<strong>Technical</strong> <strong>data</strong><br />

AP100<br />

AP100<br />

The pumps are used for pumping sewage, wastewater,<br />

considerable quantities of surface water and ground<br />

water in places such as<br />

• municipal pump pits,<br />

• public buildings,<br />

• block of flats,<br />

• factories,<br />

• garages,<br />

• underground car-parks,<br />

• car wash areas,<br />

• restaurants and<br />

• hotels.<br />

Pump and stator housing<br />

The pump housing and the stator housing are made of<br />

cast iron.<br />

The stator housing is dry, i.e. not oil-filled.<br />

Discharge<br />

All AP100 pumps have a horizontal discharge port.<br />

AP100.100 have a DN 100 DIN flange.<br />

AP100.150 have a DN 150 DIN flange.<br />

Shaft and bearings<br />

The shaft is made of stainless steel and rotates in maintenance-free<br />

prelubricated ball bearings.<br />

The lower bearing is a double-row ball bearings.<br />

Impeller<br />

The impeller is a closed single-channel or two-channel<br />

cast iron impeller with a clearance of 100 mm. Cast iron<br />

is chosen as it is resistant towards mechanically wearing<br />

particles.<br />

TM00 5488 0895<br />

Shaft seal<br />

Two mechanical bellows seals with silicon carbide/<br />

silicon carbide seal faces.<br />

An oil chamber between the primary and the secondary<br />

shaft seal is filled with oil.<br />

Pump type<br />

AP100.100.24 - 61<br />

AP100.100.80 - 135<br />

AP100.150.80 - 170<br />

Motor cable<br />

Standard pumps 10 m:<br />

Ex-pumps 10 m:<br />

Materials<br />

Cooling jacket<br />

H07RNF.<br />

H07RNF - PLUS.<br />

Oil volume<br />

1.7 litres<br />

3 litres<br />

3 litres<br />

Description<br />

Materials<br />

DIN<br />

W.-Nr.<br />

AISI/ASTM<br />

Stator housing Cast iron EN-GJL-250 0.6025 ASTM 35B<br />

Pump housing Cast iron EN-GJL-250 0.6025 ASTM 35B<br />

Neck ring<br />

Bronze<br />

Impeller Cast iron EN-GJL-250 0.6025 ASTM 35B<br />

Shaft Stainless steel 1.4104 AISI 430F<br />

Bearings<br />

Heavy-duty prelubricated ball bearings<br />

Screws Stainless steel 1.4301 AISI 304<br />

Cooling jacket Stainless steel 1.4301 AISI 304<br />

Oil<br />

Shell Ondina 15, non-toxic<br />

On request all AP100 pumps can be supplied fitted with<br />

a stainless steel cooling jacket.<br />

Liquid temperature with cooling jacket: 0°C to +40°C.<br />

For short periods, max. one hour: Up to +60°C. For<br />

periods longer than one hour, external cooling is<br />

required.<br />

The cooling jacket is available for internal as well as<br />

external cooling of the motor in both dry and submerged<br />

installations.<br />

Internal cooling (standard) is achieved by leading part of<br />

the pumped liquid around the stator housing and back<br />

to the pump housing via internal channels.<br />

For external cooling the cooling jacket is fitted with<br />

sockets for pipe connections.<br />

The cooling jacket is required for cooling of the motor in<br />

dry installations, and in submerged installations if the<br />

pump is not completely submerged during continuous<br />

operation.<br />

The inlet side of the pump housing is fitted with a<br />

replaceable neck ring.<br />