SITRANS F M MAG 8000 Product introduction - Aquatechtrade
SITRANS F M MAG 8000 Product introduction - Aquatechtrade
SITRANS F M MAG 8000 Product introduction - Aquatechtrade
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
s<br />
Aquatech India 2012<br />
“<strong>MAG</strong> <strong>8000</strong> Battery Magmeter to Solve Water Resources"<br />
page 1<br />
Group / Region / Department
s<br />
SC Sensor and Communication<br />
Dipl.- Wirtsch.- Ing.<br />
Stephan Mimler<br />
Siemens AG<br />
Industry Sector<br />
Industry Automation Division<br />
Sensors and Communication<br />
I IA SC S PI 1<br />
Oestliche Rheinbrueckenstr. 50<br />
76187 Karlsruhe, Germany<br />
Tel.: +49 721 595-6846<br />
Fax: +49 721 595-6859<br />
Mobile: +49 173 2783536<br />
mailto:stephan.mimler@siemens.com<br />
- more than 20 years experience<br />
in instrumentation and<br />
international business<br />
page 2<br />
Group / Region / Department
s<br />
<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />
Battery-operated electromagnetic water meter<br />
• Low-powered transmitter on volume<br />
produced sensor program<br />
• Developed after OIML R 49 – global water<br />
meter specification, conforms with European<br />
CEN EN 14154 and ISO 4064<br />
• Unique 6 years operation on internal<br />
battery pack<br />
Internal 6-year<br />
life battery pack<br />
Mains power<br />
supply<br />
Mains power with<br />
up to 3 years<br />
battery back-up<br />
External 10-year<br />
life battery pack<br />
page 3<br />
Group / Region / Department
s<br />
<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />
Supports “Lose less. Keep more”<br />
Distribution Network: Optimize water supply & reduce leakage<br />
Bulk water/revenue metering : Accurate billing & monitoring consumption<br />
Irrigation: Ensure long-term performance for optimal ownership<br />
Lose Less.<br />
Keep More.<br />
<strong>SITRANS</strong> F M<br />
<strong>MAG</strong> <strong>8000</strong><br />
page 4<br />
Group / Region / Department
s<br />
<strong>MAG</strong> <strong>8000</strong> Benefit <strong>MAG</strong> <strong>8000</strong> vers. mech. Water meter<br />
• Long-term stability<br />
• No wearing parts<br />
• No pressure loss<br />
• Lower installation costs<br />
• Separate electronics for wall assembly<br />
• Datenlogger and Self-monitoring of electronics<br />
page 5<br />
Group / Region / Department
s<br />
<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />
Benefits<br />
• Locations without power<br />
• Water metering<br />
• Leak detection<br />
• Can be moved to different locations as needed<br />
• Advanced diagnostic functions<br />
• Proven accuracy at Violia Water up to 15 m/s<br />
• Conductivity from 20 µS<br />
• Cables pre-mounted from factory<br />
• GSM solution<br />
Lose Less.<br />
Keep More.<br />
<strong>SITRANS</strong> F M<br />
<strong>MAG</strong> <strong>8000</strong><br />
page 6<br />
Group / Region / Department
s<br />
<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />
Benefits<br />
• Precise Metering<br />
• Easy to install<br />
• Ownership - Long lasting performance<br />
• Intelligent Information – Easy to access<br />
The water meter of choice for water supply and metering<br />
page 7<br />
Group / Region / Department
s<br />
<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />
Simple to install<br />
• No mains power needed – internal battery pack<br />
power operation for typical 6 years<br />
• Just bolts in place and water in the pipe and<br />
precise metering is delivered<br />
• No filter required<br />
No additional<br />
connection or<br />
set-up required<br />
to operate the<br />
meter<br />
page 8<br />
Group / Region / Department
s<br />
<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />
Simple to install<br />
• Compact/remote with factory mounted sensor cables with connectors<br />
• IP68/NEMA 6P enclosure withstands flooding in underground<br />
installation<br />
• Insensitive installation with limit inlet and outlet installation<br />
requirements<br />
page 9<br />
Group / Region / Department
s<br />
<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />
Superior Measurement<br />
• Bi-directional measurement with maximum uncertainty of<br />
• 0.4% of flow rate 2 mm/s (DN 25 to DN 1200) Standard calibration<br />
• 0.2% of flow rate 2 mm/s (DN 50 to DN 300) Extended calibration<br />
• Measurement of media contact and impedance<br />
• 2 totalizers on forward, reverse or net flow and customer totalizer with own reset<br />
page 10<br />
Group / Region / Department
s<br />
<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />
Superior Measurement<br />
One cone down, internal in sensor<br />
for better low flow detection with<br />
insignificant pressure drop<br />
No moving parts means<br />
independent against particles in<br />
water – ensuring high repeatability<br />
of maximum uncertainty 0.1%<br />
page 11<br />
Group / Region / Department
s<br />
<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />
Long lasting Performance<br />
• Maintenance-free for optimal up time<br />
• No moving parts that wear and tear - delivering long term performance<br />
• Robust construction built to resist environmental influence:<br />
- Flooding: IP68/NEMA 6P<br />
- Low and high temperatures: -20 °C to +60 °C (-4°F to +140°F)<br />
- Corrosion<br />
Robust construction<br />
built to resist<br />
environmental<br />
influence<br />
page 12<br />
Group / Region / Department
s<br />
<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />
Minimum Cost of Ownership<br />
• One water meter for all water application<br />
• Performance for leakage detection and correct billing replacing two<br />
meters in real installation<br />
• Minimal stock and product knowledge and support<br />
• Build-in self-check program<br />
• Password and hardware data protection with back-up<br />
• Totaliser 1 and 2, date and time (each 10 minutes)<br />
• Operation time (each 1 hours)<br />
• Power consumption (each 4 hours)<br />
page 13<br />
Group / Region / Department
s<br />
<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />
Intelligent Information<br />
Internal data logger for logging of water consumption, alarms and meter<br />
operation status. Logging period selectable as day, week or month with<br />
up to 26 months data recording<br />
Consumption alarm with ”call-up” functionality via pulse output, based on<br />
customer selected alarm levels on too high, or too low consumption<br />
page 14<br />
Group / Region / Department
s<br />
<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />
Intelligent Information<br />
Advanced alarm monitoring and registration<br />
• Hours alarm has been active<br />
• Numbers of time alarm has occurred<br />
• First / last time the alarm appeared - disappeared<br />
• Total hours the measurement have been affected<br />
”Call-up” from site to reduce<br />
site visit (via pulse output)<br />
page 15<br />
Group / Region / Department
s<br />
<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />
Intelligent Information<br />
Tamper securing by monitoring<br />
of revenue data and meter<br />
operation showing if data has<br />
been manipulated.<br />
Real time clock with date and<br />
time registration on change of<br />
important information.<br />
Customer identification, number<br />
and meter location.<br />
page 16<br />
Group / Region / Department
s<br />
<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT Advanced Version<br />
Leakage Detection<br />
24h<br />
lowest value<br />
Flow/volume<br />
Time window<br />
Leakage before alarm<br />
!-1<br />
!-2<br />
!-3<br />
Reset<br />
!-5<br />
Leakage<br />
level<br />
Min. & max. flow or volume<br />
Counter<br />
24h<br />
page 17<br />
Group / Region / Department
s<br />
<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT Advanced Version<br />
Meter Utilizations<br />
6 free selectable intervals. Counting hours of flow inside each interval<br />
Q3 (Qn) = 100%<br />
Flow 6<br />
Flow 5<br />
Flow 4<br />
Flow 3<br />
Oversize meter<br />
Flow 2<br />
Flow 1<br />
Time (H)<br />
page 18<br />
Group / Region / Department
s<br />
<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT Advanced Version<br />
Consumption Profile<br />
6 free selectable profile intervals (tariff program)<br />
Profile on flow rate (Q3), a combination/or time<br />
Profile 6<br />
Profile 5<br />
Profile 4<br />
Profile 3<br />
Profile 2<br />
Profile 1<br />
Consumption (m 3 )<br />
page 19<br />
Group / Region / Department
s<br />
<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT Advanced<br />
Flow Statistics<br />
• Lowest and highest flow with date and time registration<br />
• Lowest and highest consumption per day with date registration<br />
• Consumption the latest 7 days, with consumption register<br />
for each day<br />
• Actual month consumption and last month<br />
page 20<br />
Group / Region / Department
<strong>SITRANS</strong> FM <strong>MAG</strong> <strong>8000</strong> GSM/GPRS<br />
Wireless Module<br />
s<br />
• The <strong>MAG</strong> <strong>8000</strong> WCM is a wireless<br />
communication module based on the<br />
GSM / GPRS technology.<br />
• The WCM is built in system to avoid<br />
compromise the IP 68 protection degree<br />
on the <strong>MAG</strong> <strong>8000</strong><br />
• Optional two analog inputs<br />
- One standard 4 – 20 mA (externally powered)<br />
- One ratiometric input 5 VDC powered by the<br />
<strong>MAG</strong> <strong>8000</strong><br />
• No proprietary SW require to get<br />
access to the data<br />
page 21<br />
Group / Region / Department
s<br />
<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />
Flow Tool Configuration Software<br />
Free download from Internet via standard<br />
IrDA connection to PC<br />
Flow Tool Purpose<br />
• Commissioning – equal setting of<br />
meters<br />
• Data print out for documentation<br />
• Data export as CSV file<br />
• Online with meter – Offline for<br />
preparing setting<br />
• Password – Hardware lock<br />
• Own parameter list<br />
• Service – transmitter replacement<br />
page 22<br />
Group / Region / Department
s<br />
<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />
<strong>Product</strong> Program<br />
• Compact – remote meter with 5 m, 10 m, 20 m and<br />
30 m sensor cable with plugs<br />
• Factory mounted I/O cable<br />
• Flanges EN1092-1, ANSI CL150, AS4087<br />
• Standard accuracy of 0.4% or 0.2%<br />
page 23<br />
Group / Region / Department
s<br />
<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />
Installed Base – More than 15,000 units installed globally<br />
• United Kingdom<br />
• Australia<br />
• US<br />
• France<br />
• Spain<br />
• Italy<br />
• Qatar<br />
• Denmark<br />
• Germany<br />
• Netherlands<br />
• Malaysia<br />
• Thailand<br />
• Poland<br />
• Canada<br />
• Portugal<br />
• Philippines<br />
• South Africa<br />
• Mexico<br />
• UAE<br />
• China<br />
• India<br />
Main reference installation of<br />
460 units for district monitoring<br />
page 24<br />
Group / Region / Department
s<br />
<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />
Typical Applications – Storm Water Metering - WWW<br />
Company: Himmark Purification Plant<br />
Location: Nordborg, Denmark<br />
Task: Storm water metering<br />
Why <strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong><br />
- The municipality already had 5 conventional<br />
<strong>MAG</strong> 5100 W meters installed in their plant and they<br />
were all 5 performing very well.<br />
- The <strong>MAG</strong> <strong>8000</strong> water meter is easy to integrate and<br />
as the meter is battery-driven, the installation costs<br />
are very low.<br />
- The built-in data logger means that all measurement<br />
data can be read on a computer screen – it<br />
considerably reduces the time it takes to inspect and<br />
read the meter.<br />
page 25<br />
Group / Region / Department
s<br />
<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />
Installed base<br />
1) Violia Water test<br />
laboratories<br />
2) Irrigation application<br />
3 + 4) District monitoring<br />
application in Denmark<br />
1 2<br />
3 4<br />
page 26<br />
Group / Region / Department
s<br />
Thank you<br />
very much<br />
Protection notice / Copyright notice