22.02.2015 Views

APPENDIX I: Noise Monitoring Data - Xstrata Coal Mangoola

APPENDIX I: Noise Monitoring Data - Xstrata Coal Mangoola

APPENDIX I: Noise Monitoring Data - Xstrata Coal Mangoola

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Environmental <strong>Noise</strong> Levels<br />

20 March 2004, 0306 hours<br />

TotL1 TotL10 TotLeq TotL90 L1 L10 Leq L90<br />

70<br />

65<br />

60<br />

55<br />

50<br />

Measured <strong>Noise</strong> Levels<br />

LA1 39 dB<br />

LA10 37 dB<br />

LAeq 35 dB<br />

LA90 32 dB<br />

dB(A)<br />

45<br />

40<br />

35<br />

30<br />

Mine dragline fans, bucket noise, rear<br />

dump truck engine and transmission noise<br />

Insects<br />

Site Only <strong>Noise</strong> Levels<br />

LA10 34 dB<br />

LAeq 32 dB<br />

All statistics are 15min<br />

unless noted otherwise<br />

25<br />

Frogs<br />

20<br />

50<br />

63<br />

80<br />

100<br />

125<br />

160<br />

200<br />

250<br />

315<br />

400<br />

500<br />

630<br />

800<br />

1000<br />

1250<br />

1600<br />

2000<br />

2500<br />

3150<br />

4000<br />

5000<br />

6300<br />

8000<br />

10000<br />

Total<br />

Frequency (Hz)<br />

Figure 2<br />

Sample Graph<br />

19<br />

12509_R02.doc<br />

Page 19