Product Specifications Nomenclature A 1 P 2 H 3 15 4,5 36 6,7 M 8 4 9 1 10 A 11 * 12 Brand Engineering A <strong>Amana</strong> ® Brand Minor Revision Product Category Engineering P Packaged Unit Major Revision Type Voltage Designator C Air Conditioner 1 208-230/1/60 H Heat Pump 3 208-230/3/60 4 460/3/60 Efficiency Refrigerant 13 13 SEER 2 R-22 15 15 SEER 4 R-410A Nominal Capacity Configuration 24 2 Tons 48 4 Tons H Horizontal 36 3 Tons 60 5 Tons M Multi-position 2 www.amana-hac.com SS-<strong>APH15M</strong>
Product Specifications Specifications APH15 24M41C* APH15 30M41C* APH15 36M41C* APH15 43M41C* APH15 49M41C* APH15 60M41C* Cooling Capacity Total BTU/h 24,000 29,000 35,400 40,000 46,000 55,500 Sensible BTU/h 18,000 22,200 26,700 28,000 31,000 39,300 SEER / EER 15.0/ 12.0 14.5/ 11.5 14.5/ 12 15.0/ 12.0 15.0/ 11.7 14.0/ 10.2 Decibels 76 76 76 78 78 78 AHRI #s 6710589 6710590 6710591 6710592 6710593 6710594 Heating Capacity BTU/h (47°F) 23,400 27,400 35,400 39,000 45,500 56,000 C.O.P (47°F) 3.6 3.5 3.4 3.7 3.6 3.4 BUT/h (17°F) 12,400 15,200 18,600 22,000 25,000 31,400 C.O.P (17°F) 2.0 2.2 2.4 2.3 2.2 2.2 HSPF 8.0 8.0 8.0 8.0 8.0 8.0 Evaporator Motor Type ECM ECM ECM ECM ECM ECM Wheel (D x W) 10 x 9 10 x 9 10 x 9 10 x 9 10 x 9 10 x 9 Nominal Cooling CFM 860 1,000 1,200 1,300 1,600 1,950 FLA 4.3 4.3 4.3 2.9 2.9 7 No. of Speeds 5 5 5 5 5 5 Horsepower - RPM ½ -1,050 ½ -1,050 ½ -1,050 ¾ - 1,050 ¾ - 1,050 1-1,050 Evaporator Coil Face Area (ft²) 4.5 4.5 4.5 6.2 6.2 6.2 Rows Deep/ Fin per Inch 4/ 14 4/ 14 4/ 14 4/ 14 4/ 14 4/ 14 Expansion Device TXV TXV TXV TXV TXV TXV Drain Size (NPT) ¾" ¾" ¾" ¾" ¾" ¾" R-410A Refrigerant Charge (oz.) 120 128 175 213 195 195 Condenser Fan / Coil Horsepower - RPM ¼ - 850 ¼ - 850 ¼ - 850 ¼ - 1,075 ¼ - 1,075 ⅓ - 1,075 FLA/LRA 1.5/ 3.0 1.5/ 3.0 1.5/ 3.0 1.4 / 2.9 1.4 / 2.9 2.4/ 5.2 Fan Diameter / # Fan Blades 22 / 3 22 / 3 22 / 3 22 / 3 22 / 3 22 / 3 Face Area (ft²) 17.2 17.2 17.2 15 15 15 Rows Deep/ Fin per Inch 1 / 22 1 / 22 2 / 16 2 / 16 2 / 16 2 / 18 Compressor Quantity 1 1 1 1 1 1 Type Scroll Scroll Scroll Scroll Scroll Scroll Stage Single Single Single Single Two Two Electrical Data Voltage/ Phase (60 Hz) 208-230/ 1 208-230/ 1 208-230/ 1 208-230/ 1 208-230/ 1 208-230/ 1 Compressor RLA/ LRA 12.8 / 58.3 14.1 / 73 16.7 / 79 17.9 / 112 21.2 / 104 27.1 / 152.9 Indoor Blower FLA 4.3 4.3 4.3 2.9 2.9 7 Total Unit Amps 18.6 19.9 22.5 22.2 25.5 36.6 Min. Circuit Ampacity¹ 21.8 23.4 26.6 26.7 30.8 43.4 Max. Overcurrent Protection² 30 35 40 40 50 70 Shipping Weight (lbs) 366 375 428 472 470 483 ¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ² May use fuses or HACR-type circuit breakers of the same size as noted. Note: Always check the S&R plate for electrical data on the unit being installed. SS-<strong>APH15M</strong> www.amana-hac.com 3