Clarifier <strong>Capacity</strong> Analysis Based on Historical D<strong>at</strong>a<br />
March 2010 Rain Event Allowed Historical Stress Testing<br />
7.0<br />
6.0<br />
15 3/27/2010 3/28/2010 3/29/2010 3/30/2010 3/31/2010 4/1/2010<br />
3/27/2010 SVI = 205 mL/g<br />
3/28/2010 SVI = 202 mL/g<br />
3/29/2010 SVI = 213 mL/g<br />
Blanket Depth (ft)<br />
5.0<br />
4.0<br />
3.0<br />
2.0<br />
Solids flux analysis - the clarifiers failed <strong>at</strong> a<br />
point 40% less than the theoretical capacity<br />
1.0<br />
0.0<br />
0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 20.0<br />
Clarifier SLR (ppd/sf)<br />
35