Technical Data MNK - Zenner
Technical Data MNK - Zenner
Technical Data MNK - Zenner
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Cold water meters Hot water meters Cartridge meters<br />
<strong>Technical</strong> data for the models <strong>MNK</strong>, <strong>MNK</strong>-N, <strong>MNK</strong>-I-N, <strong>MNK</strong>-RP, <strong>MNK</strong>-RP-N, <strong>MNK</strong>-RP-I-N, MTK, MTK-N, MTK-I-N<br />
Permanent flow Q3 m³/h 2,5 2,5 2,5 2,5 2,5 4 4 4 6,3<br />
Nominal diameter DN mm 15 15 15 25 20 20 25 20 25<br />
Inch 1/2 1/2 1/2 1 3/4 3/4 1 3/4 1<br />
Overall length without connectors L2 mm 110/115/145 165 170 175 190 220 175 190 175<br />
Overall length with connectors L1 mm 225/230/260 250 255 293 288 318 293 288 293<br />
Thread meter G x B D1 Inch 3/4 3/4 3/4 1 1/4 1 1 1 1/4 1 1 1/4<br />
Thread connector R x D2 Inch 1/2 1/2 1/2 1 3/4 3/4 1 3/4 1<br />
Measuring range horizontally ** Q3/Q1 Ratio R200H R200H R200H R200H R200H R200H R200H R200H R200H<br />
Measuring range vertically ** Q3/Q1 Ratio R50V R50V R50V R50V R50V R80V R80V R80V R80V<br />
Overload flow Q4 m³/h 3,125 3,125 3,125 3,125 3,125 5 5 5 7,875<br />
Minimum flow Q1 l/h 13 13 13 13 13 20 20 20 32<br />
Starting flow min l 4 4 4 5 5 5 5 5 5<br />
Display range min l 0,05 0,05 0,05 0,05 0,05 0,05 0,05 0,05 0,05<br />
max m³ 99.999 99.999 99.999 99.999 99.999 99.999 99.999 99.999 99.999<br />
Maximum temperature °C 30 30 30 30 30 30 30 30 30<br />
Operating pressure, max. PN bar 16 16 16 16 16 16 16 16 16<br />
Head loss at Q4 bar 0,6 0,6 0,6 0,3 0,6 1 1 1 0,6<br />
Pulse value L/Imp 10/100 10/100 10/100 10/100 10/100 10/100 10/100 10/100 10/100<br />
Height H1k* mm 120 120 120 120 115 120 120 115 120<br />
H1m* mm 125 125 125 125 120 125 125 120 125<br />
H2 mm 35 35 35 40 32 40 40 32 40<br />
H3 mm 15 15 15 15 15 15 15 15 15<br />
Width B mm 95 95 95 95 95 95 95 95 100<br />
Weight kg 1,4 1,4 1,4 1,7 1,8 1,9 1,8 1,8 1,8<br />
k* plastic glass<br />
m* mineral glass<br />
** Standard version R80H / R40V<br />
error %<br />
Q1 = minimum flow<br />
Q2 = transitional flow<br />
Q3 = permanent flow<br />
Q4 = Overload flow<br />
Q1<br />
Q2 Q3 Q4<br />
Typical accuracy curve<br />
12a
<strong>Technical</strong> data for the models <strong>MNK</strong>, <strong>MNK</strong>-N, <strong>MNK</strong>-I-N, <strong>MNK</strong>-RP, <strong>MNK</strong>-RP-N, <strong>MNK</strong>-RP-I-N, MTK, MTK-N, MTK-I-N<br />
Permanent flow Q3 m³/h 6,3 10 10 16 16 16 16<br />
Nominal diameter DN mm 25 25 32 40 50 50 50<br />
Inch 1 1 1 1/4 1 1/2 2 - -<br />
Overall length without connectors L2 mm 260 260 260 300 300 270 300<br />
Overall length with connectors L1 mm 378 378 378 438 438 - -<br />
Thread meter G x B D1 Inch 1 1/4 1 1/4 1 1/2 2 2 1/2 Flansch Flansch<br />
Thread connector R x D2 Inch 1 1 1 1/4 1 1/2 2 - -<br />
Measuring range horizontally ** Q3/Q1 Ratio R200H R200H R200H R200H R200H R200H R200H<br />
Measuring range vertically ** Q3/Q1 Ratio R80V R80V R80V R63V R63V R63V R63V<br />
Overload flow Q4 m³/h 7,875 12,5 12,5 20 20 20 20<br />
Minimum flow Q1 l/h 32 50 50 80 80 80 80<br />
Starting flow min l 10 10 10 20 20 20 20<br />
Display range min l 0,05 0,05 0,05 0,05 0,05 0,05 0,05<br />
max m³ 99.999 99.999 99.999 99.999 99.999 99.999 99.999<br />
Maximum temperature °C 30 30 30 30 30 30 30<br />
Operating pressure, max. PN bar 16 16 16 16 16 16 16<br />
Head loss at Q4 bar 0,6 1 1 1 1 1 1<br />
Pulse value L/Imp 10/100 10/100 10/100 10/100 10/100 10/100 10/100<br />
Height H1k* mm 140 140 140 - - - -<br />
H1m* mm 145 145 145 170 190 190 190<br />
H2 mm 50 50 50 60 75 75 75<br />
H3 mm 15 15 15 15 15 15 15<br />
Width B mm 100 100 100 131 165 165 165<br />
Weight kg 2,7 2,7 2,7 5,4 5,4 12,4 12,4<br />
k* plastic glass<br />
m* mineral glass<br />
** Standard version R80H / R40V<br />
pressure loss [bar]<br />
Q3 2,5 m³/h<br />
Q3 4,0 m³/h<br />
Q3 6,3 m³/h, 10 m³/h<br />
Q4 16<br />
flow rate [m³/h]<br />
Head loss curves<br />
13a