Caratteristiche tecniche<br />

<strong>Aptica</strong> <strong>Plus</strong> B<br />

External dimensions<br />

L. 443 x P. 545 x A. 254 mm<br />

Chamber dimensions<br />

Ø 156 x P. 251 mm<br />

Chamber capacity<br />

4,5 lt<br />

Net weight<br />

27 kg<br />

Max power consumption<br />

1.400 W<br />

Average power consumption<br />

600 W<br />

Supply voltage<br />

230 V - 50 Hz<br />

Air expulsion<br />

Vacuum pump<br />

Water recervoirs<br />

N. 2 recevoirs 3,5 lt each<br />

Automatic programs 7<br />

Drying cycle<br />

n<br />

Bowie & Dick test<br />

n<br />

Helix test<br />

n<br />

Vacuum test<br />

n<br />

Automatic switch off - Night cycle<br />

n<br />

Process Evaluation Control<br />

n<br />

Adaptive Heat<br />

n<br />

PC connection for USB Log and PC<br />

n<br />

Printed integrated/external optional<br />

n<br />

Volumetric doser<br />

n<br />

Water quality control<br />

n<br />

Bacterial filter - high filtration<br />

n<br />

Self diagnosis and trouble shooting<br />

n<br />

Cycle counter<br />

n<br />

Average sterilization time*<br />

12 - 20 min<br />

www.dentalx.it<br />

* The cycle time can change depending on load’s type and quantity, the pre-heating, the power voltage and the use and<br />

manteinance conditions.<br />

Programs Parameters Indication<br />

1 STERILIZATION 1 134 °C - 5 min<br />

For every load that could be<br />

submitted to 134 °C (Helix Test)<br />

B<br />

2 STERILIZATION 2 121 °C - 20 min<br />

For every load that could be<br />

submitted to 121 °C (Helix Test)<br />

B<br />

3 FLASH 134 °C - 4 min<br />

Rapid cycle for unwrapped surgical<br />

instruments<br />

S<br />

4 S1 Prion 134 °C - 18 min For Creutzfeld Jacob desease B<br />

S2 Heavy load 134 °C - 5 min For special loads B<br />

S3 Heavy load 121 °C - 20 min For special loads B<br />

S4 BSE Selected by the operator Depends by the selected parameters<br />

Bowie & Dick 134 °C - 3,5 min<br />

Vacuum Test 20 min<br />

Dental X reserves the right to make changes to the specifications illustrated.<br />

3YEARS<br />

WARRANTY<br />

dentalX<br />

0120<br />