Two <strong>Wet</strong> <strong>We<strong>at</strong>her</strong> Oper<strong>at</strong>ing Modes<br />

Step feed is the normal oper<strong>at</strong>ing mode<br />

RAS<br />

1 2 3 4 5 6 7<br />

65% 35%<br />

To <strong>Secondary</strong><br />

Clarifiers<br />

RAS<br />

1 2 3 4<br />

5<br />

6<br />

7<br />

To <strong>Secondary</strong><br />

Clarifiers<br />

Aerobic RAS Storage<br />

Primary Effluent<br />

Pipe Bridge<br />

Anaerobic<br />

Anaerobic/aerobic swing<br />

Aerobic<br />

<strong>Wet</strong> we<strong>at</strong>her maximum month tre<strong>at</strong>ment capacity = 98 mgd<br />

with 40% clarifier der<strong>at</strong>ing factor<br />