Leakage radiation<br />

• <strong>NCRP</strong>-<strong>147</strong> calculations (and shielding methods<br />

2 and 3) use<br />

– 3.33 mA at 150 kVp<br />

– worst case leakage rates<br />

– (Subsequently, we’ve found that assuming 4 mA at<br />

125 kVp leakage technique factors specifies<br />

barriers that are 10-20% thicker than in the report)<br />

– However, actual leakage rates are 0-30% of the<br />

maximum leakage so we don’t see a problem<br />