TELECOMMUNICATIONS TEST EQUIPMENT - Promax
TELECOMMUNICATIONS TEST EQUIPMENT - Promax
TELECOMMUNICATIONS TEST EQUIPMENT - Promax
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
PROMAX-8+<br />
CABLE TV ANALYSER<br />
Outbox data processing<br />
RM-008 software package is a perfect complement<br />
to thePROMAX-8+. Three different menus<br />
on the PC computer screen allows to configure<br />
any paremeter in the PROMAX-8+, to send<br />
individual commands and set Data Logger<br />
information.<br />
This program has three main function:<br />
a) Datalogger: Allows to open stored Data<br />
Loggers in the PROMAX-8+ (up to a maximum<br />
of 55) or transfer a Data Logger acquisition from<br />
the PROMAX-8+ to the PC.<br />
also enables the modification of the Channel Plan<br />
Groups. A Channel Plan Group is a set of Channel<br />
Plans we can store in a PROMAX-8+, i.e. standard<br />
factory channel Plan Group is made up of the<br />
following channel plans: CCIR, CCIRUK, EIA,<br />
FCC, OIRL and STD2L. The channel plan group<br />
maximum size is 10 channel plans composed of<br />
140 channels each. The config menu permits the<br />
selection of the communication path, the communication<br />
port and to exit the program.<br />
c) Upgrade: Allows to upgrade the PROMAX-8+<br />
internal control software to newer versions.<br />
Minimum requirement to use the program<br />
b) Config: Allows to transmit, receive, save and<br />
modify all the Configuration Parameters of the<br />
PROMAX-8+. The different parameters are grouped<br />
into six areas according to the operating mode<br />
they affect (Channel-Frequency, Data Logger,<br />
Scan, Tilt, Spectrum analyser, Global). This menu<br />
correctly are needed. An IBM-compatible computer<br />
486 or higher with 10 Mbytes available on the<br />
hard disk (variable, depending on the files of data<br />
available), mouse (not essential, but highly recommeded)<br />
and serial por COM1 or COM2 available.<br />
RM-008+ software runs under Window 95/98 .<br />
SPECIFICATIONS<br />
Tuning<br />
Tuning range<br />
Tuning mode<br />
Channel plan<br />
Frequency<br />
Indication<br />
PROMAX-8+<br />
From 5 to 862 MHz<br />
By channels or by frequency<br />
Selectable<br />
For fine tuning. 10 kHz resolution<br />
Graphic display with backlight<br />
Level measurement<br />
Measurement range From 25 to 120 dBmV (from-35 dBmV to 60<br />
dBmV)<br />
Reading<br />
Digital in dBµV, dBmV o dBm and analogue by<br />
Graphic display with backlight. 1dB Resolution<br />
IF Bandwidth<br />
230 kHz ± 50 kHz<br />
Input impedance<br />
75 W<br />
Audible indication A tone varies with the signal level<br />
Accuracy<br />
Analogue Channels± 2 dB (from 0 to 40º C)<br />
Negative video modulation)<br />
Digital Channels± 3 dB (from 0 to 40º C)<br />
For 8MHz channel bandwidth<br />
CSO-CTB Intermodulation<br />
(Analogue channels)<br />
CSO<br />
Ratio of the peak level of the video carrier to the<br />
peak of the distortion products of second order<br />
beat. Measured at four frequencies user definable.<br />
Measuring frequency From -2.50 to - 0.50 MHz and from 0.50 to 2.50<br />
MHz (Default values -1.5, -0.5, +0.5 y + 1.5 MHz).<br />
CTO<br />
Ratio of the peak level of the video carrier to the<br />
peak of the distortion products of third order beat.<br />
Measured at the carrier frequency or, approximately<br />
mode, in a channel previously defined by the user.<br />
Data logger function<br />
Max. number of loggers55<br />
Number of channels/logger 140<br />
Measurements<br />
Analogue channelsLevel, C/N and V/A<br />
Digital channelsChannel power<br />
Sound<br />
Demodulation<br />
Output<br />
AM / FM<br />
Internal speaker / External headphone<br />
Video/Audio<br />
Measurement<br />
Range<br />
Audio subcarrier frequency<br />
Variable<br />
Accuracy<br />
Carrier / Noise<br />
Measurement<br />
Audio and Video level carrier ratio<br />
From 0 to 40 dB<br />
4-9 MHz<br />
± 2 dB (from 0 to 40 ºC) for FM carrier<br />
Carrier to Noise level ratio measured within<br />
required channel<br />
Measurement range<br />
Analogue channels38 - 48 dB (for input level between 60 and 70<br />
dBmV)<br />
> 48 dB for input level > 70 dBmV<br />
Digital channels> 40 dB for input level >60 dBmV<br />
Accuracy<br />
± 2 dB (45-862 MHz) ± 3 dB (5-45 MHz)<br />
Transient detector<br />
Detection threshold<br />
Detection range<br />
Detection range<br />
Power requirements<br />
Battery<br />
Low battery<br />
Auto power off<br />
Battery charger<br />
Mechanical features<br />
Dimensions<br />
Weight<br />
From 20 to 60 dBmVin steps of 1 dB<br />
From 5 to 100 MHz maximum<br />
Number of detected transitory in the<br />
measuring time. Present detected level and<br />
maximum detected level in the time of the<br />
measurement<br />
7,2 V<br />
Display indication<br />
Automatic power of after few minutes whitout<br />
operation<br />
By external fast charger<br />
W. 70 (90 at display) x H..218 x D.50 mm<br />
580 g. (battery included)<br />
15