12.03.2015 Views

MEUG12 - Myers Power Products, Inc.

MEUG12 - Myers Power Products, Inc.

MEUG12 - Myers Power Products, Inc.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>MEUG12</strong><br />

Caltrans Type III-AF<br />

Designed to Supply metered or metered/unmetered power to remote locations.<br />

Typical applications include traffic signals, highway and street lighting.<br />

STAND<br />

ANDARD<br />

ARD FEA<br />

EATURES<br />

• Standard voltage 120/240V 1ø 3W.<br />

• Available with all metered circuits or metered/unmetered.<br />

• Meter Socket: 4 jaw 100 amps with test blocks.<br />

• Accommodates maximum 16 breaker poles.<br />

• Main Breaker: 100 amp 10K AIC.<br />

• Utility Landing Lugs: 200 amps.<br />

• Separate deadfronts for breakers and components.<br />

• Vandal-resistant hinged padlockable doors.<br />

• Light green powder coat finish in accordance with ASTM<br />

B-117. Custom colors available.<br />

OPTION<br />

PTIONAL<br />

FEA<br />

EATURES<br />

• Higher AIC available upon request.<br />

• P.E. cells, test switches, lighting relays may be added as<br />

required for job specifications.<br />

• Some equipment modifications available. Consult your<br />

factory representative.<br />

• Also available in aluminum or stainless steel.<br />

• Uni-body construction available in steel, stainless steel,<br />

and aluminum.<br />

• Anchor Bolts. Order separately - 714548 (quantity 4)<br />

SPECIFICA<br />

PECIFICATIONS<br />

• 12 gauge corrosion resistant zinc coated steel<br />

construction. Hood and covers 14 gauge.<br />

• Rainproof Type 3R enclosure.<br />

• Complies with Caltrans specification ES-2D.<br />

• Meets EUSERC 308 requirements.<br />

• All factory wiring is 600 volt rated copper.<br />

• Acceptable circuit breakers are GE, ITE, Crouse-Hinds/<br />

Murray, Cutler Hammer.<br />

• Suitable for use without main when no more than six<br />

service disconnects are installed and used in accordance<br />

with article 384 of the NEC.<br />

• Listed by Underwriters Laboratories, <strong>Inc</strong>.<br />

1/31/05


Tel: 866-MY-MYERS Fax: 951-520-1961<br />

www.myerspowerproducts.com<br />

Specifications are subject to change without notice to reflect improvements and upgrades.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!