EC-DECLARATION OF CONFORMITY - Metaloterm
EC-DECLARATION OF CONFORMITY - Metaloterm
EC-DECLARATION OF CONFORMITY - Metaloterm
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
www.metaloterm.com<br />
<strong>EC</strong>-Declaration of conformity | Ontop B.V. EN<br />
MEtAlOtErM ® UE<br />
<strong>EC</strong>-D<strong>EC</strong>LARATION <strong>OF</strong> <strong>CONFORMITY</strong><br />
Issued in accordance with the Construction Products Directive 89/106/E<strong>EC</strong><br />
Product: twin walled stainless steel system chimney products with air gap<br />
System <strong>Metaloterm</strong> ® UE<br />
Manufacturer: Ontop B.V.<br />
Oude Veerseweg 23<br />
4332 SH Middelburg<br />
the Netherlands<br />
Place of production: Middelburg - the Netherlands<br />
We declare that for the product mentioned above all provisions concerning EN 1856-1 have been applied and that it carries the respective<br />
CE marking conform Annex ZA.<br />
For the evaluation of conformity the tasks mentioned in table ZA.4 have been accomplished.<br />
the certification of the factory production control is performed by:<br />
the factory production control certificate number:<br />
is issued on 2004-05-27.<br />
Kiwa Nederland BV<br />
P.O. Box 137,<br />
7300 AC Apeldoorn<br />
the Netherlands<br />
0063-CPD-6308<br />
Middelburg, 2011-07-01 rogier Sander<br />
Director of Operations<br />
Page 1 / 6<br />
0063<br />
UEconform_EN_A_2011_08
Marking of accompanying documents to EN 1856–1, annex ZA tabel ZA.2<br />
www.metaloterm.com<br />
<strong>EC</strong>-Declaration of conformity | Ontop B.V. EN<br />
MEtAlOtErM ® UE<br />
Metal system- EN 1856-1 t200 P1 W V2 l50050 O25 twin wall chimney system with air gap<br />
chimney section EN 1856-1 t250 N1 W V2 l50050 O25 thickness of 7,5 mm<br />
Flow resistance<br />
Mean value of roughness: 1 mm<br />
Thermal resistance<br />
0,15 m 2 K/W<br />
at designation temperature<br />
Flexural strength<br />
tensile strength: 0 m<br />
Non-vertical installation: see website<br />
Wind load: free standing height above last support: see website<br />
Maximum spacing of lateral supports: see website<br />
Freeze-thaw resistance: Yes<br />
Productdescription<br />
Standard number<br />
temperature level<br />
Page 2 / 6<br />
Pressure level (N: negative pressure, P: positive pressure,<br />
H: High positive pressure)<br />
Condensate resistance (W: wet / D: dry)<br />
Corrosions-resistance class and flueliner specification<br />
Soot fire resistance (G: yes / O: no)<br />
and distance to combustible material (in mm).<br />
UEconform_EN_A_2011_08
No. Paragraph<br />
according to<br />
EN 1856-1<br />
www.metaloterm.com<br />
Characteristics and<br />
prestations according to<br />
EN 1856-1<br />
1.0 Par. 5.2 Nominal dimensions (mm): 80, 100, 130, 150, 180, 200,<br />
250 mm<br />
2.0 Par. 4 and 5<br />
Par. 6.7.2<br />
3.0 Par. 4 and 5<br />
Par. 6.7.2<br />
Material inner liner<br />
Quality:<br />
Nominal thickness<br />
(min. thickness)<br />
Material outer wall<br />
Quality:<br />
Nominal thickness<br />
(min. thickness)<br />
<strong>EC</strong>-Declaration of conformity | Ontop B.V. EN<br />
MEtAlOtErM ® UE<br />
Results / Class Document Additionele<br />
information<br />
l50040<br />
1.4404 (316l)<br />
0,40 mm<br />
(0,36 mm)<br />
tolerances to NEN-EN 10259<br />
l20040<br />
1.4301 (304)<br />
0,40 mm<br />
(0,45 mm)<br />
tolerances to NEN-EN 10259<br />
Page 3 / 6<br />
Manufacturers declaration Sizes see Product<br />
Catalogue<br />
Manufacturers declaration<br />
Manufacturers declaration<br />
4.0 Par. 4 and 5 Insulation: 7,5 mm luchtspouw Manufacturers declaration<br />
5.0 Par. 6.7.4 Sealant t200 P1 W: Shore 55 tÜV: A-1472-00/05<br />
6.0 Par. 6.2.1 Compressive strength Chimney height, dimensions and 08-N01-200206<br />
weight support: See website PQ07003-001<br />
PQ07003-002<br />
7.0 Par. 6.2.2 tensile strength 0 m 08-D03-010206<br />
8.0 Par. 6.2.3.2 Wind load Chimney height, dimensions and<br />
load bearing data: See website<br />
9.0 Par. 6.2.3.1 Maximum deflection:<br />
Maximum length of the slope:<br />
90°<br />
1,5 m<br />
See website<br />
08-N05-260905 Product Catalogue<br />
and website<br />
08-N04-010206 See website<br />
UEconform_EN_A_2011_08
No. Paragraph<br />
according to<br />
EN 1856-1<br />
www.metaloterm.com<br />
Characteristics and<br />
prestations according to<br />
EN 1856-1<br />
10.0 Par. 6.5 Gas tightness P1<br />
N1<br />
11.0 Par. 6.3 and<br />
6.4<br />
Distance to combustible<br />
materials, class t200/250 and<br />
soot fire resistance<br />
<strong>EC</strong>-Declaration of conformity | Ontop B.V. EN<br />
MEtAlOtErM ® UE<br />
Results / Class Document Additionele<br />
information<br />
tÜV:<br />
P1: A-1386-00/05<br />
N1: 08-N07-170209<br />
N1: 08-N35-130109<br />
ø 80-250 mm: 25 mm t200: tÜV A-1386-00/05<br />
t250: 08-N35-130109<br />
12.0 Par. 6.6.2 Accidental human contact Protection against accidental<br />
human contact in public areas<br />
to be fitted, in case outer skin<br />
temperature > 70°<br />
tÜV: A1386-00/05<br />
13.0 Par. 6.6.3 thermal resistance 0,15 m2K/W Istituto Giordano:<br />
rapporto di prova 97363<br />
14.0 Par. 6.6.5<br />
and 6.6.4<br />
Condensate resistance Yes, when W tÜV A-1386-00/05<br />
15.0 Par. 6.6.6 resistance against rainwater<br />
penetration<br />
Yes tÜV A-1386-00/05<br />
16.0 Par. 6.6.7.1 Mean value of roughness r = 1 mm EN 13384-1<br />
(table 4)<br />
17.0 Par. 6.6.7.2 resistance of chimney fittings EN 13384-1<br />
(table 8)<br />
18.0 Par. 6.7.1 Corrosion resistance V2 tÜV: A-1386-00/05<br />
19.0 Par. 6.7.3 Freeze-thaw resistance Yes EN 1856-1<br />
Page 4 / 6<br />
UEconform_EN_A_2011_08
No. Paragraph<br />
according to<br />
EN 1856-1<br />
www.metaloterm.com<br />
Characteristics and<br />
prestations according to<br />
EN 1856-1<br />
<strong>EC</strong>-Declaration of conformity | Ontop B.V. EN<br />
MEtAlOtErM ® UE<br />
Results / Class Document Additionele<br />
information<br />
20.0 typical installation drawings Manufacturers declaration Productcatalogus,<br />
see website<br />
21.0 Method of joining the<br />
components<br />
22.0 Method of installing sections<br />
or fittings, included supports<br />
and accessories<br />
Manufacturers declaration Mounting<br />
instructions<br />
Manufacturers declaration Mounting<br />
instructions,<br />
see website<br />
23.0 Direction of flow Manufacturers declaration Mounting<br />
instructions<br />
24.0 Storage instructions No corrosive atmosphere Manufacturers declaration<br />
25.0 Method of application of any<br />
required sealant<br />
26.0 Minimum distance from the<br />
chimney outer surface to the<br />
inner surface of the enclosure<br />
27.0 Positioning of clean-out and<br />
inspection openings<br />
28.0 Installation of chimney plate<br />
to the chimney, cladding or<br />
enclosure<br />
29.0 Enclosure/cladding<br />
specifications<br />
30.0 Cleaning methods or<br />
-instruments<br />
31.0 recommendations on<br />
condensate drainage<br />
Manufacturers declaration Mounting<br />
instructions<br />
National standards<br />
National standards<br />
Yes to EN 1856-1<br />
Only non-combustible enclosures Manufacturers declaration<br />
No cleaning instruments made of<br />
black steel, only stainless steel or<br />
plastic<br />
n/a<br />
Manufacturers declaration<br />
Page 5 / 6<br />
UEconform_EN_A_2011_08
CE–marking on the packaging (Annex ZA 3)<br />
Example of sticker which will be put on each packaging:<br />
the following chimney plate shall be put on the chimney or the enclosure:<br />
www.metaloterm.com<br />
<strong>EC</strong>-Declaration of conformity | Ontop B.V. EN<br />
MEtAlOtErM ® UE<br />
Page 6 / 6<br />
UEconform_EN_A_2011_08