30-<br />

JULY 2006<br />

POWER SYSTEMS, INC.<br />

Introduction<br />

® ®<br />

With the introduction of the station class Type <strong>PVN</strong>,<br />

Ohio Brass has expanded its line of polymer-housed<br />

arresters for distribution, substation and transmission<br />

applications. <strong>PVN</strong> arresters are suitable for applications<br />

up through 230 kV. The <strong>PVI</strong> arresters are suitable for<br />

applications up through 138 kV.<br />

These designs combine the advantages of a polymer<br />

housing and metal-oxide varistor valve blocks, and offer<br />

the benefits of a one piece arrester construction for<br />

all voltage ratings. Stacking of individual arrester units<br />

is not required with polymer housings.<br />

Also available are porcelain and silicone station (Type<br />

VN, SVN and VL) arresters.<br />

All DynaVar Intermediate and Station Class Surge<br />

Arresters in this catalog comply with ANSI/IEEE<br />

Standard C62.11-1999. In addition, they are tested<br />

to IEC 99-4.<br />

The Type <strong>PVN</strong> Station Class Arresters described in this<br />

publication are protected by patent numbers 4,656,555;<br />

4,899,248; 4,905,118; 5,043,838; 5,138,517; 5,159,159<br />

and others pending.<br />

The Type <strong>PVI</strong> Intermediate Class Arresters described<br />

in this publication are protected by patent numbers<br />

4,656,555; 4,899,248; 4,905,118 and others pending.<br />

Warranty - Material<br />

Hubbell Power Systems, Inc. warrants all products sold by it to be merchantable (as such<br />

term is defined in the Uniform Commercial Code) and to be free from defects in material and<br />

workmanship. Buyer must notify the Company promptly of any claim under this warranty. The<br />

Buyer's exclusive remedy for breach of this warranty shall be the repair or replacement, F.O.B.<br />

factory, at the Company's option, of any product defective under the warranty which is returned<br />

to the Company within one year from the date of shipment. NO OTHER WARRANTY, WHETHER<br />

EXPRESS OR ARISING BY OPERATION OF LAW, COURSE OF DEALING, USAGE OF<br />

TRADE OR OTHERWISE IMPLIED, SHALL EXIST IN CONNECTION WITH THE COMPANY'S<br />

PRODUCTS OR ANY SALE OR USE THEREOF. The Company shall in no event be liable for<br />

any loss of profits or any consequential or special damages incurred by Buyer. The Company's<br />

warranty shall run only to the first Buyer of a product from the Company, from the Company's<br />

distributor, or from an original equipment manufacturer reselling the Company's product, and is<br />

non-assignable and non-transferable and shall be of no force and effect if asserted by any person<br />

other than such first Buyer. This warranty applies only to the use of the product as intended<br />

by Seller and does not cover any misapplication or misuse of said product.<br />

Warranty - Application<br />

Hubbell Power Systems, Inc. does not warrant the accuracy of and results from product or<br />

system performance recommendations resulting from any engineering analysis or study. This<br />

applies regardless of whether a charge is made for the recommendation, or if it is provided free<br />

of charge.<br />

Responsibility for selection of the proper product or application rests solely with the purchaser. In<br />

the event of errors or inaccuracies determined to be caused by Hubbell Power Systems, Inc., its<br />

liability will be limited to the re-performance of any such analysis or study.<br />

Table of Contents<br />

Page<br />

Introduction.................................................................2<br />

Warranty......................................................................2<br />

General Arrester Information.......................................3<br />

Arrester Application.................................................3<br />

Pressure Relief........................................................3<br />

Temporary Overvoltage Capability..........................3<br />

Polymer Housed Arresters..........................................4<br />

Description..............................................................4<br />

ESP Weathershed Material.....................................4<br />

Construction............................................................4<br />

Benefits...................................................................4<br />

Seismic Performance..............................................4<br />

Key to the Catalog Numbers.......................................5<br />

<strong>PVI</strong> Polymer Housed Intermediate Arrester................6<br />

Protective Characteristics........................................6<br />

Dimensions and Mounting.......................................7<br />

<strong>PVI</strong> Nameplates......................................................7<br />

<strong>PVI</strong> Terminals..........................................................8<br />

Mounting Information...............................................8<br />

<strong>PVI</strong>-LP Polymer Housed Intermediate Class<br />

Arresters.....................................................................9<br />

Dimensions and Mounting.......................................9<br />

Protective Characteristics......................................10<br />

<strong>PVI</strong>A Intermediate Class Surge Arresters.................11<br />

Dimensions and Mounting.....................................11<br />

Protective Characteristics......................................12<br />

<strong>PVN</strong> Polymer Housed Station Arresters...................13<br />

Protective Characteristics......................................13<br />

Mounting Positions................................................13<br />

Dimensions and Mounting.....................................14<br />

Grading Rings.......................................................14<br />

<strong>PVN</strong> Terminals.......................................................14<br />

Packaging (<strong>PVI</strong>/<strong>PVN</strong>)............................................15<br />

<strong>PVN</strong> Nameplates...................................................15<br />

Base Mounting Information...................................15<br />

Crossarm Mounting...............................................15<br />

Discharge Counters (<strong>PVI</strong>/<strong>PVN</strong>).............................15<br />

Insulating Subbases (<strong>PVI</strong>/<strong>PVN</strong>)............................15<br />

Brackets................................................................16<br />

<strong>PVN</strong>A Polymer Housed Station Class<br />

Surge Arresters.........................................................17<br />

Dimensions and Mounting.....................................17<br />

Protective Characteristics......................................18<br />

VL and VN Porcelain Housed Station Class<br />

Arresters...................................................................19<br />

Introduction............................................................19<br />

Application Guide..................................................19<br />

Description and Operation.....................................19<br />

Protective Characteristics......................................20<br />

Nameplates...........................................................20<br />

Dimensions and Mounting.....................................21<br />

SVN Polymer Housed Arresters................................22<br />

Construction..........................................................22<br />

Catalog Ordering System......................................23<br />

Protective Characteristics......................................25<br />

Nameplates...........................................................25<br />

Dimensions and Mounting.....................................26<br />

Discharge Counters..................................................27<br />

Insulating Subbases..............................................27<br />

Arrester Routine & Design Testing.........................28<br />

OHIO BRASS – AIKEN, SC