FRENIC5000 VG5S FRENIC5000 VG7S<br />

Function<br />

codes<br />

Name<br />

Function<br />

codes<br />

Name<br />

143 Speed command through transmission S01 Speed command<br />

144 Action on T-Link error (Mode)<br />

o30 T-Link option (Action on<br />

(Action time)<br />

setting<br />

transmission error)<br />

145<br />

o31<br />

(Action time on<br />

transmission error)<br />

146 Standard built-in RS-485 address H31 RS-485 (Station address)<br />

147 Action on RS-485 error (Mode)<br />

H32 Action on RS-485 (Mode select on<br />

148<br />

149<br />

150<br />

(Action time)<br />

(No response error<br />

detection time)<br />

(Response interval)<br />

H33<br />

H38<br />

H39<br />

error Operation<br />

error)<br />

(Timer operating<br />

time)<br />

(No response<br />

error detection<br />

time)<br />

(Response<br />

interval)<br />

151<br />

X11 to X14 function<br />

(X11,X12) E10,E11<br />

X11 function selection, X12 function<br />

selection<br />

152<br />

selection<br />

(X13,X14) E12,E13<br />

X13 function selection, X14 function<br />

selection<br />

153<br />

154<br />

Y11 to Y13 function<br />

selection<br />

(Y11,Y12)<br />

(Y13)<br />

E20,E21<br />

E22<br />

Y11 function selection, Y12 function<br />

selection<br />

Y13 function selection<br />

155 Function selection of OPCII-VG5-DI o01,o02<br />

DIA function selection, DIB function<br />

selection<br />

156 BCD input speed o03,o04<br />

DIA BCD input setting, DIB BCD input<br />

setting<br />

157 Command pulse correction 1 o14 Command pulse correction 1<br />

158 Command pulse correction 2 o15 Command pulse correction 2<br />

159 APR gain o16 APR gain<br />

160 F/F gain o17 F/F gain<br />

161 Deviation excess range o18 Deviation excess range<br />

162 Deviation zero range o19 Deviation zero range<br />

170 Function block (171-197) selection −<br />

171 Motor selection P02 M1 motor selection<br />

172 PG pulse number P28 M1-PG pulse number<br />

173 NTC thermistor selection P30 M1 thermistor selection<br />

174 Motor ratings (Capacity)<br />

P03 M1 rated capacity<br />

175 (Voltage)<br />

F05 M1 rated voltage<br />

176 (Current)<br />

P04 M1 rated current<br />

177 (Base speed)<br />

F04 M1 rated speed<br />

178<br />

(No. of pole) P05 M1 number of pole<br />

179 Overload capability −<br />

180 Auto-tuning of motor (Protection)<br />

−<br />

181 characteristic<br />

(Operation) H01 Tuning operation selection<br />

182 Motor characteristic (%R1)<br />

P06 M1-%R1<br />

183 (%X)<br />

P07 M1-%X<br />

184 (Exciting current)<br />

P08 M1 exciting current<br />

185<br />

186<br />

187<br />

188<br />

189<br />

190<br />

191<br />

192<br />

193<br />

194<br />

195<br />

196<br />

(Torque current )<br />

(Slip on driving)<br />

(Slip on braking)<br />

(Iron loss coefficient 1)<br />

(Iron loss coefficient 2)<br />

(Iron loss coefficient 3)<br />

(Magnetic saturation<br />

coefficient 1)<br />

(Magnetic saturation<br />

coefficient 2)<br />

(Magnetic saturation<br />

coefficient 3)<br />

(Magnetic saturation<br />

coefficient 4)<br />

(Magnetic saturation<br />

coefficient 5)<br />

P09<br />

P10<br />

P11<br />

P12<br />

P13<br />

P14<br />

P15<br />

P16<br />

P17<br />

P18<br />

P19<br />

P20<br />

M1 torque current<br />

M1 slip on driving<br />

M1 slip on braking<br />

M1 iron loss coefficient 1<br />

M1 iron loss coefficient 2<br />

M1 iron loss coefficient 3<br />

M1 magnetic saturation coefficient 1<br />

M1 magnetic saturation coefficient 2<br />

M1 magnetic saturation coefficient 3<br />

M1 magnetic saturation coefficient 4<br />

M1 magnetic saturation coefficient 5<br />

M1 secondary time constant<br />

197<br />

(Secondary time<br />

constant)<br />

(Induced voltage<br />

coefficient )<br />

P21 M1 induced voltage coefficient<br />

200 Data protection F00 Data protection<br />