MDTFSL3X001_D_Dialight Street Light - Lincis
MDTFSL3X001_D_Dialight Street Light - Lincis
MDTFSL3X001_D_Dialight Street Light - Lincis
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
IES Type V - Measurement Data 1<br />
Iso-Illuminance Chart (fc)<br />
Example shown: 25 ft Mounting Height<br />
60 Watt<br />
Mounting<br />
Height<br />
Multiplier<br />
Intensity Distribution Curve (cd)<br />
0.1<br />
2.<br />
0.4<br />
0.2<br />
10 6.250<br />
15 2.228<br />
20 1.563<br />
25 1.000<br />
30 0.694<br />
35 0.510<br />
40 0.391<br />
45 0.309<br />
50 0.250<br />
Spacing of each box is equal to mounting height in feet.<br />
Ex: 40ft mounting height = each box is 40ft, 30ft mounting height = each box is 30ft<br />
- Location of streetlight<br />
120 Watt<br />
Iso-Illuminance Chart (fc)<br />
Example shown: 30 ft Mounting Height<br />
Intensity Distribution Curve (cd)<br />
0.1<br />
2. 0.27<br />
0.7<br />
Spacing of each box is equal to mounting height in feet.<br />
Ex: 40ft mounting height = each box is 40ft, 30ft mounting height = each box is 30ft<br />
- Location of streetlight<br />
Iso-Illuminance Chart (fc)<br />
Example shown: 40 ft Mounting Height<br />
3.<br />
Mounting<br />
Height<br />
Multiplier<br />
10 9.000<br />
15 4.000<br />
20 2.250<br />
25 1.440<br />
30 1.000<br />
35 0.735<br />
40 0.503<br />
45 0.444<br />
50 0.360<br />
180 Watt<br />
Intensity Distribution Curve (cd)<br />
Mounting<br />
Height<br />
Multiplier<br />
1.5<br />
.8<br />
0.4<br />
0.15<br />
Spacing of each box is equal to mounting height in feet.<br />
Ex: 40ft mounting height = each box is 40ft, 30ft mounting height = each box is 30ft<br />
- Location of streetlight<br />
1<br />
Cool white values shown – neutral white versions ≈ 6% lower<br />
10 16.000<br />
15 7.111<br />
20 4.000<br />
25 2.560<br />
30 1.778<br />
35 1.306<br />
40 1.000<br />
45 0.790<br />
50 0.640<br />
<strong>Dialight</strong> reserves the right to make changes at any time in order to supply the best product possible.<br />
The most current version of this document will always be available at:<br />
www.dialight.com/Assets/Brochures_And_Catalogs/Illumination/<strong>MDTFSL3X001</strong>.pdf<br />
www.dialight.com<br />
<strong>MDTFSL3X001</strong>_D