“Representative R&F Room”<br />
• Also assume a “Representative R&F room”<br />
– Has same layout as “Standard Radiographic Room<br />
except an undertable fluoro x-ray tube and image<br />
intensifier are added, centered over table<br />
– Does fluoro as well as standard radiographic work,<br />
with table and chest buckies and crosstable work<br />
• Assume<br />
– 75% of patients imaged as if in radiographic room<br />
– 25% of patients imaged by fluoroscopy tube<br />