20.01.2015 Views

Climate control

Climate control

Climate control

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Overview ................. 0<br />

<strong>Climate</strong> <strong>control</strong><br />

Cabinets.................. 1<br />

<strong>Climate</strong> Control....... 2<br />

Cases ...................... 3<br />

Subracks/<br />

19" chassis............. 4<br />

High air capacity<br />

Can be adapted on subracks<br />

Modules .................. 5<br />

Systems .................. 6<br />

Power supply<br />

units........................ 7<br />

Backplanes ............. 8<br />

For indoor and outdoor applications<br />

Microcomputer <strong>control</strong>led<br />

Accessories ............ 9<br />

Appendix............... 10<br />

2.0 UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> <strong>control</strong><br />

Overview<br />

.............. 2.0<br />

Service ................. 2.2<br />

Degree of protection IP 54<br />

Easy to mount – clip in<br />

19"-fan units........ 2.4<br />

Air filtered fans .. 2.16<br />

Heat exchanger.. 2.24<br />

Accessories<br />

Heaters . . . . . . . . . . 2.26<br />

Fans . . . . . . . . . . . . 2.29<br />

Speed <strong>control</strong> . . . . . 2.31<br />

Thermostat . . . . . . . 2.32<br />

Hygrostat . . . . . . . . 2.34<br />

With or without fan<br />

Quick and easy to mount<br />

Cooling concept with Flowtherm simulation<br />

Calculation aid on the internet<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.1


Overview ................. 0<br />

<strong>Climate</strong> Control – Service – Overview<br />

Cabinets.................. 1<br />

‘FLOTHERM’ Simulation<br />

Project support through<br />

simulation software<br />

<strong>Climate</strong> Control....... 2<br />

Cases ...................... 3<br />

Subracks/<br />

19" chassis............. 4<br />

With the simulation software ’FLOTHERM’ heat field and problem<br />

areas can be recognised during the concept phase. Cooling<br />

concepts for assemblies up to total cases and cabinet systems can<br />

be analysed. Our ’FLOTHERM’ specialists will assist you in<br />

simulating your design.<br />

Your advantage:<br />

You analyse and remove problems in advance during<br />

the prototype phase<br />

You therefore increase the performance and the reliability<br />

of your system<br />

You shorten your development times<br />

Modules .................. 5<br />

Systems .................. 6<br />

Power supply<br />

units........................ 7<br />

Backplanes ............. 8<br />

01103050<br />

RESULT:<br />

Cost savings<br />

Your input:<br />

Capacity loss of the various components<br />

(units, boards, ...)<br />

Environmental and working conditions (outside temperature,<br />

maximum inside temperature)<br />

System assembly (geometry)<br />

RESULT:<br />

Joint establishment of the thermal analysis<br />

Optimum arrangement of components<br />

Accessories ............ 9<br />

01103051<br />

Appendix............... 10<br />

Further important information can be found on the internet<br />

under www.schroff.biz<br />

2.2 UK 04/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> Control – Service – Overview<br />

Overview .............. 2.2<br />

Cooling Concepts with Standard Products<br />

<strong>Climate</strong> <strong>control</strong> of Cabinets<br />

and Cases<br />

Specific heat removal<br />

from systems<br />

19" fan units<br />

19" blower units<br />

01102050 0092050 01102051<br />

Air filtered fans<br />

Heat exchanger/<br />

Air conditioners<br />

V ° (m 3 /h)<br />

V ° (m 3 /h)<br />

Configuration in the Internet (www.schroff.biz)<br />

On our home page on the internet you will find assistance when<br />

selecting standard components.<br />

Describe your basic requirements by stating the following:<br />

installed heat loss<br />

requested temperature inside the cabinet<br />

Configuration<br />

via the Internet<br />

P V (W)<br />

A41771<br />

maximum outside temperature at the installation site<br />

type of installation<br />

and we will direct you to possible alternatives from our standard<br />

program.<br />

For further information ... www.schroff.biz<br />

UK 04/2003<br />

2.3


Overview ................. 0<br />

<strong>Climate</strong> <strong>control</strong> – 19"-fan units<br />

Cabinets.................. 1<br />

<strong>Climate</strong> Control....... 2<br />

Cases ...................... 3<br />

Subracks/<br />

19" chassis............. 4<br />

Modules .................. 5<br />

01102012<br />

Systems .................. 6<br />

Power supply<br />

units........................ 7<br />

Mechanical safety device<br />

for power lead<br />

01197002<br />

Configure the 19" fan units<br />

individually<br />

01194004<br />

Backplanes ............. 8<br />

Accessories ............ 9<br />

Appendix............... 10<br />

Standards<br />

19" mounting to IEC 60297-3<br />

Mechanical protection according to EN 292<br />

Touch protection according to EN 294<br />

Electrical safety according to EN 60335 part 1<br />

Modifications<br />

Other air capacities<br />

DC voltages<br />

Filter mats<br />

Other dimensions<br />

Further important information can be found on the internet<br />

under www.schroff.biz<br />

Configurator 19“fan units<br />

2.4 UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> <strong>control</strong> – 19"-fan units<br />

19"-fan units........ 2.4<br />

19" fan units<br />

Removal of heat by 19" fan units<br />

High running performance<br />

Mechanical touch protection<br />

Adaption to subrack possible<br />

With or without switch<br />

19" Blowers<br />

For Cooling of single components and assemblies<br />

Height 1 U<br />

19" fan units<br />

1 U with/without front<br />

switch ........................2.8<br />

1 U, speed-<strong>control</strong>led<br />

and monitored .........2.10<br />

Individual configurations can be assembled with the help of the<br />

configurator on our homepage (www.schroff.biz)<br />

01102052<br />

19"-Pressure fans<br />

For Cooling of single components and assemblies<br />

Height 2 U and 3 U<br />

19" blower unit<br />

2 U with<br />

tangential fan ..........2.11<br />

2 U (160, 220 mm<br />

deep)........................2.12<br />

Supplementary fan<br />

for 2 U fan unit.........2.13<br />

3 U............................2.14<br />

Ventilation panel<br />

for 3 U ......................2.15<br />

01102053<br />

V ° (m 3 /h)<br />

Selection Guide<br />

Selection guide<br />

Versions .....................2.6<br />

Dimensions ................2.7<br />

P V (W)<br />

A41771<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.5


<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />

19" fan versions<br />

Fan for assembly in the 19" mounting space<br />

High air throughput<br />

Long service life<br />

Tested and approved<br />

The 19" fans are available in two versions:<br />

19" blower unit<br />

01192002<br />

19" fan unit<br />

19" blower unit<br />

19" subracks with 160 or 220 mm standard board format are given<br />

optimum cooling by means of blower units, even if several<br />

subracks (each with blower units) are mounted one above the<br />

other.<br />

01192006<br />

19" fan unit<br />

These fans extract the heat from plug-in units and are available<br />

with or without illuminated switches. A low-noise version works<br />

with temperature-dependent speed <strong>control</strong> and its function is<br />

monitored. 19" fan units can also be configured individually<br />

(www.schroff.biz).<br />

Service life<br />

The service life of the fans depends on the way they are used. At<br />

an ambient temperature of 40 °C, it is approx. 40000 – 60000<br />

hours.<br />

01102016<br />

Standards<br />

19" mounting complying with IEC 60 297-3-101. Plastics are selfextinguishing<br />

to comply with UL 94 V 1. PPO and fibreglass<br />

reinforced plastics are self-extinguishing to comply with<br />

UL 94 V-0. Mechanical protection in accordance with EN 292.<br />

Contact protection in accordance with EN 294. Electrical safety in<br />

accordance with EN 60335, Part 1.<br />

19" fan racks<br />

2.6<br />

UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />

19" fan dimensions<br />

V (m 3 /h)<br />

19" blower unit<br />

19" fan unit<br />

For local heat dissipation, the airflow volume required to extract<br />

the (energy loss) heat is calculated.<br />

P v (W)<br />

A41771<br />

Note<br />

The cabinet ventilation is not taken into account here.<br />

The required airflow volume is calculated as follows:<br />

V= (f x P v ) / T<br />

The air constant f = 3.3 mm 3 K/Wh.<br />

T is the difference between the ambient temperature and the<br />

internal temperature.<br />

Example<br />

- Pv = 600 W<br />

- internal temperature = 25 °C<br />

- ambient temperature = 30 °C<br />

1. T = T i – T a = 30 °C – 25 °C = 5 K<br />

2. From P v = 600 W for curve for T =5 K<br />

3. From the point of intersection down to the airflow volume<br />

V = 400 m 3 /h<br />

19" fan racks<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.7


geprüfte<br />

Sicherheit<br />

<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />

19" fan unit 1 U<br />

19" fan racks<br />

Mechanical strain relief for mains cable<br />

Adaptation to subracks possible<br />

Contact protection in accordance with EN 294.<br />

Delivery comprises (assembled and wired)<br />

01194002<br />

Item Qty Description<br />

1 1 Front panel 1 U, aluminium 3 mm, anodised<br />

2 1 Case with grille, 1 mm steel, AIZn<br />

3 3 / 6 Fan, see ordering information<br />

4 1 IEC 320 input socket<br />

5 1 Safety device, mechanical strain relief for mains input<br />

cable<br />

6 1 Connection lead for 24 V DC supplied (please order<br />

separately for AC fan)<br />

Order Information<br />

230 V AC 115 V AC 24 V DC<br />

Order No. Order No. Order No.<br />

10713-100 10713-102 10713-103<br />

KTA44857<br />

10713-104 10713-106 10713-107<br />

KTA44306<br />

KTA44858<br />

Adapter bracket Subrack, europac to fan tray, incl.<br />

assembly parts<br />

21101-104<br />

Adapter bracket Subrack, europacPRO to fan tray, incl.<br />

assembly parts<br />

21101-954<br />

Equipment cable for AC fan, UTE, 2.5 m 60103-131<br />

Equipment cable for AC fan, British standard, 2.5 m 60103-137<br />

Equipment cable for AC fan, IEC, 2.5 m 60103-141<br />

Technical data of the individual fans<br />

Voltage 230 V AC 115 V AC 24 V DC<br />

Frequency in Hz 50 60 50 60 -<br />

Air capacity (free blowing) in m 3 /h 162 192 162 192 184<br />

Noise level per fan in dB (A) 37 41 37 41 42<br />

Max. stat. pressure in PA 73 88 73 88 68<br />

Max. ambient temperature in °C 70 70 70 70 70<br />

Power consumption in W 15 14 15 14 8<br />

Replacement fans, see chapter '<strong>Climate</strong> <strong>control</strong> - accessories'<br />

2.8<br />

UK 08/2003<br />

For further information ... www.schroff.biz


geprüfte<br />

Sicherheit<br />

<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />

19" fan unit 1 U<br />

with front switch<br />

19" fan racks<br />

Front mains switch plus additional mains output socket<br />

Mechanical strain relief for mains input and mains output cable<br />

Adaptation to subracks possible<br />

Contact protection in accordance with EN 294.<br />

Delivery comprises (assembled and wired)<br />

01194003<br />

Item Qty Description<br />

1 1 Front panel 1 U, aluminium 3 mm, anodised<br />

2 1 Case with grille, 1 mm steel, AIZn<br />

3 3 / 6 Fan, see ordering information<br />

4 1 IEC 320 input socket<br />

5 1 IEC 320 output connector<br />

6 2 Safety device, mechanical strain relief for mains cable<br />

7 1 Illuminated switch, green, plain for 24 V DC<br />

8 1 Connection lead for 24 V DC supplied (please order<br />

separately for AC fan)<br />

Order Information<br />

230 V AC 115 V AC 24 V DC<br />

Order no. Order no. Order no.<br />

01197002<br />

10713-108 10713-110 10713-111<br />

KTA44857<br />

10713-112 10713-114 10713-115<br />

KTA44858<br />

Adapter bracket Subrack, europac to fan tray, incl.<br />

assembly parts<br />

21101-104<br />

Adapter bracket Subrack, europacPRO to fan tray, incl.<br />

assembly parts<br />

21101-954<br />

Equipment cable for AC fan, UTE, 2.5 m 60103-131<br />

Equipment cable for AC fan, British standard, 2.5 m 60103-137<br />

Equipment cable for AC fan, IEC, 2.5 m 60103-141<br />

Equipment cable for power output, 2.5 m 60197-053<br />

KTA45963<br />

Technical data of the individual fans<br />

Voltage 230 V AC 115 V AC 24 V DC<br />

Frequency in Hz 50 60 50 60 -<br />

Air capacity (free blowing) in m 3 /h 162 192 162 192 184<br />

Noise level per fan in dB (A) 37 41 37 41 42<br />

Max. stat. pressure in PA 73 88 73 88 68<br />

Max. ambient temperature in °C 70 70 70 70 70<br />

Power consumption in W 15 14 15 14 8<br />

Replacement fans, see chapter '<strong>Climate</strong> <strong>control</strong> - accessories'<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.9


<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />

19" fan 1 U,<br />

speed-<strong>control</strong>led and monitored<br />

19" fan racks<br />

Noise optimisation through temperature-dependent speed<br />

<strong>control</strong><br />

Temperature range selectable 20 ... 40 °C and 30 ... 50 °C<br />

External sensor (with sensor break max. speed.)<br />

Function monitoring with LEDs and via potential-free contacts<br />

Contact protection in accordance with EN 292.<br />

01198001<br />

Delivery comprises (assembled and wired)<br />

Item Qty Description<br />

1 1 Front panel 1 U, aluminium 3 mm, anodised<br />

2 1 Case with grille, 1 mm steel, AIZn<br />

3 3 DC-fan<br />

4 1 Connection lead, cable length 2.5 m, open end<br />

5 1 Temperature sensor, NTC resistor, cable length 1.5 m<br />

Order Information<br />

Description<br />

Order no.<br />

19" fan 1 U, speed-<strong>control</strong>led and monitored 10713-099<br />

Filter mat for 19" fan unit, 3 pieces, please order<br />

separately<br />

60713-169<br />

Control range<br />

KTA43398<br />

Technical data of the individual fans<br />

Voltage<br />

24 V DC<br />

Air capacity in m 3 /h 80...170<br />

Noise level per fan in dB (A) max. 45<br />

Max. stat. pressure in PA max. 70<br />

Max. ambient temperature in °C 65<br />

Power consumption in W 5.3<br />

Monitoring signal<br />

KTA43399<br />

Technical data Control / monitoring<br />

Control range Change-over switch from 20...40 °C to 30...50 °C<br />

Sensor<br />

External, NTC resistor, cable length 1.5 m<br />

Sensor connection Rear plug-in contact, with sensor break max.<br />

speed<br />

Signal for<br />

Speed 60, 20% nominal speed;<br />

switch-on delay 60, 4 s, signal delay 60, 1 s<br />

(see 'Monitoring signal')<br />

Signalling<br />

Display via LEDs<br />

Potential-free contact (changeover contact),<br />

power 20 W, voltage max. 100 V<br />

Open collector available on request<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

n = speed, S = signal, n A = speed threshold value "alarm"<br />

KTA43400<br />

2.10<br />

UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />

Blower unit 2 U<br />

with tangential fan<br />

19" fan racks<br />

High air capacity<br />

Integrated filter mat<br />

2 versions:<br />

- LE1: 19" full width<br />

- LE2: 19" reduced width, for easy assembly<br />

01192009<br />

Delivery comprises (assembled)<br />

Item Qty Description<br />

1 1 Front grille 2 U, PPO, UL 94 V-0<br />

2 1 Filter mat, fibre, filter class EU 2<br />

3 1 Case with grille, PA 6.6, UL 94 V-0<br />

4 1 Fans<br />

5 1 Terminal connection strip<br />

Order Information<br />

230 V AC 115 V AC<br />

Description Order no. Order no.<br />

LE 1 60713-001 60713-003<br />

LE 2 60713-002 60713-004<br />

Spare filter mat 10 pieces 20705-008<br />

Technical data<br />

A3532<br />

Voltage in V 230 V AC 115 V AC<br />

Frequency in Hz 50 60 50 60<br />

Air capacity in m 3 /h 300 310 300 310<br />

Noise level per fan in dB (A) 53 54 53 54<br />

Max. stat. pressure in PA 65 70 65 70<br />

Max. ambient temperature in °C 65 65 65 65<br />

Power consumption in W 40 50 40 50<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

01103056<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.11


<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />

19" blower unit 2U<br />

(160, 220 mm deep)<br />

19" fan racks<br />

Integrated air baffle prevents heat accumulation on plug-in units<br />

underneath<br />

Optional rear supplementary fan 2 U<br />

Adaptation to subracks possible<br />

01194005<br />

Delivery comprises (assembled and wired)<br />

Item Qty Description<br />

1 1 Front grille 2 U, PPO, UL 94 V-0<br />

2 1 Filter mat, fibre, filter class EU 2<br />

3 1 Case, 1 mm steel, AIZn<br />

4 3 Fan, see ordering information<br />

5 1 IEC 320 input socket<br />

6 1 Safety device, mechanical strain relief for mains input<br />

cable<br />

7 1 Equipment cable for 24 V DC supplied (please order<br />

separately for AC fan)<br />

01103054<br />

A3527V<br />

Order Information<br />

Voltage<br />

airflow capacity at 50/60 Hz<br />

230 V AC 230 V AC 115 V AC 115 V AC 24 V DC<br />

108/120 m 3 /h 162/192 m 3 /h 108/120 m 3 /h 162/192 m 3 /h 184 m 3 /h<br />

Type Order No. Order No. Order No. Order No. Order No.<br />

for board depth 160 mm 10713-518 10713-534 10713-520 10713-536 10713-537<br />

for board depth 220 mm – 10713-526 – 10713-528 10713-529<br />

Equipment cable for AC fan, UTE, 2.5 m 60103-131<br />

Equipment cable for AC fan, British standard, 2.5 m 6010<br />

Equipment cable for AC fan, IEC, 2.5 m 60103-141<br />

Adapter bracket Subrack, europac to fan tray, incl. assembly parts 21101-104<br />

Adapter bracket Subrack, europacPRO to fan tray, incl. assembly parts 21101-954<br />

Spare filter mat 3 pieces 60713-501<br />

Technical data<br />

of the individual fans<br />

Voltage 230 V AC 115 V AC 24 V DC<br />

Frequency in Hz 50 60 50 60 50 60 50 60 -<br />

Air capacity in m 3 /h 108 120 162 192 108 120 162 192 184<br />

Noise level per fan in dB (A) 34 38 37 41 34 38 37 41 42<br />

Max. stat. pressure in PA 41 41 73 88 41 41 73 88 88<br />

Max. ambient temperature in °C 70 70 70 70 70 70 70 70 70<br />

Power consumption in W 14 11 15 14 14 11 15 14 8<br />

2.12<br />

UK 08/2003<br />

For further information ... www.schroff.biz


geprüfte<br />

Sicherheit<br />

<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />

Supplementary fan for 2 U<br />

fan unit<br />

19" fan racks<br />

2 U mounting space:<br />

the use of the supplementary fan means that plug-in units<br />

beneath the 19" blower unit can be cooled<br />

No additional power supply necessary: connection via 19"<br />

blower unit, 2 U<br />

Delivery comprises<br />

01194006<br />

Item Qty Description<br />

1 1 Case with grille, 1 mm steel, AIZn<br />

2 4 Fans<br />

3 1 Connector (electrical connection via connector on the<br />

19" blower unit)<br />

4 1 Safety device (mechanical strain relief for mains input<br />

cable)<br />

Order Information<br />

230 V AC 115 V AC<br />

Description Order no. Order no.<br />

Supplementary fan for 2 U fan unit 10713-530 10713-532<br />

Technical data of the individual fans<br />

KTA44447<br />

Voltage 230 V AC 115 V AC<br />

Frequency in Hz 50 60 50 60<br />

Air capacity in m 3 /h 45 54 45 54<br />

Noise level per fan in dB (A) 33 38 33 38<br />

Max. stat. pressure in PA 44 63 44 63<br />

Max. ambient temperature<br />

70 70 70 70<br />

in °C<br />

Power consumption in W 10 8 10 8<br />

Replacement fans, see chapter '<strong>Climate</strong> <strong>control</strong> - accessories'<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

01103055<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.13


<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />

19" blower unit 3 U<br />

19" fan racks<br />

This blower unit can be re-equipped for different cooling concepts<br />

using cover plates<br />

Specific air supply to subracks<br />

Air supply in the rear cabinet area<br />

Connection options for hoses for specific air supply<br />

01102017<br />

Delivery comprises (assembled and wired)<br />

Item Qty Description<br />

1 1 perforated hinged front panel, 2.5 mm aluminium<br />

2 1 Filter mat, fibre, filter class G 2 complying with EN 779<br />

3 1 Case, 1 mm steel, AIZn<br />

4 1 Radial fan<br />

5 1 IEC 320 inlet socket<br />

6 1 Safety device, mechanical strain relief for mains input<br />

cable<br />

Order Information<br />

230 V AC 115 V AC<br />

Description Order no. Order no.<br />

19" blower unit 3 U<br />

Equipment cable, UTE, 2.5 m<br />

Equipment cable, British standard, 2.5 m<br />

Equipment cable, IEC, 2.5 m<br />

10713-546 10713-547<br />

60103-131<br />

60103-137<br />

60103-141<br />

Adapter bracket Subrack, europac to fan tray, incl.<br />

assembly parts<br />

21101-958<br />

Adapter bracket Subrack, europacPRO to fan tray, incl.<br />

assembly parts<br />

Spare filter mat 3 pieces<br />

21101-954<br />

60713-868<br />

Technical data<br />

01103052<br />

Voltage 230 V AC 115 V AC<br />

Frequency in Hz 50 60 50 60<br />

Air capacity in m 3 /h 570 620 570 615<br />

Noise level per fan in dB (A) 62 64 64 67<br />

Max. stat. pressure in PA 320 405 320 420<br />

Max. ambient temperature in °C 50 55 60 60<br />

Power consumption in W 58 75 57 81<br />

Fan trays for other cooling concepts, see next page 2.15<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

2.14<br />

UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> <strong>control</strong> – 19" fan racks<br />

Ventilation panel for<br />

19" blower unit 3 U<br />

19" fan racks<br />

For 19" blower unit 3 U<br />

Order Information<br />

Item Description Qty Order no.<br />

7 Front fan panel, 1 mm steel, AlZn 1 20713-504<br />

8<br />

Ventilation to rear side: top panel<br />

without perforation ,1 mm steel, AlZn<br />

1 20713-505<br />

9<br />

Ventilation panel with ducting<br />

connection at the top, 1 mm steel, AlZn 1 20713-503<br />

Ventilation panel with ducting<br />

10 connection at the rear, 1 mm steel,<br />

AlZn<br />

1 20713-502<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

01102053<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.15


Overview ................. 0<br />

<strong>Climate</strong> Control – Air filtered fans<br />

Cabinets.................. 1<br />

<strong>Climate</strong> Control....... 2<br />

Cases ...................... 3<br />

Subracks/<br />

19" chassis............. 4<br />

Modules .................. 5<br />

Systems .................. 6<br />

01102005<br />

Power supply<br />

units........................ 7<br />

Backplanes ............. 8<br />

Accessories ............ 9<br />

Improved EMC protection<br />

with EMC filter fans<br />

01102010 01102009<br />

01102011<br />

Easy changeover of operation for<br />

incoming to outgoing air<br />

Assembly simply<br />

by clipping into place<br />

Appendix............... 10<br />

Standards<br />

Protection to IP 54 according to IEC 60529<br />

Earthing according to IEC 60335-2-16<br />

Mechanical protection according to EN 292<br />

Touch protection according to EN 294<br />

Modificatons<br />

Special colour RAL 7032<br />

Other air capacities<br />

Other voltages<br />

Further important Information can be found on the internet<br />

under www.schroff.biz<br />

2.16 UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> Control – Air filtered fans<br />

Overview ............ 2.16<br />

Removal of heat with the help of filtered fans<br />

Protection to IP 54<br />

Assembly simply by clipping into place<br />

Easy changeover of operation for incoming to outgoing air<br />

Flat front grille does not protrude more than 6 mm or 7 mm<br />

Air filtered fans<br />

Air filtered fans<br />

FL 100 ......................2.18<br />

FL 200 ......................2.19<br />

FL 250 ......................2.20<br />

FL 300 ......................2.21<br />

FL 500 ......................2.22<br />

FL 600 ......................2.23<br />

01102050<br />

Selection Guide<br />

KTA45245<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.17


<strong>Climate</strong> <strong>control</strong> – Air filtered fan<br />

FL 100<br />

Air filtered fan FL 100<br />

Air filtered fan<br />

Simple conversion from pressure to suction mode<br />

Type of protection IP54<br />

Delivery comprises (completely assembled)<br />

Item Qty Description<br />

1 1 Front grille and case, plastic PC, RAL 7035,<br />

self-extinguishing, similar to UL 94 V-0<br />

2 1 Filter mat, 150 g/m 3 quality class EU 2<br />

3 1 Fan<br />

4 1 Connection, 2 wires 310 mm long<br />

5 1 Capacitor<br />

Order Information<br />

FLA 100<br />

KTA45979<br />

230 V AC 115 V AC 24 V DC<br />

Description Order no. Order no. Order no.<br />

Air filtered fan FL 100 60715-059 60715-061 60715-063<br />

Outlet/Inlet filterFLA 100<br />

(Delivery comprises items1 + 2), 1 piece<br />

60715-087<br />

Replacement filter for FL 100 / FLA 100,<br />

(Delivery comprises item 2), 3 pieces<br />

60715-094<br />

Technical data of the fan<br />

Voltage in V 230 115 24<br />

Frequency in Hz 50 / 60 50 / 60 DC<br />

Air capacity with filter<br />

24 24 24<br />

(free blowing ) in m 3 /h<br />

Combination FL + FLA in m 3 /h 15 15 15<br />

Noise level per fan in dB (A) 39 39 39<br />

Max. stat. pressure in PA 29 29 29<br />

Max. ambient temperature in °C -10...+60 -10...+60 -20...+60<br />

Power consumption in W 11 11 2.4<br />

Filter efficiency in % 67 67 67<br />

KTA46383<br />

For further information www.schroff.biz/oneClick<br />

Click<br />

oneClick code = Order no.<br />

2.18<br />

UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> <strong>control</strong> – Air filtered fan<br />

FL 200<br />

Air filtered fan FL 200<br />

Air filtered fan<br />

Simple conversion from pressure to suction mode<br />

EMC design<br />

Type of protection IP54<br />

Delivery comprises (completely assembled)<br />

Item Qty Description<br />

1 1 Front grille and case, Plastic ABS, RAL 7035,<br />

self-extinguishing, similar to UL 94 V-0<br />

2 1 Filter mat, 350 g/m 3 quality class EU 2<br />

3 1 Fan<br />

4 1 Connection AC (2-pin terminal block)<br />

connection DC (2 wires, 310 mm long)<br />

5 1 Capacitor<br />

FLA 200<br />

KTA45978<br />

Order Information<br />

230 V AC 115 V AC 24 V DC<br />

Description Order no. Order no. Order no.<br />

Standard air filtered fan FL 200 60715-065 60715-067 60715-069<br />

Air filtered fan FL 200 EMC<br />

60715-102 60715-104 60715-106<br />

Outlet/Inlet filter FLA 200 Standard<br />

(Delivery comprises items 1 + 2), 1 piece<br />

60715-089<br />

Outlet/Inlet filter FLA 200 EMC<br />

(Delivery comprises items 1 + 2), 1 piece<br />

60715-124<br />

Replacement filter for FL 200 / FLA 200,<br />

(Delivery comprises item 2), 3 pieces<br />

60715-095<br />

KTA46384<br />

Technical data of the fan<br />

Voltage in V 230 115 24<br />

Frequency in Hz 50 / 60 50 / 60 DC<br />

Air capacity with filter<br />

56 56 56<br />

(free blowing ) in m 3 /h<br />

Combination FL + FLA in m 3 /h 42 42 42<br />

Noise level per fan in dB (A) 49 49 49<br />

Max. stat. pressure in PA 69 69 69<br />

Max. ambient temperature in °C -10...+50 -10...+50 -20...+50<br />

Power consumption in W 18 20 4.5<br />

Filter efficiency in % 83 83 83<br />

Note<br />

EMC version, assembly cut-out 2 mm larger (height, width)<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.19


<strong>Climate</strong> <strong>control</strong> – Air filtered fan<br />

FL 250<br />

Air filtered fan FL 250<br />

Air filtered fan<br />

Simple conversion from pressure to suction mode<br />

EMC design<br />

Type of protection IP54<br />

Delivery comprises (completely assembled)<br />

Item Qty Description<br />

1 1 Front grille and case, Plastic ABS, RAL 7035,<br />

self-extinguishing, similar to UL 94 V-0<br />

2 1 Filter mat, 350 g/m 3 quality class EU 2<br />

3 1 Fan<br />

4 1 Connection (terminal block)<br />

5 1 Capacitor<br />

FLA 250<br />

KTA45980<br />

Order Information<br />

230 V AC 115 V AC<br />

Description Order no. Order no.<br />

Standard air filtered fan FL 250 60715-071 60715-073<br />

Air filtered fan FL 250 EMC 60715-108 60715-110<br />

Outlet/Inlet filter FLA 250/300 Standard<br />

(Delivery comprises items 1 + 2), 1 piece<br />

60715-091<br />

Outlet/Inlet filter FLA 250/300 EMC<br />

(Delivery comprises items 1 + 2), 1 piece<br />

60715-126<br />

Replacement filter for FL 250 / 300 / FLA 250 / 300,<br />

(Delivery comprises item 2), 3 pieces<br />

60715-096<br />

KTA46385<br />

Technical data of the fan<br />

Voltage in V 230 115<br />

Frequency in Hz 50 / 60 50 / 60<br />

Air capacity with filter (free blowing ) in m 3 /h 131 131<br />

Combination FL + FLA in m 3 /h 95 95<br />

Noise level per fan in dB (A) 55 55<br />

Max. stat. pressure in PA 57 57<br />

Max. ambient temperature in °C -10...+50 -10...+50<br />

Power consumption in W 18 20<br />

Filter efficiency in % 83 83<br />

Note<br />

EMC version, assembly cut-out 2 mm larger (height, width)<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

2.20<br />

UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> <strong>control</strong> – Air filtered fan<br />

FL 300<br />

Air filtered fan FL 300<br />

Air filtered fan<br />

Simple conversion from pressure to suction mode<br />

EMC design<br />

Type of protection IP54<br />

Delivery comprises (completely assembled)<br />

Item Qty Description<br />

1 1 Front grille and case, Plastic ABS, RAL 7035,<br />

self-extinguishing, similar to UL 94 V-0<br />

2 1 Filter mat, 350 g/m 3 quality class EU 2<br />

3 1 Fan<br />

4 1 Connection (terminal block)<br />

5 1 Capacitor<br />

FLA 300<br />

KTA45980<br />

Order Information<br />

230 V AC 115 V AC<br />

Description Order no. Order no.<br />

Standard air filtered fan FL 300 60715-075 60715-077<br />

Air filtered fan FL 300 EMC 60715-112 60715-114<br />

Outlet/Inlet filter FLA 250/300 Standard<br />

(Delivery comprises items 1 + 2), 1 piece<br />

60715-091<br />

Outlet/Inlet filter FLA 250/300 EMC<br />

(Delivery comprises items 1 + 2), 1 piece<br />

60715-126<br />

Replacement filter for FL 250 / 300 / FLA 250 / 300,<br />

(Delivery comprises item 2), 3 pieces<br />

60715-096<br />

KTA46385<br />

Technical data of the fan<br />

Voltage in V 230 115<br />

Frequency in Hz 50 / 60 50 / 60<br />

Air capacity with filter (free blowing ) in m 3 /h 249 249<br />

Combination FL + FLA in m 3 /h 210 210<br />

Noise level per fan in dB (A) 55 55<br />

Max. stat. pressure in PA 89 89<br />

Max. ambient temperature in °C -10...+50 -10...+50<br />

Power consumption in W 18 20<br />

Filter efficiency in % 83 83<br />

Note<br />

EMC version, assembly cut-out 2 mm larger (height, width)<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.21


<strong>Climate</strong> <strong>control</strong> – Air filtered fan<br />

FL 500<br />

Air filtered fan FL 500<br />

Air filtered fan<br />

EMC design<br />

Type of protection IP54<br />

Available on request, can be converted at the factory from<br />

pressure to suction mode<br />

FLA 500<br />

KTA45981<br />

Delivery comprises (completely assembled)<br />

Item Qty Description<br />

1 1 Front grille and case, Plastic ABS, RAL 7035,<br />

self-extinguishing, similar to UL 94 V-0<br />

2 1 Filter mat, 350 g/m 3 quality class EU 2<br />

3 1 Fan<br />

4 1 Connection (terminal block)<br />

5 1 Capacitor<br />

Order Information<br />

230 V AC 115 V AC<br />

Description Order no. Order no.<br />

Standard air filtered fan FL 500 60715-079 60715-081<br />

Air filtered fan FL 500 EMC 60715-116 60715-118<br />

Outlet/Inlet filter FLA 500/600 Standard<br />

(Delivery comprises items 1 + 2), 1 piece<br />

60715-093<br />

Outlet/Inlet filter FLA 500/600 EMC<br />

(Delivery comprises items 1 + 2), 1 piece<br />

60715-128<br />

Replacement filter for FL 500/600 FLA 500/600,<br />

(Delivery comprises item 2), 3 pieces<br />

60715-097<br />

KTA46386<br />

Technical data of the fan<br />

Voltage in V 230 115<br />

Frequency in Hz 50 / 60 50 / 60<br />

Air capacity with filter (free blowing ) in m 3 /h 461 461<br />

Combination FL + FLA in m 3 /h 350 350<br />

Noise level per fan in dB (A) 69 69<br />

Max. stat. pressure in PA 205 205<br />

Max. ambient temperature in °C -10...+50 -10...+50<br />

Power consumption in W 56 56<br />

Filter efficiency in % 83 83<br />

Note<br />

EMC version, assembly cut-out 2 mm larger (height, width)<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

2.22<br />

UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> <strong>control</strong> – Air filtered fan<br />

FL 600<br />

Air filtered fan FL 600<br />

Air filtered fan<br />

EMC design<br />

Type of protection IP54<br />

Available on request, can be converted at the factory from<br />

pressure to suction mode<br />

FLA 600<br />

KTA45981<br />

Delivery comprises (completely assembled)<br />

Item Qty Description<br />

1 1 Front grille and case, Plastic ABS, RAL 7035,<br />

self-extinguishing, similar to UL 94 V-0<br />

2 1 Filter mat, 350 g/m 3 quality class EU 2<br />

3 1 Fan<br />

4 1 Connection (terminal block)<br />

5 1 Capacitor<br />

Order Information<br />

230 V AC 115 V AC<br />

Description Order no. Order no.<br />

Standard air filtered fan FL 600 60715-083 60715-085<br />

Air filtered fan FL 600 EMC 60715-120 60715-122<br />

Outlet/Inlet filter FLA 500/600 Standard<br />

(Delivery comprises items 1 + 2), 1 piece<br />

60715-093<br />

Outlet/Inlet filter FLA 500/600 EMC<br />

(Delivery comprises items 1 + 2), 1 piece<br />

60715-128<br />

Replacement filter for FL 500/600 FLA 500/600,<br />

(Delivery comprises item 2), 3 pieces<br />

60715-097<br />

KTA46386<br />

Technical data of the fan<br />

Voltage in V 230 115<br />

Frequency in Hz 50 / 60 50 / 60<br />

Air capacity with filter (free blowing ) in m 3 /h 625 625<br />

Combination FL + FLA in m 3 /h 450 450<br />

Noise level per fan in dB (A) 71 71<br />

Max. stat. pressure in PA 225 225<br />

Max. ambient temperature in °C -10...+50 -10...+50<br />

Power consumption in W 155 155<br />

Filter efficiency in % 83 83<br />

Note<br />

EMC version, assembly cut-out 2 mm larger (height, width)<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.23


Overview ................. 0<br />

<strong>Climate</strong> <strong>control</strong> – Heat exchanger<br />

Cabinets.................. 1<br />

<strong>Climate</strong> Control....... 2<br />

Cases ...................... 3<br />

Subracks/<br />

19" chassis............. 4<br />

Modules .................. 5<br />

00902001<br />

Systems .................. 6<br />

Power supply<br />

units........................ 7<br />

Backplanes ............. 8<br />

Accessories ............ 9<br />

Appendix............... 10<br />

On the Internet further important information can be found<br />

under www.schroff.biz<br />

Ordering data<br />

Specifications about power dissipation<br />

Individual configuration, Download of drawings<br />

Modifications, customized solutions<br />

2.24 UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> <strong>control</strong> – Heat exchanger<br />

Overview ............ 2.24<br />

Efficient heat dissipation for indoor and outdoor enclosures<br />

Low weight<br />

Compact dimensions<br />

Cooling devices with integrated evaporation of condensation water<br />

Heat exchanger<br />

Heat exchanger<br />

Indoor application<br />

Standard heat exchanger 230 V and 115 V<br />

Outdoor application<br />

For further information see www.schroff.biz<br />

01102013<br />

Cooling Units<br />

Cooling Units<br />

Indoor application<br />

Standard cooling devices 400 W to 2600 W<br />

Outdoor application<br />

For further information see www.schroff.biz<br />

00902001<br />

Micro<strong>control</strong>ler<br />

Micro<strong>control</strong>ler<br />

For <strong>control</strong> and supervision<br />

Diagnostic messages<br />

Potential free alarm outputs<br />

For further information see www.schroff.biz<br />

00902002<br />

W<br />

Selection Guide<br />

Selection Guide<br />

˚C<br />

KT6741<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.25


<strong>Climate</strong> <strong>control</strong> – Accessories<br />

Heaters 20W up to 150W<br />

Accessories<br />

Simple and fast assembly with clip-on attachment<br />

Press-on terminal connection saves time on assembly<br />

Temperature-limiting<br />

Delivery comprises (fully assembled)<br />

01102004<br />

Item Qty Description<br />

1 1 Heater element, (PTC resistance)<br />

self-regulating voltage range 110-250 V AC/DC<br />

2 Heating body, anodised aluminium extrusion<br />

Assembly: clip for 35 mm rail EN 50022<br />

3 Connections for type HKG = lead 300 mm long 2 core<br />

0.75 mm 2<br />

Connections for type HG = Terminal block for<br />

3 x 0.5 - 0.25 mm 2 wire<br />

Order Information<br />

HGK 20 W HGK 30 W HG 45 W HG 75 W HG 100 W HG 150 W<br />

Description Order no. Order no. Order no. Order no. Order no. Order no.<br />

Heaters 20 W up to 150 W 60715-019 60715-020 60715-021 60715-022 60715-023 60715-030<br />

Support rail for heaters, 1 piece 20715-001<br />

Technical data<br />

Type HGK HGK HG HG HG HG<br />

Heater output in W 20 30 45 75 100 150<br />

Surface temperature in °C approx. 90 approx. 100 approx. 105 approx. 120 approx. 130 approx.140<br />

Current at switch-on approx. in A 1 1.5 1 1.8 2.4 4<br />

Type of protection IP 54 IP 54 IP 20 IP 20 IP 20 IP 20<br />

Class of protection II II I I I I<br />

Dimensions H × B × T in mm 60 × 50 × 25 70 × 50 × 25 65 × 70 × 25 140 × 70 × 25 140 × 70 × 25 220 × 70 × 25<br />

Weight in kg 0.11 0.12 0.3 0.5 0.5 0.8<br />

Test symbols VDE, CE VDE, CE CE CE CE CE<br />

For further information www.schroff.biz/oneClick<br />

z/oneClick<br />

oneClick code = Order no.<br />

2.26<br />

UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> <strong>control</strong> – Accessories<br />

Heater 400 W<br />

Accessories<br />

With temperature <strong>control</strong><br />

Simple and fast assembly with clip-on attachment<br />

Fan freely selectable<br />

Delivery comprises (fully assembled)<br />

01197004<br />

Item Qty Description<br />

1 1 Heater element, high-performance cartridge<br />

2 1 Heating body, anodised aluminium extrusion<br />

Assembly: Clip for 35 mm rail EN 50022<br />

3 1 Terminal connection<br />

4 1 Assembly kit for fan<br />

Order Information<br />

115 V AC 230 V AC<br />

Description Order no. Order no.<br />

Heater 400 W 60715-028 60715-029<br />

Support rail for heaters, 1 piece 20715-001<br />

Protective grille optionally for fan, 1 piece 60197-019<br />

Technical data<br />

Voltage range 115 V AC 230 V<br />

Heater output in W 400 400<br />

Current at switch-on approx. in A 3.5 1.8<br />

Surface temperature with fan in °C approx.140<br />

Type of protection IP 20<br />

Class of protection<br />

I, with GND/earthing<br />

Dimensions:<br />

22 × 120 × 160<br />

Width x Height x Depth in mm<br />

Weight in kg 0.4<br />

Assembly Clip for 35 mm DIN rail EN 50022<br />

Note<br />

Only operate heater in conjunction with fan, danger of<br />

overheating<br />

Single fan (119 mm × 119 mm), see page 2.29<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.27


<strong>Climate</strong> <strong>control</strong> – Accessories<br />

Heater 350/500 W with thermostat and<br />

fan<br />

Accessories<br />

Simple and fast assembly with clip-on attachment<br />

3-pin connecting terminal, separated connection heater/fan<br />

Thermostat from 0 ... 60 °C<br />

Delivery comprises (fully assembled)<br />

Item Qty Description<br />

1 1 Plastic housing, polycarbonate<br />

(RAL 9002, grey-white), clip for 35 mm rail EN 50022<br />

2 1 Heater element, ( PTC resistance), self-regulating<br />

3 1 Fans<br />

Order Information<br />

01197005<br />

Type Weight 115 V AC 230 V AC<br />

kg Order no. Order no.<br />

Heater 350 W 0.9 60715-015 60715-017<br />

Heater 500 W 1.1 60715-016 60715-018<br />

Support rail for heaters, 1 piece 20715-001<br />

Technical data<br />

Voltage range 115 V AC 230 V<br />

Heater output in W 350 550 350 550<br />

Air capacity axial fan m 3 /h 35 45 35 45<br />

Air exit temperature 50 mm<br />

above protective grille in °C<br />

Current at switch-on approx.<br />

in A<br />

Heater element<br />

approx.<br />

150<br />

approx.<br />

160<br />

approx.<br />

150<br />

10.5 12 7 8.5<br />

Resistor (PTC) self-regulating<br />

Connection 3-pin connecting terminal, 2.5 mm 2 ,<br />

separated connection heating/fan<br />

Thermostat Adjustment range 0 ... 60 °C<br />

Control system (<strong>control</strong> Glow lamp<br />

lamp)<br />

Temperature <strong>control</strong> in the event of fan failure<br />

Type of protection IP 00<br />

Class of protection II<br />

Dimensions: height x width x 165 x 100 x 124<br />

depth mm<br />

approx.<br />

160<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

2.28<br />

UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> <strong>control</strong> – Accessories<br />

AC fans / replacement fans<br />

Accessories<br />

Delivery comprises (Individual part)<br />

Item Qty Description<br />

1 1 Fans (width 119 mm, depth 119 mm)<br />

Order Information<br />

Connecting lead<br />

KTA44844<br />

Height<br />

Air capacity<br />

50 Hz, DC<br />

Power consumption<br />

50 Hz<br />

115 V AC 230 V AC<br />

Order no. Order no.<br />

mm m³/h W<br />

25 84 8 20713-146 20713-142<br />

25 108 14 20713-147 20700-001<br />

38 162 15 20713-244 20713-243<br />

Connecting lead PVC (2 x 0.75 mm²), 1 m long with 2 faston<br />

connectors 2.8 x 0.8 mm, 1 piece<br />

21101-246<br />

Protective grille bolt-on fibreglass reinforced plastic (PA),<br />

black, complies with UL 94 V-0 requirements, 1 piece<br />

60225-053<br />

Protective grille clip-in fibreglass reinforced plastic (PA),<br />

black, complies with UL 94 V-0 requirements, 1 piece<br />

60225-052<br />

Bolt-on protective grille<br />

KTA43091<br />

Technical data AC fans<br />

Dimensions 25 × 119 × 119 25 × 119 × 119 38 × 119 × 119<br />

H×W×D<br />

in mm<br />

Frequency in Hz 50 60 50 60 50 60<br />

Air capacity in 84 90 108 120 162 192<br />

m 3 /h<br />

Noise level per 29 30 34 38 37 41<br />

fan in dB (A)<br />

Max. stat. 23 21 41 41 73 88<br />

pressure in PA<br />

Max. ambient 70 70 70 70 70 70<br />

temperature in<br />

°C<br />

Power<br />

8 7 14 11 15 14<br />

consumption in<br />

W<br />

KTA45223<br />

For further information www.schroff.biz/oneClick<br />

z/oneClick<br />

oneClick code = Order no.<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.29


<strong>Climate</strong> <strong>control</strong> – Accessories<br />

DC fans<br />

Accessories<br />

Delivery comprises (Individual part)<br />

Item Qty Description<br />

1 1 Fans height 38 mm (width 119 mm, depth 119 mm)<br />

1a 1 Fans height 25 mm (width 119 mm, depth 119 mm)<br />

with cable for connection, length 55 mm, 2 fast-on<br />

connectors 2.8 x 0.8 mm<br />

Connecting lead<br />

KTA44844<br />

Order Information<br />

Height<br />

Air capacity<br />

50 Hz, DC<br />

Power consumption<br />

50 Hz<br />

Input<br />

voltage<br />

Order no.<br />

mm m³/h W V<br />

25 153 7 24 20713-172<br />

38 184 8 24 20713-240<br />

38 184 8 12 20713-241<br />

38 184 8 48 20713-242<br />

Connecting lead PVC (2 x 0.75 mm²), 1 m long with 2<br />

fast-on connectors 2.8 x 0.8 mm, 1 piece<br />

21101-246<br />

Protective grille bolt-on fibreglass reinforced plastic<br />

(PA), black, complies with UL 94 V-0 requirements, 1 piece<br />

60225-053<br />

Protective grille clip-in fibreglass reinforced plastic (PA),<br />

black, complies with UL 94 V-0 requirements, 1 piece<br />

60225-052<br />

Bolt-on protective grille<br />

KTA43091<br />

KTA45223<br />

Technical data DC fans<br />

Voltage in V DC 24 24 12 48<br />

Dimensions<br />

H × W × D<br />

in mm<br />

Air capacity in<br />

m 3 /h<br />

Noise level per<br />

fan in dB (A)<br />

Max. stat.<br />

pressure in PA<br />

Max. ambient<br />

temperature in<br />

°C<br />

Power<br />

consumption in<br />

W<br />

25 × 119 ×<br />

119<br />

38 × 119 ×<br />

119<br />

38 × 119 ×<br />

119<br />

195 184 184 184<br />

41.5 42 42 42<br />

50.5 68 68 68<br />

70 70 70 70<br />

7 8 8 8<br />

38 × 119 ×<br />

119<br />

Note<br />

Connector lead does not fits with fan 25 mm hight<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

2.30<br />

UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> <strong>control</strong> – Accessories<br />

Speed <strong>control</strong> for fans<br />

Accessories<br />

Speed <strong>control</strong> for 19" fan, 19" blower unit or top cover fan tray<br />

The airflow volume is set depending on:<br />

the ambient temperature<br />

the current energy loss<br />

the actual air resistances<br />

the desired cabinet inner temperature<br />

This has the following advantages:<br />

Functional reliability due to constant cabinet inner temperature<br />

Low noise<br />

01195001<br />

Delivery comprises (assembled)<br />

Item Qty Description<br />

1 1 Speed <strong>control</strong>, see technical data<br />

2 1 Temperature sensor NTC resistor, cable length 1.5 m<br />

3 1 Fan cable, cable length 1.5 m with fast-on connectors<br />

6.3 × 0.8 mm<br />

4 1 Mains cable, cable length 3 m, end isolation stripped<br />

with end sleeves<br />

5 1 Mounting plate for assembly on cabinet upright<br />

6 1 Spring for mounting on the support rail<br />

Order Information<br />

KTA43494<br />

115 V AC 230 V AC<br />

Type Application Order no. Order no.<br />

Single-phase motor 19" fan, blower unit 10713-522 10713-523<br />

Capacitor motor – 10713-524 10713-525<br />

Technical data<br />

KTA43495<br />

Voltage range 110 ... 120 V 220 ... 240 V<br />

Frequency in Hz 50 ... 60 50 ... 60<br />

Input voltage 90 ... 132 V 187 ... 264 V<br />

max. connection power in W 220<br />

possible mains/line frequency 48...62 Hz<br />

Cabinet temperature in °C Adjustment range: +25...+50<br />

Fan speed in % 30...100<br />

Power lead<br />

3 m, end isolation stripped with end<br />

sleeves<br />

Sensor<br />

External NTC resistor<br />

Sensor connection<br />

Plug-in contact and cable 1.5 m<br />

If sensor fails<br />

Maximum speed<br />

Dimensions:<br />

120 × 65 × 40<br />

Width x Height x Depth in mm<br />

Fan connection<br />

Cable 1.5 m with Faston connectors<br />

6.3 x 0.8 mm<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.31


<strong>Climate</strong> <strong>control</strong> – Accessories<br />

Thermostat with integral temperature sensor<br />

Accessories<br />

For switching heater units or fans<br />

Adjustment range 5 ... 60 °C<br />

Order Information<br />

100 ... 130 V AC 200 ... 250 V AC<br />

Description Order no. Order no.<br />

Thermostat with integral temperature<br />

sensor<br />

20715-007 20715-002<br />

Technical data<br />

01102008<br />

Dimensions Height x Width x Depth 75 × 75 × 25<br />

in mm<br />

Adjustment range 5 ... 60 °C<br />

Switching differential<br />

0.5 K<br />

Contact load<br />

(ohmic Load / inductive load)<br />

Contacts<br />

Assembly<br />

Heat (terminal 1–2) 10 A / 4 A<br />

cool (terminal 1–3) 5 A / 2 A<br />

Changeover contact, 1-pin<br />

Bolt-on, alternatively with clip-on<br />

attachment for support rail<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

Thermostat with external temperature sensor<br />

Accessories<br />

External sensor can be positioned near the critical assembly<br />

Adjustment range 20 ... 60 °C<br />

Order Information<br />

Description<br />

Order no.<br />

Voltage range: 90 ... 260 V AC 20715-003<br />

Technical data<br />

01102007<br />

Dimensions Height x Width x Depth 93 × 68 × 44<br />

in mm<br />

Adjustment range 20 ... 60 °C<br />

Switching differential<br />

10 K<br />

Contact load<br />

24 A/10 A<br />

(ohmic load / inductive load)<br />

Contacts<br />

Changeover contact, 1-pin<br />

Assembly<br />

bolt-on<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

2.32<br />

UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> <strong>control</strong> – Accessories<br />

Thermostat with digital display<br />

Accessories<br />

For rack-mounting and panel-mounting<br />

Display changeable from °C to °F<br />

Programmable (secured against unauthorised operation)<br />

Switching differential of 0 ... 10 K freely selectable<br />

3-digit, red display<br />

Order Information<br />

Description<br />

Order no.<br />

Thermostat with digital display 60715-132<br />

Front panel RAL 7035 light grey with cut-out for the<br />

thermostat<br />

30118-315<br />

Front panel anodised with cut-out for the thermostat 30118-267<br />

Front panel 1 U<br />

01197001<br />

SZA45550<br />

Technical data<br />

Operating voltage 115 / 230 V AC (90 ... 260 V AC )<br />

Power consumption in W approx. 3.5<br />

Dimensions Height x Width x Depth 35 × 76 × 59<br />

mm<br />

Assembly cut-out 28.8 × 70.5<br />

Adjustment range in °C -50...+100<br />

Switching differential<br />

0 ... 10 K selectable<br />

Data retention in the event of power Non-volatile memory<br />

failure<br />

Contact load<br />

8 A/3 A<br />

(ohmic Load / inductive load)<br />

Input/sensor<br />

PTC sensor,<br />

-55...+120 °C, cable length 3 m<br />

Contacts<br />

Relay, changeover contact, 1-pin<br />

Type of protection, from(front) IP 54<br />

Connection Screw clamps 2.5 mm 2<br />

Assembly<br />

Mounting with clamping bracket<br />

Assembly<br />

Bolt-on<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.33


<strong>Climate</strong> <strong>control</strong> – Accessories<br />

Hygrostat<br />

Accessories<br />

The hygrostat is used to <strong>control</strong> heating systems to raise the<br />

dewpoint from critical relative air humidity of 65%. -This<br />

prevents condensation and corrosion on components.<br />

Order Information<br />

Description<br />

Order no.<br />

Hygrostat 60715-041<br />

Support rail incl. assembly parts 21101-421<br />

01102006<br />

Technical data<br />

Dimensions Height x Width x Depth 75 × 75 × 25<br />

in mm<br />

Adjustment range of relative air 35 ... 100<br />

humidity in %<br />

Switching differential in % approx. 4<br />

Contact load AC: 24 - 230 V 5 A/0.2 A<br />

(ohmic load / inductive load)<br />

Contact load DC:<br />

max. 60 Watt<br />

Contacts<br />

Changeover contact, 1-pin<br />

Assembly<br />

Bolt-on, alternatively with clip-on<br />

attachment for support rail<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

Inlet IEC<br />

Accessories<br />

For the connection of fans<br />

Bolted housing made of heat-resistant plastic (UL 94 V-0).<br />

10 A / 250 V AC , class of protection I<br />

Order Information<br />

Description<br />

Order no.<br />

Inlet IEC 60715-046<br />

KTA45246<br />

For further information www.schroff.biz/oneClick<br />

oneClick code = Order no.<br />

2.34<br />

UK 08/2003<br />

For further information ... www.schroff.biz


<strong>Climate</strong> <strong>control</strong> – Accessories<br />

For further information ... www.schroff.biz<br />

UK 08/2003<br />

2.35