22.03.2015 Views

Catalog - Da Miano & Graham

Catalog - Da Miano & Graham

Catalog - Da Miano & Graham

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

“A Century of Dependability”<br />

Portable Foam Eductors<br />

Portable Foam Eductors<br />

See Eductor<br />

Performance Chart<br />

on Page 81<br />

Features:<br />

• Rugged, Corrosion Resistant Brass Construction<br />

• 1/2% Setting for Class A Foam*<br />

• Simple, Efficient Venturi Design<br />

• Inline or By-pass Models*<br />

• 1, 3, & 6% Settings for Class B foam*<br />

• Positive Setting Positions*<br />

• Removable Metering Valve<br />

• Clear PVC Pickup Hose – .625" ID x 1.0" OD<br />

• Removable Pickup Screen<br />

• Wide Selection of Flows*<br />

• Stainless Steel Check Ball*<br />

By-Pass Eductors<br />

240-60 By-Pass Foam Eductor<br />

60 GPM flow • By-pass allows for water only operations at lower inlet pressures • Positive<br />

setting metering valve (0, 1/2, 1, 3, & 6%) • 1.5" or 2.5" NHT free swivel inlet (please specify)<br />

• 1.5" NHT male outlet • Finish red urethane enamel with chrome plated trim • Length, 17.25" •<br />

Weight, 20.5 lbs.<br />

240-95 By-Pass Foam Eductor<br />

Same as 240-60 except 95 GPM flow.<br />

240-125 By-Pass Foam Eductor<br />

Same as 240-60 except 125 GPM flow.<br />

Inline Eductors<br />

241-30 Inline Foam Eductor (Not Shown)<br />

30 GPM flow • Infinite setting metering valve (0 thru 6%) • 1.0" or 1.5" NHT free swivel inlet<br />

(please specify) • 1" NHT male outlet • Finish red urethane enamel with chrome plated trim •<br />

Length, 8.375" • Weight, 4.5 lbs.<br />

241-60 Inline Foam Eductor<br />

60 GPM flow • Positive setting metering valve (0, 1/2, 1, 3, & 6%) • 1.5" or 2.5" NHT free swivel inlet<br />

(please specify) • 1.5" NHT male outlet • Finish red urethane enamel with satin brass or chrome<br />

plated trim (please specify) • Length, 11.75" • Weight, 9.5 lbs.<br />

241-95 Inline Foam Eductor<br />

Same as 241-60 except 95 GPM flow.<br />

241-125 Inline Foam Eductor<br />

Same as 241-60 except 125 GPM flow.<br />

241-150 Inline Foam Eductor<br />

Same as 241-60 except 150 GPM flow.<br />

241-250 Inline Foam Eductor<br />

Similar to 241-60 except 250 GPM, a 2.5"<br />

NHT free swivel inlet, and a 2.5" NHT male<br />

outlet • Length, 16" • Weight, 16.75 lbs.<br />

241-N3 Inline Foam Eductor<br />

90 GPM flow • Single percentage metering<br />

valve (3%) • 1.5" NPSH swivel inlet and<br />

1.5" NPSH male outlet • Cast brass finish<br />

• Length, 10" • Weight, 5.75 lbs.<br />

241-N6 Inline Foam Eductor<br />

Same as 241-N3 except 6% metering.<br />

Benefits:<br />

• Years of Dependable Service<br />

• Easy Hook-up/Easy Set-up<br />

• Trouble-free Operation<br />

• Compatible with Most Foam Concentrates<br />

• A Size for All Handlines: 1" thru 3"<br />

• Cost Effective Class A Foam System<br />

• Can be deployed in any position<br />

• Elkhart Quality<br />

Infinite Setting Valve<br />

Operating Pressure for Eductors<br />

These eductors are designed to achieve rated flow<br />

with an inlet pressure of 200 psi. They will operate at<br />

lower inlet pressures than this, but the flow rate and<br />

percentage rate will be effected (see chart on page 81).<br />

For more technical information on these eductors, call<br />

for our operating and maintenance instructions (Form<br />

No. EB-98069).<br />

Check List if Eductor Fails to Pick Up Foam<br />

These eductors are very basic in design and very<br />

easy to operate. However, there are many other<br />

conditions and situations that can cause the eductor<br />

to fail in picking up foam concentrate. If this happens<br />

check the following:<br />

✔ Mismatched nozzle<br />

✔ Partially closed nozzle<br />

✔ Clogged nozzle<br />

Metering Valves<br />

Positive Setting Valve<br />

✔ Ball check stuck<br />

✔ Metering valve clogged<br />

✔ Plugged pick up screen<br />

✔ Hose lay too long ✔ Metering valve set<br />

✔ Metering valve closed improperly<br />

✔ Nozzle elevated too high ✔ Kink in hose<br />

✔ By-pass valve open<br />

*These features not applicable to 241-N3 and 241-N6.