20.01.2015 Views

Climate control

Climate control

Climate control

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Overview ................. 0<br />

<strong>Climate</strong> <strong>control</strong><br />

Cabinets.................. 1<br />

<strong>Climate</strong> Control....... 2<br />

Cases ...................... 3<br />

Subracks/<br />

19" chassis............. 4<br />

High air capacity<br />

Can be adapted on subracks<br />

Modules .................. 5<br />

Systems .................. 6<br />

Power supply<br />

units........................ 7<br />

Backplanes ............. 8<br />

For indoor and outdoor applications<br />

Microcomputer <strong>control</strong>led<br />

Accessories ............ 9<br />

Appendix............... 10<br />

2.0 UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> <strong>control</strong><br />

Overview<br />

.............. 2.0<br />

Service ................. 2.2<br />

Degree of protection IP 54<br />

Easy to mount – clip in<br />

19"-fan units........ 2.4<br />

Air filtered fans .. 2.16<br />

Heat exchanger.. 2.24<br />

Accessories<br />

Heaters . . . . . . . . . . 2.26<br />

Fans . . . . . . . . . . . . 2.29<br />

Speed <strong>control</strong> . . . . . 2.31<br />

Thermostat . . . . . . . 2.32<br />

Hygrostat . . . . . . . . 2.34<br />

With or without fan<br />

Quick and easy to mount<br />

Cooling concept with Flowtherm simulation<br />

Calculation aid on the internet<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.1


Overview ................. 0<br />

<strong>Climate</strong> Control – Service – Overview<br />

Cabinets.................. 1<br />

‘FLOTHERM’ Simulation<br />

Project support through<br />

simulation software<br />

<strong>Climate</strong> Control....... 2<br />

Cases ...................... 3<br />

Subracks/<br />

19" chassis............. 4<br />

With the simulation software ’FLOTHERM’ heat field and problem<br />

areas can be recognised during the concept phase. Cooling<br />

concepts for assemblies up to total cases and cabinet systems can<br />

be analysed. Our ’FLOTHERM’ specialists will assist you in<br />

simulating your design.<br />

Your advantage:<br />

You analyse and remove problems in advance during<br />

the prototype phase<br />

You therefore increase the performance and the reliability<br />

of your system<br />

You shorten your development times<br />

Modules .................. 5<br />

Systems .................. 6<br />

Power supply<br />

units........................ 7<br />

Backplanes ............. 8<br />

01103050<br />

RESULT:<br />

Cost savings<br />

Your input:<br />

Capacity loss of the various components<br />

(units, boards, ...)<br />

Environmental and working conditions (outside temperature,<br />

maximum inside temperature)<br />

System assembly (geometry)<br />

RESULT:<br />

Joint establishment of the thermal analysis<br />

Optimum arrangement of components<br />

Accessories ............ 9<br />

01103051<br />

Appendix............... 10<br />

Further important information can be found on the internet<br />

under www.schroff.biz<br />

2.2 UK 04/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> Control – Service – Overview<br />

Overview .............. 2.2<br />

Cooling Concepts with Standard Products<br />

<strong>Climate</strong> <strong>control</strong> of Cabinets<br />

and Cases<br />

Specific heat removal<br />

from systems<br />

19" fan units<br />

19" blower units<br />

01102050 0092050 01102051<br />

Air filtered fans<br />

Heat exchanger/<br />

Air conditioners<br />

V ° (m 3 /h)<br />

V ° (m 3 /h)<br />

Configuration in the Internet (www.schroff.biz)<br />

On our home page on the internet you will find assistance when<br />

selecting standard components.<br />

Describe your basic requirements by stating the following:<br />

installed heat loss<br />

requested temperature inside the cabinet<br />

Configuration<br />

via the Internet<br />

P V (W)<br />

A41771<br />

maximum outside temperature at the installation site<br />

type of installation<br />

and we will direct you to possible alternatives from our standard<br />

program.<br />

For further information ... www.schroff.biz<br />

UK 04/2003<br />

2.3


Overview ................. 0<br />

<strong>Climate</strong> <strong>control</strong> – 19"-fan units<br />

Cabinets.................. 1<br />

<strong>Climate</strong> Control....... 2<br />

Cases ...................... 3<br />

Subracks/<br />

19" chassis............. 4<br />

Modules .................. 5<br />

01102012<br />

Systems .................. 6<br />

Power supply<br />

units........................ 7<br />

Mechanical safety device<br />

for power lead<br />

01197002<br />

Configure the 19" fan units<br />

individually<br />

01194004<br />

Backplanes ............. 8<br />

Accessories ............ 9<br />

Appendix............... 10<br />

Standards<br />

19" mounting to IEC 60297-3<br />

Mechanical protection according to EN 292<br />

Touch protection according to EN 294<br />

Electrical safety according to EN 60335 part 1<br />

Modifications<br />

Other air capacities<br />

DC voltages<br />

Filter mats<br />

Other dimensions<br />

Further important information can be found on the internet<br />

under www.schroff.biz<br />

Configurator 19“fan units<br />

2.4 UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> <strong>control</strong> – 19"-fan units<br />

19"-fan units........ 2.4<br />

19" fan units<br />

Removal of heat by 19" fan units<br />

High running performance<br />

Mechanical touch protection<br />

Adaption to subrack possible<br />

With or without switch<br />

19" Blowers<br />

For Cooling of single components and assemblies<br />

Height 1 U<br />

19" fan units<br />

1 U with/without front<br />

switch ........................2.8<br />

1 U, speed-<strong>control</strong>led<br />

and monitored .........2.10<br />

Individual configurations can be assembled with the help of the<br />

configurator on our homepage (www.schroff.biz)<br />

01102052<br />

19"-Pressure fans<br />

For Cooling of single components and assemblies<br />

Height 2 U and 3 U<br />

19" blower unit<br />

2 U with<br />

tangential fan ..........2.11<br />

2 U (160, 220 mm<br />

deep)........................2.12<br />

Supplementary fan<br />

for 2 U fan unit.........2.13<br />

3 U............................2.14<br />

Ventilation panel<br />

for 3 U ......................2.15<br />

01102053<br />

V ° (m 3 /h)<br />

Selection Guide<br />

Selection guide<br />

Versions .....................2.6<br />

Dimensions ................2.7<br />

P V (W)<br />

A41771<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.5


<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />

19" fan versions<br />

Fan for assembly in the 19" mounting space<br />

High air throughput<br />

Long service life<br />

Tested and approved<br />

The 19" fans are available in two versions:<br />

19" blower unit<br />

01192002<br />

19" fan unit<br />

19" blower unit<br />

19" subracks with 160 or 220 mm standard board format are given<br />

optimum cooling by means of blower units, even if several<br />

subracks (each with blower units) are mounted one above the<br />

other.<br />

01192006<br />

19" fan unit<br />

These fans extract the heat from plug-in units and are available<br />

with or without illuminated switches. A low-noise version works<br />

with temperature-dependent speed <strong>control</strong> and its function is<br />

monitored. 19" fan units can also be configured individually<br />

(www.schroff.biz).<br />

Service life<br />

The service life of the fans depends on the way they are used. At<br />

an ambient temperature of 40 °C, it is approx. 40000 – 60000<br />

hours.<br />

01102016<br />

Standards<br />

19" mounting complying with IEC 60 297-3-101. Plastics are selfextinguishing<br />

to comply with UL 94 V 1. PPO and fibreglass<br />

reinforced plastics are self-extinguishing to comply with<br />

UL 94 V-0. Mechanical protection in accordance with EN 292.<br />

Contact protection in accordance with EN 294. Electrical safety in<br />

accordance with EN 60335, Part 1.<br />

19" fan racks<br />

2.6<br />

UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />

19" fan dimensions<br />

V (m 3 /h)<br />

19" blower unit<br />

19" fan unit<br />

For local heat dissipation, the airflow volume required to extract<br />

the (energy loss) heat is calculated.<br />

P v (W)<br />

A41771<br />

Note<br />

The cabinet ventilation is not taken into account here.<br />

The required airflow volume is calculated as follows:<br />

V= (f x P v ) / T<br />

The air constant f = 3.3 mm 3 K/Wh.<br />

T is the difference between the ambient temperature and the<br />

internal temperature.<br />

Example<br />

- Pv = 600 W<br />

- internal temperature = 25 °C<br />

- ambient temperature = 30 °C<br />

1. T = T i – T a = 30 °C – 25 °C = 5 K<br />

2. From P v = 600 W for curve for T =5 K<br />

3. From the point of intersection down to the airflow volume<br />

V = 400 m 3 /h<br />

19" fan racks<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.7


geprüfte<br />

Sicherheit<br />

<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />

19" fan unit 1 U<br />

19" fan racks<br />

Mechanical strain relief for mains cable<br />

Adaptation to subracks possible<br />

Contact protection in accordance with EN 294.<br />

Delivery comprises (assembled and wired)<br />

01194002<br />

Item Qty Description<br />

1 1 Front panel 1 U, aluminium 3 mm, anodised<br />

2 1 Case with grille, 1 mm steel, AIZn<br />

3 3 / 6 Fan, see ordering information<br />

4 1 IEC 320 input socket<br />

5 1 Safety device, mechanical strain relief for mains input<br />

cable<br />

6 1 Connection lead for 24 V DC supplied (please order<br />

separately for AC fan)<br />

Order Information<br />

230 V AC 115 V AC 24 V DC<br />

Order No. Order No. Order No.<br />

10713-100 10713-102 10713-103<br />

KTA44857<br />

10713-104 10713-106 10713-107<br />

KTA44306<br />

KTA44858<br />

Adapter bracket Subrack, europac to fan tray, incl.<br />

assembly parts<br />

21101-104<br />

Adapter bracket Subrack, europacPRO to fan tray, incl.<br />

assembly parts<br />

21101-954<br />

Equipment cable for AC fan, UTE, 2.5 m 60103-131<br />

Equipment cable for AC fan, British standard, 2.5 m 60103-137<br />

Equipment cable for AC fan, IEC, 2.5 m 60103-141<br />

Technical data of the individual fans<br />

Voltage 230 V AC 115 V AC 24 V DC<br />

Frequency in Hz 50 60 50 60 -<br />

Air capacity (free blowing) in m 3 /h 162 192 162 192 184<br />

Noise level per fan in dB (A) 37 41 37 41 42<br />

Max. stat. pressure in PA 73 88 73 88 68<br />

Max. ambient temperature in °C 70 70 70 70 70<br />

Power consumption in W 15 14 15 14 8<br />

Replacement fans, see chapter '<strong>Climate</strong> <strong>control</strong> - accessories'<br />

2.8<br />

UK 08/2003<br />

For further information ... www.schroff.biz


geprüfte<br />

Sicherheit<br />

<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />

19" fan unit 1 U<br />

with front switch<br />

19" fan racks<br />

Front mains switch plus additional mains output socket<br />

Mechanical strain relief for mains input and mains output cable<br />

Adaptation to subracks possible<br />

Contact protection in accordance with EN 294.<br />

Delivery comprises (assembled and wired)<br />

01194003<br />

Item Qty Description<br />

1 1 Front panel 1 U, aluminium 3 mm, anodised<br />

2 1 Case with grille, 1 mm steel, AIZn<br />

3 3 / 6 Fan, see ordering information<br />

4 1 IEC 320 input socket<br />

5 1 IEC 320 output connector<br />

6 2 Safety device, mechanical strain relief for mains cable<br />

7 1 Illuminated switch, green, plain for 24 V DC<br />

8 1 Connection lead for 24 V DC supplied (please order<br />

separately for AC fan)<br />

Order Information<br />

230 V AC 115 V AC 24 V DC<br />

Order no. Order no. Order no.<br />

01197002<br />

10713-108 10713-110 10713-111<br />

KTA44857<br />

10713-112 10713-114 10713-115<br />

KTA44858<br />

Adapter bracket Subrack, europac to fan tray, incl.<br />

assembly parts<br />

21101-104<br />

Adapter bracket Subrack, europacPRO to fan tray, incl.<br />

assembly parts<br />

21101-954<br />

Equipment cable for AC fan, UTE, 2.5 m 60103-131<br />

Equipment cable for AC fan, British standard, 2.5 m 60103-137<br />

Equipment cable for AC fan, IEC, 2.5 m 60103-141<br />

Equipment cable for power output, 2.5 m 60197-053<br />

KTA45963<br />

Technical data of the individual fans<br />

Voltage 230 V AC 115 V AC 24 V DC<br />

Frequency in Hz 50 60 50 60 -<br />

Air capacity (free blowing) in m 3 /h 162 192 162 192 184<br />

Noise level per fan in dB (A) 37 41 37 41 42<br />

Max. stat. pressure in PA 73 88 73 88 68<br />

Max. ambient temperature in °C 70 70 70 70 70<br />

Power consumption in W 15 14 15 14 8<br />

Replacement fans, see chapter '<strong>Climate</strong> <strong>control</strong> - accessories'<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.9


<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />

19" fan 1 U,<br />

speed-<strong>control</strong>led and monitored<br />

19" fan racks<br />

Noise optimisation through temperature-dependent speed<br />

<strong>control</strong><br />

Temperature range selectable 20 ... 40 °C and 30 ... 50 °C<br />

External sensor (with sensor break max. speed.)<br />

Function monitoring with LEDs and via potential-free contacts<br />

Contact protection in accordance with EN 292.<br />

01198001<br />

Delivery comprises (assembled and wired)<br />

Item Qty Description<br />

1 1 Front panel 1 U, aluminium 3 mm, anodised<br />

2 1 Case with grille, 1 mm steel, AIZn<br />

3 3 DC-fan<br />

4 1 Connection lead, cable length 2.5 m, open end<br />

5 1 Temperature sensor, NTC resistor, cable length 1.5 m<br />

Order Information<br />

Description<br />

Order no.<br />

19" fan 1 U, speed-<strong>control</strong>led and monitored 10713-099<br />

Filter mat for 19" fan unit, 3 pieces, please order<br />

separately<br />

60713-169<br />

Control range<br />

KTA43398<br />

Technical data of the individual fans<br />

Voltage<br />

24 V DC<br />

Air capacity in m 3 /h 80...170<br />

Noise level per fan in dB (A) max. 45<br />

Max. stat. pressure in PA max. 70<br />

Max. ambient temperature in °C 65<br />

Power consumption in W 5.3<br />

Monitoring signal<br />

KTA43399<br />

Technical data Control / monitoring<br />

Control range Change-over switch from 20...40 °C to 30...50 °C<br />

Sensor<br />

External, NTC resistor, cable length 1.5 m<br />

Sensor connection Rear plug-in contact, with sensor break max.<br />

speed<br />

Signal for<br />

Speed 60, 20% nominal speed;<br />

switch-on delay 60, 4 s, signal delay 60, 1 s<br />

(see 'Monitoring signal')<br />

Signalling<br />

Display via LEDs<br />

Potential-free contact (changeover contact),<br />

power 20 W, voltage max. 100 V<br />

Open collector available on request<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

n = speed, S = signal, n A = speed threshold value "alarm"<br />

KTA43400<br />

2.10<br />

UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />

Blower unit 2 U<br />

with tangential fan<br />

19" fan racks<br />

High air capacity<br />

Integrated filter mat<br />

2 versions:<br />

- LE1: 19" full width<br />

- LE2: 19" reduced width, for easy assembly<br />

01192009<br />

Delivery comprises (assembled)<br />

Item Qty Description<br />

1 1 Front grille 2 U, PPO, UL 94 V-0<br />

2 1 Filter mat, fibre, filter class EU 2<br />

3 1 Case with grille, PA 6.6, UL 94 V-0<br />

4 1 Fans<br />

5 1 Terminal connection strip<br />

Order Information<br />

230 V AC 115 V AC<br />

Description Order no. Order no.<br />

LE 1 60713-001 60713-003<br />

LE 2 60713-002 60713-004<br />

Spare filter mat 10 pieces 20705-008<br />

Technical data<br />

A3532<br />

Voltage in V 230 V AC 115 V AC<br />

Frequency in Hz 50 60 50 60<br />

Air capacity in m 3 /h 300 310 300 310<br />

Noise level per fan in dB (A) 53 54 53 54<br />

Max. stat. pressure in PA 65 70 65 70<br />

Max. ambient temperature in °C 65 65 65 65<br />

Power consumption in W 40 50 40 50<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

01103056<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.11


<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />

19" blower unit 2U<br />

(160, 220 mm deep)<br />

19" fan racks<br />

Integrated air baffle prevents heat accumulation on plug-in units<br />

underneath<br />

Optional rear supplementary fan 2 U<br />

Adaptation to subracks possible<br />

01194005<br />

Delivery comprises (assembled and wired)<br />

Item Qty Description<br />

1 1 Front grille 2 U, PPO, UL 94 V-0<br />

2 1 Filter mat, fibre, filter class EU 2<br />

3 1 Case, 1 mm steel, AIZn<br />

4 3 Fan, see ordering information<br />

5 1 IEC 320 input socket<br />

6 1 Safety device, mechanical strain relief for mains input<br />

cable<br />

7 1 Equipment cable for 24 V DC supplied (please order<br />

separately for AC fan)<br />

01103054<br />

A3527V<br />

Order Information<br />

Voltage<br />

airflow capacity at 50/60 Hz<br />

230 V AC 230 V AC 115 V AC 115 V AC 24 V DC<br />

108/120 m 3 /h 162/192 m 3 /h 108/120 m 3 /h 162/192 m 3 /h 184 m 3 /h<br />

Type Order No. Order No. Order No. Order No. Order No.<br />

for board depth 160 mm 10713-518 10713-534 10713-520 10713-536 10713-537<br />

for board depth 220 mm – 10713-526 – 10713-528 10713-529<br />

Equipment cable for AC fan, UTE, 2.5 m 60103-131<br />

Equipment cable for AC fan, British standard, 2.5 m 6010<br />

Equipment cable for AC fan, IEC, 2.5 m 60103-141<br />

Adapter bracket Subrack, europac to fan tray, incl. assembly parts 21101-104<br />

Adapter bracket Subrack, europacPRO to fan tray, incl. assembly parts 21101-954<br />

Spare filter mat 3 pieces 60713-501<br />

Technical data<br />

of the individual fans<br />

Voltage 230 V AC 115 V AC 24 V DC<br />

Frequency in Hz 50 60 50 60 50 60 50 60 -<br />

Air capacity in m 3 /h 108 120 162 192 108 120 162 192 184<br />

Noise level per fan in dB (A) 34 38 37 41 34 38 37 41 42<br />

Max. stat. pressure in PA 41 41 73 88 41 41 73 88 88<br />

Max. ambient temperature in °C 70 70 70 70 70 70 70 70 70<br />

Power consumption in W 14 11 15 14 14 11 15 14 8<br />

2.12<br />

UK 08/2003<br />

For further information ... www.schroff.biz


geprüfte<br />

Sicherheit<br />

<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />

Supplementary fan for 2 U<br />

fan unit<br />

19" fan racks<br />

2 U mounting space:<br />

the use of the supplementary fan means that plug-in units<br />

beneath the 19" blower unit can be cooled<br />

No additional power supply necessary: connection via 19"<br />

blower unit, 2 U<br />

Delivery comprises<br />

01194006<br />

Item Qty Description<br />

1 1 Case with grille, 1 mm steel, AIZn<br />

2 4 Fans<br />

3 1 Connector (electrical connection via connector on the<br />

19" blower unit)<br />

4 1 Safety device (mechanical strain relief for mains input<br />

cable)<br />

Order Information<br />

230 V AC 115 V AC<br />

Description Order no. Order no.<br />

Supplementary fan for 2 U fan unit 10713-530 10713-532<br />

Technical data of the individual fans<br />

KTA44447<br />

Voltage 230 V AC 115 V AC<br />

Frequency in Hz 50 60 50 60<br />

Air capacity in m 3 /h 45 54 45 54<br />

Noise level per fan in dB (A) 33 38 33 38<br />

Max. stat. pressure in PA 44 63 44 63<br />

Max. ambient temperature<br />

70 70 70 70<br />

in °C<br />

Power consumption in W 10 8 10 8<br />

Replacement fans, see chapter '<strong>Climate</strong> <strong>control</strong> - accessories'<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

01103055<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.13


<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />

19" blower unit 3 U<br />

19" fan racks<br />

This blower unit can be re-equipped for different cooling concepts<br />

using cover plates<br />

Specific air supply to subracks<br />

Air supply in the rear cabinet area<br />

Connection options for hoses for specific air supply<br />

01102017<br />

Delivery comprises (assembled and wired)<br />

Item Qty Description<br />

1 1 perforated hinged front panel, 2.5 mm aluminium<br />

2 1 Filter mat, fibre, filter class G 2 complying with EN 779<br />

3 1 Case, 1 mm steel, AIZn<br />

4 1 Radial fan<br />

5 1 IEC 320 inlet socket<br />

6 1 Safety device, mechanical strain relief for mains input<br />

cable<br />

Order Information<br />

230 V AC 115 V AC<br />

Description Order no. Order no.<br />

19" blower unit 3 U<br />

Equipment cable, UTE, 2.5 m<br />

Equipment cable, British standard, 2.5 m<br />

Equipment cable, IEC, 2.5 m<br />

10713-546 10713-547<br />

60103-131<br />

60103-137<br />

60103-141<br />

Adapter bracket Subrack, europac to fan tray, incl.<br />

assembly parts<br />

21101-958<br />

Adapter bracket Subrack, europacPRO to fan tray, incl.<br />

assembly parts<br />

Spare filter mat 3 pieces<br />

21101-954<br />

60713-868<br />

Technical data<br />

01103052<br />

Voltage 230 V AC 115 V AC<br />

Frequency in Hz 50 60 50 60<br />

Air capacity in m 3 /h 570 620 570 615<br />

Noise level per fan in dB (A) 62 64 64 67<br />

Max. stat. pressure in PA 320 405 320 420<br />

Max. ambient temperature in °C 50 55 60 60<br />

Power consumption in W 58 75 57 81<br />

Fan trays for other cooling concepts, see next page 2.15<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

2.14<br />

UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />

Ventilation panel for<br />

19" blower unit 3 U<br />

19" fan racks<br />

For 19" blower unit 3 U<br />

Order Information<br />

Item Description Qty Order no.<br />

7 Front fan panel, 1 mm steel, AlZn 1 20713-504<br />

8<br />

Ventilation to rear side: top panel<br />

without perforation ,1 mm steel, AlZn<br />

1 20713-505<br />

9<br />

Ventilation panel with ducting<br />

connection at the top, 1 mm steel, AlZn 1 20713-503<br />

Ventilation panel with ducting<br />

10 connection at the rear, 1 mm steel,<br />

AlZn<br />

1 20713-502<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

01102053<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.15


Overview ................. 0<br />

<strong>Climate</strong> Control – Air filtered fans<br />

Cabinets.................. 1<br />

<strong>Climate</strong> Control....... 2<br />

Cases ...................... 3<br />

Subracks/<br />

19" chassis............. 4<br />

Modules .................. 5<br />

Systems .................. 6<br />

01102005<br />

Power supply<br />

units........................ 7<br />

Backplanes ............. 8<br />

Accessories ............ 9<br />

Improved EMC protection<br />

with EMC filter fans<br />

01102010 01102009<br />

01102011<br />

Easy changeover of operation for<br />

incoming to outgoing air<br />

Assembly simply<br />

by clipping into place<br />

Appendix............... 10<br />

Standards<br />

Protection to IP 54 according to IEC 60529<br />

Earthing according to IEC 60335-2-16<br />

Mechanical protection according to EN 292<br />

Touch protection according to EN 294<br />

Modificatons<br />

Special colour RAL 7032<br />

Other air capacities<br />

Other voltages<br />

Further important Information can be found on the internet<br />

under www.schroff.biz<br />

2.16 UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> Control – Air filtered fans<br />

Overview ............ 2.16<br />

Removal of heat with the help of filtered fans<br />

Protection to IP 54<br />

Assembly simply by clipping into place<br />

Easy changeover of operation for incoming to outgoing air<br />

Flat front grille does not protrude more than 6 mm or 7 mm<br />

Air filtered fans<br />

Air filtered fans<br />

FL 100 ......................2.18<br />

FL 200 ......................2.19<br />

FL 250 ......................2.20<br />

FL 300 ......................2.21<br />

FL 500 ......................2.22<br />

FL 600 ......................2.23<br />

01102050<br />

Selection Guide<br />

KTA45245<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.17


<strong>Climate</strong> <strong>control</strong> – Air filtered fan<br />

FL 100<br />

Air filtered fan FL 100<br />

Air filtered fan<br />

Simple conversion from pressure to suction mode<br />

Type of protection IP54<br />

Delivery comprises (completely assembled)<br />

Item Qty Description<br />

1 1 Front grille and case, plastic PC, RAL 7035,<br />

self-extinguishing, similar to UL 94 V-0<br />

2 1 Filter mat, 150 g/m 3 quality class EU 2<br />

3 1 Fan<br />

4 1 Connection, 2 wires 310 mm long<br />

5 1 Capacitor<br />

Order Information<br />

FLA 100<br />

KTA45979<br />

230 V AC 115 V AC 24 V DC<br />

Description Order no. Order no. Order no.<br />

Air filtered fan FL 100 60715-059 60715-061 60715-063<br />

Outlet/Inlet filterFLA 100<br />

(Delivery comprises items1 + 2), 1 piece<br />

60715-087<br />

Replacement filter for FL 100 / FLA 100,<br />

(Delivery comprises item 2), 3 pieces<br />

60715-094<br />

Technical data of the fan<br />

Voltage in V 230 115 24<br />

Frequency in Hz 50 / 60 50 / 60 DC<br />

Air capacity with filter<br />

24 24 24<br />

(free blowing ) in m 3 /h<br />

Combination FL + FLA in m 3 /h 15 15 15<br />

Noise level per fan in dB (A) 39 39 39<br />

Max. stat. pressure in PA 29 29 29<br />

Max. ambient temperature in °C -10...+60 -10...+60 -20...+60<br />

Power consumption in W 11 11 2.4<br />

Filter efficiency in % 67 67 67<br />

KTA46383<br />

For further information www.schroff.biz/oneClick<br />

Click<br />

oneClick code = Order no.<br />

2.18<br />

UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> <strong>control</strong> – Air filtered fan<br />

FL 200<br />

Air filtered fan FL 200<br />

Air filtered fan<br />

Simple conversion from pressure to suction mode<br />

EMC design<br />

Type of protection IP54<br />

Delivery comprises (completely assembled)<br />

Item Qty Description<br />

1 1 Front grille and case, Plastic ABS, RAL 7035,<br />

self-extinguishing, similar to UL 94 V-0<br />

2 1 Filter mat, 350 g/m 3 quality class EU 2<br />

3 1 Fan<br />

4 1 Connection AC (2-pin terminal block)<br />

connection DC (2 wires, 310 mm long)<br />

5 1 Capacitor<br />

FLA 200<br />

KTA45978<br />

Order Information<br />

230 V AC 115 V AC 24 V DC<br />

Description Order no. Order no. Order no.<br />

Standard air filtered fan FL 200 60715-065 60715-067 60715-069<br />

Air filtered fan FL 200 EMC<br />

60715-102 60715-104 60715-106<br />

Outlet/Inlet filter FLA 200 Standard<br />

(Delivery comprises items 1 + 2), 1 piece<br />

60715-089<br />

Outlet/Inlet filter FLA 200 EMC<br />

(Delivery comprises items 1 + 2), 1 piece<br />

60715-124<br />

Replacement filter for FL 200 / FLA 200,<br />

(Delivery comprises item 2), 3 pieces<br />

60715-095<br />

KTA46384<br />

Technical data of the fan<br />

Voltage in V 230 115 24<br />

Frequency in Hz 50 / 60 50 / 60 DC<br />

Air capacity with filter<br />

56 56 56<br />

(free blowing ) in m 3 /h<br />

Combination FL + FLA in m 3 /h 42 42 42<br />

Noise level per fan in dB (A) 49 49 49<br />

Max. stat. pressure in PA 69 69 69<br />

Max. ambient temperature in °C -10...+50 -10...+50 -20...+50<br />

Power consumption in W 18 20 4.5<br />

Filter efficiency in % 83 83 83<br />

Note<br />

EMC version, assembly cut-out 2 mm larger (height, width)<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.19


<strong>Climate</strong> <strong>control</strong> – Air filtered fan<br />

FL 250<br />

Air filtered fan FL 250<br />

Air filtered fan<br />

Simple conversion from pressure to suction mode<br />

EMC design<br />

Type of protection IP54<br />

Delivery comprises (completely assembled)<br />

Item Qty Description<br />

1 1 Front grille and case, Plastic ABS, RAL 7035,<br />

self-extinguishing, similar to UL 94 V-0<br />

2 1 Filter mat, 350 g/m 3 quality class EU 2<br />

3 1 Fan<br />

4 1 Connection (terminal block)<br />

5 1 Capacitor<br />

FLA 250<br />

KTA45980<br />

Order Information<br />

230 V AC 115 V AC<br />

Description Order no. Order no.<br />

Standard air filtered fan FL 250 60715-071 60715-073<br />

Air filtered fan FL 250 EMC 60715-108 60715-110<br />

Outlet/Inlet filter FLA 250/300 Standard<br />

(Delivery comprises items 1 + 2), 1 piece<br />

60715-091<br />

Outlet/Inlet filter FLA 250/300 EMC<br />

(Delivery comprises items 1 + 2), 1 piece<br />

60715-126<br />

Replacement filter for FL 250 / 300 / FLA 250 / 300,<br />

(Delivery comprises item 2), 3 pieces<br />

60715-096<br />

KTA46385<br />

Technical data of the fan<br />

Voltage in V 230 115<br />

Frequency in Hz 50 / 60 50 / 60<br />

Air capacity with filter (free blowing ) in m 3 /h 131 131<br />

Combination FL + FLA in m 3 /h 95 95<br />

Noise level per fan in dB (A) 55 55<br />

Max. stat. pressure in PA 57 57<br />

Max. ambient temperature in °C -10...+50 -10...+50<br />

Power consumption in W 18 20<br />

Filter efficiency in % 83 83<br />

Note<br />

EMC version, assembly cut-out 2 mm larger (height, width)<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

2.20<br />

UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> <strong>control</strong> – Air filtered fan<br />

FL 300<br />

Air filtered fan FL 300<br />

Air filtered fan<br />

Simple conversion from pressure to suction mode<br />

EMC design<br />

Type of protection IP54<br />

Delivery comprises (completely assembled)<br />

Item Qty Description<br />

1 1 Front grille and case, Plastic ABS, RAL 7035,<br />

self-extinguishing, similar to UL 94 V-0<br />

2 1 Filter mat, 350 g/m 3 quality class EU 2<br />

3 1 Fan<br />

4 1 Connection (terminal block)<br />

5 1 Capacitor<br />

FLA 300<br />

KTA45980<br />

Order Information<br />

230 V AC 115 V AC<br />

Description Order no. Order no.<br />

Standard air filtered fan FL 300 60715-075 60715-077<br />

Air filtered fan FL 300 EMC 60715-112 60715-114<br />

Outlet/Inlet filter FLA 250/300 Standard<br />

(Delivery comprises items 1 + 2), 1 piece<br />

60715-091<br />

Outlet/Inlet filter FLA 250/300 EMC<br />

(Delivery comprises items 1 + 2), 1 piece<br />

60715-126<br />

Replacement filter for FL 250 / 300 / FLA 250 / 300,<br />

(Delivery comprises item 2), 3 pieces<br />

60715-096<br />

KTA46385<br />

Technical data of the fan<br />

Voltage in V 230 115<br />

Frequency in Hz 50 / 60 50 / 60<br />

Air capacity with filter (free blowing ) in m 3 /h 249 249<br />

Combination FL + FLA in m 3 /h 210 210<br />

Noise level per fan in dB (A) 55 55<br />

Max. stat. pressure in PA 89 89<br />

Max. ambient temperature in °C -10...+50 -10...+50<br />

Power consumption in W 18 20<br />

Filter efficiency in % 83 83<br />

Note<br />

EMC version, assembly cut-out 2 mm larger (height, width)<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.21


<strong>Climate</strong> <strong>control</strong> – Air filtered fan<br />

FL 500<br />

Air filtered fan FL 500<br />

Air filtered fan<br />

EMC design<br />

Type of protection IP54<br />

Available on request, can be converted at the factory from<br />

pressure to suction mode<br />

FLA 500<br />

KTA45981<br />

Delivery comprises (completely assembled)<br />

Item Qty Description<br />

1 1 Front grille and case, Plastic ABS, RAL 7035,<br />

self-extinguishing, similar to UL 94 V-0<br />

2 1 Filter mat, 350 g/m 3 quality class EU 2<br />

3 1 Fan<br />

4 1 Connection (terminal block)<br />

5 1 Capacitor<br />

Order Information<br />

230 V AC 115 V AC<br />

Description Order no. Order no.<br />

Standard air filtered fan FL 500 60715-079 60715-081<br />

Air filtered fan FL 500 EMC 60715-116 60715-118<br />

Outlet/Inlet filter FLA 500/600 Standard<br />

(Delivery comprises items 1 + 2), 1 piece<br />

60715-093<br />

Outlet/Inlet filter FLA 500/600 EMC<br />

(Delivery comprises items 1 + 2), 1 piece<br />

60715-128<br />

Replacement filter for FL 500/600 FLA 500/600,<br />

(Delivery comprises item 2), 3 pieces<br />

60715-097<br />

KTA46386<br />

Technical data of the fan<br />

Voltage in V 230 115<br />

Frequency in Hz 50 / 60 50 / 60<br />

Air capacity with filter (free blowing ) in m 3 /h 461 461<br />

Combination FL + FLA in m 3 /h 350 350<br />

Noise level per fan in dB (A) 69 69<br />

Max. stat. pressure in PA 205 205<br />

Max. ambient temperature in °C -10...+50 -10...+50<br />

Power consumption in W 56 56<br />

Filter efficiency in % 83 83<br />

Note<br />

EMC version, assembly cut-out 2 mm larger (height, width)<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

2.22<br />

UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> <strong>control</strong> – Air filtered fan<br />

FL 600<br />

Air filtered fan FL 600<br />

Air filtered fan<br />

EMC design<br />

Type of protection IP54<br />

Available on request, can be converted at the factory from<br />

pressure to suction mode<br />

FLA 600<br />

KTA45981<br />

Delivery comprises (completely assembled)<br />

Item Qty Description<br />

1 1 Front grille and case, Plastic ABS, RAL 7035,<br />

self-extinguishing, similar to UL 94 V-0<br />

2 1 Filter mat, 350 g/m 3 quality class EU 2<br />

3 1 Fan<br />

4 1 Connection (terminal block)<br />

5 1 Capacitor<br />

Order Information<br />

230 V AC 115 V AC<br />

Description Order no. Order no.<br />

Standard air filtered fan FL 600 60715-083 60715-085<br />

Air filtered fan FL 600 EMC 60715-120 60715-122<br />

Outlet/Inlet filter FLA 500/600 Standard<br />

(Delivery comprises items 1 + 2), 1 piece<br />

60715-093<br />

Outlet/Inlet filter FLA 500/600 EMC<br />

(Delivery comprises items 1 + 2), 1 piece<br />

60715-128<br />

Replacement filter for FL 500/600 FLA 500/600,<br />

(Delivery comprises item 2), 3 pieces<br />

60715-097<br />

KTA46386<br />

Technical data of the fan<br />

Voltage in V 230 115<br />

Frequency in Hz 50 / 60 50 / 60<br />

Air capacity with filter (free blowing ) in m 3 /h 625 625<br />

Combination FL + FLA in m 3 /h 450 450<br />

Noise level per fan in dB (A) 71 71<br />

Max. stat. pressure in PA 225 225<br />

Max. ambient temperature in °C -10...+50 -10...+50<br />

Power consumption in W 155 155<br />

Filter efficiency in % 83 83<br />

Note<br />

EMC version, assembly cut-out 2 mm larger (height, width)<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.23


Overview ................. 0<br />

<strong>Climate</strong> <strong>control</strong> – Heat exchanger<br />

Cabinets.................. 1<br />

<strong>Climate</strong> Control....... 2<br />

Cases ...................... 3<br />

Subracks/<br />

19" chassis............. 4<br />

Modules .................. 5<br />

00902001<br />

Systems .................. 6<br />

Power supply<br />

units........................ 7<br />

Backplanes ............. 8<br />

Accessories ............ 9<br />

Appendix............... 10<br />

On the Internet further important information can be found<br />

under www.schroff.biz<br />

Ordering data<br />

Specifications about power dissipation<br />

Individual configuration, Download of drawings<br />

Modifications, customized solutions<br />

2.24 UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> <strong>control</strong> – Heat exchanger<br />

Overview ............ 2.24<br />

Efficient heat dissipation for indoor and outdoor enclosures<br />

Low weight<br />

Compact dimensions<br />

Cooling devices with integrated evaporation of condensation water<br />

Heat exchanger<br />

Heat exchanger<br />

Indoor application<br />

Standard heat exchanger 230 V and 115 V<br />

Outdoor application<br />

For further information see www.schroff.biz<br />

01102013<br />

Cooling Units<br />

Cooling Units<br />

Indoor application<br />

Standard cooling devices 400 W to 2600 W<br />

Outdoor application<br />

For further information see www.schroff.biz<br />

00902001<br />

Micro<strong>control</strong>ler<br />

Micro<strong>control</strong>ler<br />

For <strong>control</strong> and supervision<br />

Diagnostic messages<br />

Potential free alarm outputs<br />

For further information see www.schroff.biz<br />

00902002<br />

W<br />

Selection Guide<br />

Selection Guide<br />

˚C<br />

KT6741<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.25


<strong>Climate</strong> <strong>control</strong> – Accessories<br />

Heaters 20W up to 150W<br />

Accessories<br />

Simple and fast assembly with clip-on attachment<br />

Press-on terminal connection saves time on assembly<br />

Temperature-limiting<br />

Delivery comprises (fully assembled)<br />

01102004<br />

Item Qty Description<br />

1 1 Heater element, (PTC resistance)<br />

self-regulating voltage range 110-250 V AC/DC<br />

2 Heating body, anodised aluminium extrusion<br />

Assembly: clip for 35 mm rail EN 50022<br />

3 Connections for type HKG = lead 300 mm long 2 core<br />

0.75 mm 2<br />

Connections for type HG = Terminal block for<br />

3 x 0.5 - 0.25 mm 2 wire<br />

Order Information<br />

HGK 20 W HGK 30 W HG 45 W HG 75 W HG 100 W HG 150 W<br />

Description Order no. Order no. Order no. Order no. Order no. Order no.<br />

Heaters 20 W up to 150 W 60715-019 60715-020 60715-021 60715-022 60715-023 60715-030<br />

Support rail for heaters, 1 piece 20715-001<br />

Technical data<br />

Type HGK HGK HG HG HG HG<br />

Heater output in W 20 30 45 75 100 150<br />

Surface temperature in °C approx. 90 approx. 100 approx. 105 approx. 120 approx. 130 approx.140<br />

Current at switch-on approx. in A 1 1.5 1 1.8 2.4 4<br />

Type of protection IP 54 IP 54 IP 20 IP 20 IP 20 IP 20<br />

Class of protection II II I I I I<br />

Dimensions H × B × T in mm 60 × 50 × 25 70 × 50 × 25 65 × 70 × 25 140 × 70 × 25 140 × 70 × 25 220 × 70 × 25<br />

Weight in kg 0.11 0.12 0.3 0.5 0.5 0.8<br />

Test symbols VDE, CE VDE, CE CE CE CE CE<br />

For further information www.schroff.biz/oneClick<br />

z/oneClick<br />

oneClick code = Order no.<br />

2.26<br />

UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> <strong>control</strong> – Accessories<br />

Heater 400 W<br />

Accessories<br />

With temperature <strong>control</strong><br />

Simple and fast assembly with clip-on attachment<br />

Fan freely selectable<br />

Delivery comprises (fully assembled)<br />

01197004<br />

Item Qty Description<br />

1 1 Heater element, high-performance cartridge<br />

2 1 Heating body, anodised aluminium extrusion<br />

Assembly: Clip for 35 mm rail EN 50022<br />

3 1 Terminal connection<br />

4 1 Assembly kit for fan<br />

Order Information<br />

115 V AC 230 V AC<br />

Description Order no. Order no.<br />

Heater 400 W 60715-028 60715-029<br />

Support rail for heaters, 1 piece 20715-001<br />

Protective grille optionally for fan, 1 piece 60197-019<br />

Technical data<br />

Voltage range 115 V AC 230 V<br />

Heater output in W 400 400<br />

Current at switch-on approx. in A 3.5 1.8<br />

Surface temperature with fan in °C approx.140<br />

Type of protection IP 20<br />

Class of protection<br />

I, with GND/earthing<br />

Dimensions:<br />

22 × 120 × 160<br />

Width x Height x Depth in mm<br />

Weight in kg 0.4<br />

Assembly Clip for 35 mm DIN rail EN 50022<br />

Note<br />

Only operate heater in conjunction with fan, danger of<br />

overheating<br />

Single fan (119 mm × 119 mm), see page 2.29<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.27


<strong>Climate</strong> <strong>control</strong> – Accessories<br />

Heater 350/500 W with thermostat and<br />

fan<br />

Accessories<br />

Simple and fast assembly with clip-on attachment<br />

3-pin connecting terminal, separated connection heater/fan<br />

Thermostat from 0 ... 60 °C<br />

Delivery comprises (fully assembled)<br />

Item Qty Description<br />

1 1 Plastic housing, polycarbonate<br />

(RAL 9002, grey-white), clip for 35 mm rail EN 50022<br />

2 1 Heater element, ( PTC resistance), self-regulating<br />

3 1 Fans<br />

Order Information<br />

01197005<br />

Type Weight 115 V AC 230 V AC<br />

kg Order no. Order no.<br />

Heater 350 W 0.9 60715-015 60715-017<br />

Heater 500 W 1.1 60715-016 60715-018<br />

Support rail for heaters, 1 piece 20715-001<br />

Technical data<br />

Voltage range 115 V AC 230 V<br />

Heater output in W 350 550 350 550<br />

Air capacity axial fan m 3 /h 35 45 35 45<br />

Air exit temperature 50 mm<br />

above protective grille in °C<br />

Current at switch-on approx.<br />

in A<br />

Heater element<br />

approx.<br />

150<br />

approx.<br />

160<br />

approx.<br />

150<br />

10.5 12 7 8.5<br />

Resistor (PTC) self-regulating<br />

Connection 3-pin connecting terminal, 2.5 mm 2 ,<br />

separated connection heating/fan<br />

Thermostat Adjustment range 0 ... 60 °C<br />

Control system (<strong>control</strong> Glow lamp<br />

lamp)<br />

Temperature <strong>control</strong> in the event of fan failure<br />

Type of protection IP 00<br />

Class of protection II<br />

Dimensions: height x width x 165 x 100 x 124<br />

depth mm<br />

approx.<br />

160<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

2.28<br />

UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> <strong>control</strong> – Accessories<br />

AC fans / replacement fans<br />

Accessories<br />

Delivery comprises (Individual part)<br />

Item Qty Description<br />

1 1 Fans (width 119 mm, depth 119 mm)<br />

Order Information<br />

Connecting lead<br />

KTA44844<br />

Height<br />

Air capacity<br />

50 Hz, DC<br />

Power consumption<br />

50 Hz<br />

115 V AC 230 V AC<br />

Order no. Order no.<br />

mm m³/h W<br />

25 84 8 20713-146 20713-142<br />

25 108 14 20713-147 20700-001<br />

38 162 15 20713-244 20713-243<br />

Connecting lead PVC (2 x 0.75 mm²), 1 m long with 2 faston<br />

connectors 2.8 x 0.8 mm, 1 piece<br />

21101-246<br />

Protective grille bolt-on fibreglass reinforced plastic (PA),<br />

black, complies with UL 94 V-0 requirements, 1 piece<br />

60225-053<br />

Protective grille clip-in fibreglass reinforced plastic (PA),<br />

black, complies with UL 94 V-0 requirements, 1 piece<br />

60225-052<br />

Bolt-on protective grille<br />

KTA43091<br />

Technical data AC fans<br />

Dimensions 25 × 119 × 119 25 × 119 × 119 38 × 119 × 119<br />

H×W×D<br />

in mm<br />

Frequency in Hz 50 60 50 60 50 60<br />

Air capacity in 84 90 108 120 162 192<br />

m 3 /h<br />

Noise level per 29 30 34 38 37 41<br />

fan in dB (A)<br />

Max. stat. 23 21 41 41 73 88<br />

pressure in PA<br />

Max. ambient 70 70 70 70 70 70<br />

temperature in<br />

°C<br />

Power<br />

8 7 14 11 15 14<br />

consumption in<br />

W<br />

KTA45223<br />

For further information www.schroff.biz/oneClick<br />

z/oneClick<br />

oneClick code = Order no.<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.29


<strong>Climate</strong> <strong>control</strong> – Accessories<br />

DC fans<br />

Accessories<br />

Delivery comprises (Individual part)<br />

Item Qty Description<br />

1 1 Fans height 38 mm (width 119 mm, depth 119 mm)<br />

1a 1 Fans height 25 mm (width 119 mm, depth 119 mm)<br />

with cable for connection, length 55 mm, 2 fast-on<br />

connectors 2.8 x 0.8 mm<br />

Connecting lead<br />

KTA44844<br />

Order Information<br />

Height<br />

Air capacity<br />

50 Hz, DC<br />

Power consumption<br />

50 Hz<br />

Input<br />

voltage<br />

Order no.<br />

mm m³/h W V<br />

25 153 7 24 20713-172<br />

38 184 8 24 20713-240<br />

38 184 8 12 20713-241<br />

38 184 8 48 20713-242<br />

Connecting lead PVC (2 x 0.75 mm²), 1 m long with 2<br />

fast-on connectors 2.8 x 0.8 mm, 1 piece<br />

21101-246<br />

Protective grille bolt-on fibreglass reinforced plastic<br />

(PA), black, complies with UL 94 V-0 requirements, 1 piece<br />

60225-053<br />

Protective grille clip-in fibreglass reinforced plastic (PA),<br />

black, complies with UL 94 V-0 requirements, 1 piece<br />

60225-052<br />

Bolt-on protective grille<br />

KTA43091<br />

KTA45223<br />

Technical data DC fans<br />

Voltage in V DC 24 24 12 48<br />

Dimensions<br />

H × W × D<br />

in mm<br />

Air capacity in<br />

m 3 /h<br />

Noise level per<br />

fan in dB (A)<br />

Max. stat.<br />

pressure in PA<br />

Max. ambient<br />

temperature in<br />

°C<br />

Power<br />

consumption in<br />

W<br />

25 × 119 ×<br />

119<br />

38 × 119 ×<br />

119<br />

38 × 119 ×<br />

119<br />

195 184 184 184<br />

41.5 42 42 42<br />

50.5 68 68 68<br />

70 70 70 70<br />

7 8 8 8<br />

38 × 119 ×<br />

119<br />

Note<br />

Connector lead does not fits with fan 25 mm hight<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

2.30<br />

UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> <strong>control</strong> – Accessories<br />

Speed <strong>control</strong> for fans<br />

Accessories<br />

Speed <strong>control</strong> for 19" fan, 19" blower unit or top cover fan tray<br />

The airflow volume is set depending on:<br />

the ambient temperature<br />

the current energy loss<br />

the actual air resistances<br />

the desired cabinet inner temperature<br />

This has the following advantages:<br />

Functional reliability due to constant cabinet inner temperature<br />

Low noise<br />

01195001<br />

Delivery comprises (assembled)<br />

Item Qty Description<br />

1 1 Speed <strong>control</strong>, see technical data<br />

2 1 Temperature sensor NTC resistor, cable length 1.5 m<br />

3 1 Fan cable, cable length 1.5 m with fast-on connectors<br />

6.3 × 0.8 mm<br />

4 1 Mains cable, cable length 3 m, end isolation stripped<br />

with end sleeves<br />

5 1 Mounting plate for assembly on cabinet upright<br />

6 1 Spring for mounting on the support rail<br />

Order Information<br />

KTA43494<br />

115 V AC 230 V AC<br />

Type Application Order no. Order no.<br />

Single-phase motor 19" fan, blower unit 10713-522 10713-523<br />

Capacitor motor – 10713-524 10713-525<br />

Technical data<br />

KTA43495<br />

Voltage range 110 ... 120 V 220 ... 240 V<br />

Frequency in Hz 50 ... 60 50 ... 60<br />

Input voltage 90 ... 132 V 187 ... 264 V<br />

max. connection power in W 220<br />

possible mains/line frequency 48...62 Hz<br />

Cabinet temperature in °C Adjustment range: +25...+50<br />

Fan speed in % 30...100<br />

Power lead<br />

3 m, end isolation stripped with end<br />

sleeves<br />

Sensor<br />

External NTC resistor<br />

Sensor connection<br />

Plug-in contact and cable 1.5 m<br />

If sensor fails<br />

Maximum speed<br />

Dimensions:<br />

120 × 65 × 40<br />

Width x Height x Depth in mm<br />

Fan connection<br />

Cable 1.5 m with Faston connectors<br />

6.3 x 0.8 mm<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.31


<strong>Climate</strong> <strong>control</strong> – Accessories<br />

Thermostat with integral temperature sensor<br />

Accessories<br />

For switching heater units or fans<br />

Adjustment range 5 ... 60 °C<br />

Order Information<br />

100 ... 130 V AC 200 ... 250 V AC<br />

Description Order no. Order no.<br />

Thermostat with integral temperature<br />

sensor<br />

20715-007 20715-002<br />

Technical data<br />

01102008<br />

Dimensions Height x Width x Depth 75 × 75 × 25<br />

in mm<br />

Adjustment range 5 ... 60 °C<br />

Switching differential<br />

0.5 K<br />

Contact load<br />

(ohmic Load / inductive load)<br />

Contacts<br />

Assembly<br />

Heat (terminal 1–2) 10 A / 4 A<br />

cool (terminal 1–3) 5 A / 2 A<br />

Changeover contact, 1-pin<br />

Bolt-on, alternatively with clip-on<br />

attachment for support rail<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

Thermostat with external temperature sensor<br />

Accessories<br />

External sensor can be positioned near the critical assembly<br />

Adjustment range 20 ... 60 °C<br />

Order Information<br />

Description<br />

Order no.<br />

Voltage range: 90 ... 260 V AC 20715-003<br />

Technical data<br />

01102007<br />

Dimensions Height x Width x Depth 93 × 68 × 44<br />

in mm<br />

Adjustment range 20 ... 60 °C<br />

Switching differential<br />

10 K<br />

Contact load<br />

24 A/10 A<br />

(ohmic load / inductive load)<br />

Contacts<br />

Changeover contact, 1-pin<br />

Assembly<br />

bolt-on<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

2.32<br />

UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> <strong>control</strong> – Accessories<br />

Thermostat with digital display<br />

Accessories<br />

For rack-mounting and panel-mounting<br />

Display changeable from °C to °F<br />

Programmable (secured against unauthorised operation)<br />

Switching differential of 0 ... 10 K freely selectable<br />

3-digit, red display<br />

Order Information<br />

Description<br />

Order no.<br />

Thermostat with digital display 60715-132<br />

Front panel RAL 7035 light grey with cut-out for the<br />

thermostat<br />

30118-315<br />

Front panel anodised with cut-out for the thermostat 30118-267<br />

Front panel 1 U<br />

01197001<br />

SZA45550<br />

Technical data<br />

Operating voltage 115 / 230 V AC (90 ... 260 V AC )<br />

Power consumption in W approx. 3.5<br />

Dimensions Height x Width x Depth 35 × 76 × 59<br />

mm<br />

Assembly cut-out 28.8 × 70.5<br />

Adjustment range in °C -50...+100<br />

Switching differential<br />

0 ... 10 K selectable<br />

Data retention in the event of power Non-volatile memory<br />

failure<br />

Contact load<br />

8 A/3 A<br />

(ohmic Load / inductive load)<br />

Input/sensor<br />

PTC sensor,<br />

-55...+120 °C, cable length 3 m<br />

Contacts<br />

Relay, changeover contact, 1-pin<br />

Type of protection, from(front) IP 54<br />

Connection Screw clamps 2.5 mm 2<br />

Assembly<br />

Mounting with clamping bracket<br />

Assembly<br />

Bolt-on<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.33


<strong>Climate</strong> <strong>control</strong> – Accessories<br />

Hygrostat<br />

Accessories<br />

The hygrostat is used to <strong>control</strong> heating systems to raise the<br />

dewpoint from critical relative air humidity of 65%. -This<br />

prevents condensation and corrosion on components.<br />

Order Information<br />

Description<br />

Order no.<br />

Hygrostat 60715-041<br />

Support rail incl. assembly parts 21101-421<br />

01102006<br />

Technical data<br />

Dimensions Height x Width x Depth 75 × 75 × 25<br />

in mm<br />

Adjustment range of relative air 35 ... 100<br />

humidity in %<br />

Switching differential in % approx. 4<br />

Contact load AC: 24 - 230 V 5 A/0.2 A<br />

(ohmic load / inductive load)<br />

Contact load DC:<br />

max. 60 Watt<br />

Contacts<br />

Changeover contact, 1-pin<br />

Assembly<br />

Bolt-on, alternatively with clip-on<br />

attachment for support rail<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

Inlet IEC<br />

Accessories<br />

For the connection of fans<br />

Bolted housing made of heat-resistant plastic (UL 94 V-0).<br />

10 A / 250 V AC , class of protection I<br />

Order Information<br />

Description<br />

Order no.<br />

Inlet IEC 60715-046<br />

KTA45246<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

2.34<br />

UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> <strong>control</strong> – Accessories<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.35