Series description: <strong>Wilo</strong>-<strong>TOP</strong>-D<br />

Design<br />

Glandless circulation pump with screwed connection or flange<br />

connection.<br />

Application<br />

Hot-water heating systems of all kinds, air-conditioning systems,<br />

closed cooling circuits, industrial circulation systems<br />

Type key<br />

Example: <strong>Wilo</strong>-<strong>TOP</strong>-D 40<br />

<strong>TOP</strong>-D<br />

Standard pump (screw-end pump or flange-end<br />

pump)<br />

40 Nominal connection diameter<br />

Special features/product benefits<br />

• For installations with low pipework resistances, can be used in<br />

heating systems and in cooling/air-conditioning systems from<br />

-20 °C to +130 °C<br />

• Universal application for various mains operations:<br />

• 3~400/230 V, 1~230 V with use of a capacitor (accessory)<br />

• Pump housing with cataphoretic coating for the prevention of<br />

corrosion by condensation formation<br />

• Simple installation due to combination flange PN 6/PN 10 (for<br />

DN 40 to DN 65)<br />

Technical data<br />

• Permitted temperature range -20 °C to +130 °C, for short<br />

periods (2 h) to +140 °C<br />

• Mains connection:<br />

• 1~230 V, 50 Hz (with capacitor)<br />

• 3~230 V, 50 Hz<br />

• 3~400 V, 50 Hz<br />

• Protection class IP X4D<br />

• Screwed connection or flange connection (depending on type)<br />

Rp 1¼ to DN 125<br />

• Max. operating pressure, standard version: 6/10 bar or 6 bar<br />

(special version: 10 bar or 16 bar)


Equipment/function<br />

Manual functions<br />

• Setting of the speed stages: 1 speed stage<br />

Signal and display functions<br />

• Thermal winding contact (WSK, potential-free NC contact) for<br />

<strong>TOP</strong>-D 65 to <strong>TOP</strong>-D 125<br />

• Direction-of-rotation control light<br />

Equipment<br />

• In flange pumps: Flange versions<br />

• Standard version for pumps DN 40 to DN 65: Combination<br />

flange PN 6/10 (flange PN 16 acc. to EN 1092-2) for<br />

counter flanges PN 6 and PN 16,<br />

• Standard version for pumps DN 80 to DN 125: Flange PN 6<br />

(configured for PN 16 acc. to EN 1092-2) for counter flange<br />

PN 6,<br />

• Special version for pumps DN 65 to DN 125: Flange PN 16<br />

(acc. to EN 1092-2) for counter flange PN 16,<br />

• Cable inlet possible on both sides with <strong>TOP</strong>-D 65 to <strong>TOP</strong>-D 125<br />

• Blocking current-proof motor (only for <strong>TOP</strong>-D 30, 40, 50)<br />

• Standard thermal insulation for heating applications<br />

Materials<br />

• Pump housing: Grey cast iron<br />

• Impeller: Plastic<br />

• Shaft: stainless steel<br />

• Bearing: Carbon, metal impregnated<br />

Scope of delivery<br />

• Pump<br />

• Thermal insulation<br />

• Including seals for threaded connection<br />

• Washers for flange screws (for nominal connection diameters<br />

DN 40 - DN 65)<br />

• Installation and operating instructions<br />

Options<br />

• Versions for special voltages on request<br />

• Special version for operating pressure PN 16 (at additional<br />

charge)


Accessories<br />

• Screwed connection for threaded connection<br />

• Adapter fittings<br />

• Condenser for AC current operation 1~230 V<br />

• <strong>Wilo</strong>-SK-C2 condenser switchbox<br />

• <strong>Wilo</strong>-SK 602 tripping unit