s<br />

Aquatech India 2012<br />

“<strong>MAG</strong> <strong>8000</strong> Battery Magmeter to Solve Water Resources"<br />

page 1<br />

Group / Region / Department


s<br />

SC Sensor and Communication<br />

Dipl.- Wirtsch.- Ing.<br />

Stephan Mimler<br />

Siemens AG<br />

Industry Sector<br />

Industry Automation Division<br />

Sensors and Communication<br />

I IA SC S PI 1<br />

Oestliche Rheinbrueckenstr. 50<br />

76187 Karlsruhe, Germany<br />

Tel.: +49 721 595-6846<br />

Fax: +49 721 595-6859<br />

Mobile: +49 173 2783536<br />

mailto:stephan.mimler@siemens.com<br />

- more than 20 years experience<br />

in instrumentation and<br />

international business<br />

page 2<br />

Group / Region / Department


s<br />

<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />

Battery-operated electromagnetic water meter<br />

• Low-powered transmitter on volume<br />

produced sensor program<br />

• Developed after OIML R 49 – global water<br />

meter specification, conforms with European<br />

CEN EN 14154 and ISO 4064<br />

• Unique 6 years operation on internal<br />

battery pack<br />

Internal 6-year<br />

life battery pack<br />

Mains power<br />

supply<br />

Mains power with<br />

up to 3 years<br />

battery back-up<br />

External 10-year<br />

life battery pack<br />

page 3<br />

Group / Region / Department


s<br />

<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />

Supports “Lose less. Keep more”<br />

Distribution Network: Optimize water supply & reduce leakage<br />

Bulk water/revenue metering : Accurate billing & monitoring consumption<br />

Irrigation: Ensure long-term performance for optimal ownership<br />

Lose Less.<br />

Keep More.<br />

<strong>SITRANS</strong> F M<br />

<strong>MAG</strong> <strong>8000</strong><br />

page 4<br />

Group / Region / Department


s<br />

<strong>MAG</strong> <strong>8000</strong> Benefit <strong>MAG</strong> <strong>8000</strong> vers. mech. Water meter<br />

• Long-term stability<br />

• No wearing parts<br />

• No pressure loss<br />

• Lower installation costs<br />

• Separate electronics for wall assembly<br />

• Datenlogger and Self-monitoring of electronics<br />

page 5<br />

Group / Region / Department


s<br />

<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />

Benefits<br />

• Locations without power<br />

• Water metering<br />

• Leak detection<br />

• Can be moved to different locations as needed<br />

• Advanced diagnostic functions<br />

• Proven accuracy at Violia Water up to 15 m/s<br />

• Conductivity from 20 µS<br />

• Cables pre-mounted from factory<br />

• GSM solution<br />

Lose Less.<br />

Keep More.<br />

<strong>SITRANS</strong> F M<br />

<strong>MAG</strong> <strong>8000</strong><br />

page 6<br />

Group / Region / Department


s<br />

<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />

Benefits<br />

• Precise Metering<br />

• Easy to install<br />

• Ownership - Long lasting performance<br />

• Intelligent Information – Easy to access<br />

The water meter of choice for water supply and metering<br />

page 7<br />

Group / Region / Department


s<br />

<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />

Simple to install<br />

• No mains power needed – internal battery pack<br />

power operation for typical 6 years<br />

• Just bolts in place and water in the pipe and<br />

precise metering is delivered<br />

• No filter required<br />

No additional<br />

connection or<br />

set-up required<br />

to operate the<br />

meter<br />

page 8<br />

Group / Region / Department


s<br />

<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />

Simple to install<br />

• Compact/remote with factory mounted sensor cables with connectors<br />

• IP68/NEMA 6P enclosure withstands flooding in underground<br />

installation<br />

• Insensitive installation with limit inlet and outlet installation<br />

requirements<br />

page 9<br />

Group / Region / Department


s<br />

<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />

Superior Measurement<br />

• Bi-directional measurement with maximum uncertainty of<br />

• 0.4% of flow rate 2 mm/s (DN 25 to DN 1200) Standard calibration<br />

• 0.2% of flow rate 2 mm/s (DN 50 to DN 300) Extended calibration<br />

• Measurement of media contact and impedance<br />

• 2 totalizers on forward, reverse or net flow and customer totalizer with own reset<br />

page 10<br />

Group / Region / Department


s<br />

<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />

Superior Measurement<br />

One cone down, internal in sensor<br />

for better low flow detection with<br />

insignificant pressure drop<br />

No moving parts means<br />

independent against particles in<br />

water – ensuring high repeatability<br />

of maximum uncertainty 0.1%<br />

page 11<br />

Group / Region / Department


s<br />

<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />

Long lasting Performance<br />

• Maintenance-free for optimal up time<br />

• No moving parts that wear and tear - delivering long term performance<br />

• Robust construction built to resist environmental influence:<br />

- Flooding: IP68/NEMA 6P<br />

- Low and high temperatures: -20 °C to +60 °C (-4°F to +140°F)<br />

- Corrosion<br />

Robust construction<br />

built to resist<br />

environmental<br />

influence<br />

page 12<br />

Group / Region / Department


s<br />

<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />

Minimum Cost of Ownership<br />

• One water meter for all water application<br />

• Performance for leakage detection and correct billing replacing two<br />

meters in real installation<br />

• Minimal stock and product knowledge and support<br />

• Build-in self-check program<br />

• Password and hardware data protection with back-up<br />

• Totaliser 1 and 2, date and time (each 10 minutes)<br />

• Operation time (each 1 hours)<br />

• Power consumption (each 4 hours)<br />

page 13<br />

Group / Region / Department


s<br />

<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />

Intelligent Information<br />

Internal data logger for logging of water consumption, alarms and meter<br />

operation status. Logging period selectable as day, week or month with<br />

up to 26 months data recording<br />

Consumption alarm with ”call-up” functionality via pulse output, based on<br />

customer selected alarm levels on too high, or too low consumption<br />

page 14<br />

Group / Region / Department


s<br />

<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />

Intelligent Information<br />

Advanced alarm monitoring and registration<br />

• Hours alarm has been active<br />

• Numbers of time alarm has occurred<br />

• First / last time the alarm appeared - disappeared<br />

• Total hours the measurement have been affected<br />

”Call-up” from site to reduce<br />

site visit (via pulse output)<br />

page 15<br />

Group / Region / Department


s<br />

<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />

Intelligent Information<br />

Tamper securing by monitoring<br />

of revenue data and meter<br />

operation showing if data has<br />

been manipulated.<br />

Real time clock with date and<br />

time registration on change of<br />

important information.<br />

Customer identification, number<br />

and meter location.<br />

page 16<br />

Group / Region / Department


s<br />

<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT Advanced Version<br />

Leakage Detection<br />

24h<br />

lowest value<br />

Flow/volume<br />

Time window<br />

Leakage before alarm<br />

!-1<br />

!-2<br />

!-3<br />

Reset<br />

!-5<br />

Leakage<br />

level<br />

Min. & max. flow or volume<br />

Counter<br />

24h<br />

page 17<br />

Group / Region / Department


s<br />

<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT Advanced Version<br />

Meter Utilizations<br />

6 free selectable intervals. Counting hours of flow inside each interval<br />

Q3 (Qn) = 100%<br />

Flow 6<br />

Flow 5<br />

Flow 4<br />

Flow 3<br />

Oversize meter<br />

Flow 2<br />

Flow 1<br />

Time (H)<br />

page 18<br />

Group / Region / Department


s<br />

<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT Advanced Version<br />

Consumption Profile<br />

6 free selectable profile intervals (tariff program)<br />

Profile on flow rate (Q3), a combination/or time<br />

Profile 6<br />

Profile 5<br />

Profile 4<br />

Profile 3<br />

Profile 2<br />

Profile 1<br />

Consumption (m 3 )<br />

page 19<br />

Group / Region / Department


s<br />

<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT Advanced<br />

Flow Statistics<br />

• Lowest and highest flow with date and time registration<br />

• Lowest and highest consumption per day with date registration<br />

• Consumption the latest 7 days, with consumption register<br />

for each day<br />

• Actual month consumption and last month<br />

page 20<br />

Group / Region / Department


<strong>SITRANS</strong> FM <strong>MAG</strong> <strong>8000</strong> GSM/GPRS<br />

Wireless Module<br />

s<br />

• The <strong>MAG</strong> <strong>8000</strong> WCM is a wireless<br />

communication module based on the<br />

GSM / GPRS technology.<br />

• The WCM is built in system to avoid<br />

compromise the IP 68 protection degree<br />

on the <strong>MAG</strong> <strong>8000</strong><br />

• Optional two analog inputs<br />

- One standard 4 – 20 mA (externally powered)<br />

- One ratiometric input 5 VDC powered by the<br />

<strong>MAG</strong> <strong>8000</strong><br />

• No proprietary SW require to get<br />

access to the data<br />

page 21<br />

Group / Region / Department


s<br />

<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />

Flow Tool Configuration Software<br />

Free download from Internet via standard<br />

IrDA connection to PC<br />

Flow Tool Purpose<br />

• Commissioning – equal setting of<br />

meters<br />

• Data print out for documentation<br />

• Data export as CSV file<br />

• Online with meter – Offline for<br />

preparing setting<br />

• Password – Hardware lock<br />

• Own parameter list<br />

• Service – transmitter replacement<br />

page 22<br />

Group / Region / Department


s<br />

<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />

<strong>Product</strong> Program<br />

• Compact – remote meter with 5 m, 10 m, 20 m and<br />

30 m sensor cable with plugs<br />

• Factory mounted I/O cable<br />

• Flanges EN1092-1, ANSI CL150, AS4087<br />

• Standard accuracy of 0.4% or 0.2%<br />

page 23<br />

Group / Region / Department


s<br />

<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />

Installed Base – More than 15,000 units installed globally<br />

• United Kingdom<br />

• Australia<br />

• US<br />

• France<br />

• Spain<br />

• Italy<br />

• Qatar<br />

• Denmark<br />

• Germany<br />

• Netherlands<br />

• Malaysia<br />

• Thailand<br />

• Poland<br />

• Canada<br />

• Portugal<br />

• Philippines<br />

• South Africa<br />

• Mexico<br />

• UAE<br />

• China<br />

• India<br />

Main reference installation of<br />

460 units for district monitoring<br />

page 24<br />

Group / Region / Department


s<br />

<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />

Typical Applications – Storm Water Metering - WWW<br />

Company: Himmark Purification Plant<br />

Location: Nordborg, Denmark<br />

Task: Storm water metering<br />

Why <strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong><br />

- The municipality already had 5 conventional<br />

<strong>MAG</strong> 5100 W meters installed in their plant and they<br />

were all 5 performing very well.<br />

- The <strong>MAG</strong> <strong>8000</strong> water meter is easy to integrate and<br />

as the meter is battery-driven, the installation costs<br />

are very low.<br />

- The built-in data logger means that all measurement<br />

data can be read on a computer screen – it<br />

considerably reduces the time it takes to inspect and<br />

read the meter.<br />

page 25<br />

Group / Region / Department


s<br />

<strong>SITRANS</strong> F M <strong>MAG</strong> <strong>8000</strong> / <strong>MAG</strong> <strong>8000</strong> CT<br />

Installed base<br />

1) Violia Water test<br />

laboratories<br />

2) Irrigation application<br />

3 + 4) District monitoring<br />

application in Denmark<br />

1 2<br />

3 4<br />

page 26<br />

Group / Region / Department


s<br />

Thank you<br />

very much<br />

Protection notice / Copyright notice