Circuit Breakers,<br />
Disconnect Switches, Molded Case Switches<br />
09/042<br />
Moeller Electric Corporation<br />
Molded Case Circuit Breakers and Switches<br />
Auxiliary Contacts, Signalling Unit for Type NZM10-...-NA<br />
NHI standard auxiliary contact<br />
Switching simultaneously with the main contacts. They can be typically used for<br />
signalling, interlocking or switching auxiliary circuits such as a control circuit.<br />
VHI early-make auxiliary contact<br />
Typically used for powering up the undervoltage trip prior to closing of main contacts<br />
and for control circuit interlocking tasks.<br />
Cannot be used in conjunction with R-NZM10 remote control drive.<br />
RHI trip-indicating auxiliary contact<br />
Actuating independently of the normal ON and OFF operations of the device,<br />
sswitching only when the device has tripped due to overcurrents or other tripping<br />
causes such as those initiated by voltage trips.<br />
Signalling block<br />
Differential fault indication and visual display of breaker operating states:<br />
(1)+(2)tripping due to short circuit<br />
(2)tripping due to overload and general trip condition<br />
(3)overload early warning signal in the event that the long time response<br />
setting is about to be exceeded (i.e. useful for load shedding purposes)<br />
Each function signals via a pair of contacts (1 N.O. and 1 N.C.)<br />
Mounts directly onto lower portion of circuit breaker<br />
Required supply voltage: 24 - 230V, AC or DC<br />
Contact diagram Type suffix Price Type Price<br />
Article No.<br />
when ordered with<br />
basic device<br />
+NHI-NZM10<br />
034798<br />
+VHI-NZM10<br />
034800<br />
+RHI-NZM10<br />
034797<br />
3 poles +M-NZM10<br />
034801<br />
Notes:<br />
1.13 1.21 1.43 1.31<br />
1.14 1.22 1.44 1.32<br />
3.13 3.33 3.21<br />
3.14 3.34 3.22<br />
4.13 4.21 4.43 4.31<br />
4.14 4.22 4.44 4.32<br />
(1) (2) (3)<br />
5.53 5.61 5.33 5.41 5.13 5.21<br />
5.54 5.62 5.34 5.42 5.14 5.22<br />
I �<br />
� 100% Ir<br />
1) Auxiliary contacts and signalling blocks are field installable.<br />
see price list Article No.<br />
when ordered<br />
separately 1)<br />
NHI-NZM10<br />
034943<br />
VHI-NZM10<br />
034944<br />
RHI-NZM10<br />
034945<br />
M-NZM10<br />
034946<br />
see price list<br />