You can change the setting of a function indicated by during operation.<br />

You should stop operation to change the setting of other functions.<br />

13-20<br />

PG LES VF SM<br />

a25 519h M2-R2 correction coef. 2 0.000 to 5.000 4 o o x o o x x o<br />

a26 51Ah M2-R2 correction coef. 3 0.010 to 5.000 4 o o x o o x x o<br />

a27 51Bh M2-Exciting correction<br />

coef.<br />

0.000 to 5.000 4 o o x o o x x o<br />

a28 51Ch M2-ACR-P gain 0.1 to 1.0 to 20.0 2 o o x o o x x o<br />

a29 51Dh M2-ACR I-gain 0.5 to 1.0 to 100.0 ms 2 o o x o o x x o<br />

a30 51Eh M2-PG pulses 100 to 1024 to 60000 0 o o x o x x x o<br />

a31 51Fh M2-thermistor<br />

selection<br />

a32 520h M2-Electronic<br />

thermal overload<br />

relay (selection)<br />

a33 521h M2-Electronic thermal<br />

overload relay (Level)<br />

a34 522h M2-Electronic thermal<br />

overload relay (Thermal<br />

0 to 1 to 3<br />

0 : No use thermistor<br />

1 : NTC thermistor<br />

2 : PTC thermistor<br />

3 : Ai (M-TMP)<br />

Please do the protection level setting of the motor<br />

at E30-E37.<br />

M2-Electronic thermal 0 to 2<br />

overload relay (Selection) The motor overheating protection operates by using<br />

NTC thermistor with the motor only for VG. In this<br />

case, please make setting a Electronic thermal<br />

"Inactive".<br />

0 : Inactive<br />

1 : Active (for standard motor, self-cooling fan)<br />

2 : Active (for inverter motor, separate cooling fan)<br />

a35 523h E5 h M3-Rated capacity<br />

time constant)<br />

M3-Rated capacity 0.00 to 500.00kW at F60=0<br />

0.00 to 600.00HP at F60=1<br />

a36 524h E6 h M3-Rated current 0.01 to 99.99A<br />

100.0 to 999.9A<br />

1000 to 2000A<br />

84 o o x o o x x o<br />

85 o o x o o x x o<br />

0.01 to 99.99A<br />

100.0 to 999.9A<br />

1000 to 2000A<br />

13 o o x o o x x o<br />

0.5 to 75.0 min 2 o o x o o x x o<br />

3 o o x x x o x x<br />

13 o o x x x o x x<br />

a37 525h E7 h M3-Rated voltage 80 to 999 V 0 o o x x x o x x<br />

a38 526h E8 h M3-Maximum voltage 80 to 999 V 0 o o x x x o x x<br />

a39 527h E9 h M3-Rated speed 50 to 1500 to 24000 r/min 0 o o x x x o x x<br />

a40 528h EA h M3-Maximum speed 50 to 1500 to 24000 r/min 0 o o x x x o x x<br />

a41 529h EB h M3-Poles 2 to 4 to 12 (poles) 1 o o x x x o x x<br />

a42 52Ah EC h M3-%R1 0.00 to 30.00 % 3 o o x x x o x x<br />

a43 52Bh ED h M3-%X 0.00 to 30.00 % 3 o o x x x o x x<br />

a44 52Ch EE h M3-Exciting current 0.01 to 99.99A<br />

100.0 to 999.9A<br />

1000 to 2000A<br />

13 o o x x x o x x<br />

a45 52Dh EF h M3-Slip compensation<br />

control<br />

-20.000 to 0.000 to 5.000 Hz 8 o o x x x o x x<br />

a46 52Eh F0 h M3-Torque boost 0.0 to 20.0<br />

0.0 : Automatic torque boost (for CT load)<br />

0.1 to 0.9 : Manual torque boost (for Square torque<br />

load)<br />

1.0 to 1.9 : Manual torque boost (for VT load)<br />

2.0 to 20.0 : Manual torque boost (for CT load)<br />

2 o o x x x o x x<br />

a47 52Fh F1 h M3-Thermistor<br />

selection<br />

a48 530h F2 h M3-Electronic<br />

thermal overload<br />

relay (selection)<br />

Function name Function directory name<br />

a49 531h F3 h M3-Electronic thermal<br />

overload relay (Level)<br />

a50 532h F4 h M3-Electronic thermal<br />

overload relay (Thermal<br />

time constant)<br />

0 to 1 to 3<br />

0 : No use thermistor<br />

1 : NTC thermistor<br />

2 : PTC thermistor<br />

3 : Ai (M-TMP)<br />

Please do the protection level setting of the motor<br />

at E30-E32.<br />

M3-Electronic thermal 0 to 2<br />

overload relay (Selection) 0 : Inactive (when using PTC thermistor)<br />

1 : Active (for standard motor, self-cooling fan)<br />

2 : Active (for inverter motor, separate-cooling fan)<br />

0.01 to 99.99A<br />

100.0 to 999.9A<br />

1000 to 2000A<br />

Setting range<br />

84 o o x x x o x x<br />

85 o o x x x o x x<br />

13 o o x x x o x x<br />

0.5 to 75.0 min 2 o o x x x o x x<br />

Type<br />

Copy<br />

Save all<br />

Initialization<br />

Control type: Available/<br />

Not available<br />

Lifting<br />

machine<br />

Underline indicates a factory setting.