OUTD OOR<br />
CONDENSER HEAT PUMP<br />
24 V AC<br />
ON<br />
OF F<br />
4<br />
6<br />
THERMOST AT<br />
HEAT ER<br />
Product Specifications<br />
Wiring Diagram — APH1524-36/43**<br />
YL<br />
R<br />
L1<br />
BK<br />
RD<br />
VSM<br />
16 PIN<br />
PLUG<br />
L1<br />
BK<br />
RD<br />
16 PIN<br />
PLUG<br />
C<br />
C<br />
N<br />
4<br />
5<br />
6<br />
PLF<br />
YL/PK<br />
T1<br />
VSM<br />
G<br />
LPS<br />
YL/PK<br />
YL/PK<br />
RD<br />
BL<br />
RD<br />
YL<br />
YL<br />
DC<br />
2 POLE ONLY<br />
SEE NOTE 7<br />
SEE NOTE 3<br />
VSM<br />
RVC<br />
T1<br />
LPS<br />
R<br />
R<br />
C<br />
C<br />
C<br />
CCR<br />
CNT<br />
0<br />
0<br />
LVDR<br />
0-RV<br />
C-RV<br />
W<br />
Y<br />
HVDR<br />
Y<br />
PS2<br />
DF1<br />
DF2<br />
DFT<br />
R-DFT<br />
R-PS1<br />
RD RD<br />
DFT<br />
SUPPLY VOLTAGE<br />
208-240/1/60<br />
R<br />
C<br />
COMP<br />
RCCF<br />
S<br />
H<br />
S.A.<br />
CHS<br />
RD RD<br />
L<br />
RVC<br />
SUPPLY VOLTAGE<br />
208-240/1/60<br />
T2 C<br />
T2<br />
SEE NOTE 6<br />
208-240<br />
SEE NOTE 2<br />
BK BK<br />
C<br />
C<br />
DF1<br />
HVDR<br />
F<br />
CM<br />
208-240<br />
SEE NOTE 2<br />
2<br />
1 3<br />
TR<br />
TR<br />
HPS<br />
CM<br />
OR<br />
YL<br />
RD<br />
RD<br />
PU<br />
CHS<br />
DFT<br />
RVC<br />
SEE NOTE 6<br />
PU<br />
CH<br />
CONTROL<br />
BOX<br />
DF2<br />
BL<br />
RD<br />
YL BR<br />
C<br />
H<br />
1<br />
C<br />
C<br />
RD<br />
BK<br />
L2<br />
2<br />
208<br />
TR<br />
24V<br />
RD<br />
YL BR<br />
F<br />
RCCF<br />
YL RD<br />
RD<br />
CONTROL<br />
BOX<br />
RD<br />
BK<br />
24V<br />
DFT<br />
R<br />
O-RV C-RV<br />
R-DFT DFT<br />
DC<br />
C<br />
O<br />
W<br />
Y<br />
R-PS1 PS2<br />
CNT<br />
LPS<br />
HPS<br />
BL<br />
WH<br />
WH<br />
BK<br />
H C F<br />
BK<br />
RCCF<br />
PU YL RD<br />
RD<br />
BK BK<br />
OR<br />
CH<br />
C<br />
1<br />
L2<br />
2<br />
3<br />
3<br />
240<br />
BL<br />
BL<br />
3<br />
2<br />
BL<br />
RD<br />
3<br />
2<br />
1<br />
BL<br />
RD<br />
BL<br />
PLF<br />
SA<br />
SEE NOTE 3<br />
BL/PK<br />
HPS<br />
SEE NOTE 2<br />
BL<br />
PLF<br />
SA<br />
SEE NOTE 3<br />
6<br />
6<br />
5<br />
5<br />
4<br />
9<br />
8<br />
41<br />
7<br />
PU<br />
BR<br />
CM<br />
PU<br />
PU<br />
BR<br />
BL/PK<br />
PU BK<br />
BL/PK<br />
HPS<br />
9<br />
8<br />
7<br />
BK<br />
BK<br />
RD<br />
RD<br />
COMPONENT LEGEND<br />
C<br />
CCR<br />
CH<br />
CHS<br />
CM<br />
COMP<br />
DC<br />
DFT<br />
GND<br />
HPS<br />
HVDR<br />
LPS<br />
LVDR<br />
LVJB<br />
PLF<br />
RVC<br />
RCCF<br />
SA<br />
TR<br />
VSM<br />
VSTB<br />
NOTES:<br />
CM<br />
PU<br />
BK<br />
BL<br />
RD<br />
RD<br />
COMPONENT LEGEND<br />
C<br />
CCR<br />
CH<br />
CHS<br />
CM<br />
COMP<br />
DC<br />
DFT<br />
GND<br />
HPS<br />
HVDR<br />
LPS<br />
LVDR<br />
LVJB<br />
PLF<br />
RVC<br />
RCCF<br />
SA<br />
TR<br />
VSM<br />
VSTB<br />
NOTES:<br />
BL<br />
BK<br />
BK<br />
PU<br />
PU<br />
T2<br />
T1<br />
BL<br />
RD<br />
OR<br />
BL<br />
RD<br />
OR<br />
BR<br />
BR<br />
PU<br />
RD<br />
BK<br />
YL<br />
RD<br />
BK<br />
YL<br />
S C R<br />
S C R<br />
COMP<br />
COMP<br />
L2<br />
C<br />
L1<br />
PU<br />
CONTACTOR<br />
COMPRESSOR CONTACTOR RELAY<br />
CRANKCASE HEATER<br />
CRANKCASE HEATER SWITCH<br />
CONDENSER MOTOR<br />
COMPRESSOR<br />
DEFROST CONTROL<br />
DEFROST THERMOSTAT<br />
EQUIPMENT GROUND<br />
HIGH PRESSURE SWITCH<br />
HIGH VOLTAGE DEFROST RELAY<br />
LOW PRESSURE SWITCH<br />
LOW VOLTAGE DEFROST RELAY<br />
LOW VOLTAGE JUNCTION BOX<br />
FEMALE PLUG / CONNECTOR<br />
REVERSING VALVE COIL<br />
RUN CAPACITOR FOR<br />
COMPRESSOR AND FAN<br />
START ASSIST<br />
TRANSFORMER<br />
VARIABLE SPEED MOTOR<br />
VARIABLE SPEED TERM BLOCK<br />
C R Y1 G Y1/Y2<br />
BK<br />
GND<br />
SEE NOTE 4<br />
R YCON C OM O W2ED<br />
W1<br />
W2<br />
O<br />
C<br />
R<br />
G<br />
Y<br />
<br />
FACTORY WIRING<br />
LINE VOLTAGE<br />
LOW VOLTAGE<br />
OPTIONAL HIGH<br />
VOLTAGE<br />
FIELD WIRING<br />
HIGH VOLTAGE<br />
LOW VOLTAGE<br />
WIRE CODE<br />
BK BLACK<br />
BL BLUE<br />
BR BROWN<br />
GR GREEN<br />
OR ORANGE<br />
PU PURPLE<br />
RD RED<br />
WH WHITE<br />
YL YELLOW<br />
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS<br />
ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.<br />
2. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE AND RED WIRES<br />
FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.<br />
3. START ASSIST FACTORY EQUIPPED WHEN REQUIRED.<br />
4. USE COPPER CONDUCTORS ONLY.<br />
++ USE N.E.C. CLASS 2 WIRE.<br />
5. REFER TO IO INSTRUCTIONS FOR SPEED SETTING.<br />
6. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY<br />
EQUIPPED WHEN REQUIRED.<br />
7. DOUBLE POLE CONTACTOR SHOWN. SINGLE POLE CONTACTOR<br />
COULD BE FACTORY EQUIPPED AS AN ALTERNATE CONFIGURATION.<br />
8. COMMON SIDE OF CONTACTOR CAN NOT BE GROUNDED OR<br />
CONNECTED TO ANY OTHER COMMON (24V).<br />
C<br />
PU<br />
H UMI DIS TA T<br />
HUM<br />
PU<br />
BK<br />
PU<br />
C R Y1<br />
CONTACTOR<br />
COMPRESSOR CONTACTOR RELAY<br />
CRANKCASE HEATER<br />
CRANKCASE HEATER SWITCH<br />
CONDENSER MOTOR<br />
COMPRESSOR<br />
DEFROST CONTROL<br />
DEFROST THERMOSTAT<br />
EQUIPMENT GROUND<br />
HIGH PRESSURE SWITCH<br />
HIGH VOLTAGE DEFROST RELAY<br />
LOW PRESSURE SWITCH<br />
LOW VOLTAGE DEFROST RELAY<br />
LOW VOLTAGE JUNCTION BOX<br />
FEMALE PLUG / CONNECTOR<br />
REVERSING VALVE COIL<br />
RUN CAPACITOR FOR<br />
COMPRESSOR AND FAN<br />
START ASSIST<br />
TRANSFORMER<br />
VARIABLE SPEED MOTOR<br />
VARIABLE SPEED TERM BLOCK<br />
PU<br />
GND<br />
DIP SWIT CH<br />
21 3875<br />
W1<br />
W2<br />
RD<br />
BK<br />
VSTB<br />
OTCOT1OT2<br />
CHS<br />
RD<br />
RD<br />
SEE NOTE 8<br />
SEE NOTE 7<br />
SEE NOTE 4<br />
E/W1<br />
W/W2<br />
O<br />
SEE<br />
NOTE 5<br />
LVJB<br />
WH<br />
BR<br />
OR<br />
BL<br />
GR YL<br />
BK<br />
BK<br />
CH<br />
BK<br />
2<br />
0<br />
8<br />
-<br />
2<br />
4<br />
0<br />
/<br />
1<br />
/<br />
6<br />
0<br />
WH W1<br />
T<br />
BR W2 H<br />
OR O<br />
E<br />
BL C R<br />
R M<br />
O<br />
S<br />
G<br />
T<br />
Y<br />
A<br />
RD<br />
T<br />
GR YL<br />
PU<br />
SEE<br />
NOTE 6<br />
SEE<br />
NOTE 6<br />
WIRE CODE<br />
BK BLACK<br />
BL BLUE<br />
BR BROWN<br />
GR GREEN<br />
OR ORANGE<br />
PU PURPLE<br />
RD RED<br />
WH WHITE<br />
YL YELLOW<br />
T<br />
H<br />
E<br />
R<br />
M<br />
O<br />
S<br />
T<br />
A<br />
T<br />
GR<br />
FACTORY WIRING<br />
LINE VOLTAGE<br />
LOW VOLTAGE<br />
OPTIONAL HIGH<br />
VOLTAGE<br />
FIELD WIRING<br />
HIGH VOLTAGE<br />
LOW VOLTAGE<br />
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS<br />
ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.<br />
2. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE AND RED WIRES<br />
FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.<br />
3. START ASSIST FACTORY EQUIPPED WHEN REQUIRED.<br />
4. USE COPPER CONDUCTORS ONLY.<br />
++ USE N.E.C. CLASS 2 WIRE.<br />
5. REFER TO IO INSTRUCTIONS FOR SPEED SETTING.<br />
6. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY<br />
EQUIPPED WHEN REQUIRED.<br />
7. DOUBLE POLE CONTACTOR SHOWN. SINGLE POLE CONTACTOR<br />
COULD BE FACTORY EQUIPPED AS AN ALTERNATE CONFIGURATION.<br />
8. COMMON SIDE OF CONTACTOR CAN NOT BE GROUNDED OR<br />
CONNECTED TO ANY OTHER COMMON (24V).<br />
PU<br />
PU<br />
SEE NOTE 8<br />
SEE NOTE 7<br />
SEE<br />
NOTE 5<br />
LVJB<br />
BK<br />
BK<br />
CH<br />
BK<br />
GR<br />
2<br />
0<br />
8<br />
-<br />
2<br />
4<br />
0<br />
/<br />
1<br />
/<br />
6<br />
0<br />
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power<br />
sources may be present. Failure to do so may cause property damage, personal injury, or death. ⚡<br />
Wiring is subject to change. Always<br />
refer to the wiring diagram or the<br />
⚠ Warning<br />
unit for the most up-to-date wiring.<br />
VSTB<br />
VSTB<br />
R W2 O W1 Y1 G <br />
YCON<br />
Y/<br />
R W/<br />
O E/<br />
Y1 G C<br />
W2<br />
W1 Y2<br />
THERMOSTAT<br />
THERMOSTAT<br />
SEE UNIT RATING PLATE FOR TYPE AND SIZE<br />
OF OVER CURRENT PROTECTION<br />
SEE UNIT RATING PLATE FOR TYPE AND SIZE<br />
OF OVER CURRENT PROTECTION<br />
0140G01638-B<br />
SS-<strong>APH15M</strong> www.amana-hac.com 29