Circuit Breakers,<br />

Disconnect Switches, Molded Case Switches<br />

09/018<br />

Molded Case Circuit Breakers and Switches<br />

Undervoltage Trips for Type NZM7...-NA<br />

Contact<br />

Diagram<br />

Undervoltage trip, undelayed<br />

Rated<br />

Actuating Voltage<br />

Us<br />

Undervoltage trips will electrically trip the device open under power<br />

loss (when supply voltage drops below 35% - 70% of rated trip coil<br />

value) and can be used for control interlocking purposes, e.g. to<br />

disconnect the main switch in Emergency-stop circuits. They are<br />

rated for continuous duty.<br />

Undervoltage trips cannot be mounted together with shunt trips.<br />

Notes<br />

D1<br />

D2<br />

V<br />

Moeller Electric Corporation<br />

AC 24 +U-NZM7(24VAC)<br />

027309<br />

48 +U-NZM7(48VAC)<br />

027310<br />

60 +U-NZM7(60VAC)<br />

027311<br />

110 – 120 +U-NZM7(110-120VAC)<br />

027312<br />

125 – 130 +U-NZM7(125-130VAC)<br />

027313<br />

208 – 215 +U-NZM7(208-215VAC)<br />

027314<br />

220 – 240 +U-NZM7(220-240VAC)<br />

027315<br />

380 – 415 +U-NZM7(380-415VAC)<br />

027316<br />

440 – 480 +U-NZM7(440-480VAC)<br />

027317<br />

DC 24 +U-NZM7(24VDC)<br />

027599<br />

48 +U-NZM7(48VDC)<br />

027342<br />

60 +U-NZM7(60VDC)<br />

027343<br />

110 – 120 +U-NZM7(110-120VDC)<br />

027344<br />

125 +U-NZM7(125-130VDC)<br />

027345<br />

1) Undervoltage trips are field-installable<br />

Type Suffix Price Type Price<br />

Article No.<br />

see price list Article No.<br />

when ordered with basic device<br />

when ordered separately 1)<br />

see price list<br />

Auxiliary contacts and voltage trips can be installed as follows:<br />

NHI RHI VHI A AVHI U U(V)HI<br />

2 x EK... 1 x EK...<br />

● ● ● – – – –<br />

● ● – ● – – –<br />

● ● – – ● – –<br />

● ● – – – ● –<br />

● ● – – – – ●<br />

Dots in each row represent the types which can be combined together:<br />

● allowed combination<br />

– combination not allowed<br />

U-NZM7(24VAC)<br />

028847<br />

U-NZM7(48VAC)<br />

028848<br />

U-NZM7(60VAC)<br />

028849<br />

U-NZM7(110-120VAC)<br />

028850<br />

U-NZM7(125-130VAC)<br />

028851<br />

U-NZM7(208-215VAC)<br />

028852<br />

U-NZM7(220-240VAC)<br />

027608<br />

U-NZM7(380-415VAC)<br />

065565<br />

U-NZM7(440-480VAC)<br />

028854<br />

U-NZM7(24VDC)<br />

027607<br />

U-NZM7(48VDC)<br />

028879<br />

U-NZM7(60VDC)<br />

028880<br />

U-NZM7(110-120VDC)<br />

028881<br />

U-NZM7(125-130VDC)<br />

028882<br />

1-866-595-9616<br />

1-630-595-9515 Go to: http://www.klocknermoeller.com