13.11.2012 Views

PowerLogic PowerView v2.0 software

PowerLogic PowerView v2.0 software

PowerLogic PowerView v2.0 software

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>PowerLogic</strong> <strong>PowerView</strong><br />

<strong>v2.0</strong> <strong>software</strong>


<strong>PowerLogic</strong> <strong>PowerView</strong> <strong>v2.0</strong><br />

New native support for devices<br />

Software updates<br />

New PDI tool (PMC usage)<br />

Target availability is October 2008.<br />

Schneider Electric - North American Operating Division<br />

2


Supported Devices<br />

The list of Supported Devices are:<br />

Power Meter 210<br />

Power Meter 500<br />

Power Meter 710,750<br />

Power Meter 810, 820, 850, 870<br />

Enercept<br />

ION 6200<br />

– M22, M2222 and M26 extended I/O modules<br />

Micrologic Trip Units Types P, H and A<br />

Maximum number of Devices:<br />

The maximum number of devices for this <strong>software</strong> application is 32.<br />

Schneider Electric - North American Operating Division<br />

3


Device Communications to devices<br />

Device Connections<br />

Automatic Detection (Auto discovery of networked devices)<br />

Software polls the network for supported devices<br />

User may “speed up” the detection process with scan options<br />

Devices are automatically named but can be re-configured by user<br />

Manual connections<br />

End users will have the option to manually add and delete device connections.<br />

Supports Ethernet gateways, including EGX models and PM8ECC<br />

Communications<br />

Supports Ethernet gateways, including EGX models and PM8ECC<br />

Devices with communication issues are highlighted in red<br />

Schneider Electric - North American Operating Division<br />

4


Auto Detection of Devices<br />

Schneider Electric - North American Operating Division<br />

5


Selective Scan Option<br />

Schneider Electric - North American Operating Division<br />

6


Data Logging<br />

Onboard Data Logging:<br />

The Power Meter 800 (PM800) family will perform onboard data logging<br />

The PM800 onboard logging interval is set in PMCU. <strong>PowerView</strong> Software will<br />

upload at regular 2 hour intervals automatically.<br />

PC-based Data Logging:<br />

The Power Meter 210, Power Meter 710 & 750, and Micrologic Trip Units A, P<br />

and H will perform PC-based data logging.<br />

The PC-based data logging interval default is 15 minutes.<br />

The PC-based data logging interval can be changed by the end user.<br />

The measurements that are PC based data logged cannot be modified.<br />

Quantities (measurements) Logged:<br />

Current<br />

Voltage<br />

Power<br />

power factor<br />

energy,<br />

demand power<br />

demand current<br />

total harmonic distortion (THD).<br />

Schneider Electric - North American Operating Division<br />

7


Database Management<br />

Database Backups:<br />

The option to backup the database will be available.<br />

Database Restores:<br />

The option to restore the database will be available.<br />

Historical Database Management:<br />

The Historical database will be maintained below 2.9 GB in size.<br />

Data will be deleted from the Historical database as first in – first out<br />

(FIFO) to prevent growth over 2.9GB.<br />

Deleted Historical data is not retained.<br />

Schneider Electric - North American Operating Division<br />

8


Real Time Display – Summary View<br />

Schneider Electric - North American Operating Division<br />

9


Report Builder<br />

Basic Queries:<br />

Device(s) + Measurement(s)+ time range= Output (trends, charts, tables)<br />

Both PC and Onboard (PM8’s) data available in database.<br />

Pre-configured Queries:<br />

Focused on providing end user with historical information on their Electrical Energy<br />

usage and power demand.<br />

Energy usage for last day, week, month<br />

Energy TOU (Time of Use) or Energy Bands outputs<br />

Support for Time of Use Metering includes.<br />

defining up to 3 schedules<br />

Each Schedule can contain<br />

-> up to 10 periods (bands) for energy accumulation<br />

-> Supports weekends, special days, holidays<br />

Reports Viewer:<br />

End user will be expected to have Microsoft Excel to view reports.<br />

All costing and other calculations (eg. Terrifications, rates) can be done manually by<br />

the customer in Excel.<br />

Schneider Electric - North American Operating Division<br />

10


General Report Example<br />

Schneider Electric - North American Operating Division<br />

11


Report Builder<br />

Schneider Electric - North American Operating Division<br />

12


Export the Data<br />

Schneider Electric - North American Operating Division<br />

13


Time of Use Setup<br />

Schneider Electric - North American Operating Division<br />

14


Time of Use Setup<br />

Schneider Electric - North American Operating Division<br />

15


Time of Use Setup<br />

Schneider Electric - North American Operating Division<br />

16


Time of Use Setup<br />

Schneider Electric - North American Operating Division<br />

17


Time of Use Setup<br />

Schneider Electric - North American Operating Division<br />

18


Appendix A – Data Logging per Device<br />

Schneider Electric - North American Operating Division<br />

19


Questions<br />

?<br />

Schneider Electric - North American Operating Division<br />

20

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!