DENTSPLY ORAQIX<br />

<strong>Chemwatch</strong> Independent Material Safety Data Sheet<br />

Issue Date: 25-Nov-2009 CHEMWATCH <strong>22</strong>-<strong>5369</strong><br />

C9317TC<br />

Version No:2.0<br />

CD 2010/2 Page 2 of 6<br />

Section 4 - FIRST AID MEASURES<br />

SKIN<br />

■ If skin contact occurs:<br />

• Immediately remove all contaminated clothing, including footwear.<br />

• Flush skin and hair with running water (and soap if available).<br />

• Seek medical attention in event of irritation.<br />

INHALED<br />

• If fumes or combustion products are inhaled remove from contaminated area.<br />

• Lay patient down. Keep warm and rested.<br />

• Prostheses such as false teeth, which may block airway, should be removed, where possible, prior to initiating first aid procedures.<br />

• Apply artificial respiration if not breathing, preferably with a demand valve resuscitator, bag-valve mask device, or pocket mask as trained.<br />

Perform CPR if necessary.<br />

NOTES TO PHYSICIAN<br />

■ When systemic reaction to local anaesthetic occurs, steps should be taken to maintain circulation and respiration and control convulsions. A clear<br />

airway should be established and oxygen given together with assisted ventilation if necessary.<br />

Metabolism of amide-type anaesthetics occurs in the liver and in some cases in the kidney. Because these undergo extensive and rapid hepatic<br />

metabolism, only about 1/3 of an oral dose reaches the systemic circulation.<br />

Section 5 - FIRE FIGHTING MEASURES<br />

EXTINGUISHING MEDIA<br />

• There is no restriction on the type of extinguisher which may be used.<br />

• Use extinguishing media suitable for surrounding area.<br />

FIRE FIGHTING<br />

• Alert Fire Brigade and tell them location and nature of hazard.<br />

• Wear full body protective clothing with breathing apparatus.<br />

• Prevent, by any means available, spillage from entering drains or water course.<br />

• Use water delivered as a fine spray to control fire and cool adjacent area.<br />

FIRE/EXPLOSION HAZARD<br />

• The material is not readily combustible under normal conditions.<br />

• However, it will break down under fire conditions and the organic component may burn.<br />

• Not considered to be a significant fire risk.<br />

• Heat may cause expansion or decomposition with violent rupture of containers.<br />

Combustion products include: carbon dioxide (CO2), carbon monoxide (CO), hydrogen chloride, phosgene, nitrogen oxides (NOx), other pyrolysis products<br />

typical of burning organic material.<br />

May emit poisonous fumes.<br />

May emit corrosive fumes.<br />

FIRE INCOMPATIBILITY<br />

• Avoid contamination with oxidising agents i.e. nitrates, oxidising acids, chlorine bleaches, pool chlorine etc. as ignition may result.<br />

HAZCHEM<br />

None<br />

PERSONAL PROTECTION<br />

Glasses:<br />

Chemical goggles.<br />

Respirator:<br />

Particulate<br />

Section 6 - ACCIDENTAL RELEASE MEASURES<br />

MINOR SPILLS<br />

• Remove all ignition sources.<br />

• Clean up all spills immediately.<br />

• Avoid breathing vapours and contact with skin and eyes.<br />

• Control personal contact by using protective equipment.<br />

MAJOR SPILLS<br />

■ Moderate hazard.<br />

• Clear area of personnel and move upwind.<br />

• Alert Fire Brigade and tell them location and nature of hazard.<br />

• Wear breathing apparatus plus protective gloves.<br />

• Prevent, by any means available, spillage from entering drains or water course.<br />

Personal Protective Equipment advice is contained in Section 8 of the <strong>MSDS</strong>.<br />

continued...

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!