br />
Single-phase motor 19" fan, blower unit 10713-522 10713-523<br />
Capacitor motor – 10713-524 10713-525<br />
Technical data<br />
KTA43495<br />
Voltage range 110 ... 120 V 220 ... 240 V<br />
Frequency in Hz 50 ... 60 50 ... 60<br />
Input voltage 90 ... 132 V 187 ... 264 V<br />
max. connection power in W 220<br />
possible mains/line frequency 48...62 Hz<br />
Cabinet temperature in °C Adjustment range: +25...+50<br />
Fan speed in % 30...100<br />
Power lead<br />
3 m, end isolation stripped with end<br />
sleeves<br />
Sensor<br />
External NTC resistor<br />
Sensor connection<br />
Plug-in contact and cable 1.5 m<br />
If sensor fails<br />
Maximum speed<br />
Dimensions:<br />
120 × 65 × 40<br />
Width x Height x Depth in mm<br />
Fan connection<br />
Cable 1.5 m with Faston connectors<br />
6.3 x 0.8 mm<br />
For further information www.schroff.biz/oneClick<br />
oneClick code = Order no.<br />
For further information ... www.schroff.biz<br />
UK 08/2003<br />
2.31
<strong>Climate</strong> <strong>control</strong> – Accessories<br />
Thermostat with integral temperature sensor<br />
Accessories<br />
For switching heater units or fans<br />
Adjustment range 5 ... 60 °C<br />
Order Information<br />
100 ... 130 V AC 200 ... 250 V AC<br />
Description Order no. Order no.<br />
Thermostat with integral temperature<br />
sensor<br />
20715-007 20715-002<br />
Technical data<br />
01102008<br />
Dimensions Height x Width x Depth 75 × 75 × 25<br />
in mm<br />
Adjustment range 5 ... 60 °C<br />
Switching differential<br />
0.5 K<br />
Contact load<br />
(ohmic Load / inductive load)<br />
Contacts<br />
Assembly<br />
Heat (terminal 1–2) 10 A / 4 A<br />
cool (terminal 1–3) 5 A / 2 A<br />
Changeover contact, 1-pin<br />
Bolt-on, alternatively with clip-on<br />
attachment for support rail<br />
For further information www.schroff.biz/oneClick<br />
oneClick code = Order no.<br />
Thermostat with external temperature sensor<br />
Accessories<br />
External sensor can be positioned near the critical assembly<br />
Adjustment range 20 ... 60 °C<br />
Order Information<br />
Description<br />
Order no.<br />
Voltage range: 90 ... 260 V AC 20715-003<br />
Technical data<br />
01102007<br />
Dimensions Height x Width x Depth 93 × 68 × 44<br />
in mm<br />
Adjustment range 20 ... 60 °C<br />
Switching differential<br />
10 K<br />
Contact load<br />
24 A/10 A<br />
(ohmic load / inductive load)<br />
Contacts<br />
Changeover contact, 1-pin<br />
Assembly<br />
bolt-on<br />
For further information www.schroff.biz/oneClick<br />
oneClick code = Order no.<br />
2.32<br />
UK 08/2003<br />
For further information ... www.schroff.biz
<strong>Climate</strong> <strong>control</strong> – Accessories<br />
Thermostat with digital display<br />
Accessories<br />
For rack-mounting and panel-mounting<br />
Display changeable from °C to °F<br />
Programmable (secured against unauthorised operation)<br />
Switching differential of 0 ... 10 K freely selectable<br />
3-digit, red display<br />
Order Information<br />
Description<br />
Order no.<br />
Thermostat with digital display 60715-132<br />
Front panel RAL 7035 light grey with cut-out for the<br />
thermostat<br />
30118-315<br />
Front panel anodised with cut-out for the thermostat 30118-267<br />
Front panel 1 U<br />
01197001<br />
SZA45550<br />
Technical data<br />
Operating voltage 115 / 230 V AC (90 ... 260 V AC )<br />
Power consumption in W approx. 3.5<br />
Dimensions Height x Width x Depth 35 × 76 × 59<br />
mm<br />
Assembly cut-out 28.8 × 70.5<br />
Adjustment range in °C -50...+100<br />
Switching differential<br />
0 ... 10 K selectable<br />
Data retention in the event of power Non-volatile memory<br />
failure<br />
Contact load<br />
8 A/3 A<br />
(ohmic Load / inductive load)<br />
Input/sensor<br />
PTC sensor,<br />
-55...+120 °C, cable length 3 m<br />
Contacts<br />
Relay, changeover contact, 1-pin<br />
Type of protection, from(front) IP 54<br />
Connection Screw clamps 2.5 mm 2<br />
Assembly<br />
Mounting with clamping bracket<br />
Assembly<br />
Bolt-on<br />
For further information www.schroff.biz/oneClick<br />
oneClick code = Order no.<br />
For further information ... www.schroff.biz<br />
UK 08/2003<br />
2.33
<strong>Climate</strong> <strong>control</strong> – Accessories<br />
Hygrostat<br />
Accessories<br />
The hygrostat is used to <strong>control</strong> heating systems to raise the<br />
dewpoint from critical relative air humidity of 65%. -This<br />
prevents condensation and corrosion on components.<br />
Order Information<br />
Description<br />
Order no.<br />
Hygrostat 60715-041<br />
Support rail incl. assembly parts 21101-421<br />
01102006<br />
Technical data<br />
Dimensions Height x Width x Depth 75 × 75 × 25<br />
in mm<br />
Adjustment range of relative air 35 ... 100<br />
humidity in %<br />
Switching differential in % approx. 4<br />
Contact load AC: 24 - 230 V 5 A/0.2 A<br />
(ohmic load / inductive load)<br />
Contact load DC:<br />
max. 60 Watt<br />
Contacts<br />
Changeover contact, 1-pin<br />
Assembly<br />
Bolt-on, alternatively with clip-on<br />
attachment for support rail<br />
For further information www.schroff.biz/oneClick<br />
oneClick code = Order no.<br />
Inlet IEC<br />
Accessories<br />
For the connection of fans<br />
Bolted housing made of heat-resistant plastic (UL 94 V-0).<br />
10 A / 250 V AC , class of protection I<br />
Order Information<br />
Description<br />
Order no.<br />
Inlet IEC 60715-046<br />
KTA45246<br />
For further information www.schroff.biz/oneClick<br />
oneClick code = Order no.<br />
2.34<br />
UK 08/2003<br />
For further information ... www.schroff.biz
<strong>Climate</strong> <strong>control</strong> – Accessories<br />
For further information ... www.schroff.biz<br />
UK 08/2003<br />
2.35