PosiTector ®<br />

<strong>Dew</strong> <strong>Point</strong> <strong>Meter</strong><br />

NEW NEW<br />

Measures and records<br />

climatic parameters<br />

including: Air temperature,<br />

surface temperature, relative<br />

humidity, dew point temperature<br />

and difference between surface<br />

and dew point temperatures.<br />

Ideal for surface preparation<br />

as required by ISO 8502-4.<br />

Ideal<br />

for Indoor<br />

& Outdoor<br />

Use<br />

Separate probe<br />

for greater accessibility<br />

and versatility... or clip-on<br />

for one-hand operation.


<strong>Dew</strong> <strong>Point</strong> <strong>Meter</strong><br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Simplicity<br />

Large, easy-to-read, graphics LCD with multilingual support<br />

Two-button menu-driven user interface<br />

Quick operating instructions on back of each instrument<br />

No need to consult <strong>com</strong>plex tables or use a slide rule calculator<br />

Durability<br />

Rugged, indoor/outdoor instrument is solvent, acid, oil,<br />

water and dust resistant<br />

Supplied with genuine leather pouch and shoulder strap<br />

One year warranty<br />

Accuracy<br />

Fast response precision sensors provide accurate,<br />

repeatable readings with high reliability and long term stability<br />

Factory calibrated against international standards<br />

Certificate of Calibration included<br />

Quick Recovery Feature: built-in heating element removes<br />

condensation from probe... always a factor when any<br />

instrument is moved from a cold to a warm environment<br />

Conforms to ISO 8502-4<br />

Versatility<br />

Celsius / Fahrenheit switchable<br />

Audio & visual alarm indicates when climactic conditions<br />

are unsuitable for painting<br />

Backglow display for dim or dark environments<br />

Internal memory stores up to 1000 datasets<br />

Data Logger Mode: automatically records datasets at<br />

user selected time intervals. Ideal for unattended<br />

operation to record climactic trends<br />

<br />

Options<br />

Low cost, battery operated infrared<br />

printer receives data from the<br />

instrument without connectors<br />

or cables<br />

Sample<br />

printout<br />

<strong>Dew</strong> <strong>Point</strong> <strong>Meter</strong><br />

S/N 55123<br />

------------------<br />

n1<br />

2002/04/22 9:15:52<br />

RH = 29.6 %<br />

Ta = 23.5<br />

Ts = 22.8<br />

Td = 4.7 ∆ = 18.1 ˚<br />

˚<br />

n2<br />

2002/04/22 18:2<br />

RH = 76.2 %<br />

Ta = 37.0<br />

Ts = 41.4<br />

Td = 32.2<br />

Ts-Td = 9.2 ˚<br />

Stainless steel<br />

wear resistant<br />

probe tip<br />

for durability<br />

Sliding cover<br />

protects sensors<br />

when not in use<br />

Remove the probe<br />

to accurately spot<br />

check hard-toreach<br />

areas<br />

Soft rubber grip<br />

for easy handling<br />

Attachable clip<br />

allows for onehand<br />

operation<br />

Example of Display<br />

Air temperature<br />

<strong>Dew</strong> <strong>Point</strong><br />

temperature<br />

Relative Humidity<br />

Easy-to-read. Press the minus<br />

button to cycle through large<br />

views of all five measurements.<br />

All values constantly updated.<br />

Press one button to hold all<br />

values for closer analysis or<br />

to store them in memory.<br />

DATASET<br />

MEASURES<br />

Ta – air temperature<br />

Ts – surface temperature<br />

RH – relative humidity<br />

Built-in K-type thermocouple<br />

surface temperature probe<br />

White sensor housing reduces<br />

the effect of direct sunlight<br />

Reversing<br />

probe and<br />

unique flip<br />

display enable<br />

right-side-up<br />

viewing.<br />

Indicator light:<br />

ideal in noisy<br />

environments<br />

to confirm<br />

readings have<br />

been recorded<br />

Surface temperature<br />

Surface minus dew<br />

point temperature.<br />

Determines probability<br />

of condensation.<br />

A critical value when<br />

<strong>com</strong>plying with ISO<br />

procedures!<br />

<br />

PosiSoft ® for Windows ® analysis software<br />

• Allows entry of notes and annotations<br />

• Prints and displays basic Charts and Histograms<br />

• Exports to a document or spreadsheet<br />

• Includes serial cable for printer or <strong>com</strong>puter hook-up<br />

GAGE COMES COMPLETE with 2 AA batteries, instructions, leather pouch,<br />

attachable clamp for one hand operation, built-in infrared port for printing to a<br />

wireless IR printer, Certificate of Calibration traceable to NIST, one year warranty.<br />

Body: 147 x 61 x 25mm (5.8" x2.4" x 1"). Probe: 220x20mm (8.7" x 0.8").<br />

Weight: 170g (6oz) without batteries.<br />

CALCULATES<br />

Td – dew point temperature<br />

∆ – the difference between<br />

surface and dew point<br />

temperatures<br />

Specifications<br />

Surface<br />

Temperature<br />

Air Temperature<br />

Humidity<br />

Range<br />

–40˚ to 80˚ C<br />

80˚ to 190˚ C<br />

–40˚ to 175˚ F<br />

175˚ to 375˚ F<br />

–40˚ to 80˚ C<br />

–40˚ to 175˚ F<br />

0 to 100%<br />

Accuracy<br />

±0.5˚ C<br />

±1.5˚ C<br />

±1˚ F<br />

±3˚ F<br />

±0.5˚ C<br />

±1˚ F<br />

±3 %<br />

Resolution<br />

0.1˚ C<br />

0.1˚ F<br />

0.1˚ C<br />

0.1˚ F<br />

0.1 %<br />

Technical Data subject to change without notice. <strong>QUALITEST</strong> USA LC - www.<strong>WorldofTest</strong>.<strong>com</strong> - 1.877.884.TEST - info@qualitest-inc.<strong>com</strong>