Circuit-breakers, switch-disconnectors<br />

up to 1600 A<br />

160 Technical data<br />

Fieldbus connection<br />

Dielectric strength<br />

Rating of the air and<br />

EN 50178, UL 508, CSA C22.2, No. 142<br />

creepage distance<br />

Dielectric strength EN 50178<br />

<strong>Moeller</strong> SK1230-1157GB-INT<br />

EASY221-CO EASY222-DN NZM-XDMI-DPV1<br />

Power supply<br />

Rated operational voltage Ue V 24 (-15/+20 %) 24 (-15/+20 %) 24 (-15/+20 %)<br />

Admissible range V DC 20.4 – 28.8 20.4 – 28.8 20.4 – 28.8<br />

Residual ripple % < 5 < 5 < 5<br />

At 24 V DC mA Averaged 200 Averaged 200 Averaged 200<br />

Voltage dips (IEC/EN 61131-2) ms 10 10 10<br />

Heat dissipation at 24 V DC W 4.8 4.8 4.8<br />

Protection against polarity reversal<br />

Power supply Yes Yes Yes<br />

LED displays<br />

Power supply LED RUN (RUN): green LED module status (MS): green LED power (POW): green<br />

LED display LED ERROR (ERR): red LED network status (NS):<br />

red/green<br />

LED-PROFIBUS-DP (BUS): red<br />

Network<br />

Connection types RJ45 5-pole, twin-level terminal block –<br />

Potential isolation Bus to power supply (simple,<br />

bus and power supply to EASY<br />

base unit (safe isolation)<br />

Bus to power supply (simple,<br />

bus and power supply to EASY<br />

base unit (safe isolation)<br />

Function CANopen slave DeviceNet slave –<br />

Interface CAN CAN –<br />

Bus protocol CANopen DeviceNet –<br />

Baud rates Automatic detection up to 1<br />

MBitxs<br />

Bus termination resistors Separate, external bus connection<br />

necessary (120 O)<br />

Bus addresses 1 – 127 via EASY base unit with<br />

display or EASY-SOFT addressable<br />

Automatic detection up to 500<br />

kBitxs<br />

Separate, external bus connection<br />

necessary (120 O)<br />

0 – 63 via EASY base unit with<br />

display or EASY-SOFT addressable<br />

Services –<br />

Cyclic All data R1 – R16, S1 – S8 All data R1 – R16, S1 – S8 –<br />

Acyclic Readxwrite, time, day,<br />

summer-xwinter time, all<br />

parameters of the EASY function<br />

Readxwrite, time, day,<br />

summer-xwinter time, all<br />

parameters of the EASY function<br />

PROFIBUS-DP<br />

Connection types – – Sub-D 9 pole, socket<br />

Potential isolation – – Bus to power supply (simple),<br />

bus and power supply to DMI base<br />

unit (safe isolation)<br />

Function – – PROFIBUS-DP slave<br />

Interface – – RS 485<br />

Bus protocol – – PROFIBUS-DP<br />

Baud rates – – Automatic detection up to<br />

12 MBitxs<br />

Bus termination resistors – – Switch-in via connector<br />

Bus addresses – – 1 – 126 via DMI<br />