<strong>anesthesia</strong> <strong>guide</strong><br />

How to Select Anesthesia Equipment<br />

Respiration<br />

The <strong>anesthesia</strong> machine you select is dependent on<br />

a couple of parameters. Ask yourself the following<br />

questions:<br />

• How many animals are you working with<br />

• What species you are working with<br />

• Do you want a mobile system or table top system<br />

Multiple Animal Systems<br />

We only offer one system that is suitable for<br />

simultaneous multiple animal <strong>anesthesia</strong> delivery. It<br />

is our Multi-Station Research Anesthesia System.<br />

There are 3 models available for either 2, 4 or 6<br />

animals delivery. see page F33 for complete details.<br />

Single Animal Systems<br />

We offer a variety of single animal <strong>anesthesia</strong><br />

machines. We offer both non-rebreathing and<br />

rebreathing systems. Each type is available in either<br />

a mobile or table top model, see below.<br />

Non-Rebreathing vs. Rebreathing Systems<br />

If you are working with animals under 4.5 kg (10 lbs)<br />

you can use a non-rebreathing system. If you are<br />

working with animals over 4.5 kg (10 lbs) you will<br />

need a rebreathing system.<br />

A non-rebreathing system takes the exhaled gas and<br />

directs it to a scavenging system. This system<br />

removes any leftover anesthetic agent from the gas<br />

so it is safe to release to the environment. Smaller<br />

animals have smaller respiratory capacities and<br />

therefore very little anesthetic agent is wasted.<br />

On the other hand, larger animals breathe larger<br />

volumes of gas and require more anesthetic agent. The<br />

advantage of a rebreathing system is that it takes the<br />

exhaled gas from the animal and recirculates it. A<br />

device scrubs the waste CO 2 from the gas and redirects<br />

the cleaned gas back to the inhalation circuit. This<br />

permits the system to reclaim the exhaled anesthetic<br />

agent and recirculate it to the animal. This recirculation<br />

process substantially reduces the amount of anesthetic<br />

agent used during the procedure.<br />

<strong>anesthesia</strong> <strong>guide</strong><br />

Non-Rebreathing Systems<br />

These systems are for use with animals 4.5 kg (10 lbs) or less. You can<br />

select from a variety of <strong>anesthesia</strong> machines. They are listed below and<br />

are classified as suitable for mobile use or for table top use only. Please<br />

note that the CDS 9000, Anesthesia Machines may also be used for<br />

non-rebreathing applications, but they are less economical if you only<br />

need a non-rebreathing system. They are listed under the Rebreathing<br />

Systems to the right.<br />

Order # Product<br />

Mobile Non-Rebreathing<br />

PY2 72-3007 Vaporstick Single O 2 Flowmeter (0.2 to 4 LPM),<br />

see page F32<br />

PY2 72-3009 Vaporstick O 2 and N 2O Flowmeters and Failsafe<br />

(0.2 to 4 LPM), see page F32<br />

Table Top Non-Rebreathing<br />

PY2 72-3011 Table Top Anesthesia Machine with Single O 2<br />

Flowmeter (0.2 to 4 LPM), see page F32<br />

PY2 72-3012 Table Top Anesthesia Machine with Single O 2<br />

Flowmeter (0 to 1000 cc), see page F32<br />

PY2 72-3013 Table Top Anesthesia Machine with Dual O 2 Flowmeter<br />

(0.2 to 4 LPM and 0 to 1000 cc), see page F32<br />

PY2 72-3014 Table Top Anesthesia Machine with Single O 2 and N 2O<br />

Flowmeters and Failsafe (0.2 to 4 LPM), see page F32<br />

Rebreathing Systems<br />

We offer three <strong>anesthesia</strong> machines that are suitable for a rebreathing<br />

system. These systems are for use with animals 4.5 kg (10 lbs) or more.<br />

All may be easily converted to a non-rebreathing system. Please call our<br />

technical support staff for assistance with this procedure.<br />

Order # Product<br />

Mobile Rebreathing<br />

PY2 72-7992 CDS 9000 Single O 2 Flowmeter (0.2 to 4 LPM),<br />

see page F31<br />

PY2 72-7993 CDS 9000 with Dual O 2 Flowmeters (0.2 to 4 LPM),<br />

see page F31<br />

PY2 72-7994 CDS 9000 with Dual O 2 and N 2O Flowmeters and<br />

Failsafe (0.2 to 4 LPM), see page F31<br />

Table Top Rebreathing<br />

PY2 72-6081 CDS 9000 Table Top Anesthesia Machine with<br />

Single O 2 Flowmeter (0.2 to 4 LPM), see page F31<br />

PY2 72-6082 CDS 9000 Table Top Anesthesia Machine with Dual O 2<br />

Flowmeter (0.2 to 4 LPM and 0 to 1000 cc), see page F31<br />

PY2 72-6083 CDS 9000 Table Top Anesthesia Machine with Single O 2<br />

and N 2O Flowmeters and Failsafe(0.2 to 4 LPM),<br />

see page F31<br />

F24<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com


<strong>anesthesia</strong> <strong>guide</strong><br />

How to Select Anesthesia Equipment<br />

Evacuation System Selection Guide<br />

Evacuation Systems are necessary when waste gas from the animal still contains anesthetic agents. It must<br />

be removed from the exhausted gas before it can be released into the environment. What kind of evacuation<br />

systems are available for waste <strong>anesthesia</strong> gas Harvard Apparatus has several options to choose from. Select<br />

the system that best suits your application.<br />

F/Air Evacuation Pure-Guard Lab Animal AES Active Gas<br />

System Fluovac System Monitor System Evacuation System Evacuation System<br />

Canister Style Canister Style Canister Style Charcoal Cartridge Passive Flow System<br />

Evacuation System Evacuation System Evacuation System<br />

Each canister can be used for For use with a single For use with a single Can be used with up to For use with a single<br />

1 <strong>anesthesia</strong> machine, multiple <strong>anesthesia</strong> machine <strong>anesthesia</strong> machine 6 <strong>anesthesia</strong> machines <strong>anesthesia</strong> machine<br />

canisters for multiple machines<br />

Each canister can remove Each canister can remove 70 grams 1 lb No limitation on amount<br />

50 grams of pure 200 grams of halogenated of anesthetic agent<br />

halogenated anesthetic gases anesthetic gases<br />

Passively scavenges waste Actively scavenges waste Passively scavenges waste Actively or passively Active flow collects gas<br />

scavenges waste<br />

from <strong>anesthesia</strong> machine<br />

Does not require Does not require Does not require Maybe be vented directly Must be vented to a<br />

venting to a hood venting to a hood venting to a hood to room when using charcoal fume hood or outside<br />

cartridge or to a hood if desired. charcoal filtration<br />

Easy disposal in Easy disposal in Easy disposal in Charcoal may be disposed Two standard inlet port<br />

regular trash regular trash regular trash of in regular trash and on exhaust port hook<br />

up to existing equipment<br />

Canister is System Requires Fluosorber Canisters Requires Enviro-Pure Canisters Requires charcoal refill cartridges No cartridges required<br />

see page F34 see page F46 see page F35 see page F33 see page F34<br />

for complete details for complete details for complete details for complete details for complete details<br />

<strong>anesthesia</strong> <strong>guide</strong> Respiration<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />

F25


<strong>anesthesia</strong> <strong>guide</strong><br />

Evacuation System Selection Guide (continued)<br />

Evacuation System Selection Guide<br />

Harvard Apparatus offers five basic evacuation/scavenging systems that work with our <strong>anesthesia</strong> setups. A brief description of these systems<br />

and their components are listed below. Three of the systems have multiple configurations based on your <strong>anesthesia</strong> setup. The basic<br />

components are the same, just connections and adapters change with each configuration.<br />

F/Air Evacuation<br />

This evacuation system is a simple<br />

and economical way of removing<br />

anesthetic gases. The active<br />

charcoal in the canister removes<br />

the waste gas. The used canister<br />

can be tossed in the trash for<br />

disposal. See page F34 for<br />

complete details.<br />

Fluovac System<br />

The Fluovac Systems actively<br />

scavenges anesthetic waste and<br />

does not require venting to a<br />

hood. It uses the Fluosorber<br />

Canisters, which when full, can be<br />

disposed of in the regular trash.<br />

See page F46 for complete details.<br />

Respiration<br />

<strong>anesthesia</strong> <strong>guide</strong><br />

Configuration Components Order #<br />

1-A F/Air Canisters, case of 8 PY2 72-1294<br />

Tubing Connector PY2 60-5251<br />

Rodent Circuit Set PY2 72-3026<br />

Respiratory Adaptor PY2 72-2889<br />

1-B F/Air Canisters, case of 8 PY2 72-1294<br />

Tubing Connector PY2 60-5251<br />

Active Gas Evacuation<br />

This evacuation system removes<br />

the waste gas from the <strong>anesthesia</strong><br />

circuit and vents it to a waste<br />

system, ventilation hood or the<br />

outdoors. See page F34 for<br />

complete details.<br />

Configuration Components Order #<br />

3-A Fluovac System 110V (230V) PY2 34-0388/<br />

PY2 34-0387<br />

Fluosorber Canisters PY2 34-0415<br />

Pure-Guard Monitor<br />

System<br />

The Pure-Guard System is similar<br />

to the F-Air Canister Systems, but<br />

it removes all the guess work. The<br />

system monitors the status of the<br />

charcoal canister and alarms you<br />

when it requires changing. See<br />

page F35 for complete details.<br />

Configuration Components Order #<br />

2-A AES Active Gas Evacuation PY2 72-3065<br />

Tubing PY2 72-3093<br />

Male Adaptor, 19 mm PY2 72-3085<br />

Rodent Circuit Set PY2 72-3026<br />

Respiratory Adaptor PY2 72-2889<br />

2-B AES Active Gas Evacuation PY2 72-3065<br />

Tubing PY2 72-3093<br />

Male Adaptor, 19 mm PY2 72-3085<br />

2-C AES Active Gas Evacuation PY2 72-3065<br />

Tubing PY2 72-3093<br />

Configuration Components Order #<br />

4-A Pure-Guard Monitor System PY2 72-8119<br />

Rodent Circuit Set PY2 72-3026<br />

Respiratory Adaptor PY2 72-2889<br />

4-B Pure-Guard Monitor System PY2 72-8119<br />

Lab Animal Evacuation<br />

System<br />

This evacuation system is suitable<br />

for evacuating waste anesthetic<br />

gases from 1 to 6 stations. It was<br />

designed for those facilities to do<br />

not have built-in evacuation systems<br />

or fume hoods. See page F33 for<br />

complete details.<br />

Configuration Components Order #<br />

5-A Lab Animal Evacuation System PY2 72-3066<br />

Charcoal Refill PY2 72-3067<br />

F26<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com


<strong>anesthesia</strong> <strong>guide</strong><br />

How to Select Anesthesia Equipment (continued)<br />

Classic T3<br />

Vaporizers<br />

PY2 60-5244 Manifold<br />

with 8 Ports<br />

Vaporizer Selection Guide<br />

Vaporizers are designed to work with a specific anesthetic agent. Select<br />

the vaporizer based on the agent you will be using in your laboratory.<br />

We offer vaporizers for Isoflurane and Sevoflurane, see page F36 for<br />

complete product offering. Please note that vaporizer endcaps are included<br />

with the <strong>anesthesia</strong> machine NOT the vaporizer. Therefore, if you are<br />

ordering a vaporizer ONLY you will need to order endcaps separately<br />

(1 x PY2 72-3043 and 1 x PY2 72-3044).<br />

Specifications<br />

Inlet Flow<br />

Compensation<br />

Temperature Range<br />

Compensation<br />

Calibration<br />

Accuracy<br />

Duration of Use<br />

Liquid Capacity<br />

Dimensions (H x W x D):<br />

Funnel Fill<br />

Key Fill<br />

Weight:<br />

Funnel Fill<br />

Key Fill<br />

T3<br />

50 mls to 10 liters/min with minimal change<br />

in output concentration<br />

59ºF to 95ºF (15ºC to 35ºC)<br />

69.8ºF (21ºC)<br />

± 15% (within above flow and temperature range)<br />

approximately 1.0 ml of liquid anesthetic is required<br />

to provide 200 ml of vapor<br />

125 ml liquid capacity, with 35 mls absorbed by wick<br />

7.25 in x 5 in x 5.5 in<br />

7.25 in x 5 in x 6 in<br />

16 lbs (7.27 kg)<br />

16 lbs (7.27 kg)<br />

Why Use an Anesthetic Manifold<br />

Manifolds allow the use of both an anesthetizing box and a mask. It<br />

permits the research to direct the flow of gas to where they need it. The<br />

anesthetizing box can be used to initially anesthetize the animal and then<br />

the mask can maintain the anesthetized state during procedures. One side<br />

of the manifold directs the fresh gas to the animal, while the other directs<br />

the waste gas collection.<br />

Harvard Apparatus does not suggest using manifolds to anesthetize<br />

multiple animals simultaneously. PLEASE NOTE, with a manifold, the<br />

amount of agent flowing into each port cannot be controlled – for<br />

individual control to multiple animals, see the Multi-Station Research<br />

System on page F33 of this catalog.<br />

Order # Product<br />

PY2 60-5242 4 Port Manifold – connects to 2 Anesthetic devices<br />

PY2 60-5243 6 Port Manifold – connects to 3 Anesthetic devices<br />

PY2 60-5244 8 Port Manifold – connects to 4 Anesthetic devices<br />

<strong>anesthesia</strong> <strong>guide</strong> Respiration<br />

Order #<br />

PY2 72-8132<br />

PY2 72-7995<br />

PY2 72-7997<br />

PY2 72-7996<br />

Product<br />

T3 Isoflurane Funnel-Fill Vaporizer*<br />

T3 Sevoflurane Funnel-Fill Vaporizer*<br />

T3 Isoflurane Key-Fill Vaporizer*<br />

T3 Sevoflurane Key-Fill Vaporizer*<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />

F27


<strong>anesthesia</strong> <strong>guide</strong><br />

Anesthesia System Selection Guide<br />

Anesthesia System Selection Guide<br />

Harvard Apparatus offers a wide range of Anesthesia configurations to meet most <strong>anesthesia</strong> needs.<br />

Summarized below are some of the systems available. Select from freestanding and table top <strong>anesthesia</strong><br />

machines. Each type is available with a variety of methods for connecting the <strong>anesthesia</strong> circuit to the animal.<br />

With each type of system there is also a variety of evacuation systems available. These evacuations systems<br />

are described in summary format with all of the required components on pages F25 and F26.<br />

Respiration<br />

<strong>anesthesia</strong> <strong>guide</strong><br />

Vaporstick System with Manifold –<br />

Connecting to a Box and a Mask<br />

Components Order #<br />

Vaporstick Anesthesia<br />

PY2 72-3007 for O 2 Only<br />

Machine<br />

PY2 72-3009 for O 2 and N 2O<br />

Vaporizer<br />

Depends on desired agent<br />

Manifold PY2 60-5242<br />

Anesthetizing Box<br />

PY2 50-0108 Small<br />

or PY2 50-0116 Large<br />

Supply Line Adaptor PY2 72-6000<br />

3/16” ID Tubing PY2 72-1024<br />

Options for Evacuation: (see pages F25 and F26)<br />

System<br />

Configuration<br />

F/Air Evacuation<br />

AES Active Gas Evacuation<br />

Fluovac System<br />

Pure-Guard Monitor System<br />

1A<br />

2A<br />

3A<br />

4A<br />

Table Top System with Manifold –<br />

Connecting to a Box and a Mask<br />

Components Order #<br />

Basic Table Top PY2 72-3011, PY2 72-3012,<br />

Anesthesia Machine<br />

or PY2 72-3013 for O 2 Only<br />

PY2 72-3014 for O 2/N 2O<br />

Vaporizer<br />

Depends on desired agent<br />

Manifold PY2 60-5242<br />

Anesthetizing Box<br />

PY2 50-0108 Small or<br />

PY2 50-0116 Large<br />

3/16” ID Tubing PY2 72-1024<br />

Options for Evacuation: (see pages F25 and F26)<br />

System<br />

Configuration<br />

F/Air Evacuation<br />

AES Active Gas Evacuation<br />

Fluovac System<br />

Pure-Guard Monitor System<br />

1A<br />

2A<br />

3A<br />

4A<br />

Vaporstick System with Mask Only<br />

Components Order #<br />

Vaporstick Anesthesia<br />

Machine<br />

Vaporizer<br />

Supply Line Adaptor PY2 72-6000<br />

PY2 72-3007 for O 2 Only<br />

PY2 72-3009 for O 2 and N 2O<br />

Depends on desired agent<br />

3/16” ID Tubing PY2 72-1024<br />

Options for Evacuation: (see pages F25 and F26)<br />

System<br />

F/Air Evacuation<br />

AES Active Gas Evacuation<br />

Fluovac System<br />

Pure-Guard Monitor System<br />

Configuration<br />

1A<br />

2A<br />

3A<br />

4A<br />

Table Top System with Mask Only<br />

Components Order #<br />

Basic Table Top PY2 72-3011, PY2 72-3012,<br />

Anesthesia Machine<br />

or PY2 72-3013 for O 2 Only<br />

PY2 72-3014 for O 2/N 2O<br />

Vaporizer<br />

Depends on desired agent<br />

3/16” ID Tubing PY2 72-1024<br />

Options for Evacuation: (see pages F25 and F26)<br />

System<br />

Configuration<br />

F/Air Evacuation<br />

AES Active Gas Evacuation<br />

Fluovac System<br />

Pure-Guard Monitor System<br />

1A<br />

2A<br />

3A<br />

4A<br />

F28<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com


<strong>anesthesia</strong> <strong>guide</strong><br />

Anesthesia System Selection Guide (continued)<br />

Vaporstick System with Induction<br />

Chamber Only<br />

Components Order #<br />

Vaporstick Anesthesia<br />

Machine<br />

Vaporizer<br />

PY2 72-3007 for O 2 Only<br />

PY2 72-3009 for O 2 and N 2O<br />

Depends on desired agent<br />

Supply Line Adaptor PY2 72-6000<br />

Anesthetizing Box<br />

PY2 50-0108 Small or<br />

PY2 50-0116 Large<br />

3/16” ID Tubing PY2 72-1024<br />

Options for Evacuation: (see pages F25 and F26)<br />

System<br />

Configuration<br />

F/Air Evacuation<br />

AES Active Gas Evacuation<br />

Fluovac System<br />

Pure-Guard Monitor System<br />

1B<br />

B<br />

3A<br />

4B<br />

Table Top System with Induction<br />

Chamber Only<br />

Components Order #<br />

Basic Table Top PY2 72-3011, PY2 72-3012,<br />

Anesthesia Machine<br />

or PY2 72-3013 for O 2 Only<br />

PY2 72-3014 for O 2/N 2O<br />

Vaporizer<br />

Depends on desired agent<br />

Supply Line Adaptor PY2 72-6000<br />

Anesthetizing Box<br />

PY2 50-0108 Small or<br />

PY2 50-0116 Large<br />

3/16” ID Tubing PY2 72-1024<br />

Options for Evacuation: (see pages F25 and F26)<br />

System<br />

Configuration<br />

F/Air Evacuation<br />

AES Active Gas Evacuation<br />

Fluovac System<br />

Pure-Guard Monitor System<br />

1B<br />

2B<br />

3A<br />

4B<br />

Vaporstick System with Ventilator<br />

Components Order #<br />

Vaporstick Anesthesia<br />

Machine<br />

Vaporizer<br />

Ventilator<br />

PY2 72-3007 for O 2 Only<br />

PY2 72-3009 for O 2 and N 2O<br />

Depends on desired agent<br />

PY2 55-0000 Small Animal<br />

Model 683 Ventilator<br />

PY2 55-7058 Inspira Advanced<br />

Safety Ventilator – Volume<br />

Controlled<br />

PY2 55-7059 Inspira Advanced<br />

Safety Ventilator – Pressure<br />

Controlled<br />

PY2 73-0043/PY2 73-0044<br />

Mini Vent Mouse Ventilator<br />

Intubation/Tracheal Cannula Dependent on the weight range<br />

of animal being ventilated*<br />

Supply Line Adaptor PY2 72-6000<br />

If using 683 or Inspira Ventilators – you will also need:<br />

Connection Kit PY2 73-3076<br />

3/16” ID tubing PY2 72-1024<br />

If using the 687, MicroVent, MiniVent or MidiVent Ventilators – you will<br />

also need:<br />

Connection Kit PY2 73-3077<br />

Options for Evacuation: (see pages F25 and F26)<br />

System<br />

Configuration<br />

F/Air Evacuation<br />

1B<br />

AES Active Gas Evacuation 2C<br />

Fluovac System<br />

3A<br />

Pure-Guard Monitor System 4B<br />

* Note: Additional tubing may be necessary to connect to ventilator depending on size cannula<br />

selected. Please refer to Cannula Selection Chart on page F21.<br />

<strong>anesthesia</strong> <strong>guide</strong> Respiration<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />

F29


<strong>anesthesia</strong> <strong>guide</strong><br />

Anesthesia System Selection Guide (continued)<br />

Respiration<br />

<strong>anesthesia</strong> <strong>guide</strong><br />

Table Top System with Ventilator<br />

Components Order #<br />

Basic Table Top PY2 72-3011, PY2 72-3012,<br />

Anesthesia Machine<br />

or PY2 72-3013 for O 2 Only<br />

PY2 72-3014 for O 2/N 2O<br />

Vaporizer<br />

Depends on desired agent<br />

Ventilator<br />

PY2 55-0000 Small Animal<br />

Model 683 Ventilator<br />

Intubation/Tracheal Cannula<br />

PY2 55-7058 Inspira Advanced<br />

Safety Ventilator – Volume<br />

Controlled<br />

PY2 55-7059 Inspira Advanced<br />

Safety Ventilator – Pressure<br />

Controlled<br />

PY2 73-0043/PY2 73-0044<br />

Mini Vent Mouse Ventilator<br />

Dependent on the weight range<br />

of animal being ventilated*<br />

If using 683 or Inspira Ventilators – you will also need<br />

Connection Kit PY2 73-3076<br />

3/16” ID tubing PY2 72-1024<br />

If using the 687, MicroVent, MiniVent or MidiVent Ventilators – you will<br />

also need<br />

Connection Kit PY2 73-3077<br />

Options for Evacuation: (see pages F25 and F26)<br />

System<br />

Configuration<br />

F/Air Evacuation<br />

1B<br />

AES Active Gas Evacuation 2C<br />

Fluovac System<br />

3A<br />

Pure-Guard Monitor System 4B<br />

* Note: Additional tubing may be necessary to connect to ventilator depending on size cannula<br />

selected. Please refer to Cannula Selection Chart on page F21.<br />

Multi-Station Systems<br />

Components Order #<br />

Multi-Station<br />

Anesthesia Machine<br />

Vaporizer<br />

PY2 72-3023 Lab Animal<br />

2-Station System<br />

PY2 72-3024 Lab Animal<br />

4-Station System<br />

PY2 72-3025 Lab Animal<br />

6-Station System<br />

Depends on desired agent<br />

Options for Evacuation: (see pages F25 and F26)<br />

System<br />

Configuration<br />

F/Air Evacuation<br />

1B<br />

Lab Animal Evacuation<br />

5A<br />

Multi-Station Systems include Rodent Circuit Sets (circuit, mask, and uncut diaphragm) for all<br />

stations so they do not need to be ordered separately.<br />

“Thanks so much for the quote and all your technical<br />

advice. You folks at Harvard are so helpful, making<br />

my life much easier! It’s much appreciated.”<br />

F30<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com


<strong>anesthesia</strong> equipment<br />

CDS 9000<br />

Small Animal Anesthesia Machine<br />

Common features of the small animal <strong>anesthesia</strong> machine include a pop-off<br />

valve designed to interface with an active waste gas evacuation system and<br />

maintain a passively full rebreathing bag; a non-rebreathing outlet port; and<br />

200 ml to four liter O 2 flowmeter. It has an easy, quick change absorber canister.<br />

Unit has flexibility to accommodate changing clinical practices with optional<br />

kits to convert from a tabletop unit to a pole mount or wall mount unit.<br />

• Universal anodized aluminum block with built in<br />

inhalation/exhalation valves<br />

• Powder coated for quick and easy cleaning<br />

• Pop-off valve maintains a passive breath in the<br />

rebreathing bag for ease of use<br />

• Fresh gas port<br />

• 200 ml to 4 liter O 2 flowmeter<br />

• Easy, quick change absorber canister<br />

• Two built-in handles for ease of mobility<br />

• Adaptable to all styles of vaporizers<br />

• Optional monitor bracket<br />

• Unit allows for flexibility to accommodate the<br />

changing research practices with optional kits to<br />

convert from a tabletop unit to a pole mount or to<br />

a wall mount unit<br />

• Great performance<br />

• Easy to service and maintain<br />

• Five year warranty<br />

Specifications<br />

Performance Characteristics:<br />

Absorber Canister<br />

Pop-Off Valve<br />

Inhalation/Exhalation Valves<br />

Flowmeter:<br />

Single<br />

Dual<br />

Flush Valve<br />

Pressure Manometer<br />

Gas Inlet(s)<br />

Vaporizer Connection<br />

Environmental:<br />

Operating Temperature<br />

Storage Temperature<br />

Dimensions & Weight:<br />

Pole Mount (H x W x D)<br />

Tabletop (H x W x D)<br />

900 cc<br />

19 mm, relieves at 2 cm H2O<br />

Tapered, 22 mm<br />

0.2 to 4 LPM<br />

0-1000 ml, 0.2 to 4 LPM<br />

10-15 LPM<br />

0-60 cm H2O, 0-30 cm H2O vacuum<br />

DISS male for all gases<br />

Tapered, 23 mm<br />

60°F to 90°F (15°C to 32°C)<br />

30°F to 120°F (-1°C to 48°C)<br />

53.25 in x 26 in x 26 in<br />

(135.3 cm x 66 cm x 66 cm), 10.4 kg (23 lbs)<br />

14.5 in x 14.25 in x 10.5 in<br />

(36.8 cm x 36.2 cm x 26.7 cm), 6.8 kg (15 lbs)<br />

Daily Pressure Test Recommended<br />

Calibration<br />

These Anesthesia Machine are supplied complete with the following:<br />

F-circuit with two liter bag<br />

Modified Jackson Rees with 1/2 liter bag<br />

Sodasorb ® CO2 Absorbent refill bag (2.2 lbs)<br />

Pop-Off Occlusion Valve<br />

Operation Manual<br />

Order # Product<br />

PY2 72-7992 CDS 9000 Pole Mount Anesthesia Machine with Single<br />

Flowmeter 0.2 to 4 LPM<br />

PY2 72-7993 CDS 9000 Pole Mount Anesthesia Machine with Dual<br />

Flowmeter 0-1000 ml, 0.2 to 4 LPM<br />

PY2 72-7994 CDS 9000 Pole Mount Anesthesia Machine with N 2O/O 2<br />

Flowmeter 0.2 to 4 LPM<br />

PY2 72-6081 CDS 9000 Tabletop Anesthesia Machine with Single<br />

Flowmeter 0.2 to 4 LPM<br />

PY2 72-6082 CDS 9000 Tabletop Anesthesia Machine with Dual<br />

Flowmeter 0-1000 ml, 0.2 to 4 LPM<br />

PY2 72-6083 CDS 9000 Tabletop Anesthesia Machine with N 2O/O 2<br />

Flowmeter 0.2 to 4 LPM<br />

Optional Conversion Kits & Brackets<br />

PY2 72-6073 Tabletop Kit<br />

PY2 72-6074 Wall Mount Kit<br />

PY2 72-6075 Pole Mount Kit<br />

PY2 72-6076 Monitor Bracket<br />

<strong>anesthesia</strong> equipment Respiration<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />

F31


<strong>anesthesia</strong> equipment<br />

Vaporstick Anesthesia & Basic Table Top Machines<br />

Vaporizer<br />

not included<br />

Vaporstick<br />

Anesthesia Machine<br />

• Economical <strong>anesthesia</strong><br />

delivery system<br />

• Dedicated unit for<br />

non-rebreathing circuits<br />

• Available with optional<br />

universal vaporizer<br />

mounting bracket<br />

• Can be upgraded to a<br />

rebreathing system with<br />

addition of free standing<br />

CO 2 absorber system<br />

PY2 72-3011<br />

Basic Table Top<br />

Anesthesia<br />

Machine<br />

Respiration<br />

<strong>anesthesia</strong> equipment<br />

The Vaporstick is a utility unit<br />

designed to supply oxygen to nonrebreathing<br />

systems, intensive care<br />

units and nebulizers. The flowmeter,<br />

adjusts from 0.2 to 4 LPM for accurate<br />

patient settings. A flush valve is<br />

included for fast immediate oxygen.<br />

The unit is mounted on a stable spider base (5 legs) and a post assembly.<br />

An owner’s manual and modified Jackson Rees non-rebreathing circuit with<br />

1/2 liter bag, PY2 72-3073, see page F41, are included with the <strong>anesthesia</strong><br />

machine. By adding your choice of options, you can customize the<br />

Vaporstick to suit your research <strong>anesthesia</strong> requirements. Z-bracket and<br />

endcaps are included. Vaporizer must be ordered separately.<br />

Order # Product<br />

PY2 72-3007 Vaporstick Anesthesia Machine<br />

PY2 72-3009 Vaporstick with O 2 and N 2O Flowmeters and Failsafe<br />

Optional Accessories<br />

PY2 72-3010 Freestanding CO 2 Absorber System<br />

PY2 72-3018 Single O 2 E-cylinder Regulator and Double Tank Holder,<br />

see page F37<br />

PY2 72-3020 Dual E-Cylinder O 2 Tank Yokes Holder and Regulator<br />

PY2 72-3017 Add-on Mayo Tray<br />

PY2 72-3049 Z-Bracket Universal Vaporizer Mounting Bracket<br />

(Vaporizer not included)<br />

Basic Table Top Anesthesia Machine<br />

• Economical benchtop <strong>anesthesia</strong> system<br />

• Dedicated system for non-rebreathing circuits<br />

• Accepts Series 100 vaporizers<br />

• Can be upgraded to a rebreathing system with the<br />

addition of a freestanding CO 2 absorber system<br />

• Now includes Rodent Circuit Set!<br />

The Basic Table Top Anesthesia Machine is a table top non-rebreathing system<br />

similar to the Vaporstick, see left. The Basic Table Top Anesthesia Machine<br />

is an extremely compact <strong>anesthesia</strong> machine, 8 in x 8 in x 13 in (L x W x H),<br />

making it ideal for locations where space is limited. Four models are available<br />

which differ only by the type of flowmeter supplied.<br />

An owners manual, Rodent Circuit Set and Modified Jackson Rees nonrebreathing<br />

circuit with 1/2 liter bag, PY2 72-3073, page F41, and endcaps<br />

PY2 72-3043 and PY2 72-3044 are included with the <strong>anesthesia</strong> machine.<br />

The optional freestanding CO 2 Absorber System, PY2 72-3010, features the<br />

same board block rebreathing circuit design as the CDS 9000 Table Top unit.<br />

Vaporizer must be ordered separately.<br />

Order #<br />

PY2 72-3011<br />

PY2 72-3012<br />

PY2 72-3013<br />

PY2 72-3014<br />

PY2 72-3010<br />

Product<br />

Table Top Research with 0.2 to 4 LPM O 2 Flowmeter<br />

Table Top Research with 0 to 1000 cc Flowmeter<br />

Table Top Research with Dual O 2 Flow Meters<br />

0.2-4 LPM and 0-1000 cc<br />

Table Top Research with N 2O and O 2 Flowmeter<br />

and Failsafe<br />

Freestanding CO 2 Absorber System<br />

F32<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com


<strong>anesthesia</strong> equipment<br />

Anesthesia and Evacuation Systems<br />

PY2 72-3025<br />

(Vaporizer<br />

not included)<br />

Multi-Station<br />

Research Anesthesia<br />

System<br />

• Anesthesia delivery<br />

system designed<br />

specifically for research<br />

• Multiple, individually<br />

controlled stations in<br />

a single unit<br />

• Unique rodent circuit,<br />

mask and diaphragm<br />

system for safe,<br />

effective anesthetic<br />

agent delivery<br />

• Use with lab animal<br />

evacuation system<br />

The Multi-Station Research Anesthesia System is the latest technology for<br />

rodent and small animal <strong>anesthesia</strong>. The multi-station unit offers a base unit<br />

with multiple stations each individually controlled. The master flowmeter and<br />

auxiliary flowmeters all receive the same gas supply. The master flowmeter<br />

combined with an anesthetic vaporizer, Series T3, see page F36, are used to<br />

set the maximum percentage of anesthetic agent delivered to each station.<br />

Using the auxiliary flowmeters, the percentage of anesthetic agent can be<br />

diluted using the fresh gas supply from the auxiliary flowmeter. Using an<br />

easy-to-follow flow chart, each individual station can deliver a different<br />

percentage of anesthetic agent as needed, without effecting any other station.<br />

The unique rodent circuit, PY2 72-3026 features a coaxial tube used in<br />

conjunction with a mask. By placing the animal’s nose into the mask<br />

diaphragm, it receives the delivered gas/anesthetic agent mixture. Three<br />

different size diaphragms are available. The waste gas exhaled from the<br />

animal and any unused gas delivered by the <strong>anesthesia</strong> machine, is pulled<br />

around the inner cone through the outside hose of the Rodent Circuit. This<br />

waste gas can be removed from the breathing circuit using either in-house<br />

vacuum or the Lab Animal Evacuation system, PY2 72-3066. The unit is a<br />

simple to use, safe and effective anesthetic delivery and evacuation system<br />

designed specifically for laboratory research use.<br />

The Multi-station Research Anesthesia system is available with two (2), four<br />

(4), or six (6) stations. It is supplied with an operational manual, station hoses,<br />

rodent circuits which include, a mask, hose and a medium diaphragm and<br />

endcaps. A vaporizer, see page F36, and evacuation system must be<br />

purchased separately.<br />

An alternative to the Lab Animal Evacuation system is to connect each rodent<br />

circuit exhaust/exhalation line to it’s own F-Air Filter canister, see page F34.<br />

Order # Product<br />

PY2 72-3023 Lab Animal 2 Station Multi-Station Research System,<br />

2 animal<br />

PY2 72-3024 Lab Animal 4 Station Multi-Station Research System,<br />

4 animal<br />

PY2 72-3025 Lab Animal 6 Station Multi-Station Research System,<br />

6 animal<br />

PY2 72-3026 Circuit Set, Rodent, see page F41<br />

PY2 72-3027 Mask, Rodent (no diaphragm)<br />

PY2 72-3028 Rodent Mask Diaphragm Small (7/16 in Diameter)<br />

PY2 72-3029 Rodent Mask Diaphragm Medium (9/16 in Diameter)<br />

PY2 72-3030 Rodent Mask Diaphragm Large (3/4 in Diameter)<br />

<strong>anesthesia</strong> equipment Respiration<br />

PY2 72-3066 Lab Animal<br />

Evacuation System<br />

Lab Animal Evacuation System<br />

The Multi-Station Evacuation System was designed for those facilities that<br />

do not have a built-in evacuation system or a fume hood is not available. The<br />

waste gas from the system may be vented to a 2 inch outside line or pulled<br />

through activated charcoal so that the air can be recirculated in to the room.<br />

When using the filtration system, the activated charcoal must be changed on<br />

a regular basis, to maintain it’s effectiveness. Typically, 8 to 10 hours of<br />

<strong>anesthesia</strong> delivery can be performed for each new supply of charcoal. The lab<br />

evacuation system, will accommodate waste gas supply from 1 to 6 stations.<br />

PY2 72-3026<br />

Rodent Circuit Set<br />

Order # Product<br />

PY2 72-3066 Lab Animal Evacuation System, 110 VAC, 60 Hz<br />

PY2 72-3046 Lab Animal Evacuation System, 220 VAC, 50 Hz<br />

PY2 72-3067 Charcoal Refill<br />

NOTE: When using in-house suction, a scavenger interface valve must be used when operating<br />

more than one station, to reduce the pull of air.<br />

✐<br />

NOTE:<br />

To adapt port to 3/16" tubing,<br />

PY2 72-6000 and PY2 72-8209 are<br />

required–one of each per port to be adapted.<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />

F33


<strong>anesthesia</strong> equipment<br />

AES and F/Air Filter<br />

AES Active Gas<br />

Evacuation<br />

Anesthesia Evacuation Active Gas<br />

Evacuation System (AES)<br />

• Powered unit for safe and effective removal of<br />

anesthetic waste gas<br />

• Can be mounted to <strong>anesthesia</strong> machine pole or<br />

used as a free standing unit<br />

• Two inlet ports allow connection to an induction<br />

chamber and an <strong>anesthesia</strong> machine simultaneously<br />

Respiration<br />

<strong>anesthesia</strong> equipment<br />

Setup Showing AES Mounted to Pole of Anesthesia Machine<br />

Pop-off<br />

Valve<br />

Pop-off<br />

Valve<br />

Active Gas<br />

Evac. System<br />

Setup Showing AES Mounted to Wall<br />

19 mm<br />

Tubing<br />

19 mm<br />

Tubing<br />

1/2 inch<br />

Coupler<br />

Active Gas<br />

Evac. System<br />

1/2 inch<br />

PVC<br />

1/2 inch<br />

PVC<br />

The Anesthetic Evacuation System (AES) will safely and actively remove waste<br />

gas associated with everyday inhalation <strong>anesthesia</strong>. It can be mounted on the<br />

pole of the CDS 9000 or Vaporstick, see pages F31 to F32. It can also be used<br />

as a freestanding unit and simply placed on the benchtop. Two standard 19 mm<br />

(0.75 inch) inlets and one exhaust port allows easy hook-up to existing<br />

equipment. A 12 foot grounded electrical cord and lightweight tubing, allows<br />

for machine maneuverability.<br />

The waste gas from the pop-off valve on most rebreathing <strong>anesthesia</strong> machines<br />

is collected by passive flow to the AES. This allows for safe operation of the<br />

<strong>anesthesia</strong> machine with little or no vacuum exposure. Using a push blower,<br />

the AES actively removes the waste gas from the unit. The blower has the<br />

capacity of moving 12 cubic feet/minute through up to 150 feet of tubing to an<br />

outside vent or fume hood. The on/off switch illuminates a green light when the<br />

unit is activated. The ‘on’ light assures the operator that the unit is functioning.<br />

The Anesthetic Evacuation System includes a 3 inch and a 10 foot length of<br />

19 mm ID hose and a 12.5 mm (0.5 inch) PVC Adapter. Additional lengths of<br />

tubing may be required and are available as an option along with an adapter<br />

to interconnect the 19 mm outlet tubing. An optional outlet line ceiling plate<br />

is available when connection to an outside wall is not convenient. Unit is<br />

14 in. tall, 5 in. in diameter and weighs 5 lbs.<br />

Order #<br />

PY2 72-3064<br />

PY2 72-3065<br />

Accessories<br />

PY2 72-3093<br />

PY2 72-3085<br />

PY2 72-3070<br />

PY2 72-6001<br />

Product<br />

AES Active Gas Evacuation, 110 VAC 60 Hz<br />

AES Active Gas Evacuation, 220 VAC 50 Hz<br />

Tubing 19 mm (0.75 in) ID , 3 m (10 ft) length<br />

Male Adapters 19 x 19 mm<br />

Ceiling Plate Cover<br />

19-22 mm Adapters<br />

F/AIR Filter Canister<br />

• The easy and economical<br />

way to scavenge<br />

anesthetic gases<br />

This filter canister is the sensible<br />

answer for the removal of excess<br />

halogenated gases from the operating<br />

room environment. It can remove<br />

50 grams of pure halogenated<br />

anesthetic gases. It is convenient to<br />

use and does not require a venting<br />

hood. Simply pre-weigh canister noting the starting weight on the side of the<br />

canister. Monitor weight throughout the procedure and discard once canister has<br />

gained 50 grams. Once used, the canister is then simply disposed of in regular<br />

trash. A connector for tubing is sold separately, see below. The canister is<br />

15.2 cm (6 in) high with a diameter of 8.3 cm (3-1/4 in). Weight of active<br />

component is 200 grams.<br />

Order #<br />

Product<br />

PY2 60-0979 F/AIR Filter Canister, pkg. of 1<br />

PY2 72-1294<br />

PY2 60-5251<br />

Case of 8 F/AIR Filter Canisters<br />

Connector for Tubing for F/AIR Filter Canister<br />

F34<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com


<strong>anesthesia</strong> equipment<br />

Pure-Guard System<br />

Pure-Guard System<br />

• Takes the guesswork out of knowing when to<br />

change your charcoal canister. Remember, agent<br />

concentration, flow rates and humidity can<br />

all affect the life of a charcoal canister. The<br />

Pure-Guard System alerts you when to change<br />

your canister and keeps you safe.<br />

• Patented system effectively removes halogenated<br />

agents from isoflurane and sevoflurane<br />

• Unique alarm system protects you and your staff<br />

by alerting you to waste anesthetic gas (WAG)<br />

breakthrough.<br />

• Larger Enviro-Pure canister contains 1/3 more<br />

charcoal than conventional canisters. So it lasts<br />

longer!<br />

• Inaccurate and unreliable recording of time is no<br />

longer necessary.<br />

• Provides a 20-minute window after the monitor<br />

alarm sounds before room air concentration exceeds<br />

NIOSH permissible exposure level of 2 ppm<br />

(10 x 10 x 8 room with no air exchange).<br />

• CE approved<br />

The Pure-Guard System protects lab personnel from dangerous waste<br />

gases anywhere you use it. Easy-to-use and safer than any other charcoal<br />

canister systems on the market, Pure-Guard combines the patented<br />

Enviro-Pure canister with a special monitor and alarm to offer you pure<br />

protection. Pure-Guard takes the guesswork out of when to change your<br />

canister by alerting you when the canister is full. As a result, you get<br />

excellent protection from waste anesthetic gases anywhere in the facility.<br />

Order #<br />

PY2 72-8119<br />

PY2 72-8120<br />

Product<br />

Pure-Guard System (includes 1 monitor and 6 pack of<br />

Enviro-Pure canisters)*<br />

Pure-Guard Monitor<br />

PY2 72-8121 Enviro-Pure Canister, pkg. of 6<br />

PY2 72-8122<br />

PY2 72-8123<br />

PY2 72-8124<br />

*Note: Not for use with halothane<br />

Pure-Guard 1 inch Pole Mount Bracket<br />

Pure-Guard 2 inch Pole Mount Bracket<br />

Pure-Guard Wall Mount Bracket<br />

<strong>anesthesia</strong> equipment Respiration<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />

F35


<strong>anesthesia</strong> equipment<br />

Vaporizers<br />

Classic T3 Anesthetic Vaporizers<br />

Anti-Spill<br />

Device<br />

Key-Fill<br />

Adapter<br />

Vaporizer Endcaps<br />

Vaporizer Manifolds<br />

Respiration<br />

<strong>anesthesia</strong> equipment<br />

• Classic T3 Vaporizers have a 3-year warranty<br />

• Vaporizers available for Isoflurane and Sevoflurane*<br />

• Annual service and vaporizer conversion available<br />

upon request<br />

Harvard Apparatus offers new anesthetic vaporizers. These vaporizers from<br />

the two most popular manufacturers of vaporizers in the world, Cyprane<br />

and Ohmeda (formerly Ohio Medical) come with a full warranty and with<br />

annual maintenance will offer a lifetime of service. Isoflurane and Sevoflurane<br />

specific vaporizers are available. The vaporizer manifold is included with the<br />

vaporizer.<br />

All vaporizers are designed to be unaffected by pressure, temperature and<br />

flow rate to give you accurate levels of agent concentrations. The vaporizer<br />

provides accurate delivery of anesthetic agent in the following ranges:<br />

from 0.25% - 5% in 1/4 increments up to 3% then 1/2 increments up to 5%.<br />

Simply choose the anesthetic agent desired.<br />

Specifications<br />

Inlet Flow<br />

50 mls to 10 liters/min with minimal change<br />

Compensation<br />

in output concentration<br />

Temperature Range 15ºC to 35ºC (59ºF to 95ºF)<br />

Compensation<br />

Calibration<br />

21ºC (69.8ºF)<br />

Accuracy<br />

±15% (within above flow and temperature range)<br />

Duration of Use<br />

approximately 1.0 ml of liquid anesthetic is required<br />

to provide 200 ml of vapor<br />

Liquid Capacity<br />

125 ml liquid capacity, with 35 mls absorbed by wick<br />

Dimensions (H x W x D) & Weight:<br />

Funnel Fill 18.4 cm x 12.7 cm x 14 cm (7.25 in x 5 in x 5.5 in)<br />

7.27 kg (16 lbs)<br />

Key Fill<br />

18.4 cm x 12.7 cm x 15.2 cm (7.25 in x 5 in x 6 in)<br />

7.25 in x 5 in x 6 in 16 lbs<br />

Order # Product<br />

PY2 72-8132 T3 Isoflurane Funnel-Fill Vaporizer*<br />

PY2 72-7995 T3 Sevoflurane Funnel-Fill Vaporizer*<br />

PY2 72-7997 T3 Isoflurane Key-Fill Vaporizer*<br />

PY2 72-7996 T3 Sevoflurane Key-Fill Vaporizer*<br />

Vaporizer Accessories<br />

PY2 72-3051 Filler Adapter for Key-Fill Vaporizer - Isoflurane<br />

PY2 72-3053 Filler Adapter for Key-Fill Vaporizer - Sevoflurane<br />

PY2 72-3054 Anti-Spill Device - Isoflurane<br />

PY2 72-3056 Anti-Spill Device - Sevoflurane<br />

PY2 72-3043 Male Endcap - Outlet<br />

PY2 72-3044 Female Endcap - Inlet<br />

*Note: Vaporizer Endcaps are not included with the Vaporizer. If you are only purchasing a<br />

Vaporizer, you must also purchase the Endcaps.<br />

F36<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com


<strong>anesthesia</strong> equipment<br />

Anesthesia Machine Accessories<br />

PY2 60-5244 Manifold<br />

with 8 Ports<br />

Manifold<br />

These Manifolds permit the flow of gas to multiple anesthetic devices<br />

from only one vaporizer. One side of the Manifold directs the delivery of<br />

fresh gas while the other side directs the waste gas collection. Stopcocks,<br />

available separately, may be added to the circuit for increased control over<br />

the gas flow. Two stopcocks are required for each set of ports.<br />

These manifolds can also be used with the rodent circuit and induction<br />

chamber to initially anesthetize and maintain without disconnecting the<br />

circuit. Requires tubing with ID of 8 mm (0.25 in).<br />

*Not suggested for multiple animals, see lab animal multi-station on page F33.<br />

• Economical - permits more than one breathing<br />

device to be used with one vaporizer<br />

• Available with 4, 6, or 8 ports providing 2, 3, or 4<br />

anesthetic channels<br />

Order # Product<br />

PY2 60-5242 Manifold with 4 Ports for 2 Anesthetic Devices<br />

PY2 60-5243 Manifold with 6 Ports for 3 Anesthetic Devices<br />

PY2 60-5244 Manifold with 8 Ports for 4 Anesthetic Devices<br />

PY2 60-5245 Stopcock for use with Manifolds, pkg. of 2<br />

PY2 72-3104<br />

O2 Regulator with<br />

0-15 L/M Flowmeter<br />

0-3 Liters/Minute<br />

O2 Flow-meter<br />

O2 and N2O<br />

E-Cylinder<br />

Regulator<br />

Manifolds, Regulators,<br />

Flowmeters and<br />

Hoses<br />

Many accessories to connect a gas<br />

source (O 2 or N 2O ) to an <strong>anesthesia</strong><br />

machine are available. Regulators<br />

are specific for type of gas and tank<br />

size (small, E-cylinder or large,<br />

H-cylinder) used. All regulators<br />

terminate in a gas specific male<br />

DISS fitting. E-cylinder regulators<br />

attach to tank using a yoke and can<br />

only be used with E-size tanks with<br />

a post block. Other fittings and<br />

connectors available, call Harvard<br />

Apparatus Tech Support for more info.<br />

PY2 72-3020<br />

See description<br />

below<br />

O2 and N2O<br />

H-Cylinder<br />

Regulator<br />

Order # Product<br />

PY2 72-3099 O 2 Regulator for E-Cylinder (Includes O 2 Hose)<br />

PY2 72-3100 O 2 Regulator for H-Cylinder (O 2 Hose ordered separately)<br />

PY2 72-3103 O 2 Regulator for E-Cylinder with 0 to 15 LPM Flowmeter<br />

(Includes O 2 Hose)<br />

PY2 72-3104 O 2 Regulator for H-Cylinder with 0 to 15 LPM Flowmeter<br />

PY2 72-3102 N 2O Regulator for H-Cylinder<br />

PY2 72-3018 Single O 2 E-Cylinder Regulator & Double Tank Holder<br />

PY2 72-3020 Dual E-Cylinder O 2 Tank Yokes Holder and Regulator<br />

PY2 72-3112 0 to 3 LPM O 2 Flowmeter 2<br />

PY2 72-7458 O 2 Regulator for H-Cylinder with 0 to 3 LPM Flowmeter<br />

PY2 72-3113 0 to 5 LPM O 2 Flowmeter 2<br />

PY2 72-3114 0 to 15 LPM O 2 Flowmeter 2<br />

PY2 72-3115 O 2 Hose, 10 ft 3<br />

PY2 72-3116 O 2 Hose, 15 ft 3<br />

PY2 72-3117 O 2 Hose, 20 ft 3<br />

PY2 72-3118 N 2O Hose, 10 ft 3<br />

PY2 72-3119 N 2O Hose, 15 ft 3<br />

PY2 72-3120 N 2O Hose, 20 ft 3<br />

PY2 72-5810 DISS Female Hose Barb - O 2<br />

<strong>anesthesia</strong> equipment Respiration<br />

PY2 72-5811<br />

DISS Female Hose Barb - N 2O<br />

1. Replacement flowmeters for <strong>anesthesia</strong> machines are available, call for details<br />

2. Flowmeter with Female DISS inlet and Male DISS outlet<br />

3. Connectors on both ends are Female DISS<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />

F37


<strong>anesthesia</strong> equipment<br />

COAX Breathing Device and Respiratory Adapters<br />

PY2 72-7109<br />

Respiratory Adapters<br />

These polypropylene adapters are<br />

used to connect different tubing<br />

sizes together in respiratory circuits.<br />

Respiration<br />

<strong>anesthesia</strong> equipment<br />

PY2 72-7108<br />

COAX Breathing Device<br />

• For rodents, guinea pigs, and birds<br />

• Durable – constructed of Delrin<br />

This COAX breathing device is a precisely machined apparatus which maintains<br />

the surgical plane. The fresh anesthetic gas enters the side port and then<br />

passes to the nose cone. At this point the anesthetic gas is mixed with the<br />

patient’s respiration and then passes out through a ball check valve to the<br />

gas outlet for scavenging. The positive pressure from the oxygen source and<br />

the patient’s respiration lifts the precision ball valve for scavenging. A #10<br />

balloon acts as a diaphragm or breathing bag.<br />

The COAX is available as a free standing unit or mounted to a durable HDPE<br />

procedure table. This table includes metal strips to hold heating pads in place<br />

and points for tie downs. This unit is supplied with face masks (2 rat and<br />

2 mouse), height adjustment collars and 10 ft. of 0.25 in ID tubing. The unit<br />

measures H x W x L, 2 x 40.6 x 31.8 cm (4 x 16 x 12-1/2 in).<br />

Order # Product<br />

PY2 72-7108 Height Adjustable Delrin COAX<br />

PY2 72-7109 Height Adjustable Delrin COAX with Table<br />

Order # Product<br />

PY2 72-2889 Respiratory Adapter, 6 to 22 mm (0.24 to 0.87 in),<br />

pkg. of 10<br />

PY2 72-2890 Respiratory Adapter, 8 to 22 mm (0.31 to 0.87 in),<br />

pkg. of 10<br />

PY2 72-2891 Respiratory Adapter, 10 to 22 mm (0.39 to 0.87 in),<br />

pkg. of 10<br />

PY2 72-2892 Respiratory Adapter, 12 to 22 mm (0.47 to 0.87 in),<br />

pkg. of 10<br />

PY2 72-2893 Respiratory Adapter, 15 to 22 mm (0.59 to 0.87 in),<br />

pkg. of 10<br />

PY2 72-2894 Respiratory Adapter, 18 to 22 mm (0.71 to 0.87 in),<br />

pkg. of 10<br />

Anesthetizing Box<br />

• For <strong>anesthesia</strong> induction<br />

• Transparent walls<br />

• All joints are carefully<br />

cemented<br />

• Nylon inlet and outlet<br />

on the opposite walls<br />

• Magnetic rubber for<br />

sealing and closing cover<br />

The Panlab thick transparent Perspex Anesthetizing Box allows for constant<br />

observation of the animal while anesthetizing, which helps protect against<br />

accidental overdosing.<br />

Two models are available: one for small rodents, another for medium<br />

animals (rabbit, cats).<br />

Specifications<br />

Material Composition<br />

Dimensions:<br />

for Rats<br />

for Rabbits<br />

Inlet/Outlet External Diameter<br />

Perspex<br />

24 x 15 x 15 cm (9.5 x 5.9 x 5.9 in)<br />

40 x 29 x 29 cm (15.7 x 11.4 x 11.4 in)<br />

8 mm (0.3 in)<br />

Order #<br />

PY2 76-0004<br />

PY2 76-0005<br />

Product<br />

Air Tight Anesthetizing Box for Rats<br />

Air Tight Anesthetizing Box for Rabbits<br />

F38<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com


induction chambers<br />

Induction Chamber, Anesthetizing Boxes and<br />

Backdraft Anesthesia Table<br />

PY2 60-5246 Induction Chamber<br />

Induction Chamber<br />

• Clear acrylic for easy<br />

animal observation<br />

• Two sizes<br />

• Ideal for small animals<br />

• Stainless steel false<br />

bottom for easy<br />

cleaning<br />

This cylindrical acrylate chamber is<br />

ideal for anesthetizing small animals<br />

such as rodents, guinea pigs, and<br />

birds. It has two, 1/4 inch barbed hose<br />

fittings, one for gas delivery and one for gas scavenging. The gas delivery<br />

barb directs the flow of anesthetic gas towards the bottom of the chamber.<br />

The chamber has a routed top that ensures a perfect fit. There are no<br />

corners so cleaning is easy. Includes 10 ft of 0.25 in ID tubing.<br />

Dimensions<br />

Inner, H x Dia<br />

Small<br />

Large<br />

Overall, H x Dia<br />

Small<br />

Large<br />

Barbs<br />

Order #<br />

PY2 72-7110<br />

PY2 60-5246<br />

Product<br />

20.3 x 20.3 cm (8 x 8 in)<br />

8.89 x 13.3 cm (3.5 x 5.25 in)<br />

20.3 x 20.3 cm (8 x 8 in)<br />

30.5 x 27.9 cm (12 x 11 in)<br />

17.8 x 17.8 cm (7 x 7 in)<br />

30.5 x 27.9 cm (12 x 11 in)<br />

Accepts, ID x OD, 6 x 8 mm<br />

(1/8 x 1/4 in) tubing<br />

Induction Chamber, Small<br />

Induction Chamber, Large<br />

PY2 50-0116<br />

PY2 50-0108<br />

Anesthetizing Boxes<br />

These anesthetizing boxes are<br />

constructed of 6 mm (1/4 in) thick,<br />

transparent plastic, with all joints<br />

securely cemented. The transparent<br />

plastic allows the animal to be under<br />

constant observation. Two 4.8 mm<br />

(3/16 in) nylon tubing connectors are<br />

cemented on opposite ends of the<br />

box, one at the top and the other at<br />

the bottom, for introducing and<br />

removing the gas.<br />

These boxes are available in two sizes: small and large. The small box is<br />

for rodents. The top slides open lengthwise on machined grooves. The<br />

large box is for larger animals such as rabbits and cats. Its top has three<br />

hinges for easy opening. Two fasteners squeeze the top down against a<br />

rubber gasket to seal the joints.<br />

The small box measures, H x W x D, 10.7 x 25.7 x 11 cm (4 x 10 x 4.5 in).<br />

The large box measures, H x W x D, 29 x 44 x 29 cm (11.5 x 19.5 x 11.5 in).<br />

*Note: Boxes must be cleaned with an acrylic approved cleaner - not alcohol.<br />

Order #<br />

PY2 50-0108<br />

PY2 50-0116<br />

Product<br />

Anesthetizing Box, Small<br />

Anesthetizing Box, Large<br />

induction chambers Respiration<br />

Portable Down<br />

Draft Table<br />

• Pulls anesthetic gases<br />

down and away from<br />

the researchers<br />

• Better access to animals<br />

than conventional<br />

fume hoods<br />

• Superior design and<br />

construction prevent<br />

debris accumulation<br />

Specifications<br />

Total Dimensions:<br />

Tabletop<br />

Work area<br />

Sidewalls<br />

Weight<br />

Material<br />

Airflow<br />

Voltage<br />

Autoclavable<br />

64.8 x 76.2 cm (25.5 x 30 in)<br />

61 x 76.2 cm (24 x 30 in)<br />

43.2 x 61 cm (17 x 24 in)<br />

7.6 cm (3 in) out from perforated tabletop<br />

20.4 kg (45 lbs) for tabletop<br />

10.4 kg (23 lbs) for blower (without filter)<br />

Stainless Steel<br />

90 ft/min average velocity at surface;<br />

50 ft/min average velocity 3” above tabletop surface<br />

110 VAC only<br />

Yes<br />

Our downdraft table provides an effective way to protect workers from<br />

exposure to anesthetics, chemicals, and debris particles. Various filters are<br />

available to provide the safest surgical environment possible.<br />

Tables are available with a single speed blower unit or with accessories to<br />

vent the system outdoors.<br />

Optional accessories include shelving and an anodized aluminum cart.<br />

Order # Product<br />

PY2 72-6201 Portable Down Draft Table with Blower<br />

PY2 72-6202 Portable Down Draft Table with Vent<br />

PY2 72-6205 Aluminum Cart<br />

PY2 72-6206 Potassium Permanganate filters, pkg. of 2<br />

PY2 72-6207 Carbon Filters, pkg. of 2<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />

F39


<strong>anesthesia</strong> accessories<br />

Anesthesia Masks and Inhalation Narcosis Chamber<br />

PY2 59-8202<br />

PY2 59-7977<br />

Large Canine<br />

Ventilation Mask<br />

PY2 59-8201<br />

PY2 59-8203<br />

Respiration<br />

<strong>anesthesia</strong> accessories<br />

Cat Ventilation/Anesthesia Masks<br />

These soft pliable vinyl plastic masks conform to the facial contours of a cat.<br />

They are fitted with a standard 15 mm (3/5 in) taper for connection to<br />

<strong>anesthesia</strong> machines, see pages F31 to F33. They are available in three sizes<br />

and are supplied individually or as a convenient set containing one mask of<br />

each size.<br />

The mask diameters are 25 mm (1 in), 38 mm (1-1/2 in), and 50 mm (2 in) for<br />

the small, medium and large size masks respectively.<br />

Order # Product<br />

PY2 59-8201 Cat Ventilation/Anesthesia Mask, Small<br />

PY2 59-8202 Cat Ventilation/Anesthesia Mask, Medium<br />

PY2 59-8203 Cat Ventilation/Anesthesia Mask, Large<br />

PY2 59-8204 Set of 3 Masks, one of each size<br />

PY2 59-6717 Inhalation Narcosis<br />

Chamber<br />

Inhalation Narcosis<br />

Chamber<br />

• Convenient for<br />

anesthetizing small<br />

animals, such as mice,<br />

hamsters, rats, or<br />

guinea pigs<br />

A clear acrylic hinged cover permits<br />

observation of animals. All other<br />

components are made of polypropylene and are not affected by anesthetic<br />

compounds.<br />

A folding perforated platform is removed to fill the bottom with cotton and<br />

replaced to support the animal. Anesthetic is poured into the small funnel<br />

at the side and runs into the bottom of the chamber where it is absorbed<br />

by cotton. A second stopcock on the other side of the chamber permits the<br />

entrance of fresh air during <strong>anesthesia</strong> to prevent suffocation.<br />

Maximum ID is 197 mm (7-3/4 in); top ID is 178 mm (7 in); height from<br />

platform to top is 127 mm (5 in); height under platform is 57 mm (2-1/4 in);<br />

overall height is 197 mm (7-3/4 in).<br />

Order # Product<br />

PY2 59-6717 Inhalation Narcosis Chamber<br />

Canine Ventilation/Anesthesia Masks<br />

These masks provide a convenient way of providing artificial ventilation or<br />

administration of anesthetic gases to dogs. They are constructed of rugged<br />

transparent polycarbonate. One end has a standard 15 mm (3/5 in) taper for<br />

connection to <strong>anesthesia</strong> tubing, while the other end has a soft flexible<br />

rubber diaphragm that molds itself to the contours of a dog’s snout.<br />

Two sizes are available. The small mask has an unstretched diaphragm<br />

opening of 2.5 cm (1 in), while the large mask has an unstretched opening<br />

of 4.4 cm (1-3/4 in).<br />

Order # Product<br />

PY2 72-8206 Canine Ventilation/Anesthesia Mask, Small<br />

PY2 72-8203 Canine Ventilation/Anesthesia Mask, Large<br />

PY2 72-8207 Replacement Diaphragm for Small Mask<br />

Small Animal<br />

Anesthesia Masks<br />

• For rats, guinea pigs,<br />

birds, and mice<br />

• Simple, yet effective<br />

design<br />

PY2 59-8255<br />

These Anesthesia Masks were<br />

designed with smaller animals in<br />

mind. They have a simple cylindrical<br />

PY2 59-8254<br />

shape with a rubber diaphragm. A<br />

small slit is cut in the diaphragm to<br />

accommodate the animal’s snout or<br />

beak. The opposite end tapers down to a standard press fitting port<br />

measuring 15.3 mm OD x 11.9 mm ID. These Masks can be used with bain<br />

circuits, non-rebreathing systems, or ‘Y’ pieces. Includes 1 diaphragm.<br />

Order # Product<br />

PY2 59-8254 Mouse Anesthesia Mask<br />

PY2 59-8255 Rat, Guinea Pig and Bird Anesthesia Mask<br />

PY2 72-3923 Replacement Diaphragms, pkg. of 10<br />

F40<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com


<strong>anesthesia</strong> accessories<br />

Anesthesia Circuits<br />

PY2 72-3026 Rodent<br />

Circuit Set<br />

PY2 72-3073 Modified<br />

Jackson Rees (MJR)<br />

Non-rebreathing<br />

Anesthesia<br />

Circuit<br />

Rodent Mask and C-Pram Circuit<br />

Modified Jackson Rees (MJR)<br />

Non-Rebreathing Anesthesia Circuit<br />

The Modified Jackson Rees (MJR) is a new design for non-rebreathing.<br />

Unlike the old scavenging units, this system incorporates a relief valve on<br />

the main unit which allows the use of any size bag. This system will adapt<br />

to all <strong>anesthesia</strong> machines and does not require a Bain Block.<br />

Machine End View of Circuit<br />

Rodent Circuit Mask<br />

• Unique circuit designed specifically for rodent<br />

<strong>anesthesia</strong><br />

• Will work with any non-rebreathing <strong>anesthesia</strong><br />

machine<br />

Order #<br />

PY2 72-3073<br />

PY2 72-3075<br />

PY2 72-3043<br />

PY2 72-3074<br />

Product<br />

Modified Jackson Rees (Non-Rebreather) and<br />

1/2 Liter Bag<br />

Avian/Research MJR and 1/4 Liter Bag<br />

Male Endcap (to connect at outlet end of vaporizer)<br />

Add on Non-Rebreather Adapter<br />

<strong>anesthesia</strong> accessories Respiration<br />

Developed in conjunction with leading research facilities, the Rodent Circuit<br />

is the most effective, user-friendly, mask for rodents. Available with 3 different<br />

size diaphragms, the mask easily fits most rodents. With the use of a C-Pram<br />

circuit shown above, the mask is designed to deliver and evacuate the gas<br />

through one tube. Traditionally, the open mask system has caused problems<br />

because of the contamination of waste gas to the staff and the patient<br />

rebreathing CO 2<br />

. These problems are avoided with the Rodent Circuit and mask<br />

design. When combined with in-house suction or the Lab Animal Evacuation<br />

System or F/Air canister, see page F34, there is minimal risk of untoward<br />

anesthetic agent exposure for the researcher. Inlet tubing: 6.25 mm (0.25 in)<br />

ID, silicone tubing. Outlet from rodent circuit is a 22 mm (0.866 in) respiratory<br />

fitting. Respiratory Adapters are available to connect the rodent circuit outlet<br />

to tubing of various sizes from 6 to 15 mm ID, see page F38.<br />

Order # Product<br />

PY2 72-3026 Circuit Set, Rodent (hose, mask and uncut<br />

diaphragm)<br />

PY2 72-3027 Mask, Rodent (no diaphragm)<br />

PY2 72-3028 Rodent Mask Diaphragm Small (7/16 in DIA)<br />

PY2 72-3029 Rodent Mask Diaphragm Medium (9/16 in DIA)<br />

PY2 72-3030 Rodent Mask Diaphragm Large (3/4 in) DIA)<br />

PY2 72-3071 Universal F-Circuit<br />

Rebreathing Anesthesia Circuit<br />

Universal Rebreathing Anesthesia F-Circuit<br />

The Universal F-circuit is a rebreathing circuit that can be used on small animals<br />

up to 200 lbs. Rebreathing circuits allow the animal to rebreathe exhaled and<br />

excess vaporized anesthetic agent which have circulated through a CO 2 absorber<br />

system thus reducing the amount of anesthetic agent used. The unique single<br />

limb circuit 1) replaces the need for a traditional adult and pediatric circuit,<br />

2) reduces the clutter around the animal and 3) takes the weight off the end<br />

of the endotracheal tube. The tube within a tube design allows heat and<br />

moisture to be retained in the circuit, which helps to maintain body temperature<br />

and recover the patient more quickly.<br />

Order # Product<br />

PY2 72-3071 40 inch F-Circuit (rebreathing)<br />

PY2 72-3072 60 inch F-Circuit (rebreathing)<br />

PY2 72-3082 F-Circuit Elbow<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />

F41


ims <strong>anesthesia</strong><br />

Anesthetic Workstation and Systems<br />

Respiration<br />

ims <strong>anesthesia</strong><br />

Mobile Anesthetic Post<br />

NEW Mobile Anesthetic Post System<br />

Our new mobile anesthetic post system is a stable wheeled base with a<br />

sturdy support pole. Already fixed to the post is an attachment to mount<br />

your pin index regulator of choice (size E Bottles) Simply select your base<br />

unit and select your small <strong>anesthesia</strong> bracket then your regulator (suitable<br />

for E size bottles). The small anesthetic bracket unit is already manufactured<br />

with all the necessary ports to simply fit to the top of this pole. This<br />

enables our bracket systems to be adapted into a wheeled solution for<br />

ease of use. Simply design your small bracket unit, include your regulator<br />

from the selection below and include the regulator to flowmeter high<br />

pressure hose set and you have a complete system.<br />

Regulators for Post System:<br />

Order #<br />

PY2 34-1060<br />

PY2 34-1257<br />

Product<br />

O 2 Pin index regulator for E size cylinders<br />

Air Pin Index regulator for E size cylinders<br />

Complete<br />

Anesthetic Systems<br />

• Fittings and gauges<br />

for 1 x O 2 and 1 x N 2 O<br />

size E cylinders<br />

•O 2 and N 2 O tapered<br />

veterinary flowmeters<br />

•O 2 flush<br />

• Low O 2 alarm with N 2 O<br />

safety cut out device<br />

• Smooth running<br />

anti-static castors<br />

• Stainless steel shelving<br />

• Stainless steel fittings<br />

and tubing<br />

As well as the modular systems<br />

Complete Anesthetic Systems<br />

already offered in this catalog,<br />

International Marketing Supply now<br />

to offers an “off the shelf” complete <strong>anesthesia</strong> system designed specifically<br />

for the research laboratory.<br />

Specifications<br />

Dimensions:<br />

Over All, H x W x D 1415 x 480 x 720 mm (55.7 x 18.9 x 28.4 in)<br />

Top Shelf, D x W 480 x 400 mm (18.9 x 15.8 in)<br />

Order # Product<br />

PY2 34-0480 Complete Anesthetic System with Halothane<br />

Funnel Fill Vaporizer<br />

PY2 34-0481 Complete Anesthetic System with Halothane<br />

Key Fill Vaporizer<br />

PY2 34-0482 Complete Anesthetic System with Isoflurane<br />

Funnel Fill Vaporizer<br />

PY2 34-0483 Complete Anesthetic System with Isoflurane<br />

Key Fill Vaporizer<br />

High Pressure Tubing Assembly:<br />

Order #<br />

PY2 34-1385<br />

PY2 34-1386<br />

PY2 34-1387<br />

Product<br />

High Pressure Hose from O 2 Regulator to Flowmeter,<br />

includes connectors<br />

High Pressure Hose from N 2O Regulator to Flowmeter,<br />

includes connectors<br />

High Pressure Hose from Air Regulator to Flowmeter,<br />

includes connectors<br />

F42<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com


ims <strong>anesthesia</strong><br />

Anesthesia Bracket Units<br />

PY2 34-0412 PY2 34-1352<br />

Equipment not included<br />

Anesthetic Bracket Units - Create Your<br />

Own System<br />

Our anesthetic bracket systems are easy! Select your base unit, flowmeters,<br />

vaporizer type, and source of gas supply and select the corresponding part<br />

numbers, your bracket will then be completely assembled to your specification<br />

and supplied complete.<br />

Vaporizer Options<br />

Select your vaporizer of choice from the table below, all vaporizers are new<br />

and come with a 3 year warranty and service interval. Each vaporizer is<br />

calibrated specifically to the specified anesthetic drug. Please note if ordering<br />

the Selectatec vaporizer you will additionally need to order the compatability<br />

block (PY2 34-1091).<br />

Equipment not included<br />

Order # Product<br />

Base Unit Options: Large Bracket<br />

PY2 34-1405 Large Bracket System 1-2 gas<br />

PY2 34-1406 Wall mounting System for Large Bracket<br />

PY2 34-0403 Oxygen Flow Meter for Large Bracket<br />

PY2 34-0404 N 2<br />

0 Flow Meter for Large Bracket<br />

PY2 34-1126 Air Flow Meter for Large Bracket<br />

PY2 34-1138 Carbon Dioxide Flow Meter for Large Bracket<br />

PY2 34-1067 Outlet Tube Mount 23mm for Vaporizer<br />

PY2 34-1068 Inlet Tube Mount 23mm for Vaporizer<br />

PY2 34-1264 Oxygen Flush System for Rapid Recovery<br />

Base Unit Options: Small Bracket<br />

PY2 34-1352 Small Bracket 1-2 gas<br />

PY2 34-1404 Wall Mounting System for Small Bracket<br />

PY2 34-1420 Oxygen Flow Meter for Small Bracket 0.2 – 2.0 liter/min<br />

PY2 34-1261 Nitrous Flow Meter for Small Bracket 0.2 – 2.0 liter/min<br />

PY2 34-0781 Air Flow Meter for Small Bracket 0.2 – 2.0 liter/min<br />

PY2 34-1067 Outlet Tube Mount 23mm for Vaporizer<br />

PY2 72-3044 Inlet Tube Mount 23mm for Vaporizer<br />

ims <strong>anesthesia</strong> Respiration<br />

Cage Mount<br />

Anesthetic Agent Vaporizer Select<br />

Isoflurane Pour Fill PY2 34-1040 PY2 34-1259 + PY2 34-1091<br />

Isoflurane Key Fill PY2 34-1041 PY2 34-1172 + PY2 34-1091<br />

Halothane Pour Fill PY2 34-1101 PY2 34-1260 + PY2 34-1091<br />

Halothane Key Fill PY2 34-1102 PY2 34-1213 + PY2 34-1091<br />

Sevoflurane Pour Fill PY2 34-1269 PY2 34-1271 + PY2 34-1091<br />

Sevoflurane Key Fill PY2 34-1270 PY2 34-1272 + PY2 34-1091<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />

F43


ims <strong>anesthesia</strong><br />

NEW Trolley Anesthesia Systems<br />

Harvard Apparatus has developed an extensive range of off the shelf<br />

<strong>anesthesia</strong> trolley systems, suitable for a wide range of applications. These<br />

mobile trolley systems have anti-static castors, stainless steel shelving,<br />

veterinary flowmeters, pin index regulators (suitable for E-size gas bottles).<br />

Specifications<br />

Dimension (H x W x D)<br />

Top Shelf (D x W)<br />

1415 x 480 x 720 mm (55.7 x 18.9 x 28.3 in)<br />

480 x 400 mm (18.9 x 15.8 in)<br />

Complete Pre-Configured Systems<br />

Please refer to the simple selection table below to select your appropriate<br />

trolley system for your requirements. All systems are supplied complete,<br />

and include all regulators, flowmeter(s), vaporizer, tube mounts and are<br />

supplied fully assembled and tested.<br />

Respiration<br />

ims <strong>anesthesia</strong><br />

Complete Pre-Configured Systems<br />

Isoflourane Halothane Key Fill Pour Fill Low O 2 N 2 O<br />

Order # Oxygen N 2 O Vaporizer Vaporizer Vaporizer Vaporizer Alarm cut off<br />

PY2 34-1048 • – • – – • – –<br />

PY2 34-1049 • – – • – • – –<br />

PY2 34-1050 • • • – – • • •<br />

PY2 34-1051 • • – • – • • •<br />

PY2 34-1117 • – • – • – – –<br />

PY2 34-1118 • – – • • – – –<br />

PY2 34-1119 • • • – • – • •<br />

PY2 34-1120 • • – • • – • •<br />

• Included with system<br />

– not included with system<br />

F44<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com


ims <strong>anesthesia</strong><br />

Anesthetic Bracket Unit, Vaporizers<br />

and Tube Mounts<br />

PY2 34-0412<br />

PY2 34-0397<br />

Anesthetic Bracket Unit<br />

An alternative means of mounting the anesthetic components (rather than<br />

using the Anesthetic Workstation), is the IMS Anesthetic Bracket Unit. The<br />

Anesthetic Bracket Unit can either be FREE STANDING on a bench or WALL<br />

MOUNTED, with the fixings supplied. It is drilled ready to accept one<br />

flowmeter (single gas unit) or two flowmeters (two gas unit). Flowmeters<br />

must be ordered separately.<br />

Specifications<br />

Dimensions, H x W x D<br />

460 x 450 x 170mm (18.1 x 17.7 x 6.7 in)<br />

Order # Product<br />

PY2 34-0411 Anesthetic Bracket for Single Gas<br />

PY2 34-0412 Anesthetic Bracket for Two Gases<br />

Equipment not included<br />

Halovet Vaporizer<br />

• Graduated in 0.5% divisions<br />

• For continuous flow “Out of circuit” use<br />

• Single control, locks in “off” position<br />

• Compatible with most types of anesthetic<br />

machines and fittings<br />

• Supplied as 8% version<br />

This unit is a flow and temperature compensated vaporizer. It is supplied<br />

complete with mounting block and screws. Servicing is carried out directly<br />

with the manufacturer.<br />

Order # Product<br />

PY2 34-0397 Halovet Vaporizer, Funnel Fill<br />

PY2 34-0398 Halovet Vaporizer, Key Fill<br />

PY2 34-0401 Key Fill Adapter<br />

ims <strong>anesthesia</strong> Respiration<br />

PY2 34-0399 PY2 34-0400<br />

Halovet Tube Mounts<br />

Order # Product<br />

PY2 34-0399 Halovet Inlet Tube Mount for 22mm Vaporizers<br />

PY2 34-0400 Halovet Outlet Tube Mount for 22mm Vaporizers<br />

PY2 34-1067 Endcap for PY2 34-1246<br />

PY2 34-1068 Outlet Endcap for PY2 34-1246<br />

Anesthetic Key Fill Applicators<br />

To ensure leak free filling of your anesthetic vaporizer select the<br />

applicator suitable for your vaporizer.<br />

Order # Product<br />

PY2 34-0401 Isoflurane Anesthetic Key Fill Applicator<br />

PY2 34-0772 Halothane Anesthetic Key Fill Applicator<br />

PY2 34-1391 Sevoflurane Anesthetic Key Fill Applicator<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />

F45


ims <strong>anesthesia</strong><br />

Fluovac System, IMS Fluosorber<br />

and Accessories<br />

IMS Fluosorber<br />

Fluovac System PY2 34-0415<br />

The Fluosorber consists of a canister<br />

containing activated carbon, which<br />

absorbs anesthetic gas extremely<br />

efficiently.<br />

It is used with the Fluovac to scavenge<br />

anesthetic waste from the working<br />

environment, and is quickly and<br />

simply attached to the Fluovac unit.<br />

The Fluosorber’s capacity to scavenge<br />

is measured by weight: Simply<br />

pre-weigh canister and change once<br />

it has increased 200 grams. During<br />

manufacturing each Fluosorber is tested to ensure an air flow of 60 liters per<br />

minute with a flow resistance not exceeding 2.0 cmH 2O. When exhausted,<br />

the Fluosorber is sealed in the special bags provided and can then be<br />

completely incinerated. Supplied in cases of 6 canisters.<br />

Respiration<br />

ims <strong>anesthesia</strong><br />

Fluovac System<br />

• Absorbs anesthetic vapors from the work area,<br />

protecting personnel from exposure<br />

• Allows optimal access to the animal particularly<br />

important when carrying out close-up or micro<br />

surgery<br />

• A self-contained, portable unit requiring no extra<br />

ducting or ventilation<br />

• Three different size masks available<br />

• Incorporates a special double mask which supplies<br />

the anesthetic and scavenges excess vapors<br />

simultaneously<br />

• Requires minimal maintenance<br />

• Easy to use: simply connect to your vaporizer<br />

system and insert a Fluosorber canister<br />

• Each Fluovac is supplied with a size 1-Double mask<br />

The Fluovac Systems combines small animal <strong>anesthesia</strong> with operator<br />

safety. Fluosorber canisters must be ordered separately, see to the right.<br />

Specifications<br />

Overall Dimensions, 180 x 275 x 300 mm (7.1 x 10.8 x 11.8 in), case only<br />

H x W x D<br />

Weight (inc. Fluosorber) 8 kg (17.6 lbs)<br />

Weight (exc. Fluosorber) 7 kg (15.4 lbs)<br />

Power<br />

240 VAC, 50 Hz; 110 VAC, 60 Hz, 37 Watts<br />

IMPORTANT: The Fluovac must only be used with non-flammable gases<br />

Order # Product<br />

PY2 34-0387 Fluovac, 240 VAC, 50 Hz<br />

PY2 34-0388 Fluovac, 110 VAC, 60 Hz<br />

Specifications<br />

Active Canister Weight<br />

Exhausted Weight<br />

1200 g (2.65 lbs)<br />

1400 g (3.1 lbs)<br />

Order # Product<br />

PY2 34-0415 IMS Fluosorber, 6 canisters<br />

PY2 34-0392<br />

Fluovac Mask<br />

Support<br />

Order # Product<br />

PY2 34-0394 Fluovac Mask Support for Size 1 Mask<br />

PY2 34-0395 Fluovac Mask Support for Size 2 Mask<br />

PY2 34-0396 Fluovac Mask Support for Size 3 Mask<br />

Fluovac Exhaust<br />

Tube Mount<br />

The gas exhaust duct on the rear of<br />

the Fluovac unit can be fitted with<br />

a tube mount to vent exhaust gases<br />

such as nitrous oxide (Note: It is not<br />

necessary to vent if only anesthetic<br />

agent is used as the Fluovac with the Fluosorber canister, removes anesthetic<br />

gas from the atmosphere most effectively). Suitable tube for venting is the<br />

cuffed plastic tubing, see PY2 34-0426 on page F53.<br />

Order # Product<br />

PY2 34-0392 Fluovac Exhaust Tube Mount<br />

Fluovac<br />

Mask Support<br />

Designed to hold a Fluovac mask in<br />

position on a flat surface. This support<br />

minimizes the risk of movement<br />

between the animal and the mask.<br />

F46<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com


Fluovac System<br />

ims <strong>anesthesia</strong><br />

PY2 34-0389 PY2 34-0391<br />

PY2 34-1379<br />

PY2 34-0393<br />

Order # Product<br />

PY2 34-0393 Gas Flow Directors<br />

PY2 34-0459<br />

Fluovac Masks<br />

Harvard Apparatus is pleased to<br />

introduce the new Fluovac Mouse<br />

Mask, a single arm coaxial mask<br />

for the delivery and scavenging of<br />

anesthetic gases utilizing the<br />

Fluovac System.<br />

Order # Product<br />

PY2 34-1379 Fluovac Mask Size 0.5 single arm (mice)<br />

PY2 34-0389 Fluovac Mask Size 1 dual arm (rat)<br />

PY2 34-0390 Fluovac Mask Size 2 single arm (G. Pig)<br />

PY2 34-0391 Fluovac Mask Size 3 single arm (rabbit)<br />

Gas Flow Directors<br />

An effective yet simple method of<br />

eliminating the Connector Set<br />

from the IMS Fluovac system.<br />

Directs the flow of gas to either or<br />

both double rodent mask simply<br />

by turning the knob.<br />

Directavalves<br />

Gas flow can be sent in one of two<br />

directions by simply turning a small<br />

valve on top of the assembly.<br />

Fluovac Isolator<br />

Valve<br />

A most useful addition to our gas<br />

scavenging range, the valve redirects<br />

gas from the FLUOVAC mask when<br />

out of use for short periods. The<br />

advantage is that neither the<br />

Vaporizer setting nor the flowmeter<br />

setting have to be altered when an animal is removed from the mask thus<br />

saving time having to reset the previous settings.<br />

Also, if the gas flow has inadvertently been set a little high then it could<br />

overcome the scavenging action at the mask when an animal is removed - the<br />

use of the valve prevents contamination of the area by stopping the gas<br />

reaching the mask.<br />

The valve is activated by the push/pull control knob to the indicated setting.<br />

In use the gas supply and scavenged gas flow through specially machined<br />

channels in the valve. In the isolation mode the gas flow from the vaporizer<br />

is directed into the scavenged gas flow while simultaneously opening a<br />

channel to outside air which is sucked into the mask by the scavenging effect<br />

thus also clearing traces of anesthetic gas from the mask.<br />

The units are easily fitted into existing masks by the user - full instructions<br />

are included. Please state the size of the mask to be modified as Size 1 has<br />

a smaller bore Crystaflex tube than 2 & 3.<br />

Order # Product<br />

PY2 34-0402 Fluovac Isolator Valve*<br />

*Note: This Valve is a registered design.<br />

Specifications<br />

Internal Diameter<br />

Length<br />

PY2 34-0402<br />

Fluovac Tube<br />

Restrainer<br />

Used for induction of <strong>anesthesia</strong> if<br />

the patient cannot be held at the<br />

Fluovac mask - the Size 1 mask end<br />

is simply plugged into the end of the<br />

unit which is then supplied with<br />

PY2 34-0457<br />

anesthetic gas and is also scavenged.<br />

The patient is kept up to the front of<br />

the tube with a holding bar. When the animal is anesthetized it is taken out<br />

of the tube, the mask is unplugged and the animal is positioned at the<br />

mask–a very quick and easy procedure.<br />

57 mm (2.24 in)<br />

Adjustable up to 200 mm (7.87 in)<br />

ims <strong>anesthesia</strong> Respiration<br />

Order #<br />

PY2 34-0459<br />

Product<br />

Directavalves<br />

Order #<br />

PY2 34-0457<br />

Product<br />

Fluovac Tube Restrainer<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />

F47


ims <strong>anesthesia</strong><br />

Anesthetizing Chambers & Table<br />

Fluovac Anesthetizing<br />

Chamber With Gas<br />

Scavenging System<br />

Respiration<br />

ims <strong>anesthesia</strong><br />

Fluovac Anesthetizing Chamber<br />

with Gas Scavenging System<br />

Further enhance the flexibility of your Fluovac system by the addition of a<br />

special anesthetizing chamber. No modifications to the existing Fluovac<br />

unit are necessary.<br />

The system provides a safe working environment for staff while minimizing<br />

stress to the animal.<br />

The crux of the system is the Directavalve, a valve which can control the flow<br />

of gases and vapors in either of two directions. Two Directavalves are used<br />

in the system. One is placed on the outlet tube mount of the Vaporizer, so that<br />

halothane can be directed to either the Fluovac masks or the anesthetizing<br />

chamber. The other is placed on the Fluosorber canister, so that Fluovac<br />

scavenges from the mask or chamber as required.<br />

The clear Perspex chamber has a 6mm inlet tube mount which enters the<br />

chamber under a false floor. Scavenging is via a tube mount with specially<br />

shaped air bleeds. These create a vortex in the chamber, optimizing the<br />

scavenging effect.<br />

Removal of the animal will cause some vapor to be released: this can be<br />

overcome by placing the chamber in a flow hood.<br />

Please note that there are two sizes available, the smaller designed is<br />

specifically for a single animals.<br />

NEW Portable Scavenged Anesthesia Table<br />

Harvard Apparatus have developed a simple easy to use portable scavenged<br />

anesthetic operating table for mice. Simply connect the anesthetic delivery<br />

tube to your anesthetic supply. Then connect the exhaust mount to your<br />

Fluovac scavenging system (22 mm bore scavenge tubing). This will give you<br />

an inexpensive, portable, down-draft operating table. Tables can also be<br />

created for Rats. Please ask for details.<br />

Order # Product<br />

PY2 34-1411 Scavenged Anesthesia Platform<br />

PY2 34-0909 22mm Bore Tubing to Connect to Fluovac<br />

Gas Scavenging Kit System Components<br />

Order # Product Qty.<br />

PY2 34-0399 Inlet Tube Mount 1<br />

PY2 34-0400 Outlet Tube Mount 1<br />

PY2 34-0422 6 mm Bore PVC Tubing x 1m Long 1<br />

PY2 34-0459 Directa Valves 2<br />

PY2 34-0909 22 mm Bore Tubing x 1m Long 1<br />

Plus Either<br />

PY2 34-0460 Large Anesthetizing Chamber Only 1<br />

or<br />

PY2 34-0462 Small Anesthetizing Chamber Only 1<br />

Order #<br />

PY2 34-0458<br />

PY2 34-0461<br />

Product<br />

Fluovac Anesthetizing Chamber with Gas Scavenging<br />

System, Large<br />

Fluovac Anesthetizing Chamber with Gas Scavenging<br />

System, Small<br />

PY2 34-0460<br />

Specifications<br />

Dimensions, H x W x D:<br />

Large Unit<br />

Small Unit<br />

Anesthetizing<br />

Chamber<br />

These anesthetizing chambers are<br />

available in two sizes. The smaller<br />

size was designed specifically for<br />

use with smaller species.<br />

200 x 200 x 305 mm (7.9 x 17.9 x 12 in)<br />

134 x 128 x 170 mm (5.3 x 5 x 6.7 in)<br />

Order # Product<br />

PY2 34-0460 Anesthetizing Chamber Large<br />

PY2 34-0462 Anesthetizing Chamber Small<br />

PY2 34-0462<br />

F48<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com


ims <strong>anesthesia</strong><br />

Anesthetizing Chambers and Workstations<br />

Scavenged Anesthetizing Chamber<br />

For use in conjunction with the Fluovac. It is easy to use–simply plug a size<br />

one mask into the rear socket, turn on the Fluovac and gas supply.<br />

When the animal(s) are anesthetized the inner chamber slides forward<br />

allowing the gas supply to be diverted and the chamber scavenged. During<br />

this process fresh air is drawn into the inner chamber to help scavenge any<br />

residual anesthetic gas.<br />

The following sizes are the dimensions of the inner chamber only. Please<br />

note that there are two sizes available. The smaller is designed specifically<br />

for use with a single animal.<br />

PY2 34-0455 PY2 34-0456<br />

✐<br />

NOTE:<br />

This system is used when one chamber<br />

is sufficient and use of both Size 1 Masks are<br />

also required. If two chambers are required to<br />

give sufficient output and masks are not required<br />

then the use of the following system is suggested.<br />

Specifications<br />

Dimensions, H x W x D:<br />

Large Unit<br />

Small Unit<br />

110 x 160 x 260 mm (4.3 x 6.3 x 10.2 in)<br />

98 x 106 x 130 mm (3.9 x 4.2 x 5.1 in)<br />

Order # Product<br />

PY2 34-0455 Scavenged Anesthetizing Chamber, Large<br />

PY2 34-0456 Scavenged Anesthetizing Chamber, Small<br />

Custom Built Options<br />

With expertise in design and engineering, Harvard Apparatus Ltd has<br />

manufactured many items to our customer’s specification. Pictured below<br />

is a complete down draft, height adjustable mobile anesthetizing table. It<br />

has built in power supply, gas regulators, flowmeters and isoflourane<br />

vaporizer, high intensity cold light source, simple snap fit anesthetic mask<br />

connections, surgical tray connections and heated surgical board. This was<br />

developed to plug into a customer’s existing scavenging systems. The height<br />

adjustment is made with a hand held remote control and has 10 preset<br />

heights ensuring perfect operating conditions for each user.<br />

If you have a similar requirement please contact us with your requirements.<br />

ims <strong>anesthesia</strong> Respiration<br />

Order #<br />

PY2 34-1133<br />

Product<br />

Special Operating Table Plus Anesthesia<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />

F49


ims <strong>anesthesia</strong><br />

Pneumatic Fittings and CO 2 Chambers<br />

CO 2 Chambers<br />

with Dump Door<br />

An added option for CO 2 Chambers<br />

is to have a dump door fitted. This<br />

enables CO 2 to be cleared from the<br />

chamber without having to tip up<br />

the chamber and waiting, therefore<br />

saving time and effort.<br />

The chamber is easily and quickly opened and closed, and locked in place<br />

by means of a centrally placed knob. The side opening is below the false<br />

floor. Three chambers sizes are available.<br />

Specifications<br />

Dimensions, H x W x D:<br />

Large Chamber 305 x 305 x 455 mm (12 x 12 x 17.9 in)<br />

Medium Chamber 200 x 200 x 200 mm (7.9 x 7.9 x 7.9 in)<br />

Small Chamber 150 x 100 x 255 mm (5.9 x 3.9 x 10 in)<br />

Order # Product<br />

PY2 34-0434 CO 2<br />

Chamber with Dump Door, Large<br />

PY2 34-0435 CO 2<br />

Chamber with Dump Door, Medium<br />

PY2 34-0436 CO 2<br />

Chamber with Dump Door, Small<br />

Pneumatic Fittings<br />

Spares and/or upgrades can be made to existing anesthetic systems by use<br />

of pneumatic quick release fittings.<br />

Respiration<br />

ims <strong>anesthesia</strong><br />

PY2 34-0451 PY2 34-0452<br />

PY2 34-0454 PY2 34-0453<br />

Order #<br />

PY2 34-0451<br />

PY2 34-0452<br />

PY2 34-0453<br />

PY2 34-0454<br />

Product<br />

1/4" UNC Thread, Female Quick Release Fitting for Use<br />

on Chambers etc.<br />

Male Quick Release Fitting with Push in Fitting for<br />

6mm OD Pneumatic Tubing<br />

Coiled 6mm OD Tubing<br />

6mm OD Pneumatic Tubing, Natural Color, sold per meter<br />

Specifications<br />

Dimensions, H x W x D:<br />

Large Chamber<br />

Medium Chamber<br />

Small Chamber<br />

315 x 305 x 455 mm (12.4 x 12 x 17.9 in)<br />

210 x 200 x 305 mm (8.3 x 7.9 x 12 in)<br />

160 x 100 x 255 mm (6.3 x 3.9 x 10 in)<br />

PY2 34-0429 PY2 34-0430<br />

Anesthetic/CO 2<br />

Chambers<br />

These chambers have a 6 mm wall<br />

thickness and can be ordered in<br />

either white or clear Perspex. The<br />

lid is 10 mm thick clear Perspex and<br />

PY2 34-0431<br />

has a foam sealing strip.<br />

Inside, the chamber has a false perforated aluminum floor resting on nylon<br />

supports. Brass straight fittings are supplied as standard. The inlet is below<br />

the grill floor and outlet at top of opposite end.<br />

Three different sized chambers area available.<br />

Product PY2 34-0452 Quick Release Inlet (male fitting) is available<br />

separately. This fitting is for use with coiled pneumatic fitting systems.<br />

Order #<br />

PY2 34-0429<br />

PY2 34-0430<br />

PY2 34-0431<br />

PY2 72-1080<br />

PY2 72-3043<br />

✐<br />

NOTE:<br />

Product<br />

Anesthetic/CO 2<br />

Chamber, Large<br />

Anesthetic/CO 2<br />

Chamber, Medium<br />

Anesthetic/CO 2<br />

Chamber, Small<br />

Silicone Tubing 3/16" ID, 1/4" OD, 25 ft<br />

Male Endcap with Barb for 3/16" to 1/4" ID Tubing<br />

Product PY2 34-0452 Quick Release Inlet<br />

(male fitting) is available separately. This fitting<br />

is for use with coiled pneumatic fitting systems.<br />

F50<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com


ims <strong>anesthesia</strong><br />

Flowmeters, Regulator Valves and Tube Mounts<br />

PY2 34-0404 PY2 34-0407<br />

PY2 34-0437<br />

PY2 34-0447<br />

PY2 34-0438 PY2 34-0439<br />

Veterinary Flowmeters for O 2<br />

and N 2<br />

O<br />

These are tapered, variable area flowmeters, for use with both oxygen and<br />

nitrous oxide. Flow is controlled by a needle valve operated by a simple<br />

control knob mounted on the front of the unit.<br />

Calibration of the oxygen flowmeter is 200cc/minute to 15 LPM, and of the<br />

nitrous oxide flowmeter 100cc/minute to 12 LPM. Tube mounts are included<br />

with each flowmeter.<br />

Low flow rates can be obtained with impressive accuracy. The Flowmeter<br />

Bench Stand is suitable for PY2 34-0403, PY2 34-0404, PY2 34-0405 and<br />

PY2 34-0406.<br />

Order # Product<br />

PY2 34-0403 Oxygen Veterinary Flowmeter<br />

PY2 34-0404 Nitrous Oxide Veterinary Flowmeter<br />

PY2 34-0407 Flowmeter Bench Stand<br />

Oxygen Flowmeter (Linear Scale)<br />

Covers range of 0 to 10LPM. It has a stainless steel needle valve with<br />

150mm tube. Tube mounts are included.<br />

Order # Product<br />

PY2 34-0405 Oxygen Flowmeter, Linear Scale<br />

PY2 34-0407 Flowmeter Bench Stand<br />

Regulator Valves<br />

All include tube mounts, 3/8 inch nut to 1/4 inch stem.<br />

Order # Product<br />

PY2 34-0438 Oxygen: Bull Nose Fitting, 5/8 inch BSP, 2 Gauge,<br />

Single Stage. To Fit Size F Cylinders<br />

PY2 34-0441 Oxygen: Side Entry, Pin Index, 2 Gauge, Single Stage.<br />

To Fit Size E Cylinders<br />

PY2 34-0439 Carbon Dioxide: 2 Gauge, Single Stage.<br />

To Fit Size F Cylinders<br />

PY2 34-0440 Carbon Dioxide: Side Entry, Pin Index. 2 Gauge,<br />

Single Stage. To Fit Size E Cylinders<br />

PY2 34-0437 Nitrous Oxide: 11/16 inch, 20 TPI Fitting. 2 Gauge,<br />

Single Stage. To Fit Size F Cylinders<br />

PY2 34-0442 Carbon Dioxide: Side Entry, Pin Index. 2 Gauge,<br />

Single Stage. To Fit Size E Cylinders<br />

PY2 34-0447 Replacement Washers for pin index regulators are also<br />

available. Metal with a rubber seal<br />

ims <strong>anesthesia</strong> Respiration<br />

PY2 34-0443<br />

Regulator Tube Mounts<br />

Replacements to fit any of the above. 3/8 inch<br />

nut to 1/4 inch stem.<br />

PY2 34-0406<br />

Carbon Dioxide Flowmeter (Linear Scale)<br />

Covers range of 0-12 LPM. Stainless steel needle valve with 150 mm tube.<br />

Again, tube mounts are included.<br />

Order #<br />

PY2 34-0443<br />

Product<br />

Regulator Tube Mounts<br />

Order #<br />

PY2 34-0406<br />

PY2 34-0407<br />

Product<br />

Carbon Dioxide Flowmeter, Linear Scale<br />

Flowmeter Bench Stand<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />

F51


ims <strong>anesthesia</strong><br />

Low Oxygen Warning Alarm,<br />

Oxygen Flush Control and Tubing<br />

PY2 34-0423<br />

PY2 34-0425<br />

PY2 34-0426<br />

PY2 34-0421<br />

PY2 34-0425<br />

PY2 34-0424<br />

Respiration<br />

ims <strong>anesthesia</strong><br />

Low Oxygen Warning Alarm<br />

A low warning device ensuring safety and continuity during <strong>anesthesia</strong><br />

techniques. Simply connects in series between Regulator and Flowmeter and<br />

emits a loud whistle when Oxygen drops to a low level in the Cylinder.<br />

This is activated between 2.5 - 2 bar in a decreasing concentration leaving ample<br />

time for the operator to change the cylinder with the minimum disruption<br />

in procedure.<br />

Order # Product<br />

PY2 34-0473 Low Oxygen Warning Alarm<br />

PY2 34-0420<br />

Order # Product<br />

PY2 34-0420 Neoprene Antistatic Tubing<br />

Neoprene Antistatic<br />

Tubing<br />

Black (with yellow line). It measures<br />

6mm ID x 13mm OD and is supplied<br />

in 1 meter length.<br />

Oxygen Flush Control<br />

Incorporated into a anesthetic unit to supply oxygen directly from source to<br />

the animal, or for emergency use plus an aid to recovery.<br />

Order # Product<br />

PY2 34-0474 Oxygen Flush Control<br />

High Pressure<br />

Tubing<br />

This High Pressure Tubing is black<br />

PY2 34-0423<br />

and measures 6mm ID x 13mm OD.<br />

It is supplied in 1 meter lengths. For use with CO 2<br />

or compressed air.<br />

PY2 34-0421<br />

Order # Product<br />

PY2 34-0421 Silicone Tubing<br />

PY2 34-0422<br />

Silicone Tubing<br />

Used as the inner supply tube<br />

for Fluovac masks. It measures<br />

6mm ID x 10mm OD and is<br />

supplied in 1 meter length.<br />

PVC Tubing<br />

This tubing is available in 2 sizes<br />

and is supplied in 1 meter lengths.<br />

Order #<br />

PY2 34-0423<br />

Product<br />

High Pressure Tubing<br />

Order #<br />

PY2 34-0422<br />

PY2 34-0782<br />

Product<br />

PVC Tubing, 6mm ID x 9mm OD<br />

PVC Tubing, 8mm ID x 11mm OD<br />

F52<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com


ims <strong>anesthesia</strong><br />

Tubing, Replacement Tubing, Y Pieces<br />

and Tube Clamps<br />

Anti-Static High Pressure Tubing<br />

Anti-Static High<br />

Pressure Tubing<br />

This anti-static tubing measures<br />

6 mm ID x 13 mm OD and is<br />

supplied in 1 meter lengths. It is<br />

available in two colors.<br />

PY2 34-0940<br />

Y Pieces<br />

These y-connectors are constructed<br />

of white polypropylene and measure<br />

6.7 mm ID x 9 mm OD. Supplied 10<br />

per package.<br />

Order #<br />

PY2 34-0424<br />

PY2 34-0425<br />

Product<br />

Anti-Static High Pressure Tubing, Oxygen<br />

(White in Color)<br />

Anti-Static High Pressure Tubing, Nitrous Oxide<br />

(Blue in Color)<br />

Order # Product<br />

PY2 34-0940 Y Pieces, pkg. of 10<br />

PY2 34-0426<br />

Order # Product<br />

PY2 34-0426 Plastic Tubing, 22 mm Taper, 10 meters<br />

Corrugated Plastic<br />

Tubing<br />

Corrugated tubing to fit all 22 mm<br />

tapered male tube mounts (including<br />

Directavlaves, Halovets etc.). Supplied<br />

as a continuous 10 meter length,<br />

which can be cut into 38 cm sections<br />

each end having a 22 mm taper.<br />

Order # Product<br />

PY2 34-0941 Tube Clamps, pkg. of 10<br />

Tube Clamps<br />

The Tube Clamps have a knurled<br />

adjuster screw and hinged side<br />

plate. Supplied 10 per package.<br />

ims <strong>anesthesia</strong> Respiration<br />

Fluovac Mask<br />

Replacement<br />

Tubing<br />

Fluovac Mask Replacement Tubing<br />

Order # Product<br />

PY2 34-0427 Fluovac Mask Replacement Tubing, Size 1,<br />

27 mm OD x 1 m long<br />

PY2 34-0428 Fluovac Mask Replacement Tubing, Size 2 & 3,<br />

30 mm OD x 1 m long<br />

Convert from a Gas Bottle<br />

to a Piped Gas Supply<br />

Harvard Apparatus have developed a simple connector to convert any<br />

anesthetic trolley or bracket system with pin index regulator to be able to<br />

receive gas supply from a wall mounted piped gas supply. Simply connect<br />

one end to your wall mounted supply and then insert the specially designed<br />

pin index block into the pin index socket on your regulator. The length of<br />

high pressure hose supplied is 2 m (other sizes and gasses can be custom<br />

made if necessary).<br />

Hose<br />

Order # Supplied Product<br />

PY2 34-1064 2 m (6.6 ft) Hose to Pin Index for Oxygen<br />

PY2 34-1065 2 m (6.6 ft) Hose to Pin Index for Nitrous Oxide<br />

Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />