PREP<br />

<strong>ACE</strong> Preparative HPLC Columns<br />

<strong>ACE</strong> Preparative HPLC Columns<br />

■ Ultra high purity base deactivated silica<br />

■ 5, 10 and 15µm particle sizes available<br />

■ Fully validated columns<br />

■ Exceptional reproducibility<br />

■ Excellent efficiencies<br />

■ High sample recovery<br />

■ Excellent column lifetime<br />

■ 100Å and 300Å pore sizes<br />

Achieve Reproducible High Performance Preparative Separations<br />

Chromatographers with experience in preparative HPLC<br />

know that resolution and loadability are of the utmost<br />

importance. The greater the resolution, the higher the<br />

sample load and the faster pure compound is obtained.<br />

The ability to optimize resolution at the preparative scale<br />

means starting with high performance separations at the<br />

analytical scale. The same features that make <strong>ACE</strong> ultrainert<br />

base deactivated analytical columns the choice of<br />

method development chemists also make them the ideal<br />

choice for scale-up and process methods.<br />

Figure 32. Reproducible Scale-Up with <strong>ACE</strong> C18 Columns<br />

<strong>ACE</strong> 3 C18<br />

<strong>ACE</strong> 5 C18<br />

<strong>ACE</strong> 10 C18<br />

1<br />

1<br />

1<br />

2<br />

3<br />

2 4<br />

3<br />

2 4<br />

3<br />

4<br />

5<br />

5<br />

5<br />

Sample: 1) Uracil 2) 4-Hydroxybenzoic acid 3) Acetylsalicylic acid 4) Benzoic acid 5) 2-Hydroxybenzoic acid 6) Ethyl paraben<br />

Mobile Phase: 35:65 MeCN/0.1% TFA in H2O, Temperature: 22°C, Wavelength: 254nm<br />

32<br />

<strong>ACE</strong> preparative HPLC columns offer the following<br />

benefits:<br />

■ Loadability – high surface area and carbon load for<br />

maximum sample capacity<br />

■ Selectivity – available in 7 bonded phases to optimize<br />

sample capacity<br />

■ Rugged – reliable, long-term performance<br />

■ Guaranteed reproducibility – complete column/batch<br />

validation as for <strong>ACE</strong> analytical columns<br />

■ Guard cartridges – available for maximum column<br />

protection<br />

6<br />

6<br />

6<br />

LC/MS<br />

150 x 1.0mm i.d.<br />

0.05 ml/min<br />

capacity 10µg<br />

Analytical<br />

150 x 4.6mm i.d.<br />

1.00 ml/min<br />

capacity 200µg<br />

Preparative<br />

150 x 21.2mm i.d.<br />

21.2 ml/min<br />

capacity 4-50mg