8 Ordering code<br />

S R 3 C V M2 - 2 * * 2 - M 2 2 * * * /<br />

Type Separate unit single = M1, double = M2<br />

Motor mtg. (RS29) single = R1, double = R2<br />

Inlet section = E*<br />

Intermediate section = Z*<br />

End section = A*<br />

Bolt -on section = AP<br />

Service line relief for 1st controller in P in A<br />

None =* =*<br />

Pressure range 3 - 30 bar 9) Pressure range 30 - 70 bar<br />

=0 =4<br />

10) =1 =5<br />

Pressure range 70 - 200 bar = 2 = 6<br />

Pressure range 200 - 300 bar = 3 = 7<br />

Service line relief for 2nd controller in P in A<br />

None =* =*<br />

Pressure range 3 - 30 bar 9) Pressure range 30 - 70 bar<br />

=0 =4<br />

10) =1 =5<br />

Pressure range 70 - 200 bar = 2 = 6<br />

Pressure range 200 - 300 bar = 3 = 7<br />

Service line relief for 3rd controller in P in A<br />

None =* =*<br />

Pressure range 3 - 30 bar 9) =0 =4<br />

Pressure range 30 - 70 bar 10) Mounting body for SR3C cartridge valve<br />

0<br />

=1 =5<br />

Pressure range 70 - 200 bar = 2 = 6<br />

Pressure range 200 - 300 bar = 3 = 7<br />

Additional functions<br />

None = *<br />

For use with LS pump = L<br />

With bypass check valve = R<br />

With anti -cavitation for 1st controller = 1<br />

2nd controller = 2<br />

3rd controller = 3<br />

1st <strong>and</strong> 2nd controller = 4<br />

1st <strong>and</strong> 3rd controller = 5<br />

2nd <strong>and</strong> 3rd controller = 6<br />

1st, 2nd <strong>and</strong> 3rd controller = 7<br />

Design no. (to be inserted by the factory)<br />

Port threads DIN 3852 - M22 x 1,5 = M22<br />

(other threads - contact <strong>Bucher</strong> <strong>Hydraulics</strong>)<br />

Nominal voltage of proportional solenoid (for bodies with solenoid operated valves)<br />

12 V DC = G12<br />

24 V DC = G24<br />

none = ***<br />

Variants / special features (to be inserted by the factory)<br />

9) only to Qmax = 25 l/min 10) only to Qmax =40l/min<br />

The flow control valves must be ordered separately as detailed in section 6<br />

BUCHER HYDRAULICS www.bucherhydraulics.com<br />

Germany<br />

Phone +49 7742 85 20<br />

Fax +49 7742 71 16<br />

info.de@bucherhydraulics.com<br />

Switzerl<strong>and</strong><br />

Phone +41 33 67 26 11 1<br />

Fax+41336726103<br />

info.ch@bucherhydraulics.com<br />

France<br />

Phone +33 389 64 22 44<br />

Fax +33 389 65 28 78<br />

info.fr@bucherhydraulics.com<br />

Italy<br />

Phone +39 0522 92 84 11<br />

Fax +39 0522 51 32 11<br />

info.it@bucherhydraulics.com<br />

We reserve the right of modification without prior notice.<br />

Netherl<strong>and</strong>s<br />

UK<br />

Phone +31 79 34 26 24 4 Phone +44 24 76 35 35 61<br />

Fax+31793426288 Fax +44 24 76 35 35 72<br />

info.nl@bucherhydraulics.com info.uk@bucherhydraulics.com<br />

Austria<br />

China<br />

Phone +43 6216 44 97 Phone +86 512 6 322 12 99<br />

Fax+43621644974 Fax +86 512 6 322 10 33<br />

info.at@bucherhydraulics.com info.sh@bucherhydraulics.com<br />

USA<br />

Phone +1 262 605 82 80<br />

Fax +1 262 605 82 78<br />

info.wi@bucherhydraulics.com<br />

Product Center (Elevator)<br />

Phone +41 41 757 03 33<br />

Fax +41 41 755 16 49<br />

info.nh@bucherhydraulics.com<br />

100 -P -000044 -E -05 / 12.04 8/8