<strong>FRESH</strong> <strong>REXUS</strong><br />
Supply Air Terminal Device<br />
<strong>FRESH</strong> AIR - HEALTHIER LIFE
<strong>FRESH</strong> Rexus<br />
Supply Air Terminal Device • 4:01<br />
• Telescopic radiator unit<br />
• Universal<br />
• Quick assembly<br />
• Easy filter replacement<br />
• Complete accessories<br />
The Fresh Rexus is an efficient supply<br />
air terminal device for use with conventional<br />
radiators. The unit functions with singlepanel,<br />
double-panel and triple-panel radiators<br />
mounted on standard suspension brackets<br />
(at least 25 mm from the wall). The unit<br />
offers flexibility regarding placement of the<br />
intake duct. Fresh Rexus meets stringent<br />
requirements for introducing filtered,<br />
preheated air into homes and residential<br />
spaces without creating annoying draughts. A<br />
removable cleaning hatch on the top of<br />
the device facilitates maintenance.<br />
Specification<br />
Designation Description Item no. RSK<br />
Rexus wall unit 300-550 Telescopic wall unit for radiators<br />
420035 6606600<br />
300, 400, 450 or 500 mm in height.<br />
Max. height: 550 mm<br />
Rexus wall unit 600-850 Telescopic wall unit for radiators<br />
420036 66066601<br />
600, 700 or 800 mm in height.<br />
Max. height: 850 mm<br />
Rexus filter cartridge 11, 21 Filter cartridge with damper<br />
413288 6606602<br />
for radiator type 11<br />
Rexus filter cartridge 22 Filter cartridge with damper<br />
413289 6606604<br />
for radiator type 22<br />
Rexus filter cartridge 33 Filter cartridge with damper<br />
for radiator type 33<br />
413290 6606605<br />
Fast Facts<br />
Product: Unit for radiator type 11/21/22/33<br />
Capacity at 10 Pa:<br />
10.8 l/s<br />
Material:<br />
Galvanised metal<br />
Colour:<br />
White NCS S0502-Y
<strong>FRESH</strong> Rexus<br />
Supply Air Terminal Device • 4:02<br />
Description<br />
Fresh Rexus is a telescopic supply air<br />
terminal device mounted behind the radiator<br />
between its suspension brackets. The<br />
unit fits most radiator brands. Two units<br />
can be mounted adjacently behind the<br />
same radiator. The unit’s depth is adapted<br />
to standard brackets (based on a min.<br />
recommended distance of 25 mm between<br />
wall and radiator). The unit is made of<br />
galvanised steel and powder coated white<br />
(NCS S0502-Y). All models are available for<br />
radiators of various heights.<br />
Function<br />
Outdoor air enters a vent on the exterior<br />
wall and flows through a duct or drum into<br />
the unit. The air is then forced down to<br />
the base of the radiator, where it passes<br />
through a damper and filter. The air is<br />
heated by the convector plates. The warm,<br />
filtered air then flows through the grille on<br />
the top of the radiator and blends with room<br />
air. A deflector is mounted between the<br />
panels to direct airflow through the radiator.<br />
Cleaning hatch<br />
Types 11, 21, 22 & 33<br />
The wall component for types 11,21,22<br />
and 33 (double panel) is fastened to the<br />
radiator by two forked edges. A rubber strip<br />
forms a tight seal against the wall. The wall<br />
component contains a cleaning hatch on<br />
top and a damper and filter cartridge in its<br />
base. The filter cartridge can easily be pulled<br />
out for cleaning and replacement.<br />
Cleaning<br />
The wall duct can be cleaned through the<br />
removable hatches in the unit’s top and<br />
base. A flexible hose attached to a vacuum<br />
cleaner can be used to clean the intake<br />
channel and vent when necessary.<br />
Removable Filter Cartridge<br />
• In types 11-33<br />
• Does not obstruct plumbing or mouldings<br />
• Utilises all panels<br />
• Adjustable damper<br />
• Easily-accessible filter<br />
(Standard G2 & Allergen F7)<br />
Deflector<br />
Damper<br />
Filter cartridge with<br />
standard/allergen filter<br />
Telescopic<br />
The supply air terminal device is telescopic,<br />
so the same wall component fits radiators<br />
within one of two height ranges: 300-500<br />
mm or 600-800 mm. The maximum height<br />
is 500 mm or 850 mm, which facilitates<br />
installation even when the intake channel is<br />
placed above the radiator.<br />
Easy Assembly<br />
Mount the radiator brackets in the proper<br />
positions. Extend the unit telescopically to<br />
match the height of the radiator and attach<br />
it to the radiator. Install the deflector.<br />
Mount the radiator on its brackets. The unit<br />
will follow and become fixed between the wall<br />
and radiator. Insert the filter cartridge when<br />
ready for use.<br />
• Easy to manage at building sites, few<br />
varieties<br />
• Filters and cartridges need not be<br />
inserted during construction.<br />
• Easy to centre the unit on the radiator<br />
and the vent on the exterior wall
<strong>FRESH</strong> Rexus<br />
Supply Air Terminal Device • 4:03<br />
Technical Data<br />
Capacity - Types 11, 21, 22 and 33<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Type: 11, 21, 22 and 33,<br />
Double/triple panel<br />
Dimensions: Length 370 mm,<br />
Depth 24 mm<br />
For radiator height 300, 400,<br />
450, 500, 600, 700 and 800<br />
Material:<br />
Colour:<br />
Dimensions<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
0.7 mm steel<br />
Visible surfaces lacquered<br />
white NCS S0502-Y<br />
Note: A free space of at least 10 mm<br />
above the unit is recommended to<br />
facilitate removal of the cleaning<br />
hatch.<br />
2 x forked holds<br />
(adjustable)<br />
Cleaning hatch<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Pressure Drop<br />
Pa<br />
20<br />
10<br />
8<br />
6<br />
4<br />
3<br />
2<br />
1<br />
1 2 3 4 5 6 7 8 910 15 l/s<br />
5 10 15 20 30 40 m 3 /h<br />
Airflow<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
24 w/o sealing<br />
<br />
strip<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Filter cartridge with<br />
<br />
damper <br />
and filter<br />
<br />
<br />
<br />
<br />
Wall unit<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Filter cartridge with<br />
<br />
<br />
damper and filter<br />
<br />
<br />
<br />
<br />
<br />
<br />
Cartridge holder<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Telescopic component<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
A measurement<br />
Radiator height 300=365 mm<br />
Radiator height 400=465 mm<br />
Radiator height 450=515 mm<br />
Radiator height 500=565 mm<br />
<br />
<br />
<br />
<br />
<br />
<br />
B measurement (nominal)<br />
<br />
Type <br />
11/ 21 = 86 mm<br />
Type <br />
22 = 117 mm<br />
Type 33 = 167 mm<br />
<br />
The filter cartridge for<br />
type 11/21 has a<br />
straight front edge<br />
<br />
<br />
<br />
<br />
The supply air terminal unit can be<br />
adjusted to fit radiator heights 300,<br />
400, 450 and 500. Height is fixed<br />
with plastic plugs
<strong>FRESH</strong> Rexus<br />
Supply Air Terminal Device • 4:04<br />
Inlet Hole Diagram<br />
Distance <br />
between top of<br />
radiator <br />
and top of unit<br />
<br />
<br />
<br />
Radiator bracket<br />
Radiator hight<br />
300-550 or 600-850<br />
The inlet <br />
hole can be<br />
bored <br />
in this area<br />
Supply air terminal device<br />
<br />
<br />
<br />
<br />
Distance between base of radiator<br />
<br />
and base of inlet hole bore area<br />
<br />
Floor <br />
<br />
<br />
<br />
<br />
<br />
The recommended min. radiator length is The unit is<br />
500 mm. <br />
adjustable to<br />
fit radiators<br />
If the radiator is manufactured with welded<br />
hangers, <br />
300-550 and<br />
there must be a least 375 mm<br />
<br />
600-850 in<br />
between them.<br />
height.<br />
The supply air terminal is mounted on the back<br />
of the radiator before the radiator is placed on<br />
its brackets.<br />
If two units are mounted behind the same<br />
radiator, there must be at least 100 mm<br />
between them.<br />
<br />
The distance <br />
between wall and radiator should<br />
be 25 mm.<br />
<br />
There should be at least 10 mm of free space<br />
above the cleaning <br />
<br />
hatch, which protrudes<br />
10 mm above the radiator. The distance <br />
between the <br />
window ledge and the top of<br />
the unit should be at least 20 mm.<br />
Radiators with supply air valves should always<br />
be equipped with regulating thermostat valves.<br />
310-560 or 610-860<br />
Cartridge with standard or<br />
allergen <br />
(F7) filter for type<br />
11, 21, <br />
22 or 33.
<strong>FRESH</strong> Rexus<br />
Supply Air Terminal Device • 4:05<br />
Installation Examples<br />
Standard & Wind<br />
Exposure<br />
Fresh Rexus with modular duct<br />
Ø98/102 mm plus one-way<br />
storm shield with backdraught<br />
damper. Exterior metal vent with<br />
sleeve, connection 100/130 mm<br />
Standard & Coastal<br />
Exposure<br />
Fresh Rexus with duct<br />
Ø98/102 mm. Exterior<br />
weather protection,<br />
storm hood.<br />
Concealed Intake<br />
TK-30x300<br />
Fresh Rexus with rectangular<br />
intake duct in galvanised steel<br />
with dimensions 300 x 30 mm.<br />
Telescopically adjustable length:<br />
160 - 280 or 260 - 480 mm.<br />
Noise Exposure<br />
& Concealed Intake<br />
Fresh Rexus with sound<br />
dampening. Intake duct<br />
ZK-dB R 300x30-130 with<br />
interior cleaning hatch.<br />
Noise Exposure<br />
Fresh Rexus with sound<br />
dampening dB duct<br />
Ø99/140 mm. Exterior metal<br />
vent with sleeve, connection<br />
100/130 mm or brick module<br />
with vent in copper or<br />
galvanised metal.<br />
Noise Exposure -<br />
Perforated dB Duct<br />
Fresh Rexus with sound damp.<br />
perf. dB duct with fibreglass and<br />
moisture barrier. Dim. Ø98/102<br />
mm. Length 200 or 300 mm<br />
(other lengths avail. upon<br />
request). Interior sleeve 10 and<br />
exterior metal vent with sleeve.
<strong>FRESH</strong> Rexus<br />
Supply Air Terminal Device • 4:06<br />
Make your calculations at<br />
www.fresh.se<br />
Using our calculation programme, you can<br />
quickly fill in operational parameters to<br />
calculate the height and type of radiator<br />
that best suits your needs. The table<br />
indicates insufficient radiator output and<br />
low treated air temperature in red. The<br />
programme also indicates the resulting<br />
pressure drop using different filter<br />
alternatives. You can easily fill out a form<br />
that will help you compose your order and<br />
follow up during installation. The complete<br />
programme can be found at www.fresh.se.<br />
55 o C<br />
45 o C<br />
Desired radiator output<br />
w/ ventilation 1000 W<br />
Desired room temp.<br />
Design outdoor temp.<br />
20 o C<br />
-20 o C<br />
* Estimated Radiator Output (W)<br />
Radiator Height<br />
Type 300 400 450 500 600<br />
21 581 856 918 1035 1175<br />
(526) (711) (730) (861) (1002)<br />
22 777 991 1046 1170 1321<br />
(720) (911) (930) (1092) (1265)<br />
Flow water temp.<br />
55 o C<br />
Return water temp. 45 o C<br />
Air volume/unit (4-12 l/s) 8 l/s<br />
Unit quantity/radiator 1<br />
Desired radiator length 1400 mm<br />
** Treated Air Temperature (ºC)<br />
Radiator Height<br />
Type 300 400 450 500 600<br />
21 12 19 22 24 28<br />
22 15 21 24 26 32<br />
* Estimated radiator output is calculated<br />
based on given operational parameters.<br />
The figure in parentheses indicates the<br />
radiator’s original output without the air<br />
terminal device. Cells marked in red<br />
indicate radiator sizes unable to achieve<br />
the desired output.<br />
Pressure Drop Across Unit with Filter<br />
and Grille (Pa)<br />
Type Standard Filter Allergen Filter<br />
21 9 21<br />
22 7 17<br />
** The temperature of the treated air diffused<br />
into to the room should be greater than<br />
+15 o C to maintain an acceptable indoor<br />
climate. Cells marked in red indicate radiator<br />
sizes unable to maintain an adequate<br />
temperature.
<strong>FRESH</strong> Rexus<br />
Supply Air Terminal Device • 4:07<br />
Radiator Output with Device<br />
Entered Data:<br />
Desired room temp.<br />
20 o C<br />
Design outdoor temp.<br />
-20 o C<br />
Flow water temp.<br />
55 o C<br />
Return water temp.<br />
45 o C<br />
Air volume<br />
8/10/12 l/s<br />
Desired radiator length 900 mm<br />
Air Distribution Diagram<br />
Boundaries for 0.15 m/s<br />
Airflow:<br />
10 l/s<br />
Outdoor temp: -15ºC<br />
Oper. Cond.: + 30 (55/45/20)<br />
Radiator Output with Rexus type 11<br />
800<br />
Radiator Output (W)<br />
750<br />
700<br />
650<br />
600<br />
550<br />
500<br />
450<br />
Radiator Height<br />
600 mm<br />
Radiator Height<br />
500 mm<br />
Radiator Height<br />
400 mm<br />
Radiator Height<br />
300 mm<br />
m<br />
2,2<br />
2,1<br />
2,0<br />
400<br />
350<br />
1,9<br />
300<br />
8<br />
10<br />
Airflow (l/s)<br />
12<br />
1,8<br />
1200<br />
Radiator Output with Rexus type 21<br />
1,7<br />
Radiator Output (W)<br />
1100<br />
1000<br />
900<br />
800<br />
Radiator Height<br />
600 mm<br />
Radiator Height<br />
500 mm<br />
Radiator Height<br />
400 mm<br />
1,6<br />
1,5<br />
700<br />
600<br />
Radiator Height<br />
300 mm<br />
1,4<br />
500<br />
1,3<br />
400<br />
300<br />
8<br />
10<br />
12<br />
1,2<br />
Airflow (l/s)<br />
Radiator Output with Rexus type 22<br />
1,1<br />
1300<br />
1200<br />
Radiator Height<br />
600 mm<br />
1,0<br />
Radiator Output (W)<br />
1100<br />
1000<br />
900<br />
800<br />
Radiator Height<br />
500 mm<br />
Radiator Height<br />
400 mm<br />
0,9<br />
0,8<br />
700<br />
600<br />
Radiator Height<br />
300 mm<br />
0,7<br />
500<br />
0,6<br />
400<br />
8<br />
10<br />
Airflow (l/s)<br />
12<br />
0,5<br />
Radiator Output with Rexus type 33<br />
1800<br />
0,4<br />
Radiator Output (W)<br />
1600<br />
1400<br />
1200<br />
Radiator Height<br />
600 mm<br />
Radiator Height<br />
500 mm<br />
Radiator Height<br />
400 mm<br />
0,3<br />
0,2<br />
1000<br />
Radiator Height<br />
300 mm<br />
0,1<br />
800<br />
600<br />
0<br />
0 0,1 0,2 0,3 0,4 0,5 m<br />
400<br />
8<br />
10<br />
12<br />
Airflow (l/s)
<strong>FRESH</strong> Rexus<br />
Supply Air Terminal Device • 4:08<br />
Fresh Intake Ducts<br />
for the Air Terminal Device<br />
Modular Duct (standard)<br />
Modular wall ducts that<br />
interconnect with press fit.<br />
Available in a variety of<br />
diameters and lengths.<br />
Modular Duct Dimensions (mm)<br />
Product D1 D2 L Item No.<br />
Ø81/85 x 75 81 85 75 660875<br />
Ø81/85 x 150 81 85 150 800150<br />
Ø98/102 x 50 98 102 50 661050<br />
Ø98/102 x 100 98 102 100 188009<br />
Sleeve Int RS<br />
Sleeves fit within modular wall<br />
ducts and dB ducts to serve<br />
as telescopic connectors from<br />
the exterior to the interior duct.<br />
A built-in rain shield prevents<br />
water that may enter the duct<br />
from progressing.<br />
Interior Sleeve Dimensions (mm)<br />
Product Int. Ø Ext. Ø L Item No.<br />
Sleeve 8int rs<br />
Ø81 x 30<br />
Sleeve 10int<br />
Ø98 x 60 rs<br />
77 81 30 660831<br />
94 98 60 661061<br />
dB Duct Ø98/140 mm<br />
(sound dampening)<br />
Delivered in standard<br />
lengths of 400 mm and easily<br />
cut to the desired length with,<br />
for example, an insulation knife.<br />
Additional lengths delivered upon request.<br />
Intake Duct Dimensions (mm)<br />
Product<br />
dB Duct<br />
98/140<br />
dB Duct<br />
98/140<br />
Int.<br />
Ø<br />
Ext.<br />
Ø<br />
Rec.<br />
Hole<br />
L<br />
Noise<br />
Red.<br />
98 140 150 300 45 dB<br />
(Dn,e,w)<br />
98 140 150 400 47 dB<br />
(Dn,e,w)<br />
Item No.<br />
855003<br />
855004<br />
Material:<br />
Noise Reduc.:<br />
Bindex-treated insulation<br />
with plastic coating<br />
Up to 48 dB (Dn,e,w)<br />
Perforated dB Duct<br />
(sound dampening)<br />
Wall duct in perforated<br />
steel with fibreglass liner.<br />
Smooth steel in base prevents<br />
water permeation. Utilises the wall’s<br />
own insulation to provide greater sound<br />
attenuation, so it is unsuitable for<br />
ducts through concrete walls.<br />
Intake Duct Dimensions (mm)<br />
Product<br />
Perf.<br />
dB Duct<br />
Perf.<br />
db Duct<br />
Int.<br />
Ø<br />
Ext.<br />
Ø<br />
Rec.<br />
hole<br />
L<br />
Noise<br />
Red.<br />
98 102 105 200 49 dB<br />
(Dn,e,w)<br />
98 102 105 300 57 dB<br />
(Dn,e,w)<br />
Item No.<br />
858520<br />
858530<br />
Dimensions:<br />
Length:<br />
Material:<br />
Ø98/102 mm<br />
200 or 300 mm<br />
Other lengths upon request<br />
Galvanised sheet metal
<strong>FRESH</strong> Rexus<br />
Supply Air Terminal Device • 4:09<br />
Metal Vent<br />
with Sleeve (round)<br />
Circular exterior wall vent and<br />
sleeve made of sheet metal.<br />
Available in aluminium, copper and<br />
stainless steel. The sleeve is adapted<br />
to Spiro dimensions with press fittings<br />
for secure installation.<br />
Metal Vent with Sleeve<br />
Square vent made of alu-zinc<br />
with plastic sleeve.<br />
The interior sleeve fits<br />
Fresh modular ducts 98/102.<br />
The vent can be lacquered in<br />
any NCS colour as necessary.<br />
Brick Wall Module<br />
Brick wall module for<br />
modular vent 250x65.<br />
The module has a connecting<br />
sleeve 98/102 that fits<br />
Fresh modular ducts 98/102.<br />
The modular vent can be lacquered<br />
in any NCS colour as necessary.<br />
Circular Vent Dimensions (mm)<br />
Product<br />
Vent,sleeve<br />
Ø80/110<br />
Vent,sleeve<br />
Ø100/130<br />
Vent,sleeve<br />
Ø80/110<br />
Vent,sleeve<br />
Ø100/130<br />
Vent,sleeve<br />
Ø80/110<br />
Vent,sleeve<br />
Ø100/130<br />
Conn.<br />
sleeve Ø<br />
Material<br />
Item No.<br />
110 76 Aluminium 440801<br />
130 100 Aluminium 440101<br />
110 76 Copper 440803<br />
130 100 Copper 440103<br />
110 76 Stainless 440807<br />
130 100 Stainless 440107<br />
Square Vent Dimensions (mm)<br />
Product Height Width Dim Ø<br />
Sleeve<br />
Square Vent<br />
alu-zinc<br />
Item No.<br />
120 115 98 449926<br />
Brick Wall Module Dimensions (mm)<br />
Product Height Width Depth Item No.<br />
Brick Module 98 65 250 120 803293<br />
Modular Vent, galv. 65 250 15 803242<br />
Storm Hood (coastal)<br />
The Fresh storm hood is<br />
advantageous in coastal climates<br />
and areas subject to great wind<br />
exposure (tall buildings). On the<br />
façade, the hood provides weather<br />
protection for intake ducts by<br />
effectively preventing rainwater<br />
penetration and substantially<br />
reducing wind effects. The<br />
storm hood also attenuates<br />
some outdoor noise by covering<br />
the wall aperture.<br />
The hood, made of alu-zinc sheet,<br />
can be lacquered in any colour.<br />
Storm Hood Dimensions (mm)<br />
Product Height Width Dim.Ø Item No.<br />
Storm Hood<br />
for wood façades<br />
Rec. coastal areas<br />
Storm Hood<br />
for plaster façades<br />
Rec. coastal areas<br />
Wind Hood<br />
Rec. windy areas<br />
170 150 98 663022<br />
170 165 98 663027<br />
155 145 98 663030<br />
Storm Shield (wind)<br />
In windy conditions, the Fresh<br />
storm shield, installed within the<br />
wall duct, reduces airflow to prevent<br />
excessive ventilation. The storm shield<br />
regulates air supply in strong winds and<br />
shuts completely in storms.<br />
Storm Shield Dimensions (mm)<br />
Product Description Dim.Ø Item No.<br />
Storm Shield<br />
1-way<br />
Storm Shield<br />
1-way<br />
Single-acting w/<br />
backdraught<br />
damper<br />
Single-acting w/<br />
backdraught<br />
damper<br />
81 803272<br />
98 833262
<strong>FRESH</strong> Rexus<br />
Supply Air Terminal Device • 4:10<br />
Fresh TK 300 x 30<br />
TK-dB 300 x 30<br />
Rectangular intake duct in galvanised<br />
steel with dimensions 300 x 30 mm.<br />
Length is telescopically adjustable:<br />
160 - 280 mm or 260 - 480 mm.<br />
The duct is equipped with an insect-proof<br />
vent available with or without dropnose.<br />
Can be concealed under a window ledge.<br />
Also available in a noise-reducing model<br />
for non-bearing walls.<br />
Material:<br />
Noise Reduction<br />
Standard Model:<br />
Noise-Reduc. Model:<br />
Galv. steel<br />
31 dB (Dn,e,w)<br />
50 dB (Dn,e,w)<br />
Intake Duct Dimensions (mm)<br />
Product H W L Noise Red. Item No.<br />
Fresh<br />
TK300x30<br />
Fresh TKdB300x30<br />
Fresh<br />
TK300x30<br />
Fresh TKdB300x30<br />
30 300 160 -<br />
280<br />
30 300 160 -<br />
280<br />
30 300 260 -<br />
480<br />
30 300 260 -<br />
480<br />
Material: Galvanised steel<br />
31 dB<br />
(Dn,e,w)<br />
50 dB<br />
(Dn,e,w)<br />
31 dB<br />
(Dn,e,w)<br />
50 dB<br />
(Dn,e,w)<br />
426203<br />
426202<br />
426218<br />
426219<br />
Fresh ZK-dB R 300 x 30-130<br />
Noise-reducing intake duct for rectangular<br />
connection to the supply air terminal device.<br />
Equipped with pre-bored holes for easy<br />
mounting to a beam behind plasterboard.<br />
Material:<br />
Noise Reduc.:<br />
Wall Thickness:<br />
Height:<br />
Width:<br />
Galv. steel<br />
55 dB (Dn,e,w)<br />
Specified in order<br />
160 mm<br />
300 mm<br />
Insect-proof<br />
Wall thickness, specified in order<br />
30 x 300<br />
130<br />
Cleaning hatch<br />
70 x 300<br />
Opening to air<br />
terminal unit<br />
30 x 300<br />
Connection to air terminal device<br />
30 x 300 mm. Exterior dimensions<br />
300x30 mm with insect-proof vent.<br />
100<br />
Fresh ZK-dB R Ø100-T<br />
Fresh ZK-dB Ø100-T<br />
The Fresh ”swan neck” intake duct is<br />
intended primarily as an inlet to the air<br />
terminal device that can be concealed under<br />
a window ledge. It can also be cleaned easily<br />
from indoors. The section that forms the<br />
wall duct can be telescopically adjusted as<br />
can the section that connects to the air<br />
terminal device. Also available without a<br />
cleaning hatch.<br />
The interior of the duct is equipped with<br />
sound absorbers that provide excellent noise<br />
reduction. The cleaning hatch is made of<br />
white-lacquered aluminium sheet. The duct<br />
is equipped with mounting holes and tabs for<br />
easy installation.<br />
70 x 300<br />
Technical Data<br />
Sound Dampening:<br />
min. 55 dB (Dn,e,w)<br />
(depending on height).<br />
Wall Thickness:<br />
400 - 600<br />
250-350 mm.<br />
Height from top edge of cleaning<br />
hatch to air terminal device:<br />
420-620 mm.<br />
Clean. hatch 300x70 mm.<br />
Exterior dimensions:<br />
300x30 mm with<br />
insect-proof vent.<br />
Connection to air terminal<br />
device: Ø 100 mm.<br />
Made of galvanised steel.<br />
Radiator<br />
base<br />
Cleaning hatch 100 150 - 250<br />
Ø100<br />
50<br />
50<br />
30 x 300<br />
Mounting holes<br />
50 x 300<br />
Mounting<br />
tabs<br />
Vent, with<br />
or without<br />
dropnose
<strong>FRESH</strong> Rexus<br />
Supply Air Terminal Device • 4:11<br />
Acoustic Data<br />
dB<br />
D n,e,w<br />
Quick Pick Table<br />
60<br />
The diagram shows<br />
noise reduction with<br />
a fully-open ventilation<br />
unit and 400 mm<br />
wall. Measurements<br />
according to ISO<br />
140-10. Normalised<br />
sound level difference<br />
for structure,<br />
calculated for 10 m².<br />
50<br />
40<br />
30<br />
20<br />
10<br />
Fresh modulrör Ø98/102<br />
Fresh dB-rör Ø98/148<br />
Fresh TK-dB 300 x 30<br />
Fresh ZK-dB R300 x 30 - 130<br />
Fresh perforerad plåtkanal Ø100<br />
Kanaltyp, väggtjocklek 300 mm<br />
Sound attenuation results for windows and for ventilation<br />
units are calculated through different methods. Their dB<br />
values are therefore not directly comparable.<br />
The same product can yield different results based on the method<br />
used to calculate noise reduction, as shown in this table:<br />
conversion between these based on the same product<br />
Dn,e,w Rw (1.9 m2) De or Ia ΔLA or dB(A)<br />
Normalised sound<br />
level difference for<br />
10 m² wall (dB)<br />
Weighted reduction<br />
coefficient for 2.0 m²<br />
wall (dB).<br />
For 10 m² wall,<br />
same as D<br />
Unit insulation De or<br />
airborne sound index<br />
Ia. Most often for<br />
1.0 m² wall (dB)<br />
A-weighted sound<br />
level difference out-in.<br />
Depends on type of<br />
traffic, wall size and<br />
room size (dB)<br />
48 41 38 40-45<br />
40 33 30 32-37<br />
37 30 27 29-34<br />
In SS 25267, different terms (C;Ctr) are used to account for the<br />
effect of different levels of outdoor noise (SS-EN ISO 717-1). Dn,e,w<br />
+C is used when the sound source is conversational speech, light<br />
auto traffic on residential streets or country roads and train<br />
service. For heavier city traffic, Dn,e,w+Ctr is utilised. The Ctr term<br />
corrects Dn,e,w values for the effect of low-frequency sounds such<br />
as engine noise. The ventilation’s Dn,e,w value should be 10-12 dB<br />
greater than the window’s Rw value.<br />
With two units, the Dn,e,w values should be 3 dB greater.
<strong>FRESH</strong> Rexus<br />
Supply Air Terminal Device • 4:12<br />
Installation<br />
1. Mount the brackets at the appropriate<br />
height in relation to the intake duct with<br />
a minimum c-c of 460 mm between the<br />
brackets. Use Sigarth’s Monclac brackets<br />
(25 mm between wall and radiator). If two<br />
units are mounted on the same radiator,<br />
take this into consideration when placing<br />
the brackets.<br />
2. Unpack the radiator and place it face<br />
down. Image 2.<br />
5. Mount the radiator on its brackets.<br />
Ensure the unit seals against the wall.<br />
6. Place the deflectors on the lower edge<br />
between the panels so they seal against<br />
the cartridge holder. Note: On type 33,<br />
the deflector is mounted between panels<br />
21 and 22.<br />
3. Extend the fresh-air unit to the radiator’s<br />
height and lock it in place with the included<br />
plastic plugs. Holes should be plugged in the<br />
same manner. The unit should be installed<br />
with its bowed edge against the radiator’s<br />
base. Hook the unit to the radiator’s grille<br />
(see image 3). Ensure the unit is placed<br />
correctly relative to the intake duct.<br />
7. To insert the filter cartridge, tilt it slightly<br />
downward and then push it inward and<br />
upward until the front edge seals against<br />
the radiator (see image 7).<br />
Ensure the deflectors fit securely against<br />
the unit between the panels. Protect the<br />
unit from dust, paint and other<br />
contaminants during construction.<br />
4. Type 11 units are mounted with the<br />
included distancing strip.<br />
8. Clean/replace the filter when<br />
construction is complete (see image 6).<br />
An allergen filter (accessory) is inserted<br />
with the reinforced side up atop the<br />
standard filter. The damper should<br />
always be left open.<br />
<strong>FRESH</strong> Phone +46-(0)470-70 77 00<br />
Box 7 Fax +46-(0)470-70 77 39<br />
360 32 Gemla E-mail info@fresh.se<br />
SWEDEN Webb www.fresh.se<br />
Copyright © Fresh 2007 - All rights reserved. - Printed 0702<br />
We reserve the right to make constructional alterations.
<strong>FRESH</strong> AB Tel +46 (0) 470-70 77 00<br />
Box 7 Fax +46 (0) 470-70 77 39<br />
360 32 GEMLA E-mail info@fresh.se<br />
SWEDEN Webb www.fresh.se<br />
AD & Production: Kjell-Olof Askencrantz<br />
Print: Markaryds Grafiska 2007-02<br />
Copyright © Fresh AB 2007