The 4-in-1 Viscometer<br />

When you buy a <strong>Lovis</strong> <strong>2000</strong> M/<strong>ME</strong> microviscometer,<br />

you actually get all of these:<br />

Easy-operation viscometer<br />

With <strong>Lovis</strong> <strong>2000</strong> M/<strong>ME</strong>, there are 4 steps to a successful viscosity<br />

result, even less if you use an automatic sample changer. The<br />

easy-to-use features help you find settings automatically.<br />

1. Select the measuring method.<br />

The most important methods are predefined, e.g. viscosity and<br />

density, temperature scan from 5 °C to 100 °C, shear rate scan,<br />

intrinsic viscosity.<br />

2. Select the filling method.<br />

Fill small sample amounts by syringe (2a).<br />

For higher sample throughput, add a sample changer (2b).<br />

3. Press 'Start'.<br />

Measuring principle: <strong>Lovis</strong> <strong>2000</strong> M/<strong>ME</strong> is a rolling-ball<br />

viscometer which measures the rolling time of a ball through<br />

transparent and opaque liquids according to Höppler's principle.<br />

Results are given as relative, kinematic or dynamic viscosity. <strong>Lovis</strong><br />

<strong>2000</strong> M/<strong>ME</strong> also automatically calculates the relative viscosity,<br />

intrinsic viscosity, and other properties of polymer solutions.<br />

4. Read the results.<br />

Read results from the display, printout or connected PC monitor.<br />

Results can be transferred to a PC, LIMS or data storage device.<br />

Low-viscosity rolling-ball rheometer<br />

<strong>Lovis</strong> <strong>2000</strong> M/<strong>ME</strong> gives you the option of varying the inclination,<br />

which corresponds to the shear rate. Since the shear rates are<br />

variable and typically low, the instrument is perfectly suited for<br />

automated zero-shear viscosity extrapolation. Therefore, your<br />

<strong>Lovis</strong> <strong>2000</strong> M/<strong>ME</strong> doubles as a ‘lo vis’ rolling-ball rheometer.<br />

Time-saving viscometer<br />

The small size of <strong>Lovis</strong> <strong>2000</strong> M/<strong>ME</strong> allows quick and precise<br />

temperature control and measurement. Under optimal conditions,<br />

results are ready after 30 seconds.<br />

All-round viscometer<br />

As the name reveals, <strong>Lovis</strong> <strong>2000</strong> M/<strong>ME</strong> is particularly suited for<br />

low-viscosity liquids. Do you have other samples to measure<br />

Use <strong>Lovis</strong> <strong>2000</strong> M/<strong>ME</strong> as your all-round measuring station for<br />

samples with a wide range of viscosity at any temperature from<br />

5 °C to 100 °C. <strong>Lovis</strong> <strong>2000</strong> M/<strong>ME</strong> is even suitable for measuring<br />

highly corrosive or aggressive samples.