How to Select Anesthesia Equipment<br />
Respiration<br />
The <strong>anesthesia</strong> machine you select is dependent on<br />
a couple of parameters. Ask yourself the following<br />
questions:<br />
• How many animals are you working with<br />
• What species you are working with<br />
• Do you want a mobile system or table top system<br />
Multiple Animal Systems<br />
We only offer one system that is suitable for<br />
simultaneous multiple animal <strong>anesthesia</strong> delivery. It<br />
is our Multi-Station Research Anesthesia System.<br />
There are 3 models available for either 2, 4 or 6<br />
animals delivery. see page F33 for complete details.<br />
Single Animal Systems<br />
We offer a variety of single animal <strong>anesthesia</strong><br />
machines. We offer both non-rebreathing and<br />
rebreathing systems. Each type is available in either<br />
a mobile or table top model, see below.<br />
Non-Rebreathing vs. Rebreathing Systems<br />
If you are working with animals under 4.5 kg (10 lbs)<br />
you can use a non-rebreathing system. If you are<br />
working with animals over 4.5 kg (10 lbs) you will<br />
need a rebreathing system.<br />
A non-rebreathing system takes the exhaled gas and<br />
directs it to a scavenging system. This system<br />
removes any leftover anesthetic agent from the gas<br />
so it is safe to release to the environment. Smaller<br />
animals have smaller respiratory capacities and<br />
therefore very little anesthetic agent is wasted.<br />
On the other hand, larger animals breathe larger<br />
volumes of gas and require more anesthetic agent. The<br />
advantage of a rebreathing system is that it takes the<br />
exhaled gas from the animal and recirculates it. A<br />
device scrubs the waste CO 2 from the gas and redirects<br />
the cleaned gas back to the inhalation circuit. This<br />
permits the system to reclaim the exhaled anesthetic<br />
agent and recirculate it to the animal. This recirculation<br />
process substantially reduces the amount of anesthetic<br />
agent used during the procedure.<br />
<strong>anesthesia</strong> <strong>guide</strong><br />
Non-Rebreathing Systems<br />
These systems are for use with animals 4.5 kg (10 lbs) or less. You can<br />
select from a variety of <strong>anesthesia</strong> machines. They are listed below and<br />
are classified as suitable for mobile use or for table top use only. Please<br />
note that the CDS 9000, Anesthesia Machines may also be used for<br />
non-rebreathing applications, but they are less economical if you only<br />
need a non-rebreathing system. They are listed under the Rebreathing<br />
Systems to the right.<br />
Order # Product<br />
Mobile Non-Rebreathing<br />
PY2 72-3007 Vaporstick Single O 2 Flowmeter (0.2 to 4 LPM),<br />
see page F32<br />
PY2 72-3009 Vaporstick O 2 and N 2O Flowmeters and Failsafe<br />
(0.2 to 4 LPM), see page F32<br />
Table Top Non-Rebreathing<br />
PY2 72-3011 Table Top Anesthesia Machine with Single O 2<br />
Flowmeter (0.2 to 4 LPM), see page F32<br />
PY2 72-3012 Table Top Anesthesia Machine with Single O 2<br />
Flowmeter (0 to 1000 cc), see page F32<br />
PY2 72-3013 Table Top Anesthesia Machine with Dual O 2 Flowmeter<br />
(0.2 to 4 LPM and 0 to 1000 cc), see page F32<br />
PY2 72-3014 Table Top Anesthesia Machine with Single O 2 and N 2O<br />
Flowmeters and Failsafe (0.2 to 4 LPM), see page F32<br />
Rebreathing Systems<br />
We offer three <strong>anesthesia</strong> machines that are suitable for a rebreathing<br />
system. These systems are for use with animals 4.5 kg (10 lbs) or more.<br />
All may be easily converted to a non-rebreathing system. Please call our<br />
technical support staff for assistance with this procedure.<br />
Order # Product<br />
Mobile Rebreathing<br />
PY2 72-7992 CDS 9000 Single O 2 Flowmeter (0.2 to 4 LPM),<br />
see page F31<br />
PY2 72-7993 CDS 9000 with Dual O 2 Flowmeters (0.2 to 4 LPM),<br />
see page F31<br />
PY2 72-7994 CDS 9000 with Dual O 2 and N 2O Flowmeters and<br />
Failsafe (0.2 to 4 LPM), see page F31<br />
Table Top Rebreathing<br />
PY2 72-6081 CDS 9000 Table Top Anesthesia Machine with<br />
Single O 2 Flowmeter (0.2 to 4 LPM), see page F31<br />
PY2 72-6082 CDS 9000 Table Top Anesthesia Machine with Dual O 2<br />
Flowmeter (0.2 to 4 LPM and 0 to 1000 cc), see page F31<br />
PY2 72-6083 CDS 9000 Table Top Anesthesia Machine with Single O 2<br />
and N 2O Flowmeters and Failsafe(0.2 to 4 LPM),<br />
see page F31<br />
F24<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
<strong>anesthesia</strong> <strong>guide</strong><br />
How to Select Anesthesia Equipment<br />
Evacuation System Selection Guide<br />
Evacuation Systems are necessary when waste gas from the animal still contains anesthetic agents. It must<br />
be removed from the exhausted gas before it can be released into the environment. What kind of evacuation<br />
systems are available for waste <strong>anesthesia</strong> gas Harvard Apparatus has several options to choose from. Select<br />
the system that best suits your application.<br />
F/Air Evacuation Pure-Guard Lab Animal AES Active Gas<br />
System Fluovac System Monitor System Evacuation System Evacuation System<br />
Canister Style Canister Style Canister Style Charcoal Cartridge Passive Flow System<br />
Evacuation System Evacuation System Evacuation System<br />
Each canister can be used for For use with a single For use with a single Can be used with up to For use with a single<br />
1 <strong>anesthesia</strong> machine, multiple <strong>anesthesia</strong> machine <strong>anesthesia</strong> machine 6 <strong>anesthesia</strong> machines <strong>anesthesia</strong> machine<br />
canisters for multiple machines<br />
Each canister can remove Each canister can remove 70 grams 1 lb No limitation on amount<br />
50 grams of pure 200 grams of halogenated of anesthetic agent<br />
halogenated anesthetic gases anesthetic gases<br />
Passively scavenges waste Actively scavenges waste Passively scavenges waste Actively or passively Active flow collects gas<br />
scavenges waste<br />
from <strong>anesthesia</strong> machine<br />
Does not require Does not require Does not require Maybe be vented directly Must be vented to a<br />
venting to a hood venting to a hood venting to a hood to room when using charcoal fume hood or outside<br />
cartridge or to a hood if desired. charcoal filtration<br />
Easy disposal in Easy disposal in Easy disposal in Charcoal may be disposed Two standard inlet port<br />
regular trash regular trash regular trash of in regular trash and on exhaust port hook<br />
up to existing equipment<br />
Canister is System Requires Fluosorber Canisters Requires Enviro-Pure Canisters Requires charcoal refill cartridges No cartridges required<br />
see page F34 see page F46 see page F35 see page F33 see page F34<br />
for complete details for complete details for complete details for complete details for complete details<br />
<strong>anesthesia</strong> <strong>guide</strong> Respiration<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />
F25
<strong>anesthesia</strong> <strong>guide</strong><br />
Evacuation System Selection Guide (continued)<br />
Evacuation System Selection Guide<br />
Harvard Apparatus offers five basic evacuation/scavenging systems that work with our <strong>anesthesia</strong> setups. A brief description of these systems<br />
and their components are listed below. Three of the systems have multiple configurations based on your <strong>anesthesia</strong> setup. The basic<br />
components are the same, just connections and adapters change with each configuration.<br />
F/Air Evacuation<br />
This evacuation system is a simple<br />
and economical way of removing<br />
anesthetic gases. The active<br />
charcoal in the canister removes<br />
the waste gas. The used canister<br />
can be tossed in the trash for<br />
disposal. See page F34 for<br />
complete details.<br />
Fluovac System<br />
The Fluovac Systems actively<br />
scavenges anesthetic waste and<br />
does not require venting to a<br />
hood. It uses the Fluosorber<br />
Canisters, which when full, can be<br />
disposed of in the regular trash.<br />
See page F46 for complete details.<br />
Respiration<br />
<strong>anesthesia</strong> <strong>guide</strong><br />
Configuration Components Order #<br />
1-A F/Air Canisters, case of 8 PY2 72-1294<br />
Tubing Connector PY2 60-5251<br />
Rodent Circuit Set PY2 72-3026<br />
Respiratory Adaptor PY2 72-2889<br />
1-B F/Air Canisters, case of 8 PY2 72-1294<br />
Tubing Connector PY2 60-5251<br />
Active Gas Evacuation<br />
This evacuation system removes<br />
the waste gas from the <strong>anesthesia</strong><br />
circuit and vents it to a waste<br />
system, ventilation hood or the<br />
outdoors. See page F34 for<br />
complete details.<br />
Configuration Components Order #<br />
3-A Fluovac System 110V (230V) PY2 34-0388/<br />
PY2 34-0387<br />
Fluosorber Canisters PY2 34-0415<br />
Pure-Guard Monitor<br />
System<br />
The Pure-Guard System is similar<br />
to the F-Air Canister Systems, but<br />
it removes all the guess work. The<br />
system monitors the status of the<br />
charcoal canister and alarms you<br />
when it requires changing. See<br />
page F35 for complete details.<br />
Configuration Components Order #<br />
2-A AES Active Gas Evacuation PY2 72-3065<br />
Tubing PY2 72-3093<br />
Male Adaptor, 19 mm PY2 72-3085<br />
Rodent Circuit Set PY2 72-3026<br />
Respiratory Adaptor PY2 72-2889<br />
2-B AES Active Gas Evacuation PY2 72-3065<br />
Tubing PY2 72-3093<br />
Male Adaptor, 19 mm PY2 72-3085<br />
2-C AES Active Gas Evacuation PY2 72-3065<br />
Tubing PY2 72-3093<br />
Configuration Components Order #<br />
4-A Pure-Guard Monitor System PY2 72-8119<br />
Rodent Circuit Set PY2 72-3026<br />
Respiratory Adaptor PY2 72-2889<br />
4-B Pure-Guard Monitor System PY2 72-8119<br />
Lab Animal Evacuation<br />
System<br />
This evacuation system is suitable<br />
for evacuating waste anesthetic<br />
gases from 1 to 6 stations. It was<br />
designed for those facilities to do<br />
not have built-in evacuation systems<br />
or fume hoods. See page F33 for<br />
complete details.<br />
Configuration Components Order #<br />
5-A Lab Animal Evacuation System PY2 72-3066<br />
Charcoal Refill PY2 72-3067<br />
F26<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
<strong>anesthesia</strong> <strong>guide</strong><br />
How to Select Anesthesia Equipment (continued)<br />
Classic T3<br />
Vaporizers<br />
PY2 60-5244 Manifold<br />
with 8 Ports<br />
Vaporizer Selection Guide<br />
Vaporizers are designed to work with a specific anesthetic agent. Select<br />
the vaporizer based on the agent you will be using in your laboratory.<br />
We offer vaporizers for Isoflurane and Sevoflurane, see page F36 for<br />
complete product offering. Please note that vaporizer endcaps are included<br />
with the <strong>anesthesia</strong> machine NOT the vaporizer. Therefore, if you are<br />
ordering a vaporizer ONLY you will need to order endcaps separately<br />
(1 x PY2 72-3043 and 1 x PY2 72-3044).<br />
Specifications<br />
Inlet Flow<br />
Compensation<br />
Temperature Range<br />
Compensation<br />
Calibration<br />
Accuracy<br />
Duration of Use<br />
Liquid Capacity<br />
Dimensions (H x W x D):<br />
Funnel Fill<br />
Key Fill<br />
Weight:<br />
Funnel Fill<br />
Key Fill<br />
T3<br />
50 mls to 10 liters/min with minimal change<br />
in output concentration<br />
59ºF to 95ºF (15ºC to 35ºC)<br />
69.8ºF (21ºC)<br />
± 15% (within above flow and temperature range)<br />
approximately 1.0 ml of liquid anesthetic is required<br />
to provide 200 ml of vapor<br />
125 ml liquid capacity, with 35 mls absorbed by wick<br />
7.25 in x 5 in x 5.5 in<br />
7.25 in x 5 in x 6 in<br />
16 lbs (7.27 kg)<br />
16 lbs (7.27 kg)<br />
Why Use an Anesthetic Manifold<br />
Manifolds allow the use of both an anesthetizing box and a mask. It<br />
permits the research to direct the flow of gas to where they need it. The<br />
anesthetizing box can be used to initially anesthetize the animal and then<br />
the mask can maintain the anesthetized state during procedures. One side<br />
of the manifold directs the fresh gas to the animal, while the other directs<br />
the waste gas collection.<br />
Harvard Apparatus does not suggest using manifolds to anesthetize<br />
multiple animals simultaneously. PLEASE NOTE, with a manifold, the<br />
amount of agent flowing into each port cannot be controlled – for<br />
individual control to multiple animals, see the Multi-Station Research<br />
System on page F33 of this catalog.<br />
Order # Product<br />
PY2 60-5242 4 Port Manifold – connects to 2 Anesthetic devices<br />
PY2 60-5243 6 Port Manifold – connects to 3 Anesthetic devices<br />
PY2 60-5244 8 Port Manifold – connects to 4 Anesthetic devices<br />
<strong>anesthesia</strong> <strong>guide</strong> Respiration<br />
Order #<br />
PY2 72-8132<br />
PY2 72-7995<br />
PY2 72-7997<br />
PY2 72-7996<br />
Product<br />
T3 Isoflurane Funnel-Fill Vaporizer*<br />
T3 Sevoflurane Funnel-Fill Vaporizer*<br />
T3 Isoflurane Key-Fill Vaporizer*<br />
T3 Sevoflurane Key-Fill Vaporizer*<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />
F27
<strong>anesthesia</strong> <strong>guide</strong><br />
Anesthesia System Selection Guide<br />
Anesthesia System Selection Guide<br />
Harvard Apparatus offers a wide range of Anesthesia configurations to meet most <strong>anesthesia</strong> needs.<br />
Summarized below are some of the systems available. Select from freestanding and table top <strong>anesthesia</strong><br />
machines. Each type is available with a variety of methods for connecting the <strong>anesthesia</strong> circuit to the animal.<br />
With each type of system there is also a variety of evacuation systems available. These evacuations systems<br />
are described in summary format with all of the required components on pages F25 and F26.<br />
Respiration<br />
<strong>anesthesia</strong> <strong>guide</strong><br />
Vaporstick System with Manifold –<br />
Connecting to a Box and a Mask<br />
Components Order #<br />
Vaporstick Anesthesia<br />
PY2 72-3007 for O 2 Only<br />
Machine<br />
PY2 72-3009 for O 2 and N 2O<br />
Vaporizer<br />
Depends on desired agent<br />
Manifold PY2 60-5242<br />
Anesthetizing Box<br />
PY2 50-0108 Small<br />
or PY2 50-0116 Large<br />
Supply Line Adaptor PY2 72-6000<br />
3/16” ID Tubing PY2 72-1024<br />
Options for Evacuation: (see pages F25 and F26)<br />
System<br />
Configuration<br />
F/Air Evacuation<br />
AES Active Gas Evacuation<br />
Fluovac System<br />
Pure-Guard Monitor System<br />
1A<br />
2A<br />
3A<br />
4A<br />
Table Top System with Manifold –<br />
Connecting to a Box and a Mask<br />
Components Order #<br />
Basic Table Top PY2 72-3011, PY2 72-3012,<br />
Anesthesia Machine<br />
or PY2 72-3013 for O 2 Only<br />
PY2 72-3014 for O 2/N 2O<br />
Vaporizer<br />
Depends on desired agent<br />
Manifold PY2 60-5242<br />
Anesthetizing Box<br />
PY2 50-0108 Small or<br />
PY2 50-0116 Large<br />
3/16” ID Tubing PY2 72-1024<br />
Options for Evacuation: (see pages F25 and F26)<br />
System<br />
Configuration<br />
F/Air Evacuation<br />
AES Active Gas Evacuation<br />
Fluovac System<br />
Pure-Guard Monitor System<br />
1A<br />
2A<br />
3A<br />
4A<br />
Vaporstick System with Mask Only<br />
Components Order #<br />
Vaporstick Anesthesia<br />
Machine<br />
Vaporizer<br />
Supply Line Adaptor PY2 72-6000<br />
PY2 72-3007 for O 2 Only<br />
PY2 72-3009 for O 2 and N 2O<br />
Depends on desired agent<br />
3/16” ID Tubing PY2 72-1024<br />
Options for Evacuation: (see pages F25 and F26)<br />
System<br />
F/Air Evacuation<br />
AES Active Gas Evacuation<br />
Fluovac System<br />
Pure-Guard Monitor System<br />
Configuration<br />
1A<br />
2A<br />
3A<br />
4A<br />
Table Top System with Mask Only<br />
Components Order #<br />
Basic Table Top PY2 72-3011, PY2 72-3012,<br />
Anesthesia Machine<br />
or PY2 72-3013 for O 2 Only<br />
PY2 72-3014 for O 2/N 2O<br />
Vaporizer<br />
Depends on desired agent<br />
3/16” ID Tubing PY2 72-1024<br />
Options for Evacuation: (see pages F25 and F26)<br />
System<br />
Configuration<br />
F/Air Evacuation<br />
AES Active Gas Evacuation<br />
Fluovac System<br />
Pure-Guard Monitor System<br />
1A<br />
2A<br />
3A<br />
4A<br />
F28<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
<strong>anesthesia</strong> <strong>guide</strong><br />
Anesthesia System Selection Guide (continued)<br />
Vaporstick System with Induction<br />
Chamber Only<br />
Components Order #<br />
Vaporstick Anesthesia<br />
Machine<br />
Vaporizer<br />
PY2 72-3007 for O 2 Only<br />
PY2 72-3009 for O 2 and N 2O<br />
Depends on desired agent<br />
Supply Line Adaptor PY2 72-6000<br />
Anesthetizing Box<br />
PY2 50-0108 Small or<br />
PY2 50-0116 Large<br />
3/16” ID Tubing PY2 72-1024<br />
Options for Evacuation: (see pages F25 and F26)<br />
System<br />
Configuration<br />
F/Air Evacuation<br />
AES Active Gas Evacuation<br />
Fluovac System<br />
Pure-Guard Monitor System<br />
1B<br />
B<br />
3A<br />
4B<br />
Table Top System with Induction<br />
Chamber Only<br />
Components Order #<br />
Basic Table Top PY2 72-3011, PY2 72-3012,<br />
Anesthesia Machine<br />
or PY2 72-3013 for O 2 Only<br />
PY2 72-3014 for O 2/N 2O<br />
Vaporizer<br />
Depends on desired agent<br />
Supply Line Adaptor PY2 72-6000<br />
Anesthetizing Box<br />
PY2 50-0108 Small or<br />
PY2 50-0116 Large<br />
3/16” ID Tubing PY2 72-1024<br />
Options for Evacuation: (see pages F25 and F26)<br />
System<br />
Configuration<br />
F/Air Evacuation<br />
AES Active Gas Evacuation<br />
Fluovac System<br />
Pure-Guard Monitor System<br />
1B<br />
2B<br />
3A<br />
4B<br />
Vaporstick System with Ventilator<br />
Components Order #<br />
Vaporstick Anesthesia<br />
Machine<br />
Vaporizer<br />
Ventilator<br />
PY2 72-3007 for O 2 Only<br />
PY2 72-3009 for O 2 and N 2O<br />
Depends on desired agent<br />
PY2 55-0000 Small Animal<br />
Model 683 Ventilator<br />
PY2 55-7058 Inspira Advanced<br />
Safety Ventilator – Volume<br />
Controlled<br />
PY2 55-7059 Inspira Advanced<br />
Safety Ventilator – Pressure<br />
Controlled<br />
PY2 73-0043/PY2 73-0044<br />
Mini Vent Mouse Ventilator<br />
Intubation/Tracheal Cannula Dependent on the weight range<br />
of animal being ventilated*<br />
Supply Line Adaptor PY2 72-6000<br />
If using 683 or Inspira Ventilators – you will also need:<br />
Connection Kit PY2 73-3076<br />
3/16” ID tubing PY2 72-1024<br />
If using the 687, MicroVent, MiniVent or MidiVent Ventilators – you will<br />
also need:<br />
Connection Kit PY2 73-3077<br />
Options for Evacuation: (see pages F25 and F26)<br />
System<br />
Configuration<br />
F/Air Evacuation<br />
1B<br />
AES Active Gas Evacuation 2C<br />
Fluovac System<br />
3A<br />
Pure-Guard Monitor System 4B<br />
* Note: Additional tubing may be necessary to connect to ventilator depending on size cannula<br />
selected. Please refer to Cannula Selection Chart on page F21.<br />
<strong>anesthesia</strong> <strong>guide</strong> Respiration<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />
F29
<strong>anesthesia</strong> <strong>guide</strong><br />
Anesthesia System Selection Guide (continued)<br />
Respiration<br />
<strong>anesthesia</strong> <strong>guide</strong><br />
Table Top System with Ventilator<br />
Components Order #<br />
Basic Table Top PY2 72-3011, PY2 72-3012,<br />
Anesthesia Machine<br />
or PY2 72-3013 for O 2 Only<br />
PY2 72-3014 for O 2/N 2O<br />
Vaporizer<br />
Depends on desired agent<br />
Ventilator<br />
PY2 55-0000 Small Animal<br />
Model 683 Ventilator<br />
Intubation/Tracheal Cannula<br />
PY2 55-7058 Inspira Advanced<br />
Safety Ventilator – Volume<br />
Controlled<br />
PY2 55-7059 Inspira Advanced<br />
Safety Ventilator – Pressure<br />
Controlled<br />
PY2 73-0043/PY2 73-0044<br />
Mini Vent Mouse Ventilator<br />
Dependent on the weight range<br />
of animal being ventilated*<br />
If using 683 or Inspira Ventilators – you will also need<br />
Connection Kit PY2 73-3076<br />
3/16” ID tubing PY2 72-1024<br />
If using the 687, MicroVent, MiniVent or MidiVent Ventilators – you will<br />
also need<br />
Connection Kit PY2 73-3077<br />
Options for Evacuation: (see pages F25 and F26)<br />
System<br />
Configuration<br />
F/Air Evacuation<br />
1B<br />
AES Active Gas Evacuation 2C<br />
Fluovac System<br />
3A<br />
Pure-Guard Monitor System 4B<br />
* Note: Additional tubing may be necessary to connect to ventilator depending on size cannula<br />
selected. Please refer to Cannula Selection Chart on page F21.<br />
Multi-Station Systems<br />
Components Order #<br />
Multi-Station<br />
Anesthesia Machine<br />
Vaporizer<br />
PY2 72-3023 Lab Animal<br />
2-Station System<br />
PY2 72-3024 Lab Animal<br />
4-Station System<br />
PY2 72-3025 Lab Animal<br />
6-Station System<br />
Depends on desired agent<br />
Options for Evacuation: (see pages F25 and F26)<br />
System<br />
Configuration<br />
F/Air Evacuation<br />
1B<br />
Lab Animal Evacuation<br />
5A<br />
Multi-Station Systems include Rodent Circuit Sets (circuit, mask, and uncut diaphragm) for all<br />
stations so they do not need to be ordered separately.<br />
“Thanks so much for the quote and all your technical<br />
advice. You folks at Harvard are so helpful, making<br />
my life much easier! It’s much appreciated.”<br />
F30<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
<strong>anesthesia</strong> equipment<br />
CDS 9000<br />
Small Animal Anesthesia Machine<br />
Common features of the small animal <strong>anesthesia</strong> machine include a pop-off<br />
valve designed to interface with an active waste gas evacuation system and<br />
maintain a passively full rebreathing bag; a non-rebreathing outlet port; and<br />
200 ml to four liter O 2 flowmeter. It has an easy, quick change absorber canister.<br />
Unit has flexibility to accommodate changing clinical practices with optional<br />
kits to convert from a tabletop unit to a pole mount or wall mount unit.<br />
• Universal anodized aluminum block with built in<br />
inhalation/exhalation valves<br />
• Powder coated for quick and easy cleaning<br />
• Pop-off valve maintains a passive breath in the<br />
rebreathing bag for ease of use<br />
• Fresh gas port<br />
• 200 ml to 4 liter O 2 flowmeter<br />
• Easy, quick change absorber canister<br />
• Two built-in handles for ease of mobility<br />
• Adaptable to all styles of vaporizers<br />
• Optional monitor bracket<br />
• Unit allows for flexibility to accommodate the<br />
changing research practices with optional kits to<br />
convert from a tabletop unit to a pole mount or to<br />
a wall mount unit<br />
• Great performance<br />
• Easy to service and maintain<br />
• Five year warranty<br />
Specifications<br />
Performance Characteristics:<br />
Absorber Canister<br />
Pop-Off Valve<br />
Inhalation/Exhalation Valves<br />
Flowmeter:<br />
Single<br />
Dual<br />
Flush Valve<br />
Pressure Manometer<br />
Gas Inlet(s)<br />
Vaporizer Connection<br />
Environmental:<br />
Operating Temperature<br />
Storage Temperature<br />
Dimensions & Weight:<br />
Pole Mount (H x W x D)<br />
Tabletop (H x W x D)<br />
900 cc<br />
19 mm, relieves at 2 cm H2O<br />
Tapered, 22 mm<br />
0.2 to 4 LPM<br />
0-1000 ml, 0.2 to 4 LPM<br />
10-15 LPM<br />
0-60 cm H2O, 0-30 cm H2O vacuum<br />
DISS male for all gases<br />
Tapered, 23 mm<br />
60°F to 90°F (15°C to 32°C)<br />
30°F to 120°F (-1°C to 48°C)<br />
53.25 in x 26 in x 26 in<br />
(135.3 cm x 66 cm x 66 cm), 10.4 kg (23 lbs)<br />
14.5 in x 14.25 in x 10.5 in<br />
(36.8 cm x 36.2 cm x 26.7 cm), 6.8 kg (15 lbs)<br />
Daily Pressure Test Recommended<br />
Calibration<br />
These Anesthesia Machine are supplied complete with the following:<br />
F-circuit with two liter bag<br />
Modified Jackson Rees with 1/2 liter bag<br />
Sodasorb ® CO2 Absorbent refill bag (2.2 lbs)<br />
Pop-Off Occlusion Valve<br />
Operation Manual<br />
Order # Product<br />
PY2 72-7992 CDS 9000 Pole Mount Anesthesia Machine with Single<br />
Flowmeter 0.2 to 4 LPM<br />
PY2 72-7993 CDS 9000 Pole Mount Anesthesia Machine with Dual<br />
Flowmeter 0-1000 ml, 0.2 to 4 LPM<br />
PY2 72-7994 CDS 9000 Pole Mount Anesthesia Machine with N 2O/O 2<br />
Flowmeter 0.2 to 4 LPM<br />
PY2 72-6081 CDS 9000 Tabletop Anesthesia Machine with Single<br />
Flowmeter 0.2 to 4 LPM<br />
PY2 72-6082 CDS 9000 Tabletop Anesthesia Machine with Dual<br />
Flowmeter 0-1000 ml, 0.2 to 4 LPM<br />
PY2 72-6083 CDS 9000 Tabletop Anesthesia Machine with N 2O/O 2<br />
Flowmeter 0.2 to 4 LPM<br />
Optional Conversion Kits & Brackets<br />
PY2 72-6073 Tabletop Kit<br />
PY2 72-6074 Wall Mount Kit<br />
PY2 72-6075 Pole Mount Kit<br />
PY2 72-6076 Monitor Bracket<br />
<strong>anesthesia</strong> equipment Respiration<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />
F31
<strong>anesthesia</strong> equipment<br />
Vaporstick Anesthesia & Basic Table Top Machines<br />
Vaporizer<br />
not included<br />
Vaporstick<br />
Anesthesia Machine<br />
• Economical <strong>anesthesia</strong><br />
delivery system<br />
• Dedicated unit for<br />
non-rebreathing circuits<br />
• Available with optional<br />
universal vaporizer<br />
mounting bracket<br />
• Can be upgraded to a<br />
rebreathing system with<br />
addition of free standing<br />
CO 2 absorber system<br />
PY2 72-3011<br />
Basic Table Top<br />
Anesthesia<br />
Machine<br />
Respiration<br />
<strong>anesthesia</strong> equipment<br />
The Vaporstick is a utility unit<br />
designed to supply oxygen to nonrebreathing<br />
systems, intensive care<br />
units and nebulizers. The flowmeter,<br />
adjusts from 0.2 to 4 LPM for accurate<br />
patient settings. A flush valve is<br />
included for fast immediate oxygen.<br />
The unit is mounted on a stable spider base (5 legs) and a post assembly.<br />
An owner’s manual and modified Jackson Rees non-rebreathing circuit with<br />
1/2 liter bag, PY2 72-3073, see page F41, are included with the <strong>anesthesia</strong><br />
machine. By adding your choice of options, you can customize the<br />
Vaporstick to suit your research <strong>anesthesia</strong> requirements. Z-bracket and<br />
endcaps are included. Vaporizer must be ordered separately.<br />
Order # Product<br />
PY2 72-3007 Vaporstick Anesthesia Machine<br />
PY2 72-3009 Vaporstick with O 2 and N 2O Flowmeters and Failsafe<br />
Optional Accessories<br />
PY2 72-3010 Freestanding CO 2 Absorber System<br />
PY2 72-3018 Single O 2 E-cylinder Regulator and Double Tank Holder,<br />
see page F37<br />
PY2 72-3020 Dual E-Cylinder O 2 Tank Yokes Holder and Regulator<br />
PY2 72-3017 Add-on Mayo Tray<br />
PY2 72-3049 Z-Bracket Universal Vaporizer Mounting Bracket<br />
(Vaporizer not included)<br />
Basic Table Top Anesthesia Machine<br />
• Economical benchtop <strong>anesthesia</strong> system<br />
• Dedicated system for non-rebreathing circuits<br />
• Accepts Series 100 vaporizers<br />
• Can be upgraded to a rebreathing system with the<br />
addition of a freestanding CO 2 absorber system<br />
• Now includes Rodent Circuit Set!<br />
The Basic Table Top Anesthesia Machine is a table top non-rebreathing system<br />
similar to the Vaporstick, see left. The Basic Table Top Anesthesia Machine<br />
is an extremely compact <strong>anesthesia</strong> machine, 8 in x 8 in x 13 in (L x W x H),<br />
making it ideal for locations where space is limited. Four models are available<br />
which differ only by the type of flowmeter supplied.<br />
An owners manual, Rodent Circuit Set and Modified Jackson Rees nonrebreathing<br />
circuit with 1/2 liter bag, PY2 72-3073, page F41, and endcaps<br />
PY2 72-3043 and PY2 72-3044 are included with the <strong>anesthesia</strong> machine.<br />
The optional freestanding CO 2 Absorber System, PY2 72-3010, features the<br />
same board block rebreathing circuit design as the CDS 9000 Table Top unit.<br />
Vaporizer must be ordered separately.<br />
Order #<br />
PY2 72-3011<br />
PY2 72-3012<br />
PY2 72-3013<br />
PY2 72-3014<br />
PY2 72-3010<br />
Product<br />
Table Top Research with 0.2 to 4 LPM O 2 Flowmeter<br />
Table Top Research with 0 to 1000 cc Flowmeter<br />
Table Top Research with Dual O 2 Flow Meters<br />
0.2-4 LPM and 0-1000 cc<br />
Table Top Research with N 2O and O 2 Flowmeter<br />
and Failsafe<br />
Freestanding CO 2 Absorber System<br />
F32<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
<strong>anesthesia</strong> equipment<br />
Anesthesia and Evacuation Systems<br />
PY2 72-3025<br />
(Vaporizer<br />
not included)<br />
Multi-Station<br />
Research Anesthesia<br />
System<br />
• Anesthesia delivery<br />
system designed<br />
specifically for research<br />
• Multiple, individually<br />
controlled stations in<br />
a single unit<br />
• Unique rodent circuit,<br />
mask and diaphragm<br />
system for safe,<br />
effective anesthetic<br />
agent delivery<br />
• Use with lab animal<br />
evacuation system<br />
The Multi-Station Research Anesthesia System is the latest technology for<br />
rodent and small animal <strong>anesthesia</strong>. The multi-station unit offers a base unit<br />
with multiple stations each individually controlled. The master flowmeter and<br />
auxiliary flowmeters all receive the same gas supply. The master flowmeter<br />
combined with an anesthetic vaporizer, Series T3, see page F36, are used to<br />
set the maximum percentage of anesthetic agent delivered to each station.<br />
Using the auxiliary flowmeters, the percentage of anesthetic agent can be<br />
diluted using the fresh gas supply from the auxiliary flowmeter. Using an<br />
easy-to-follow flow chart, each individual station can deliver a different<br />
percentage of anesthetic agent as needed, without effecting any other station.<br />
The unique rodent circuit, PY2 72-3026 features a coaxial tube used in<br />
conjunction with a mask. By placing the animal’s nose into the mask<br />
diaphragm, it receives the delivered gas/anesthetic agent mixture. Three<br />
different size diaphragms are available. The waste gas exhaled from the<br />
animal and any unused gas delivered by the <strong>anesthesia</strong> machine, is pulled<br />
around the inner cone through the outside hose of the Rodent Circuit. This<br />
waste gas can be removed from the breathing circuit using either in-house<br />
vacuum or the Lab Animal Evacuation system, PY2 72-3066. The unit is a<br />
simple to use, safe and effective anesthetic delivery and evacuation system<br />
designed specifically for laboratory research use.<br />
The Multi-station Research Anesthesia system is available with two (2), four<br />
(4), or six (6) stations. It is supplied with an operational manual, station hoses,<br />
rodent circuits which include, a mask, hose and a medium diaphragm and<br />
endcaps. A vaporizer, see page F36, and evacuation system must be<br />
purchased separately.<br />
An alternative to the Lab Animal Evacuation system is to connect each rodent<br />
circuit exhaust/exhalation line to it’s own F-Air Filter canister, see page F34.<br />
Order # Product<br />
PY2 72-3023 Lab Animal 2 Station Multi-Station Research System,<br />
2 animal<br />
PY2 72-3024 Lab Animal 4 Station Multi-Station Research System,<br />
4 animal<br />
PY2 72-3025 Lab Animal 6 Station Multi-Station Research System,<br />
6 animal<br />
PY2 72-3026 Circuit Set, Rodent, see page F41<br />
PY2 72-3027 Mask, Rodent (no diaphragm)<br />
PY2 72-3028 Rodent Mask Diaphragm Small (7/16 in Diameter)<br />
PY2 72-3029 Rodent Mask Diaphragm Medium (9/16 in Diameter)<br />
PY2 72-3030 Rodent Mask Diaphragm Large (3/4 in Diameter)<br />
<strong>anesthesia</strong> equipment Respiration<br />
PY2 72-3066 Lab Animal<br />
Evacuation System<br />
Lab Animal Evacuation System<br />
The Multi-Station Evacuation System was designed for those facilities that<br />
do not have a built-in evacuation system or a fume hood is not available. The<br />
waste gas from the system may be vented to a 2 inch outside line or pulled<br />
through activated charcoal so that the air can be recirculated in to the room.<br />
When using the filtration system, the activated charcoal must be changed on<br />
a regular basis, to maintain it’s effectiveness. Typically, 8 to 10 hours of<br />
<strong>anesthesia</strong> delivery can be performed for each new supply of charcoal. The lab<br />
evacuation system, will accommodate waste gas supply from 1 to 6 stations.<br />
PY2 72-3026<br />
Rodent Circuit Set<br />
Order # Product<br />
PY2 72-3066 Lab Animal Evacuation System, 110 VAC, 60 Hz<br />
PY2 72-3046 Lab Animal Evacuation System, 220 VAC, 50 Hz<br />
PY2 72-3067 Charcoal Refill<br />
NOTE: When using in-house suction, a scavenger interface valve must be used when operating<br />
more than one station, to reduce the pull of air.<br />
✐<br />
NOTE:<br />
To adapt port to 3/16" tubing,<br />
PY2 72-6000 and PY2 72-8209 are<br />
required–one of each per port to be adapted.<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />
F33
<strong>anesthesia</strong> equipment<br />
AES and F/Air Filter<br />
AES Active Gas<br />
Evacuation<br />
Anesthesia Evacuation Active Gas<br />
Evacuation System (AES)<br />
• Powered unit for safe and effective removal of<br />
anesthetic waste gas<br />
• Can be mounted to <strong>anesthesia</strong> machine pole or<br />
used as a free standing unit<br />
• Two inlet ports allow connection to an induction<br />
chamber and an <strong>anesthesia</strong> machine simultaneously<br />
Respiration<br />
<strong>anesthesia</strong> equipment<br />
Setup Showing AES Mounted to Pole of Anesthesia Machine<br />
Pop-off<br />
Valve<br />
Pop-off<br />
Valve<br />
Active Gas<br />
Evac. System<br />
Setup Showing AES Mounted to Wall<br />
19 mm<br />
Tubing<br />
19 mm<br />
Tubing<br />
1/2 inch<br />
Coupler<br />
Active Gas<br />
Evac. System<br />
1/2 inch<br />
PVC<br />
1/2 inch<br />
PVC<br />
The Anesthetic Evacuation System (AES) will safely and actively remove waste<br />
gas associated with everyday inhalation <strong>anesthesia</strong>. It can be mounted on the<br />
pole of the CDS 9000 or Vaporstick, see pages F31 to F32. It can also be used<br />
as a freestanding unit and simply placed on the benchtop. Two standard 19 mm<br />
(0.75 inch) inlets and one exhaust port allows easy hook-up to existing<br />
equipment. A 12 foot grounded electrical cord and lightweight tubing, allows<br />
for machine maneuverability.<br />
The waste gas from the pop-off valve on most rebreathing <strong>anesthesia</strong> machines<br />
is collected by passive flow to the AES. This allows for safe operation of the<br />
<strong>anesthesia</strong> machine with little or no vacuum exposure. Using a push blower,<br />
the AES actively removes the waste gas from the unit. The blower has the<br />
capacity of moving 12 cubic feet/minute through up to 150 feet of tubing to an<br />
outside vent or fume hood. The on/off switch illuminates a green light when the<br />
unit is activated. The ‘on’ light assures the operator that the unit is functioning.<br />
The Anesthetic Evacuation System includes a 3 inch and a 10 foot length of<br />
19 mm ID hose and a 12.5 mm (0.5 inch) PVC Adapter. Additional lengths of<br />
tubing may be required and are available as an option along with an adapter<br />
to interconnect the 19 mm outlet tubing. An optional outlet line ceiling plate<br />
is available when connection to an outside wall is not convenient. Unit is<br />
14 in. tall, 5 in. in diameter and weighs 5 lbs.<br />
Order #<br />
PY2 72-3064<br />
PY2 72-3065<br />
Accessories<br />
PY2 72-3093<br />
PY2 72-3085<br />
PY2 72-3070<br />
PY2 72-6001<br />
Product<br />
AES Active Gas Evacuation, 110 VAC 60 Hz<br />
AES Active Gas Evacuation, 220 VAC 50 Hz<br />
Tubing 19 mm (0.75 in) ID , 3 m (10 ft) length<br />
Male Adapters 19 x 19 mm<br />
Ceiling Plate Cover<br />
19-22 mm Adapters<br />
F/AIR Filter Canister<br />
• The easy and economical<br />
way to scavenge<br />
anesthetic gases<br />
This filter canister is the sensible<br />
answer for the removal of excess<br />
halogenated gases from the operating<br />
room environment. It can remove<br />
50 grams of pure halogenated<br />
anesthetic gases. It is convenient to<br />
use and does not require a venting<br />
hood. Simply pre-weigh canister noting the starting weight on the side of the<br />
canister. Monitor weight throughout the procedure and discard once canister has<br />
gained 50 grams. Once used, the canister is then simply disposed of in regular<br />
trash. A connector for tubing is sold separately, see below. The canister is<br />
15.2 cm (6 in) high with a diameter of 8.3 cm (3-1/4 in). Weight of active<br />
component is 200 grams.<br />
Order #<br />
Product<br />
PY2 60-0979 F/AIR Filter Canister, pkg. of 1<br />
PY2 72-1294<br />
PY2 60-5251<br />
Case of 8 F/AIR Filter Canisters<br />
Connector for Tubing for F/AIR Filter Canister<br />
F34<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
<strong>anesthesia</strong> equipment<br />
Pure-Guard System<br />
Pure-Guard System<br />
• Takes the guesswork out of knowing when to<br />
change your charcoal canister. Remember, agent<br />
concentration, flow rates and humidity can<br />
all affect the life of a charcoal canister. The<br />
Pure-Guard System alerts you when to change<br />
your canister and keeps you safe.<br />
• Patented system effectively removes halogenated<br />
agents from isoflurane and sevoflurane<br />
• Unique alarm system protects you and your staff<br />
by alerting you to waste anesthetic gas (WAG)<br />
breakthrough.<br />
• Larger Enviro-Pure canister contains 1/3 more<br />
charcoal than conventional canisters. So it lasts<br />
longer!<br />
• Inaccurate and unreliable recording of time is no<br />
longer necessary.<br />
• Provides a 20-minute window after the monitor<br />
alarm sounds before room air concentration exceeds<br />
NIOSH permissible exposure level of 2 ppm<br />
(10 x 10 x 8 room with no air exchange).<br />
• CE approved<br />
The Pure-Guard System protects lab personnel from dangerous waste<br />
gases anywhere you use it. Easy-to-use and safer than any other charcoal<br />
canister systems on the market, Pure-Guard combines the patented<br />
Enviro-Pure canister with a special monitor and alarm to offer you pure<br />
protection. Pure-Guard takes the guesswork out of when to change your<br />
canister by alerting you when the canister is full. As a result, you get<br />
excellent protection from waste anesthetic gases anywhere in the facility.<br />
Order #<br />
PY2 72-8119<br />
PY2 72-8120<br />
Product<br />
Pure-Guard System (includes 1 monitor and 6 pack of<br />
Enviro-Pure canisters)*<br />
Pure-Guard Monitor<br />
PY2 72-8121 Enviro-Pure Canister, pkg. of 6<br />
PY2 72-8122<br />
PY2 72-8123<br />
PY2 72-8124<br />
*Note: Not for use with halothane<br />
Pure-Guard 1 inch Pole Mount Bracket<br />
Pure-Guard 2 inch Pole Mount Bracket<br />
Pure-Guard Wall Mount Bracket<br />
<strong>anesthesia</strong> equipment Respiration<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />
F35
<strong>anesthesia</strong> equipment<br />
Vaporizers<br />
Classic T3 Anesthetic Vaporizers<br />
Anti-Spill<br />
Device<br />
Key-Fill<br />
Adapter<br />
Vaporizer Endcaps<br />
Vaporizer Manifolds<br />
Respiration<br />
<strong>anesthesia</strong> equipment<br />
• Classic T3 Vaporizers have a 3-year warranty<br />
• Vaporizers available for Isoflurane and Sevoflurane*<br />
• Annual service and vaporizer conversion available<br />
upon request<br />
Harvard Apparatus offers new anesthetic vaporizers. These vaporizers from<br />
the two most popular manufacturers of vaporizers in the world, Cyprane<br />
and Ohmeda (formerly Ohio Medical) come with a full warranty and with<br />
annual maintenance will offer a lifetime of service. Isoflurane and Sevoflurane<br />
specific vaporizers are available. The vaporizer manifold is included with the<br />
vaporizer.<br />
All vaporizers are designed to be unaffected by pressure, temperature and<br />
flow rate to give you accurate levels of agent concentrations. The vaporizer<br />
provides accurate delivery of anesthetic agent in the following ranges:<br />
from 0.25% - 5% in 1/4 increments up to 3% then 1/2 increments up to 5%.<br />
Simply choose the anesthetic agent desired.<br />
Specifications<br />
Inlet Flow<br />
50 mls to 10 liters/min with minimal change<br />
Compensation<br />
in output concentration<br />
Temperature Range 15ºC to 35ºC (59ºF to 95ºF)<br />
Compensation<br />
Calibration<br />
21ºC (69.8ºF)<br />
Accuracy<br />
±15% (within above flow and temperature range)<br />
Duration of Use<br />
approximately 1.0 ml of liquid anesthetic is required<br />
to provide 200 ml of vapor<br />
Liquid Capacity<br />
125 ml liquid capacity, with 35 mls absorbed by wick<br />
Dimensions (H x W x D) & Weight:<br />
Funnel Fill 18.4 cm x 12.7 cm x 14 cm (7.25 in x 5 in x 5.5 in)<br />
7.27 kg (16 lbs)<br />
Key Fill<br />
18.4 cm x 12.7 cm x 15.2 cm (7.25 in x 5 in x 6 in)<br />
7.25 in x 5 in x 6 in 16 lbs<br />
Order # Product<br />
PY2 72-8132 T3 Isoflurane Funnel-Fill Vaporizer*<br />
PY2 72-7995 T3 Sevoflurane Funnel-Fill Vaporizer*<br />
PY2 72-7997 T3 Isoflurane Key-Fill Vaporizer*<br />
PY2 72-7996 T3 Sevoflurane Key-Fill Vaporizer*<br />
Vaporizer Accessories<br />
PY2 72-3051 Filler Adapter for Key-Fill Vaporizer - Isoflurane<br />
PY2 72-3053 Filler Adapter for Key-Fill Vaporizer - Sevoflurane<br />
PY2 72-3054 Anti-Spill Device - Isoflurane<br />
PY2 72-3056 Anti-Spill Device - Sevoflurane<br />
PY2 72-3043 Male Endcap - Outlet<br />
PY2 72-3044 Female Endcap - Inlet<br />
*Note: Vaporizer Endcaps are not included with the Vaporizer. If you are only purchasing a<br />
Vaporizer, you must also purchase the Endcaps.<br />
F36<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
<strong>anesthesia</strong> equipment<br />
Anesthesia Machine Accessories<br />
PY2 60-5244 Manifold<br />
with 8 Ports<br />
Manifold<br />
These Manifolds permit the flow of gas to multiple anesthetic devices<br />
from only one vaporizer. One side of the Manifold directs the delivery of<br />
fresh gas while the other side directs the waste gas collection. Stopcocks,<br />
available separately, may be added to the circuit for increased control over<br />
the gas flow. Two stopcocks are required for each set of ports.<br />
These manifolds can also be used with the rodent circuit and induction<br />
chamber to initially anesthetize and maintain without disconnecting the<br />
circuit. Requires tubing with ID of 8 mm (0.25 in).<br />
*Not suggested for multiple animals, see lab animal multi-station on page F33.<br />
• Economical - permits more than one breathing<br />
device to be used with one vaporizer<br />
• Available with 4, 6, or 8 ports providing 2, 3, or 4<br />
anesthetic channels<br />
Order # Product<br />
PY2 60-5242 Manifold with 4 Ports for 2 Anesthetic Devices<br />
PY2 60-5243 Manifold with 6 Ports for 3 Anesthetic Devices<br />
PY2 60-5244 Manifold with 8 Ports for 4 Anesthetic Devices<br />
PY2 60-5245 Stopcock for use with Manifolds, pkg. of 2<br />
PY2 72-3104<br />
O2 Regulator with<br />
0-15 L/M Flowmeter<br />
0-3 Liters/Minute<br />
O2 Flow-meter<br />
O2 and N2O<br />
E-Cylinder<br />
Regulator<br />
Manifolds, Regulators,<br />
Flowmeters and<br />
Hoses<br />
Many accessories to connect a gas<br />
source (O 2 or N 2O ) to an <strong>anesthesia</strong><br />
machine are available. Regulators<br />
are specific for type of gas and tank<br />
size (small, E-cylinder or large,<br />
H-cylinder) used. All regulators<br />
terminate in a gas specific male<br />
DISS fitting. E-cylinder regulators<br />
attach to tank using a yoke and can<br />
only be used with E-size tanks with<br />
a post block. Other fittings and<br />
connectors available, call Harvard<br />
Apparatus Tech Support for more info.<br />
PY2 72-3020<br />
See description<br />
below<br />
O2 and N2O<br />
H-Cylinder<br />
Regulator<br />
Order # Product<br />
PY2 72-3099 O 2 Regulator for E-Cylinder (Includes O 2 Hose)<br />
PY2 72-3100 O 2 Regulator for H-Cylinder (O 2 Hose ordered separately)<br />
PY2 72-3103 O 2 Regulator for E-Cylinder with 0 to 15 LPM Flowmeter<br />
(Includes O 2 Hose)<br />
PY2 72-3104 O 2 Regulator for H-Cylinder with 0 to 15 LPM Flowmeter<br />
PY2 72-3102 N 2O Regulator for H-Cylinder<br />
PY2 72-3018 Single O 2 E-Cylinder Regulator & Double Tank Holder<br />
PY2 72-3020 Dual E-Cylinder O 2 Tank Yokes Holder and Regulator<br />
PY2 72-3112 0 to 3 LPM O 2 Flowmeter 2<br />
PY2 72-7458 O 2 Regulator for H-Cylinder with 0 to 3 LPM Flowmeter<br />
PY2 72-3113 0 to 5 LPM O 2 Flowmeter 2<br />
PY2 72-3114 0 to 15 LPM O 2 Flowmeter 2<br />
PY2 72-3115 O 2 Hose, 10 ft 3<br />
PY2 72-3116 O 2 Hose, 15 ft 3<br />
PY2 72-3117 O 2 Hose, 20 ft 3<br />
PY2 72-3118 N 2O Hose, 10 ft 3<br />
PY2 72-3119 N 2O Hose, 15 ft 3<br />
PY2 72-3120 N 2O Hose, 20 ft 3<br />
PY2 72-5810 DISS Female Hose Barb - O 2<br />
<strong>anesthesia</strong> equipment Respiration<br />
PY2 72-5811<br />
DISS Female Hose Barb - N 2O<br />
1. Replacement flowmeters for <strong>anesthesia</strong> machines are available, call for details<br />
2. Flowmeter with Female DISS inlet and Male DISS outlet<br />
3. Connectors on both ends are Female DISS<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />
F37
<strong>anesthesia</strong> equipment<br />
COAX Breathing Device and Respiratory Adapters<br />
PY2 72-7109<br />
Respiratory Adapters<br />
These polypropylene adapters are<br />
used to connect different tubing<br />
sizes together in respiratory circuits.<br />
Respiration<br />
<strong>anesthesia</strong> equipment<br />
PY2 72-7108<br />
COAX Breathing Device<br />
• For rodents, guinea pigs, and birds<br />
• Durable – constructed of Delrin<br />
This COAX breathing device is a precisely machined apparatus which maintains<br />
the surgical plane. The fresh anesthetic gas enters the side port and then<br />
passes to the nose cone. At this point the anesthetic gas is mixed with the<br />
patient’s respiration and then passes out through a ball check valve to the<br />
gas outlet for scavenging. The positive pressure from the oxygen source and<br />
the patient’s respiration lifts the precision ball valve for scavenging. A #10<br />
balloon acts as a diaphragm or breathing bag.<br />
The COAX is available as a free standing unit or mounted to a durable HDPE<br />
procedure table. This table includes metal strips to hold heating pads in place<br />
and points for tie downs. This unit is supplied with face masks (2 rat and<br />
2 mouse), height adjustment collars and 10 ft. of 0.25 in ID tubing. The unit<br />
measures H x W x L, 2 x 40.6 x 31.8 cm (4 x 16 x 12-1/2 in).<br />
Order # Product<br />
PY2 72-7108 Height Adjustable Delrin COAX<br />
PY2 72-7109 Height Adjustable Delrin COAX with Table<br />
Order # Product<br />
PY2 72-2889 Respiratory Adapter, 6 to 22 mm (0.24 to 0.87 in),<br />
pkg. of 10<br />
PY2 72-2890 Respiratory Adapter, 8 to 22 mm (0.31 to 0.87 in),<br />
pkg. of 10<br />
PY2 72-2891 Respiratory Adapter, 10 to 22 mm (0.39 to 0.87 in),<br />
pkg. of 10<br />
PY2 72-2892 Respiratory Adapter, 12 to 22 mm (0.47 to 0.87 in),<br />
pkg. of 10<br />
PY2 72-2893 Respiratory Adapter, 15 to 22 mm (0.59 to 0.87 in),<br />
pkg. of 10<br />
PY2 72-2894 Respiratory Adapter, 18 to 22 mm (0.71 to 0.87 in),<br />
pkg. of 10<br />
Anesthetizing Box<br />
• For <strong>anesthesia</strong> induction<br />
• Transparent walls<br />
• All joints are carefully<br />
cemented<br />
• Nylon inlet and outlet<br />
on the opposite walls<br />
• Magnetic rubber for<br />
sealing and closing cover<br />
The Panlab thick transparent Perspex Anesthetizing Box allows for constant<br />
observation of the animal while anesthetizing, which helps protect against<br />
accidental overdosing.<br />
Two models are available: one for small rodents, another for medium<br />
animals (rabbit, cats).<br />
Specifications<br />
Material Composition<br />
Dimensions:<br />
for Rats<br />
for Rabbits<br />
Inlet/Outlet External Diameter<br />
Perspex<br />
24 x 15 x 15 cm (9.5 x 5.9 x 5.9 in)<br />
40 x 29 x 29 cm (15.7 x 11.4 x 11.4 in)<br />
8 mm (0.3 in)<br />
Order #<br />
PY2 76-0004<br />
PY2 76-0005<br />
Product<br />
Air Tight Anesthetizing Box for Rats<br />
Air Tight Anesthetizing Box for Rabbits<br />
F38<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
induction chambers<br />
Induction Chamber, Anesthetizing Boxes and<br />
Backdraft Anesthesia Table<br />
PY2 60-5246 Induction Chamber<br />
Induction Chamber<br />
• Clear acrylic for easy<br />
animal observation<br />
• Two sizes<br />
• Ideal for small animals<br />
• Stainless steel false<br />
bottom for easy<br />
cleaning<br />
This cylindrical acrylate chamber is<br />
ideal for anesthetizing small animals<br />
such as rodents, guinea pigs, and<br />
birds. It has two, 1/4 inch barbed hose<br />
fittings, one for gas delivery and one for gas scavenging. The gas delivery<br />
barb directs the flow of anesthetic gas towards the bottom of the chamber.<br />
The chamber has a routed top that ensures a perfect fit. There are no<br />
corners so cleaning is easy. Includes 10 ft of 0.25 in ID tubing.<br />
Dimensions<br />
Inner, H x Dia<br />
Small<br />
Large<br />
Overall, H x Dia<br />
Small<br />
Large<br />
Barbs<br />
Order #<br />
PY2 72-7110<br />
PY2 60-5246<br />
Product<br />
20.3 x 20.3 cm (8 x 8 in)<br />
8.89 x 13.3 cm (3.5 x 5.25 in)<br />
20.3 x 20.3 cm (8 x 8 in)<br />
30.5 x 27.9 cm (12 x 11 in)<br />
17.8 x 17.8 cm (7 x 7 in)<br />
30.5 x 27.9 cm (12 x 11 in)<br />
Accepts, ID x OD, 6 x 8 mm<br />
(1/8 x 1/4 in) tubing<br />
Induction Chamber, Small<br />
Induction Chamber, Large<br />
PY2 50-0116<br />
PY2 50-0108<br />
Anesthetizing Boxes<br />
These anesthetizing boxes are<br />
constructed of 6 mm (1/4 in) thick,<br />
transparent plastic, with all joints<br />
securely cemented. The transparent<br />
plastic allows the animal to be under<br />
constant observation. Two 4.8 mm<br />
(3/16 in) nylon tubing connectors are<br />
cemented on opposite ends of the<br />
box, one at the top and the other at<br />
the bottom, for introducing and<br />
removing the gas.<br />
These boxes are available in two sizes: small and large. The small box is<br />
for rodents. The top slides open lengthwise on machined grooves. The<br />
large box is for larger animals such as rabbits and cats. Its top has three<br />
hinges for easy opening. Two fasteners squeeze the top down against a<br />
rubber gasket to seal the joints.<br />
The small box measures, H x W x D, 10.7 x 25.7 x 11 cm (4 x 10 x 4.5 in).<br />
The large box measures, H x W x D, 29 x 44 x 29 cm (11.5 x 19.5 x 11.5 in).<br />
*Note: Boxes must be cleaned with an acrylic approved cleaner - not alcohol.<br />
Order #<br />
PY2 50-0108<br />
PY2 50-0116<br />
Product<br />
Anesthetizing Box, Small<br />
Anesthetizing Box, Large<br />
induction chambers Respiration<br />
Portable Down<br />
Draft Table<br />
• Pulls anesthetic gases<br />
down and away from<br />
the researchers<br />
• Better access to animals<br />
than conventional<br />
fume hoods<br />
• Superior design and<br />
construction prevent<br />
debris accumulation<br />
Specifications<br />
Total Dimensions:<br />
Tabletop<br />
Work area<br />
Sidewalls<br />
Weight<br />
Material<br />
Airflow<br />
Voltage<br />
Autoclavable<br />
64.8 x 76.2 cm (25.5 x 30 in)<br />
61 x 76.2 cm (24 x 30 in)<br />
43.2 x 61 cm (17 x 24 in)<br />
7.6 cm (3 in) out from perforated tabletop<br />
20.4 kg (45 lbs) for tabletop<br />
10.4 kg (23 lbs) for blower (without filter)<br />
Stainless Steel<br />
90 ft/min average velocity at surface;<br />
50 ft/min average velocity 3” above tabletop surface<br />
110 VAC only<br />
Yes<br />
Our downdraft table provides an effective way to protect workers from<br />
exposure to anesthetics, chemicals, and debris particles. Various filters are<br />
available to provide the safest surgical environment possible.<br />
Tables are available with a single speed blower unit or with accessories to<br />
vent the system outdoors.<br />
Optional accessories include shelving and an anodized aluminum cart.<br />
Order # Product<br />
PY2 72-6201 Portable Down Draft Table with Blower<br />
PY2 72-6202 Portable Down Draft Table with Vent<br />
PY2 72-6205 Aluminum Cart<br />
PY2 72-6206 Potassium Permanganate filters, pkg. of 2<br />
PY2 72-6207 Carbon Filters, pkg. of 2<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />
F39
<strong>anesthesia</strong> accessories<br />
Anesthesia Masks and Inhalation Narcosis Chamber<br />
PY2 59-8202<br />
PY2 59-7977<br />
Large Canine<br />
Ventilation Mask<br />
PY2 59-8201<br />
PY2 59-8203<br />
Respiration<br />
<strong>anesthesia</strong> accessories<br />
Cat Ventilation/Anesthesia Masks<br />
These soft pliable vinyl plastic masks conform to the facial contours of a cat.<br />
They are fitted with a standard 15 mm (3/5 in) taper for connection to<br />
<strong>anesthesia</strong> machines, see pages F31 to F33. They are available in three sizes<br />
and are supplied individually or as a convenient set containing one mask of<br />
each size.<br />
The mask diameters are 25 mm (1 in), 38 mm (1-1/2 in), and 50 mm (2 in) for<br />
the small, medium and large size masks respectively.<br />
Order # Product<br />
PY2 59-8201 Cat Ventilation/Anesthesia Mask, Small<br />
PY2 59-8202 Cat Ventilation/Anesthesia Mask, Medium<br />
PY2 59-8203 Cat Ventilation/Anesthesia Mask, Large<br />
PY2 59-8204 Set of 3 Masks, one of each size<br />
PY2 59-6717 Inhalation Narcosis<br />
Chamber<br />
Inhalation Narcosis<br />
Chamber<br />
• Convenient for<br />
anesthetizing small<br />
animals, such as mice,<br />
hamsters, rats, or<br />
guinea pigs<br />
A clear acrylic hinged cover permits<br />
observation of animals. All other<br />
components are made of polypropylene and are not affected by anesthetic<br />
compounds.<br />
A folding perforated platform is removed to fill the bottom with cotton and<br />
replaced to support the animal. Anesthetic is poured into the small funnel<br />
at the side and runs into the bottom of the chamber where it is absorbed<br />
by cotton. A second stopcock on the other side of the chamber permits the<br />
entrance of fresh air during <strong>anesthesia</strong> to prevent suffocation.<br />
Maximum ID is 197 mm (7-3/4 in); top ID is 178 mm (7 in); height from<br />
platform to top is 127 mm (5 in); height under platform is 57 mm (2-1/4 in);<br />
overall height is 197 mm (7-3/4 in).<br />
Order # Product<br />
PY2 59-6717 Inhalation Narcosis Chamber<br />
Canine Ventilation/Anesthesia Masks<br />
These masks provide a convenient way of providing artificial ventilation or<br />
administration of anesthetic gases to dogs. They are constructed of rugged<br />
transparent polycarbonate. One end has a standard 15 mm (3/5 in) taper for<br />
connection to <strong>anesthesia</strong> tubing, while the other end has a soft flexible<br />
rubber diaphragm that molds itself to the contours of a dog’s snout.<br />
Two sizes are available. The small mask has an unstretched diaphragm<br />
opening of 2.5 cm (1 in), while the large mask has an unstretched opening<br />
of 4.4 cm (1-3/4 in).<br />
Order # Product<br />
PY2 72-8206 Canine Ventilation/Anesthesia Mask, Small<br />
PY2 72-8203 Canine Ventilation/Anesthesia Mask, Large<br />
PY2 72-8207 Replacement Diaphragm for Small Mask<br />
Small Animal<br />
Anesthesia Masks<br />
• For rats, guinea pigs,<br />
birds, and mice<br />
• Simple, yet effective<br />
design<br />
PY2 59-8255<br />
These Anesthesia Masks were<br />
designed with smaller animals in<br />
mind. They have a simple cylindrical<br />
PY2 59-8254<br />
shape with a rubber diaphragm. A<br />
small slit is cut in the diaphragm to<br />
accommodate the animal’s snout or<br />
beak. The opposite end tapers down to a standard press fitting port<br />
measuring 15.3 mm OD x 11.9 mm ID. These Masks can be used with bain<br />
circuits, non-rebreathing systems, or ‘Y’ pieces. Includes 1 diaphragm.<br />
Order # Product<br />
PY2 59-8254 Mouse Anesthesia Mask<br />
PY2 59-8255 Rat, Guinea Pig and Bird Anesthesia Mask<br />
PY2 72-3923 Replacement Diaphragms, pkg. of 10<br />
F40<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
<strong>anesthesia</strong> accessories<br />
Anesthesia Circuits<br />
PY2 72-3026 Rodent<br />
Circuit Set<br />
PY2 72-3073 Modified<br />
Jackson Rees (MJR)<br />
Non-rebreathing<br />
Anesthesia<br />
Circuit<br />
Rodent Mask and C-Pram Circuit<br />
Modified Jackson Rees (MJR)<br />
Non-Rebreathing Anesthesia Circuit<br />
The Modified Jackson Rees (MJR) is a new design for non-rebreathing.<br />
Unlike the old scavenging units, this system incorporates a relief valve on<br />
the main unit which allows the use of any size bag. This system will adapt<br />
to all <strong>anesthesia</strong> machines and does not require a Bain Block.<br />
Machine End View of Circuit<br />
Rodent Circuit Mask<br />
• Unique circuit designed specifically for rodent<br />
<strong>anesthesia</strong><br />
• Will work with any non-rebreathing <strong>anesthesia</strong><br />
machine<br />
Order #<br />
PY2 72-3073<br />
PY2 72-3075<br />
PY2 72-3043<br />
PY2 72-3074<br />
Product<br />
Modified Jackson Rees (Non-Rebreather) and<br />
1/2 Liter Bag<br />
Avian/Research MJR and 1/4 Liter Bag<br />
Male Endcap (to connect at outlet end of vaporizer)<br />
Add on Non-Rebreather Adapter<br />
<strong>anesthesia</strong> accessories Respiration<br />
Developed in conjunction with leading research facilities, the Rodent Circuit<br />
is the most effective, user-friendly, mask for rodents. Available with 3 different<br />
size diaphragms, the mask easily fits most rodents. With the use of a C-Pram<br />
circuit shown above, the mask is designed to deliver and evacuate the gas<br />
through one tube. Traditionally, the open mask system has caused problems<br />
because of the contamination of waste gas to the staff and the patient<br />
rebreathing CO 2<br />
. These problems are avoided with the Rodent Circuit and mask<br />
design. When combined with in-house suction or the Lab Animal Evacuation<br />
System or F/Air canister, see page F34, there is minimal risk of untoward<br />
anesthetic agent exposure for the researcher. Inlet tubing: 6.25 mm (0.25 in)<br />
ID, silicone tubing. Outlet from rodent circuit is a 22 mm (0.866 in) respiratory<br />
fitting. Respiratory Adapters are available to connect the rodent circuit outlet<br />
to tubing of various sizes from 6 to 15 mm ID, see page F38.<br />
Order # Product<br />
PY2 72-3026 Circuit Set, Rodent (hose, mask and uncut<br />
diaphragm)<br />
PY2 72-3027 Mask, Rodent (no diaphragm)<br />
PY2 72-3028 Rodent Mask Diaphragm Small (7/16 in DIA)<br />
PY2 72-3029 Rodent Mask Diaphragm Medium (9/16 in DIA)<br />
PY2 72-3030 Rodent Mask Diaphragm Large (3/4 in) DIA)<br />
PY2 72-3071 Universal F-Circuit<br />
Rebreathing Anesthesia Circuit<br />
Universal Rebreathing Anesthesia F-Circuit<br />
The Universal F-circuit is a rebreathing circuit that can be used on small animals<br />
up to 200 lbs. Rebreathing circuits allow the animal to rebreathe exhaled and<br />
excess vaporized anesthetic agent which have circulated through a CO 2 absorber<br />
system thus reducing the amount of anesthetic agent used. The unique single<br />
limb circuit 1) replaces the need for a traditional adult and pediatric circuit,<br />
2) reduces the clutter around the animal and 3) takes the weight off the end<br />
of the endotracheal tube. The tube within a tube design allows heat and<br />
moisture to be retained in the circuit, which helps to maintain body temperature<br />
and recover the patient more quickly.<br />
Order # Product<br />
PY2 72-3071 40 inch F-Circuit (rebreathing)<br />
PY2 72-3072 60 inch F-Circuit (rebreathing)<br />
PY2 72-3082 F-Circuit Elbow<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />
F41
ims <strong>anesthesia</strong><br />
Anesthetic Workstation and Systems<br />
Respiration<br />
ims <strong>anesthesia</strong><br />
Mobile Anesthetic Post<br />
NEW Mobile Anesthetic Post System<br />
Our new mobile anesthetic post system is a stable wheeled base with a<br />
sturdy support pole. Already fixed to the post is an attachment to mount<br />
your pin index regulator of choice (size E Bottles) Simply select your base<br />
unit and select your small <strong>anesthesia</strong> bracket then your regulator (suitable<br />
for E size bottles). The small anesthetic bracket unit is already manufactured<br />
with all the necessary ports to simply fit to the top of this pole. This<br />
enables our bracket systems to be adapted into a wheeled solution for<br />
ease of use. Simply design your small bracket unit, include your regulator<br />
from the selection below and include the regulator to flowmeter high<br />
pressure hose set and you have a complete system.<br />
Regulators for Post System:<br />
Order #<br />
PY2 34-1060<br />
PY2 34-1257<br />
Product<br />
O 2 Pin index regulator for E size cylinders<br />
Air Pin Index regulator for E size cylinders<br />
Complete<br />
Anesthetic Systems<br />
• Fittings and gauges<br />
for 1 x O 2 and 1 x N 2 O<br />
size E cylinders<br />
•O 2 and N 2 O tapered<br />
veterinary flowmeters<br />
•O 2 flush<br />
• Low O 2 alarm with N 2 O<br />
safety cut out device<br />
• Smooth running<br />
anti-static castors<br />
• Stainless steel shelving<br />
• Stainless steel fittings<br />
and tubing<br />
As well as the modular systems<br />
Complete Anesthetic Systems<br />
already offered in this catalog,<br />
International Marketing Supply now<br />
to offers an “off the shelf” complete <strong>anesthesia</strong> system designed specifically<br />
for the research laboratory.<br />
Specifications<br />
Dimensions:<br />
Over All, H x W x D 1415 x 480 x 720 mm (55.7 x 18.9 x 28.4 in)<br />
Top Shelf, D x W 480 x 400 mm (18.9 x 15.8 in)<br />
Order # Product<br />
PY2 34-0480 Complete Anesthetic System with Halothane<br />
Funnel Fill Vaporizer<br />
PY2 34-0481 Complete Anesthetic System with Halothane<br />
Key Fill Vaporizer<br />
PY2 34-0482 Complete Anesthetic System with Isoflurane<br />
Funnel Fill Vaporizer<br />
PY2 34-0483 Complete Anesthetic System with Isoflurane<br />
Key Fill Vaporizer<br />
High Pressure Tubing Assembly:<br />
Order #<br />
PY2 34-1385<br />
PY2 34-1386<br />
PY2 34-1387<br />
Product<br />
High Pressure Hose from O 2 Regulator to Flowmeter,<br />
includes connectors<br />
High Pressure Hose from N 2O Regulator to Flowmeter,<br />
includes connectors<br />
High Pressure Hose from Air Regulator to Flowmeter,<br />
includes connectors<br />
F42<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
ims <strong>anesthesia</strong><br />
Anesthesia Bracket Units<br />
PY2 34-0412 PY2 34-1352<br />
Equipment not included<br />
Anesthetic Bracket Units - Create Your<br />
Own System<br />
Our anesthetic bracket systems are easy! Select your base unit, flowmeters,<br />
vaporizer type, and source of gas supply and select the corresponding part<br />
numbers, your bracket will then be completely assembled to your specification<br />
and supplied complete.<br />
Vaporizer Options<br />
Select your vaporizer of choice from the table below, all vaporizers are new<br />
and come with a 3 year warranty and service interval. Each vaporizer is<br />
calibrated specifically to the specified anesthetic drug. Please note if ordering<br />
the Selectatec vaporizer you will additionally need to order the compatability<br />
block (PY2 34-1091).<br />
Equipment not included<br />
Order # Product<br />
Base Unit Options: Large Bracket<br />
PY2 34-1405 Large Bracket System 1-2 gas<br />
PY2 34-1406 Wall mounting System for Large Bracket<br />
PY2 34-0403 Oxygen Flow Meter for Large Bracket<br />
PY2 34-0404 N 2<br />
0 Flow Meter for Large Bracket<br />
PY2 34-1126 Air Flow Meter for Large Bracket<br />
PY2 34-1138 Carbon Dioxide Flow Meter for Large Bracket<br />
PY2 34-1067 Outlet Tube Mount 23mm for Vaporizer<br />
PY2 34-1068 Inlet Tube Mount 23mm for Vaporizer<br />
PY2 34-1264 Oxygen Flush System for Rapid Recovery<br />
Base Unit Options: Small Bracket<br />
PY2 34-1352 Small Bracket 1-2 gas<br />
PY2 34-1404 Wall Mounting System for Small Bracket<br />
PY2 34-1420 Oxygen Flow Meter for Small Bracket 0.2 – 2.0 liter/min<br />
PY2 34-1261 Nitrous Flow Meter for Small Bracket 0.2 – 2.0 liter/min<br />
PY2 34-0781 Air Flow Meter for Small Bracket 0.2 – 2.0 liter/min<br />
PY2 34-1067 Outlet Tube Mount 23mm for Vaporizer<br />
PY2 72-3044 Inlet Tube Mount 23mm for Vaporizer<br />
ims <strong>anesthesia</strong> Respiration<br />
Cage Mount<br />
Anesthetic Agent Vaporizer Select<br />
Isoflurane Pour Fill PY2 34-1040 PY2 34-1259 + PY2 34-1091<br />
Isoflurane Key Fill PY2 34-1041 PY2 34-1172 + PY2 34-1091<br />
Halothane Pour Fill PY2 34-1101 PY2 34-1260 + PY2 34-1091<br />
Halothane Key Fill PY2 34-1102 PY2 34-1213 + PY2 34-1091<br />
Sevoflurane Pour Fill PY2 34-1269 PY2 34-1271 + PY2 34-1091<br />
Sevoflurane Key Fill PY2 34-1270 PY2 34-1272 + PY2 34-1091<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />
F43
ims <strong>anesthesia</strong><br />
NEW Trolley Anesthesia Systems<br />
Harvard Apparatus has developed an extensive range of off the shelf<br />
<strong>anesthesia</strong> trolley systems, suitable for a wide range of applications. These<br />
mobile trolley systems have anti-static castors, stainless steel shelving,<br />
veterinary flowmeters, pin index regulators (suitable for E-size gas bottles).<br />
Specifications<br />
Dimension (H x W x D)<br />
Top Shelf (D x W)<br />
1415 x 480 x 720 mm (55.7 x 18.9 x 28.3 in)<br />
480 x 400 mm (18.9 x 15.8 in)<br />
Complete Pre-Configured Systems<br />
Please refer to the simple selection table below to select your appropriate<br />
trolley system for your requirements. All systems are supplied complete,<br />
and include all regulators, flowmeter(s), vaporizer, tube mounts and are<br />
supplied fully assembled and tested.<br />
Respiration<br />
ims <strong>anesthesia</strong><br />
Complete Pre-Configured Systems<br />
Isoflourane Halothane Key Fill Pour Fill Low O 2 N 2 O<br />
Order # Oxygen N 2 O Vaporizer Vaporizer Vaporizer Vaporizer Alarm cut off<br />
PY2 34-1048 • – • – – • – –<br />
PY2 34-1049 • – – • – • – –<br />
PY2 34-1050 • • • – – • • •<br />
PY2 34-1051 • • – • – • • •<br />
PY2 34-1117 • – • – • – – –<br />
PY2 34-1118 • – – • • – – –<br />
PY2 34-1119 • • • – • – • •<br />
PY2 34-1120 • • – • • – • •<br />
• Included with system<br />
– not included with system<br />
F44<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
ims <strong>anesthesia</strong><br />
Anesthetic Bracket Unit, Vaporizers<br />
and Tube Mounts<br />
PY2 34-0412<br />
PY2 34-0397<br />
Anesthetic Bracket Unit<br />
An alternative means of mounting the anesthetic components (rather than<br />
using the Anesthetic Workstation), is the IMS Anesthetic Bracket Unit. The<br />
Anesthetic Bracket Unit can either be FREE STANDING on a bench or WALL<br />
MOUNTED, with the fixings supplied. It is drilled ready to accept one<br />
flowmeter (single gas unit) or two flowmeters (two gas unit). Flowmeters<br />
must be ordered separately.<br />
Specifications<br />
Dimensions, H x W x D<br />
460 x 450 x 170mm (18.1 x 17.7 x 6.7 in)<br />
Order # Product<br />
PY2 34-0411 Anesthetic Bracket for Single Gas<br />
PY2 34-0412 Anesthetic Bracket for Two Gases<br />
Equipment not included<br />
Halovet Vaporizer<br />
• Graduated in 0.5% divisions<br />
• For continuous flow “Out of circuit” use<br />
• Single control, locks in “off” position<br />
• Compatible with most types of anesthetic<br />
machines and fittings<br />
• Supplied as 8% version<br />
This unit is a flow and temperature compensated vaporizer. It is supplied<br />
complete with mounting block and screws. Servicing is carried out directly<br />
with the manufacturer.<br />
Order # Product<br />
PY2 34-0397 Halovet Vaporizer, Funnel Fill<br />
PY2 34-0398 Halovet Vaporizer, Key Fill<br />
PY2 34-0401 Key Fill Adapter<br />
ims <strong>anesthesia</strong> Respiration<br />
PY2 34-0399 PY2 34-0400<br />
Halovet Tube Mounts<br />
Order # Product<br />
PY2 34-0399 Halovet Inlet Tube Mount for 22mm Vaporizers<br />
PY2 34-0400 Halovet Outlet Tube Mount for 22mm Vaporizers<br />
PY2 34-1067 Endcap for PY2 34-1246<br />
PY2 34-1068 Outlet Endcap for PY2 34-1246<br />
Anesthetic Key Fill Applicators<br />
To ensure leak free filling of your anesthetic vaporizer select the<br />
applicator suitable for your vaporizer.<br />
Order # Product<br />
PY2 34-0401 Isoflurane Anesthetic Key Fill Applicator<br />
PY2 34-0772 Halothane Anesthetic Key Fill Applicator<br />
PY2 34-1391 Sevoflurane Anesthetic Key Fill Applicator<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />
F45
ims <strong>anesthesia</strong><br />
Fluovac System, IMS Fluosorber<br />
and Accessories<br />
IMS Fluosorber<br />
Fluovac System PY2 34-0415<br />
The Fluosorber consists of a canister<br />
containing activated carbon, which<br />
absorbs anesthetic gas extremely<br />
efficiently.<br />
It is used with the Fluovac to scavenge<br />
anesthetic waste from the working<br />
environment, and is quickly and<br />
simply attached to the Fluovac unit.<br />
The Fluosorber’s capacity to scavenge<br />
is measured by weight: Simply<br />
pre-weigh canister and change once<br />
it has increased 200 grams. During<br />
manufacturing each Fluosorber is tested to ensure an air flow of 60 liters per<br />
minute with a flow resistance not exceeding 2.0 cmH 2O. When exhausted,<br />
the Fluosorber is sealed in the special bags provided and can then be<br />
completely incinerated. Supplied in cases of 6 canisters.<br />
Respiration<br />
ims <strong>anesthesia</strong><br />
Fluovac System<br />
• Absorbs anesthetic vapors from the work area,<br />
protecting personnel from exposure<br />
• Allows optimal access to the animal particularly<br />
important when carrying out close-up or micro<br />
surgery<br />
• A self-contained, portable unit requiring no extra<br />
ducting or ventilation<br />
• Three different size masks available<br />
• Incorporates a special double mask which supplies<br />
the anesthetic and scavenges excess vapors<br />
simultaneously<br />
• Requires minimal maintenance<br />
• Easy to use: simply connect to your vaporizer<br />
system and insert a Fluosorber canister<br />
• Each Fluovac is supplied with a size 1-Double mask<br />
The Fluovac Systems combines small animal <strong>anesthesia</strong> with operator<br />
safety. Fluosorber canisters must be ordered separately, see to the right.<br />
Specifications<br />
Overall Dimensions, 180 x 275 x 300 mm (7.1 x 10.8 x 11.8 in), case only<br />
H x W x D<br />
Weight (inc. Fluosorber) 8 kg (17.6 lbs)<br />
Weight (exc. Fluosorber) 7 kg (15.4 lbs)<br />
Power<br />
240 VAC, 50 Hz; 110 VAC, 60 Hz, 37 Watts<br />
IMPORTANT: The Fluovac must only be used with non-flammable gases<br />
Order # Product<br />
PY2 34-0387 Fluovac, 240 VAC, 50 Hz<br />
PY2 34-0388 Fluovac, 110 VAC, 60 Hz<br />
Specifications<br />
Active Canister Weight<br />
Exhausted Weight<br />
1200 g (2.65 lbs)<br />
1400 g (3.1 lbs)<br />
Order # Product<br />
PY2 34-0415 IMS Fluosorber, 6 canisters<br />
PY2 34-0392<br />
Fluovac Mask<br />
Support<br />
Order # Product<br />
PY2 34-0394 Fluovac Mask Support for Size 1 Mask<br />
PY2 34-0395 Fluovac Mask Support for Size 2 Mask<br />
PY2 34-0396 Fluovac Mask Support for Size 3 Mask<br />
Fluovac Exhaust<br />
Tube Mount<br />
The gas exhaust duct on the rear of<br />
the Fluovac unit can be fitted with<br />
a tube mount to vent exhaust gases<br />
such as nitrous oxide (Note: It is not<br />
necessary to vent if only anesthetic<br />
agent is used as the Fluovac with the Fluosorber canister, removes anesthetic<br />
gas from the atmosphere most effectively). Suitable tube for venting is the<br />
cuffed plastic tubing, see PY2 34-0426 on page F53.<br />
Order # Product<br />
PY2 34-0392 Fluovac Exhaust Tube Mount<br />
Fluovac<br />
Mask Support<br />
Designed to hold a Fluovac mask in<br />
position on a flat surface. This support<br />
minimizes the risk of movement<br />
between the animal and the mask.<br />
F46<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
Fluovac System<br />
ims <strong>anesthesia</strong><br />
PY2 34-0389 PY2 34-0391<br />
PY2 34-1379<br />
PY2 34-0393<br />
Order # Product<br />
PY2 34-0393 Gas Flow Directors<br />
PY2 34-0459<br />
Fluovac Masks<br />
Harvard Apparatus is pleased to<br />
introduce the new Fluovac Mouse<br />
Mask, a single arm coaxial mask<br />
for the delivery and scavenging of<br />
anesthetic gases utilizing the<br />
Fluovac System.<br />
Order # Product<br />
PY2 34-1379 Fluovac Mask Size 0.5 single arm (mice)<br />
PY2 34-0389 Fluovac Mask Size 1 dual arm (rat)<br />
PY2 34-0390 Fluovac Mask Size 2 single arm (G. Pig)<br />
PY2 34-0391 Fluovac Mask Size 3 single arm (rabbit)<br />
Gas Flow Directors<br />
An effective yet simple method of<br />
eliminating the Connector Set<br />
from the IMS Fluovac system.<br />
Directs the flow of gas to either or<br />
both double rodent mask simply<br />
by turning the knob.<br />
Directavalves<br />
Gas flow can be sent in one of two<br />
directions by simply turning a small<br />
valve on top of the assembly.<br />
Fluovac Isolator<br />
Valve<br />
A most useful addition to our gas<br />
scavenging range, the valve redirects<br />
gas from the FLUOVAC mask when<br />
out of use for short periods. The<br />
advantage is that neither the<br />
Vaporizer setting nor the flowmeter<br />
setting have to be altered when an animal is removed from the mask thus<br />
saving time having to reset the previous settings.<br />
Also, if the gas flow has inadvertently been set a little high then it could<br />
overcome the scavenging action at the mask when an animal is removed - the<br />
use of the valve prevents contamination of the area by stopping the gas<br />
reaching the mask.<br />
The valve is activated by the push/pull control knob to the indicated setting.<br />
In use the gas supply and scavenged gas flow through specially machined<br />
channels in the valve. In the isolation mode the gas flow from the vaporizer<br />
is directed into the scavenged gas flow while simultaneously opening a<br />
channel to outside air which is sucked into the mask by the scavenging effect<br />
thus also clearing traces of anesthetic gas from the mask.<br />
The units are easily fitted into existing masks by the user - full instructions<br />
are included. Please state the size of the mask to be modified as Size 1 has<br />
a smaller bore Crystaflex tube than 2 & 3.<br />
Order # Product<br />
PY2 34-0402 Fluovac Isolator Valve*<br />
*Note: This Valve is a registered design.<br />
Specifications<br />
Internal Diameter<br />
Length<br />
PY2 34-0402<br />
Fluovac Tube<br />
Restrainer<br />
Used for induction of <strong>anesthesia</strong> if<br />
the patient cannot be held at the<br />
Fluovac mask - the Size 1 mask end<br />
is simply plugged into the end of the<br />
unit which is then supplied with<br />
PY2 34-0457<br />
anesthetic gas and is also scavenged.<br />
The patient is kept up to the front of<br />
the tube with a holding bar. When the animal is anesthetized it is taken out<br />
of the tube, the mask is unplugged and the animal is positioned at the<br />
mask–a very quick and easy procedure.<br />
57 mm (2.24 in)<br />
Adjustable up to 200 mm (7.87 in)<br />
ims <strong>anesthesia</strong> Respiration<br />
Order #<br />
PY2 34-0459<br />
Product<br />
Directavalves<br />
Order #<br />
PY2 34-0457<br />
Product<br />
Fluovac Tube Restrainer<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />
F47
ims <strong>anesthesia</strong><br />
Anesthetizing Chambers & Table<br />
Fluovac Anesthetizing<br />
Chamber With Gas<br />
Scavenging System<br />
Respiration<br />
ims <strong>anesthesia</strong><br />
Fluovac Anesthetizing Chamber<br />
with Gas Scavenging System<br />
Further enhance the flexibility of your Fluovac system by the addition of a<br />
special anesthetizing chamber. No modifications to the existing Fluovac<br />
unit are necessary.<br />
The system provides a safe working environment for staff while minimizing<br />
stress to the animal.<br />
The crux of the system is the Directavalve, a valve which can control the flow<br />
of gases and vapors in either of two directions. Two Directavalves are used<br />
in the system. One is placed on the outlet tube mount of the Vaporizer, so that<br />
halothane can be directed to either the Fluovac masks or the anesthetizing<br />
chamber. The other is placed on the Fluosorber canister, so that Fluovac<br />
scavenges from the mask or chamber as required.<br />
The clear Perspex chamber has a 6mm inlet tube mount which enters the<br />
chamber under a false floor. Scavenging is via a tube mount with specially<br />
shaped air bleeds. These create a vortex in the chamber, optimizing the<br />
scavenging effect.<br />
Removal of the animal will cause some vapor to be released: this can be<br />
overcome by placing the chamber in a flow hood.<br />
Please note that there are two sizes available, the smaller designed is<br />
specifically for a single animals.<br />
NEW Portable Scavenged Anesthesia Table<br />
Harvard Apparatus have developed a simple easy to use portable scavenged<br />
anesthetic operating table for mice. Simply connect the anesthetic delivery<br />
tube to your anesthetic supply. Then connect the exhaust mount to your<br />
Fluovac scavenging system (22 mm bore scavenge tubing). This will give you<br />
an inexpensive, portable, down-draft operating table. Tables can also be<br />
created for Rats. Please ask for details.<br />
Order # Product<br />
PY2 34-1411 Scavenged Anesthesia Platform<br />
PY2 34-0909 22mm Bore Tubing to Connect to Fluovac<br />
Gas Scavenging Kit System Components<br />
Order # Product Qty.<br />
PY2 34-0399 Inlet Tube Mount 1<br />
PY2 34-0400 Outlet Tube Mount 1<br />
PY2 34-0422 6 mm Bore PVC Tubing x 1m Long 1<br />
PY2 34-0459 Directa Valves 2<br />
PY2 34-0909 22 mm Bore Tubing x 1m Long 1<br />
Plus Either<br />
PY2 34-0460 Large Anesthetizing Chamber Only 1<br />
or<br />
PY2 34-0462 Small Anesthetizing Chamber Only 1<br />
Order #<br />
PY2 34-0458<br />
PY2 34-0461<br />
Product<br />
Fluovac Anesthetizing Chamber with Gas Scavenging<br />
System, Large<br />
Fluovac Anesthetizing Chamber with Gas Scavenging<br />
System, Small<br />
PY2 34-0460<br />
Specifications<br />
Dimensions, H x W x D:<br />
Large Unit<br />
Small Unit<br />
Anesthetizing<br />
Chamber<br />
These anesthetizing chambers are<br />
available in two sizes. The smaller<br />
size was designed specifically for<br />
use with smaller species.<br />
200 x 200 x 305 mm (7.9 x 17.9 x 12 in)<br />
134 x 128 x 170 mm (5.3 x 5 x 6.7 in)<br />
Order # Product<br />
PY2 34-0460 Anesthetizing Chamber Large<br />
PY2 34-0462 Anesthetizing Chamber Small<br />
PY2 34-0462<br />
F48<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
ims <strong>anesthesia</strong><br />
Anesthetizing Chambers and Workstations<br />
Scavenged Anesthetizing Chamber<br />
For use in conjunction with the Fluovac. It is easy to use–simply plug a size<br />
one mask into the rear socket, turn on the Fluovac and gas supply.<br />
When the animal(s) are anesthetized the inner chamber slides forward<br />
allowing the gas supply to be diverted and the chamber scavenged. During<br />
this process fresh air is drawn into the inner chamber to help scavenge any<br />
residual anesthetic gas.<br />
The following sizes are the dimensions of the inner chamber only. Please<br />
note that there are two sizes available. The smaller is designed specifically<br />
for use with a single animal.<br />
PY2 34-0455 PY2 34-0456<br />
✐<br />
NOTE:<br />
This system is used when one chamber<br />
is sufficient and use of both Size 1 Masks are<br />
also required. If two chambers are required to<br />
give sufficient output and masks are not required<br />
then the use of the following system is suggested.<br />
Specifications<br />
Dimensions, H x W x D:<br />
Large Unit<br />
Small Unit<br />
110 x 160 x 260 mm (4.3 x 6.3 x 10.2 in)<br />
98 x 106 x 130 mm (3.9 x 4.2 x 5.1 in)<br />
Order # Product<br />
PY2 34-0455 Scavenged Anesthetizing Chamber, Large<br />
PY2 34-0456 Scavenged Anesthetizing Chamber, Small<br />
Custom Built Options<br />
With expertise in design and engineering, Harvard Apparatus Ltd has<br />
manufactured many items to our customer’s specification. Pictured below<br />
is a complete down draft, height adjustable mobile anesthetizing table. It<br />
has built in power supply, gas regulators, flowmeters and isoflourane<br />
vaporizer, high intensity cold light source, simple snap fit anesthetic mask<br />
connections, surgical tray connections and heated surgical board. This was<br />
developed to plug into a customer’s existing scavenging systems. The height<br />
adjustment is made with a hand held remote control and has 10 preset<br />
heights ensuring perfect operating conditions for each user.<br />
If you have a similar requirement please contact us with your requirements.<br />
ims <strong>anesthesia</strong> Respiration<br />
Order #<br />
PY2 34-1133<br />
Product<br />
Special Operating Table Plus Anesthesia<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />
F49
ims <strong>anesthesia</strong><br />
Pneumatic Fittings and CO 2 Chambers<br />
CO 2 Chambers<br />
with Dump Door<br />
An added option for CO 2 Chambers<br />
is to have a dump door fitted. This<br />
enables CO 2 to be cleared from the<br />
chamber without having to tip up<br />
the chamber and waiting, therefore<br />
saving time and effort.<br />
The chamber is easily and quickly opened and closed, and locked in place<br />
by means of a centrally placed knob. The side opening is below the false<br />
floor. Three chambers sizes are available.<br />
Specifications<br />
Dimensions, H x W x D:<br />
Large Chamber 305 x 305 x 455 mm (12 x 12 x 17.9 in)<br />
Medium Chamber 200 x 200 x 200 mm (7.9 x 7.9 x 7.9 in)<br />
Small Chamber 150 x 100 x 255 mm (5.9 x 3.9 x 10 in)<br />
Order # Product<br />
PY2 34-0434 CO 2<br />
Chamber with Dump Door, Large<br />
PY2 34-0435 CO 2<br />
Chamber with Dump Door, Medium<br />
PY2 34-0436 CO 2<br />
Chamber with Dump Door, Small<br />
Pneumatic Fittings<br />
Spares and/or upgrades can be made to existing anesthetic systems by use<br />
of pneumatic quick release fittings.<br />
Respiration<br />
ims <strong>anesthesia</strong><br />
PY2 34-0451 PY2 34-0452<br />
PY2 34-0454 PY2 34-0453<br />
Order #<br />
PY2 34-0451<br />
PY2 34-0452<br />
PY2 34-0453<br />
PY2 34-0454<br />
Product<br />
1/4" UNC Thread, Female Quick Release Fitting for Use<br />
on Chambers etc.<br />
Male Quick Release Fitting with Push in Fitting for<br />
6mm OD Pneumatic Tubing<br />
Coiled 6mm OD Tubing<br />
6mm OD Pneumatic Tubing, Natural Color, sold per meter<br />
Specifications<br />
Dimensions, H x W x D:<br />
Large Chamber<br />
Medium Chamber<br />
Small Chamber<br />
315 x 305 x 455 mm (12.4 x 12 x 17.9 in)<br />
210 x 200 x 305 mm (8.3 x 7.9 x 12 in)<br />
160 x 100 x 255 mm (6.3 x 3.9 x 10 in)<br />
PY2 34-0429 PY2 34-0430<br />
Anesthetic/CO 2<br />
Chambers<br />
These chambers have a 6 mm wall<br />
thickness and can be ordered in<br />
either white or clear Perspex. The<br />
lid is 10 mm thick clear Perspex and<br />
PY2 34-0431<br />
has a foam sealing strip.<br />
Inside, the chamber has a false perforated aluminum floor resting on nylon<br />
supports. Brass straight fittings are supplied as standard. The inlet is below<br />
the grill floor and outlet at top of opposite end.<br />
Three different sized chambers area available.<br />
Product PY2 34-0452 Quick Release Inlet (male fitting) is available<br />
separately. This fitting is for use with coiled pneumatic fitting systems.<br />
Order #<br />
PY2 34-0429<br />
PY2 34-0430<br />
PY2 34-0431<br />
PY2 72-1080<br />
PY2 72-3043<br />
✐<br />
NOTE:<br />
Product<br />
Anesthetic/CO 2<br />
Chamber, Large<br />
Anesthetic/CO 2<br />
Chamber, Medium<br />
Anesthetic/CO 2<br />
Chamber, Small<br />
Silicone Tubing 3/16" ID, 1/4" OD, 25 ft<br />
Male Endcap with Barb for 3/16" to 1/4" ID Tubing<br />
Product PY2 34-0452 Quick Release Inlet<br />
(male fitting) is available separately. This fitting<br />
is for use with coiled pneumatic fitting systems.<br />
F50<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
ims <strong>anesthesia</strong><br />
Flowmeters, Regulator Valves and Tube Mounts<br />
PY2 34-0404 PY2 34-0407<br />
PY2 34-0437<br />
PY2 34-0447<br />
PY2 34-0438 PY2 34-0439<br />
Veterinary Flowmeters for O 2<br />
and N 2<br />
O<br />
These are tapered, variable area flowmeters, for use with both oxygen and<br />
nitrous oxide. Flow is controlled by a needle valve operated by a simple<br />
control knob mounted on the front of the unit.<br />
Calibration of the oxygen flowmeter is 200cc/minute to 15 LPM, and of the<br />
nitrous oxide flowmeter 100cc/minute to 12 LPM. Tube mounts are included<br />
with each flowmeter.<br />
Low flow rates can be obtained with impressive accuracy. The Flowmeter<br />
Bench Stand is suitable for PY2 34-0403, PY2 34-0404, PY2 34-0405 and<br />
PY2 34-0406.<br />
Order # Product<br />
PY2 34-0403 Oxygen Veterinary Flowmeter<br />
PY2 34-0404 Nitrous Oxide Veterinary Flowmeter<br />
PY2 34-0407 Flowmeter Bench Stand<br />
Oxygen Flowmeter (Linear Scale)<br />
Covers range of 0 to 10LPM. It has a stainless steel needle valve with<br />
150mm tube. Tube mounts are included.<br />
Order # Product<br />
PY2 34-0405 Oxygen Flowmeter, Linear Scale<br />
PY2 34-0407 Flowmeter Bench Stand<br />
Regulator Valves<br />
All include tube mounts, 3/8 inch nut to 1/4 inch stem.<br />
Order # Product<br />
PY2 34-0438 Oxygen: Bull Nose Fitting, 5/8 inch BSP, 2 Gauge,<br />
Single Stage. To Fit Size F Cylinders<br />
PY2 34-0441 Oxygen: Side Entry, Pin Index, 2 Gauge, Single Stage.<br />
To Fit Size E Cylinders<br />
PY2 34-0439 Carbon Dioxide: 2 Gauge, Single Stage.<br />
To Fit Size F Cylinders<br />
PY2 34-0440 Carbon Dioxide: Side Entry, Pin Index. 2 Gauge,<br />
Single Stage. To Fit Size E Cylinders<br />
PY2 34-0437 Nitrous Oxide: 11/16 inch, 20 TPI Fitting. 2 Gauge,<br />
Single Stage. To Fit Size F Cylinders<br />
PY2 34-0442 Carbon Dioxide: Side Entry, Pin Index. 2 Gauge,<br />
Single Stage. To Fit Size E Cylinders<br />
PY2 34-0447 Replacement Washers for pin index regulators are also<br />
available. Metal with a rubber seal<br />
ims <strong>anesthesia</strong> Respiration<br />
PY2 34-0443<br />
Regulator Tube Mounts<br />
Replacements to fit any of the above. 3/8 inch<br />
nut to 1/4 inch stem.<br />
PY2 34-0406<br />
Carbon Dioxide Flowmeter (Linear Scale)<br />
Covers range of 0-12 LPM. Stainless steel needle valve with 150 mm tube.<br />
Again, tube mounts are included.<br />
Order #<br />
PY2 34-0443<br />
Product<br />
Regulator Tube Mounts<br />
Order #<br />
PY2 34-0406<br />
PY2 34-0407<br />
Product<br />
Carbon Dioxide Flowmeter, Linear Scale<br />
Flowmeter Bench Stand<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />
F51
ims <strong>anesthesia</strong><br />
Low Oxygen Warning Alarm,<br />
Oxygen Flush Control and Tubing<br />
PY2 34-0423<br />
PY2 34-0425<br />
PY2 34-0426<br />
PY2 34-0421<br />
PY2 34-0425<br />
PY2 34-0424<br />
Respiration<br />
ims <strong>anesthesia</strong><br />
Low Oxygen Warning Alarm<br />
A low warning device ensuring safety and continuity during <strong>anesthesia</strong><br />
techniques. Simply connects in series between Regulator and Flowmeter and<br />
emits a loud whistle when Oxygen drops to a low level in the Cylinder.<br />
This is activated between 2.5 - 2 bar in a decreasing concentration leaving ample<br />
time for the operator to change the cylinder with the minimum disruption<br />
in procedure.<br />
Order # Product<br />
PY2 34-0473 Low Oxygen Warning Alarm<br />
PY2 34-0420<br />
Order # Product<br />
PY2 34-0420 Neoprene Antistatic Tubing<br />
Neoprene Antistatic<br />
Tubing<br />
Black (with yellow line). It measures<br />
6mm ID x 13mm OD and is supplied<br />
in 1 meter length.<br />
Oxygen Flush Control<br />
Incorporated into a anesthetic unit to supply oxygen directly from source to<br />
the animal, or for emergency use plus an aid to recovery.<br />
Order # Product<br />
PY2 34-0474 Oxygen Flush Control<br />
High Pressure<br />
Tubing<br />
This High Pressure Tubing is black<br />
PY2 34-0423<br />
and measures 6mm ID x 13mm OD.<br />
It is supplied in 1 meter lengths. For use with CO 2<br />
or compressed air.<br />
PY2 34-0421<br />
Order # Product<br />
PY2 34-0421 Silicone Tubing<br />
PY2 34-0422<br />
Silicone Tubing<br />
Used as the inner supply tube<br />
for Fluovac masks. It measures<br />
6mm ID x 10mm OD and is<br />
supplied in 1 meter length.<br />
PVC Tubing<br />
This tubing is available in 2 sizes<br />
and is supplied in 1 meter lengths.<br />
Order #<br />
PY2 34-0423<br />
Product<br />
High Pressure Tubing<br />
Order #<br />
PY2 34-0422<br />
PY2 34-0782<br />
Product<br />
PVC Tubing, 6mm ID x 9mm OD<br />
PVC Tubing, 8mm ID x 11mm OD<br />
F52<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
ims <strong>anesthesia</strong><br />
Tubing, Replacement Tubing, Y Pieces<br />
and Tube Clamps<br />
Anti-Static High Pressure Tubing<br />
Anti-Static High<br />
Pressure Tubing<br />
This anti-static tubing measures<br />
6 mm ID x 13 mm OD and is<br />
supplied in 1 meter lengths. It is<br />
available in two colors.<br />
PY2 34-0940<br />
Y Pieces<br />
These y-connectors are constructed<br />
of white polypropylene and measure<br />
6.7 mm ID x 9 mm OD. Supplied 10<br />
per package.<br />
Order #<br />
PY2 34-0424<br />
PY2 34-0425<br />
Product<br />
Anti-Static High Pressure Tubing, Oxygen<br />
(White in Color)<br />
Anti-Static High Pressure Tubing, Nitrous Oxide<br />
(Blue in Color)<br />
Order # Product<br />
PY2 34-0940 Y Pieces, pkg. of 10<br />
PY2 34-0426<br />
Order # Product<br />
PY2 34-0426 Plastic Tubing, 22 mm Taper, 10 meters<br />
Corrugated Plastic<br />
Tubing<br />
Corrugated tubing to fit all 22 mm<br />
tapered male tube mounts (including<br />
Directavlaves, Halovets etc.). Supplied<br />
as a continuous 10 meter length,<br />
which can be cut into 38 cm sections<br />
each end having a 22 mm taper.<br />
Order # Product<br />
PY2 34-0941 Tube Clamps, pkg. of 10<br />
Tube Clamps<br />
The Tube Clamps have a knurled<br />
adjuster screw and hinged side<br />
plate. Supplied 10 per package.<br />
ims <strong>anesthesia</strong> Respiration<br />
Fluovac Mask<br />
Replacement<br />
Tubing<br />
Fluovac Mask Replacement Tubing<br />
Order # Product<br />
PY2 34-0427 Fluovac Mask Replacement Tubing, Size 1,<br />
27 mm OD x 1 m long<br />
PY2 34-0428 Fluovac Mask Replacement Tubing, Size 2 & 3,<br />
30 mm OD x 1 m long<br />
Convert from a Gas Bottle<br />
to a Piped Gas Supply<br />
Harvard Apparatus have developed a simple connector to convert any<br />
anesthetic trolley or bracket system with pin index regulator to be able to<br />
receive gas supply from a wall mounted piped gas supply. Simply connect<br />
one end to your wall mounted supply and then insert the specially designed<br />
pin index block into the pin index socket on your regulator. The length of<br />
high pressure hose supplied is 2 m (other sizes and gasses can be custom<br />
made if necessary).<br />
Hose<br />
Order # Supplied Product<br />
PY2 34-1064 2 m (6.6 ft) Hose to Pin Index for Oxygen<br />
PY2 34-1065 2 m (6.6 ft) Hose to Pin Index for Nitrous Oxide<br />
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com<br />