13.03.2015 Views

TELECOMMUNICATIONS TEST EQUIPMENT - Promax

TELECOMMUNICATIONS TEST EQUIPMENT - Promax

TELECOMMUNICATIONS TEST EQUIPMENT - Promax

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ACCESSORIES<br />

LN-370B Low noise amplifier<br />

The LN-370B is a low noise amplifier which allows the dynamic range of<br />

spectrum analysers and level meters to be extended, to measure weak amplitude<br />

signals.<br />

SPECIFICATIONS<br />

LN-370B<br />

Frequency range<br />

10-2050 MHz<br />

Gain<br />

20 dB ± 2 dB<br />

Flatness<br />

± 1 dB (10-1000 MHz)<br />

±2.5 dB (1000-2050 MHz)<br />

Maximum input level 70 dBµV<br />

Input impedance 50 W (VSWR max. 2:1)<br />

Input connector<br />

BNC female<br />

Output impedance 50 W (VSWR max. 3.5:1)<br />

Output connector<br />

BNC male<br />

Power supply<br />

12 - 18 V (auxiliary connector or input<br />

connector or output connector)<br />

Consumption<br />

25 mA max.<br />

Max. cuurent (no damage) 400 mA<br />

PC-108 Polarizer controller<br />

The PC-108 is a polarizer controller able to drive all type of magnetic polarizers. It is powered through<br />

the input connector without breaking the LNB supply.<br />

SPECIFICATIONS<br />

Voltage<br />

Current variation range<br />

Insertion losses<br />

PC-108<br />

12 to 18 V<br />

From -140 to 140 mA max<br />

< 2 dB (950 - 2050 MHz)<br />

CV-550 Sub-band converter<br />

El CV-550 is a converter from sub-band to VHF so that these sub-band channels can be measured with<br />

standard TV / FM level meters not including coverage for that frequency range as a standard.<br />

SPECIFICATIONS<br />

CV-550<br />

Input frequency range<br />

From 5 to 50 MHz<br />

Conversion loss<br />

0 dB ± 1 dB<br />

Maximum input level 130 dBµV (40 dB attenuator )<br />

Power supply<br />

Internal battery<br />

External 12-18 V<br />

Through output connector<br />

NG-281/NG-282 Noise Generators<br />

The NG-281/NG-282 noise generators are large bandwidth devices especially designed for application in all kinds of television installations, whether terrestrial,<br />

cable or satellite distribution.<br />

Powered by battery or mains adapter, they enable the user to perform measurements in combination with field level meters or spectrum analysers in highly<br />

complex installations. Obtaining the frequency responses of active and passive circuits, measuring impedance adaptation and the relation of standing waves in<br />

combination with a reflection bridge, and the detection of anomalies in transmission lines, are some of the functions where NG-281/NG-282 noise generators are<br />

of great assistance.<br />

SPECIFICATIONS NG-282 NG-281<br />

Frequency range 20-2000 MHz 5-1000 MHz<br />

Output level 50 dBµV ( 70 dBmV (300 kHz bandwidth)<br />

Frequency response<br />

5-1000 MHz ±2 dB<br />

20-1000 MHz ± 2 dB<br />

1000-2000 MHz ± 3 dB<br />

Output impedance 75 W 75 W<br />

Internal supply 6F22 9V battery 9V NiCd CB037 battery<br />

Battery life 1.5 h at 30% on / off operation 1.5 h at 30 % on / off operation<br />

(alkaline battery)<br />

(alkaline battery)<br />

External supply<br />

Voltage range 12 to 18 V DC 11 to 18 VDC<br />

Consumption 200 mA maximum 100 mA maximum<br />

Dimensions W.72 x H.35 x D.121 mm W.72 x H.35 x D.121 mm<br />

Weight 200 g 200 g<br />

24

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!