Zinc Oxide Varistors<br />

Reliability<br />

Test Description Test Condition Test Requirement<br />

SURGE CURRENT DERATING CECC 42000, Test C 2.1 • I Delta V/V (1 mA) I max 10%<br />

8/20 MICRO SECONDS 100 surge currents (8/20 µs), unipolar, Measured in the direction of the<br />

interval 30 s, amplitude corresponding<br />

surge current<br />

to derating curve for 20 µs.<br />

• No visible damage<br />

SURGE CURRENT DERATING CECC 42000, Test C 2.1 • I Delta V/V (1 mA) I max 10%<br />

10/1000 MICRO SECONDS 100 surge currents (10/1000 µs), unipolar, Measured in the direction of the<br />

interval 120 s, amplitude corresponding<br />

surge current<br />

to derating curve for 1000 µs.<br />

• No visible damage<br />

RESISTANCE TO SOLDERING IEC 68-2-20, Test Tb Method 1A • I Delta V/V (1 mA) I max 5%<br />

HEAT<br />

260°C, 5 s<br />

RAPID CHANGE IN IEC 68-2-14, Test Na • I Delta V/V (1 mA) I max 5%<br />

TEMPERATURE<br />

Ta = -40°C; Tb = +85°C<br />

Duration: 1 Hr/cycle<br />

• No visible damage<br />

Total: 5 cycles<br />

SHOCK IEC 68-2-27, Test Ea • I Delta V/V (1 mA) I max 5%<br />

Pulse shape: half sine<br />

Acceleration: 490 m/s/s<br />

• No visible damage<br />

Pulse duration: 11 ms<br />

3 x 6 shocks<br />

VIBRATION IEC 68-2-6, Test Fc Method B4 • I Delta V/V (1 mA) I max 5%<br />

Freq. range: 10 Hz ... 55 Hz<br />

Amplitude: 0.75 mm or 98 m/s/s<br />

• No visible damage<br />

Duration: 6 h (3 x 2 h)<br />

CLIMATIC SEQUENCE CECC 42000, Test 4.16 • I Delta V/V (1 mA) I max 10%<br />

a) Dry heat - Test Ba<br />

Temperature / Duration: 125°C / 2 h • Insulation Resistance min 1 Mohm<br />

b) Damp heat cyclic 1st cycle - Test Db<br />

Temperature / Duration: 55°C / 24 h<br />

Humidity: 95-100% RH<br />

c) Cold - Test Aa<br />

Temperature / Duration: -40°C / 2 h<br />

d) Damp heat cyclic test remaining<br />

5 humidity cycles - Test Db<br />

Duration: 24 h/cycle<br />

LIFE TEST CECC 42000, Test 4.20 • I Delta V/V (1 mA) I max 10%<br />

Applied voltage: max continuous a.c.<br />

Voltage, continuous application<br />

• Insulation Resistance min 10 Mohm<br />

Temperature / Duration: 85°C / 1000 h<br />

DAMP HEAT, STEADY STATE IEC 68-2-3 • I Delta V/V (1 mA) I max 10%<br />

Temperature / Duration: 40°C / 56 days<br />

Humidity: 93%<br />

• Insulation Resistance min 1 Mohm<br />

FLAMMABILITY - IEC 695-2-2 • Burning max 10 s<br />

NEEDLE FLAME TEST<br />

Vertical application: 10 s<br />

TEMPERATURE COEFFICIENT Current: 1 mA • - (0.09%/K) max<br />

OF VOLTAGE<br />

Temperature: -40°C / +25°C / +85°C<br />