<strong>Halaco</strong> <strong>Engineering</strong> Co. IA Section 3<br />
CAD009688052<br />
(MTBE). The six downgradient samples exhibited concentrations of all VOC analytes that were<br />
at or below laboratory detection limits.<br />
3.2.3 Air Matrix Samples<br />
Thirty-five air samples were collected from six stations across the Site. The filters were screened<br />
for alpha radiation by EPA On-Scene Coordinator (OSC). There were no detections for alpha<br />
radiation above background concentrations, therefore none of these samples was submitted for<br />
laboratory analysis for radionuclides. The samples were submitted to a laboratory for metals<br />
analyses by EPA Method 6010B. The results for the air filter samples are presented in Table 3-8.<br />
Wind directions during the day were generally out of the west, southwest and northwest. As a<br />
result, the southwest sampling station, AIR1, may be considered the background location for the<br />
duration of the sampling program. Hourly meteorological data from the Oxnard Airport<br />
(distance approximately 2 miles) are presented in Appendix E (25).<br />
Metals results in downwind samples are compared to the background values from AIR1. Under<br />
the HRS, metals concentrations are considered significantly above background if results are<br />
either 1) three-times greater than the concentration detected in the background sample, or 2)<br />
detected in the downwind sample when the analyte has not been detected in the background<br />
sample at a lower detection limit.<br />
Metals were detected in downwind samples on every day that samples were collected. At least<br />
one of the following analytes: Sb, As, Be, Cd, Cu, Pb, Mg, Mn, Ni, Se, and Ag, are significantly<br />
elevated with respect to background in samples collected at air sampling stations 2, 3, 4, and 6<br />
during the sampling period. All of these stations are within one quarter mile of the WMU.<br />
3.2.4 Fish Tissue Samples<br />
Nine fish samples were submitted for whole fish analysis for metals and radionuclide analysis.<br />
The results indicate that radionuclides were not detected in any of the fish samples. The metals<br />
results are presented in Appendix H, and arsenic data are presented in Table 3-9.<br />
20